• Title/Summary/Keyword: Fire ignition

Search Result 518, Processing Time 0.022 seconds

Reaction of an Insensitive Munitions(IM) Igniter for Solid Propulsion System (고체 추진기관 둔감화 점화 장치의 반응)

  • Ryu, Byungtae;Lee, Dohyung;Ryoo, Baekneung;Choi, Hongseok
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.16 no.6
    • /
    • pp.85-91
    • /
    • 2012
  • This paper describes the results of study on reaction of insensitive igniter in which a pyrosensor is automatically sensing the rate of risk of fire or explosion of solid rocket motor exposed to an unexpected fire and makes the rocket motor burn itself safely. The Slow Cook Off(SCO) test following the regulation of MIL-STD-2105D was carried out with a rocket motor loaded with HTPB propellant, in which a thermal pyrosensor igniter was installed. The auto-ignition temperature measured was approximately $140^{\circ}C$ and it corresponded to Type V(Burning) reaction in SCO test, while the temperature by Kissinger equation was calculated to be $165.5^{\circ}C$.

A Study on the Possibility of Ignition by Disposable Lighter (일회용 라이터 이용, 차량화재 착화.발화 가능여부에 대한 행태 연구 분석)

  • Kim, Seong-Hoan;Oh, Jae-Keun;Jo, Young-Jin
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.9 no.1
    • /
    • pp.27-34
    • /
    • 2006
  • 2004년 2월~5월까지 대구시 달서구 00동 소재에서 연쇄방화가 발생 되어 수사를 하여 오던 중 우리경찰서에서 다방면으로 수사하여 차량화재 방화범 000를 검거 후 기소한 상태에서 공판이 진행되던 과정에서 변호인 측에서 일회용 라이터로는 차량을 착화 또는 발화의 가능성이 현저히 어렵다는 이유로 피고인의 무혐의를 주장하는 변론이 제기되어 00지방검찰청 000 담당검사의 요청에 의하여 혐의를 입증하고 검증할 수 있는 자료를 제출하고 검증자료가 없으면 본 건의 조건에 따르는 실험을 실시하고 감정결과를 제출하라는 지휘에 의거 우리경찰서 과학수사팀에서는 차량(프라이드)을 1대 구입하여 지방경찰청 과학수사팀, 국립과학수사구소 남부분소 이공학실 화재 연구실과 연계하여 차량화재 실험을 실시하고 실험과정 및 발화 행태와 양상을 구체적으로 증명할 수 있는 자료를 조사연구 분석하고 국립과학수사 연구소에서는 00지방검찰청에 촬영 데이터 원본영상과 촬영물, 그리고 감정서를 작성, 실험 결과를 문서화하여 제출하여 혐의를 입증한 사례 연구로 피의자에 대한 혐의 입증시 상황이나 정황 증거보다 실체적 진실증거의 중요성을 재인식 하고자 한다.

  • PDF

A Study on Combustion of Living Leaves for Various Coniferous Trees and Broadleaf Trees in Youngdong Areas (영동지역 주요 침엽수종 및 활엽수종 생엽의 연소특성에 관한 연구)

  • Lee, Hae-Pyeong;Lee, Si-Young;Park, Young-Ju
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.4
    • /
    • pp.96-103
    • /
    • 2009
  • This study was fulfilled to investigate the forest fire risk of forest fuels based on the combustion characteristics of living leaves of coniferous trees and broadleaf trees naturally growing in Youngdong areas of Gangwon Province by using cone calorimeter and smoke density chamber. According to the result, Pinus densiflora and Pinus rigida among coniferous trees released a greater amount of heat release than other kinds. The total smoke release varied depending on the species, whereas Pinus koraiensis showed the largest amount of smoke release. With regard to maximum smoke density, it was much higher in coniferous trees than in broadleaf trees. With regard to smoke temperature, Pinus densiflora showed the lowest compared to other kinds up until 200s from the ignition, but all most trees uniformly maintained constant temperature of about $70^{\circ}C$ after 200s. The concentrations of CO and $CO_2$ release were drastically increased at about 150s and then gradually decreased thereafter. Pinus densiflora showed a bit higher CO release than broadleaf trees, but there was no distinct difference in $CO_2$ release among tress.

A Study on the Explosion Riskiness with Flying of Activated Carbon (활성탄의 부유중 폭발 위험성에 관한 연구)

  • 김정환;현성호;이창우;함영민
    • Fire Science and Engineering
    • /
    • v.12 no.3
    • /
    • pp.3-9
    • /
    • 1998
  • We investigated the weight loss according to temperature using TGA in order to find the thermal hazard of brand-new activated-carbon and disused activated-carbon dusts, and the properties of dust explosion in variation of the specific surface area of their dust with the same particle size. Using hartman's dust explosion apparatus which estimate dust explosion by electric ignition after making dust disperse by compressed air, dust explosion experiments have been conducted by varying concentration and size of activated carbon dust. The explosion pressure of both activated carbon increased as the specipic surface area increased. The results indicated that brand-new activated-carbon of which specific surface area was larger three to four times than that of disused activated-carbon was much easier of dust explosion.

  • PDF

Design and Reliability Analysis of the Through Bulkhead Initiation Module for Arm-Fire-Device(AFD) (점화안전장치용 격벽 착화모듈 설계 및 신뢰도 분석)

  • Jang, Seung-Gyo;Cha, Hong-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.273-276
    • /
    • 2008
  • A Through Bulkhead Initiation Module(TBIM) has been designed which guarantees the seal property without using O-ring. The TBIM works as the shock wave generated by a donor charge transmits to the acceptor charge. The structural safety of TBIM housing has been calculated via modeling analysis, and the ignition performance has been proved by 10 cc closed bomb test. The reliability analysis has been made using Probit method on the base of performance test results. According to the reliability analysis the bulkhead thickness of TBIM which is the most important design parameter has been determined.

  • PDF

Analysis of Fire Patterns of Flammable Liquids for Oil Flow Tests of Compartment Fires with Reduced Simulation (축소 모의된 구획 화재의 흘림 실험에 대한 인화성 액체의 화재 패턴 해석)

  • Joe, Hi-Su;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.28 no.3
    • /
    • pp.43-48
    • /
    • 2014
  • The purpose of this study is to analyze the flame propagation speed, radiation range, diffusion pattern and combustion completion time of a fire by filling a divided space with single combustible substance. It was found that the flame propagation speed was the fastest (0.2 s) for kerosene and the lowest (82.1 s) for alcohol. In the case of paint thinner, it took 19.0 s for the flame to reach its peak at the fastest speed after ignition while in the case of alcohol, it took 138.6 s for the flame to reach its peak at the lowest speed. In the case of the combustion of 200 ml of flammable liquids, the combustion completion time was 79.9 s for paint thinner, which is the shortest, 135 s for gasoline, 170 s for kerosene, 231.4 s for diesel and 337.0 s for alcohol. In addition, when flammable liquids are combusted, the lower part of the flame is governed by laminar flow pattern and the upper part of the flame showed turbulence pattern. In the case of a test performed for bean oil, it could be seen that if the fire source was removed, the flame was automatically extinguished without further combustion and that white smoke was generated due to incomplete combustion.

Regional Optimization of Forest Fire Danger Index (FFDI) and its Application to 2022 North Korea Wildfires (산불위험지수 지역최적화를 통한 2022년 북한산불 사례분석)

  • Youn, Youjeong;Kim, Seoyeon;Choi, Soyeon;Park, Ganghyun;Kang, Jonggu;Kim, Geunah;Kwon, Chunguen;Seo, Kyungwon;Lee, Yangwon
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.6_3
    • /
    • pp.1847-1859
    • /
    • 2022
  • Wildfires in North Korea can have a directly or indirectly affect South Korea if they go south to the Demilitarized Zone. Therefore, this study calculates the regional optimized Forest Fire Danger Index (FFDI) based on Local Data Assessment and Prediction System (LDAPS) weather data to obtain forest fire risk in North Korea, and applied it to the cases in Goseong-gun and Cheorwon-gun, North Korea in April 2022. As a result, the suitability was confirmed as the FFDI at the time of ignition corresponded to the risk class Extreme and Severe sections, respectively. In addition, a qualitative comparison of the risk map and the soil moisture map before and after the wildfire, the correlation was grasped. A new forest fire risk index that combines drought factors such as soil moisture, Standardized Precipitation Index (SPI), and Normalized Difference Water Index (NDWI) will be needed in the future.

Fire Hazard of PP and LLDPE dust in Chemical Plant Process (석유화학플랜트에서 발생하는 PP(Poly Propylene) 및 LLDPE(Linear Low Density Poly Ethylene) 분진의 연소 위험성에 관한 연구)

  • 김정환;이창우;현성호;권경옥
    • Fire Science and Engineering
    • /
    • v.15 no.1
    • /
    • pp.16-22
    • /
    • 2001
  • Thermal properties of PP and LLDPE dusts from chemical plant and their risks of coexisting with oxidizer were investigated by a pressure vessel. The thermal decomposition of PP and LLDPE dusts with temperature using DSC and the weight loss with temperature using TGA were also investigated to find the thermal hazard of PP and LLDPE dusts. Using the pressure vessel which can estimate ignition and explosion of PP and LLDPE dusts coexisting with oxidizer, a series of bursting of a rupture disc, experiments has been conducted by varying the orifice diameters the weight ratio of the sample coexisting with oxidizers and the species of oxidizer. And fire gases was measured by gas analyser ($ECOM-A^+$). According to the results of the thermal analysis of PP and LLDPE dusts, the decomposition temperature range of PP and LLDPE dusts was 200 to 350 and 300 to $500^{\circ}c$, respectively. The risk of PP and LLDPE dusts coexisting with oxidizer was increased as the orifice diameter was decreased. On the other hand, it was increased as the weight ratio of the sample to the oxidizer were increased. In addition, the risk of PP and LLDPE dusts coexisting with oxidizer was affected by the decomposition temperature of the sample and oxidizer. It is found that the risk of fire becomes high when the decomposition temperature of the sample is about same as that of oxidizer. Also, the fire gases was occurred carbon monoxide and carbon dioxide. The amount of carbon monoxide generated was found to be much higher in PP decomposition than in LLDPE due to incomplete combustion of PP which has high content of carbon in chemical compound.

  • PDF

Effect of the HVAC Conditions on the Smoke Ventilation Performance and Habitability for a Main Control Room Fire in Nuclear Power Plant (원자력발전소 주제어실 화재 시 공조모드가 배연성능 및 거주성에 미치는 영향 분석)

  • Kim, Beom-Gyu;Lim, Heok-Soon;Lee, Young-Seung;Kim, Myung-Su
    • Fire Science and Engineering
    • /
    • v.30 no.5
    • /
    • pp.74-81
    • /
    • 2016
  • This study evaluated the habitability of operators for main control room fires in nuclear power plants. Fire modeling (FDS v.6.0) was utilized for a fire safety assessment so that it could determine the performance of the smoke ventilation and operator habitability with the main control room. For this study, it categorized fire scenarios into three cases depending on the conditions in the HVAC system. As a result of fire modelling, it showed that Case 1 (with HVAC) would give rise to the worst situation associated with the absolute temperature, radiative heat flux, optical density, and smoke layer height as deliberating the habitability and smoke ventilation. On the other hand, it showed that Cases 2 (w/o HVAC) and 3 can maintain much safer situations than Case 1. In the case of temperature at 820 s, Cases 2 and 3 were up to approximately 63% greater than Case 1 in the wake of ignition. In addition, the influence of radiative heat flux of Case 1 was even larger than Cases 2 and 3. That is, the radiative heat fluxes of Cases 2 and 3 were approximately 68% higher than Case 1. Furthermore, when it comes to considering the optical density, Case 1 was approximately 93% greater than Cases 2 and 3. Accordingly, it expected that the HVAC system can influence a the performance on the smoke ventilation that can be sustainable for operator habitability. On the other hand, it revealed an inconsecutive pattern for the smoke layer height of Cases 2 and 3 because supply vents and exhaust vents were installed within the same surface.

The Measurement of Autoignition Temperature for n-Propanol and Formic acid System (n-Propanol과 Formic acid계의 자연발화온도 측정)

  • Park, Sang-Hun;An, Jong-Il;Kim, Se-Ho;Park, Yoon-A;Choi, Jin-Young;Han, Jin-Seok;Oh, Su-Yong;Jang, Seon-Yeon;Ha, Dong-Myeong
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.164-164
    • /
    • 2013
  • 화학 관련 산업은 고온, 고압뿐만 아니라 반응성이 큰 물질들을 사용하는 복잡한 공정으로 이에 맞는 안전기술이 요구된다. 산업 현장에서 취급하고 있는 각종 화학물질의 안전관리를 어렵게 하는 이유는 취급하는 물질의 화재 및 폭발 특성치에 관한 자료가 부족하거나 정확하지 않은 연소 특성치를 사용하기 때문이다. 가연성물질의 연소현상 가운데 하나인 자연발화는 가연성 혼합기체에 열 등의 형태로 에너지가 주어졌을 때 스스로 타기 시작하는 산화현상으로, 주위로부터 충분한 에너지를 받아서 스스로 점화할 수 있는 최저온도를 최소자연발화온도(AIT : Auto ignition Temperature)라고 한다. 최소자연발화온도는 가연성 액체의 안전한 취급을 위해 중요한 지표가 된다. 순수물질의 최소자연발화온도를 문헌들에서 비교하면, 동일 물질인데도 불구하고 문헌에 따라 다른 최소자연발화온도가 제시되고 있다. 따라서 사업장에서 사고를 예방하기 위해서는 정확한 연소 특성 자료를 이용해야 해야 한다. 그러나 문헌에 제시된 대부분의 자료들은 과거 표준장치 및 자체 제작된 장치 등을 사용해서 얻은 결과이므로, 최근에 고안된 표준 장치를 이용한 결과가 매우 유용한 자료가 될 것으로 본다. 본 연구에서는 자연발화온도를 측정하는데 있어서 최근에 고안된 표준장치인 ASTM E659장치를 이용하여 n-Propanol과 Formic acid 혼합물의 최소자연발화 온도를 측정하였다. n-Propanol과 Formic acid 혼합물의 최소자연발화 온도는 화학 관련 산업 공정에서 매우 중요한 자료가 될 것이다.

  • PDF