• Title/Summary/Keyword: Fire management

Search Result 1,696, Processing Time 0.034 seconds

Control Frame Design for Improvement Transmit Efficiency in the Wireless Networks (무선 네트워크에서 전송효율증대를 위한 제어프레임 설계)

  • Han, Jae-Kyun;Pyeon, Seok-Beom
    • 전자공학회논문지 IE
    • /
    • v.48 no.2
    • /
    • pp.61-70
    • /
    • 2011
  • IEEE 802.11 wireless network supports control frames like RTS/CTS(Request To Send / Clear To Send). Because they is defend to frame collection problems. It helps to solve the frame collection problem but decreases the throughput rate. Also, control frame makes False Node Problem. This problem is makes to other wireless nodes don't work and don't find channels in the same cell and near cells. We proposed a reformed new control frame for efficiency throughput rate and solution of False Node Problem. New control frame is to have added to 4 bytes of channel detection ability at the RTS frames. Channel detection ability supported to check channel at the wireless node start to transmit data frame, We expect that channel detection ability make prevent False Node Problem for increase to access number to channel. We perform comparative analysis in terms of delay(sec) and load(bits/sec) with reform RTS/CTS method which proves the efficiency of the proposed method.

Design and Implementation of a Small Server Room Environment Monitoring System by Using the Arduino (아두이노를 이용한 소규모 서버 룸 환경 모니터링 시스템의 설계 및 구현)

  • Lee, Hyo-Seung;Oh, Jae-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.2
    • /
    • pp.385-390
    • /
    • 2017
  • Owing to the development of IT technology, a computerized system in various ways such as a variety of company's businesses, factory automation system and hospital healthcare system is introduced and operated. And it is possible to say that a computer system is more important than anything else to the extent that all businesses are suspended in case the system is down. Attention should be always paid to environmental management such as temperature, humidity and fire in server room for the normal operation of system in this situation. It is thought that there is necessity for a low-cost system which independently monitors environment round the clock in the situation where the person in charge doesn't pay attention and which informs a person in charge in real time when an event occurs for the operation of this small server room. Consequently, it is to be hoped that the suspension of service provided by computer system, which may occur due to a specific event, can be prevented.

A Study on the Integrated Monitoring of a Leakage Current of the Grounding Wire of Neutral Point of the Low Voltage Side of Transformer (변압기 저압측 중성점 접지선의 누설전류 통합 감시에 관한 연구)

  • Hong, Soon-Seuk;Park, Joon-Yeol;Lee, Jung-Eun;Choi, Kyung-Han
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.5
    • /
    • pp.106-113
    • /
    • 2010
  • If leakage current is neglected, it can become a cause for disasters such as electric shock and fire, therefore a continuous monitoring is necessary. However in most cases, because management of substations is performed by unmanned systems, or walk-around inspections, continuous monitor is difficult. So when an accident occurs and the cause is not immediately resolved causing the emergency generator's OCGR getting activated by the leakage current that in turn cut off the ACB, the emergency generator may stop working. To prevent such a problem, a real-time integrated monitoring system for monitoring the leakage current returning to the grounding wire of neutral point of the low voltage side of transformer is proposed. Therefore in this paper, the effects of flow of leakage current, which is caused by insulation degradation phenomena or insulation destroy phenomena, were identified by simulation. And through cases studies; the excellence of integrated monitoring system was verified.

A Study on Characteristic Analysis for Indoor Ventilation Performance of Mechanical Ventilation System (기계 환기시스템의 실내 환기성능 특성 해석에 관한 연구)

  • Ku, Jae-Hyun
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.2
    • /
    • pp.31-37
    • /
    • 2012
  • This paper describes to analyze the ventilation performance of a room air conditioner for indoor comfort control. An experimental apparatus consists of a test room, the room air conditioner, a tracer gas measurement system, a supply fan and a controller. Ventilation performance as a function of human occupancy is evaluated with supply ventilation air using a tracer gas technique of CO2 gas in the test room. The ventilation performance is evaluated in a step-down method based on ASTM Standard E741-83 and is found to increase with increasing supply ventilation rate. The CO2 gas concentration is decayed rapidly without human occupancy. The ventilation performance without human occupancy increases up to 55% and the ventilation performance with one person increases up to 25% at the supply air of 570 lpm comparing with a natural reduction after one hour. A modeling for ventilation performance of a room air conditioner in a test room is presented using experimental datum.

A Study on Development and Construction Methods of the Inorganic Floor Finishing Material of Hazardous Material Storage Facilities (위험물 저장시설의 무기질 바닥마감재와 이를 이용한 시공방법에 관한 연구)

  • Oh, Dong-Seok;Yu, Chul-Hee;Kim, Byung-Duk;Kim, Heum;Park, Sang-Min
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.4
    • /
    • pp.35-43
    • /
    • 2014
  • Usage of the inorganic floor finishing material can be advantageous to overcome some problems of traditional organic-based floor finishing material used for hazardous material storage facilities. A spark can be produced by physical impact between the flooring and the flooring disposal equipment while removing the existing flooring. In order to prevent a fire hazard, which may be caused the spark, it is feasible that a construction can be implemented without removing the existing flooring. Moreover, the top coating material containing an antistatic agent is effective to prevent secondary damage caused by static electricity after finishing the construction of the flooring. Therefore, the inorganic floor finishing material of the this study is expected to be beneficial for safety management and economical aspect for inspectors.

Antidepressant-related Fatalities in the Capital Region of Korea in 2010 (항우울제와 관련된 사망사례분석 - 2010년 수도권을 중심으로 -)

  • Chung, Heesun;Lee, Sangki
    • YAKHAK HOEJI
    • /
    • v.57 no.4
    • /
    • pp.289-292
    • /
    • 2013
  • A total of 2,080 forensic autopsies in Seoul, Incheon and Gyeonggi province were performed by the National Forensic Service (NFS) in 2010. After analysing blood samples collected at autopsies by GC-MS and LC-MS/MS, the types and prevalence of drugs and poisons in blood were investigated using our laboratory information management system. Among 2,080 cases, 1,061 cases (51%) were positive for drugs and poisons. Surprisingly, antidepressants were identified in 137 cases which comprised 13% of the positive cases. Twelve different kinds of antidepressants were determined: Amitriptyline, fluoxetine, nortriptyline, trazodone, imipramine, mirtazapine, citalopram, venlafaxin, clomipramine, paroxetine, sertraline and bupropion. Amitriptyline was the most frequently detected antidepressant and was identified in 39 cases. Moreover, amitriptyline, fluoxetine, and nortriptyline were included in the list of the 20 most commonly encountered drugs or poisons in the analysis of blood collected at autopsies from 2007 to 2009, indicating the prevalence of their use. In this study, the 137 antidepressant-related deaths were classified by the mode of death to predict the prevalence of these drugs. As a result, those deaths were divided into four groups based on the cause and mode of death: 56 cases of suicide with fatal concentrations of antidepressant drugs in blood, 6 homicidal cases directly or indirectly related to antidepressants, 59 natural deaths with antidepressants detected in blood and 16 deaths caused by fire or other accidents with antidepressants detected in blood. Because incidents involving antidepressants have been increasing, especially in suicides or homicides, it is necessary for the health authorities and law enforcement administrations to cooperate and share the statistical data for curbing the abuse of antidepressants. This report is expected to provide the reference data related with antidepressants for the investigation of the deaths.

A study on the Effects and Improvements of a Train Drivers' Licensing System (철도기관사 면허제 시행효과 및 개선방안에 관한 연구)

  • Lee, Chan-Bong;Park, Jin-Pyo
    • Journal of the Korean Society for Railway
    • /
    • v.18 no.1
    • /
    • pp.71-80
    • /
    • 2015
  • During normal subway rush hours, a train-driver is in charge of more than 3,000 people on a daily basis. When an emergency event occurs, millions of people and their property come to depend only on the train-driver's ability. After the Daegu subway fire disaster in February 2003, the Railway Safety Act was enacted in October 2004 and the 'Train Drivers' Licensing System' was introduced by the National Railroad Administration in July 2006 to secure and improve protection. This study was conducted to investigate and evaluate the effects of the Train Drivers' Licensing System since the Licensing System was first introduced eight years ago. In addition, the analysis will suggest better policies for the effectiveness of the 'Train Drivers' Licensing System'.

A Study on the Necessary Spaces and Area Standards of Integration Facility for Early Childhood Education and Care (영유아 교육·보육 통합시설의 필요 공간과 면적기준에 관한 연구)

  • Cho, Jin Il;Choi, Hyeong Ju
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.17 no.2
    • /
    • pp.22-37
    • /
    • 2018
  • This study suggests desirable disaster safety education curriculum through analyzing the operational status of the school disaster safety management training course and demand survey of school staff. First, the problem of the disaster safety training course of the school is not connected with the lack of law and system and the school disaster safety job. Second, improvement of law and system and variety of training should be made to acquire professional knowledge. Third, it is necessary to divide curriculum into the following four categories, according to educational needs of public officials ; Educational administration officers course focused on facility safety, maintenance and disaster countermeasure. Educational officials in technical post course addressing approval and permission of school facility projects, seismic reinforcement of school building, etc. Educational supervisors course covering roles and responsibilities of the school safety supervisors in the event of disaster. Teaching staffs course focused on safety instructions for students. Fourth, it is found that lectures and experiential learning methods are the most desirable methods of teaching and learning, and the major ranks are earthquake disaster, fire, gas, typhoon, school road, and electrical safety.

Influence of Coping, Self-Disclosure, Ruminant, and Organizational Culture on Traumatic Growth of Firefighters (소방공무원의 대처, 자기노출, 반추, 조직문화가 외상 후 성장에 미치는 영향)

  • Ko, Young-Shim;Ha, Yeong-Mi;Kim, Ji-Ah;Cho, Han-A
    • Journal of Digital Convergence
    • /
    • v.18 no.4
    • /
    • pp.357-369
    • /
    • 2020
  • This study aimed to examine the coping, self-disclosure, rumination, organizational culture and degree of Posttraumatic Growth(PTG) of firefighters who experienced trauma, and to identify the factors that influence PTG. Data collection was conducted for 103 firefighters working at three fire departments located in Gyeongsang-do. As a result of the study, 46(44.7%) PTGs of medium to high level averaged 58.07 points, and the total PTG average was 44.56 points. The influenced factors affecting PTG in firefighters were emotional-focused coping(EFC), self-disclosure(SD), deliberate rumination(DR) and innovative-oriented culture(IOC).The explanatory power of these factors PTG was 45.9%. In order to promote the firefighters 'PTG, it is necessary to approach of EFC, SE, and DR but also an organizational aspect as well as IOC construction, and these results can be used as an arbitration plan to improve the firefighters' PTG.

A Study on Methodology for Standardized Platform Design to Build Network Security Infrastructure (네트워크 보안 인프라 구성을 위한 표준화된 플랫폼 디자인 방법론에 관한 연구)

  • Seo, Woo-Seok;Park, Jae-Pyo;Jun, Moon-Seog
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.1
    • /
    • pp.203-211
    • /
    • 2012
  • Network security infrastructure is constantly developing based on the combination and blending of various types of devices. From the form of distributed control, the phased defense policy such as fire walls, virtual private communication network, invasion prevention system, invasion detection system, corporate security management, and TSM (Telebiometrics System Mechanism), now it consolidates security devices and solutions to be developed to the step of concentration and artificial intelligence. Therefore, this article suggests network security infrastructure design types concentrating security devices and solutions as platform types and provides network security infrastructure design selecting methodology, the foundational data to standardize platform design according to each situation so as to propose methodology that can realize and build the design which is readily applied and realized in the field and also can minimize the problems by controlling the interferences from invasion.