Comparative Analysis of Preparation Time between Rack-type and Reel-type Fire Hoses (호스걸이형 소방호스와 호스릴 소방호스의 전개시간 비교 분석)

  • Hong, Suk-Hwan;Kim, Seo-Young;Kong, Ha-Sung
    • Journal of the Korea Safety Management & Science
    • /
    • v.23 no.4
    • /
    • pp.49-53
    • /
    • 2021
  • The objective of this study was to understand which type of fire hose should be placed in indoor fireplug box upon analyzing the preparation time between rack-type fire hose and reel-type one. With respect to the type of hose, rack-type stacking method was used and hose preparation time was measured with 5 times of repeat test, separating men and women. Study results reveal that preparation time of reel-type fire hose took longer than that of rack-type one in both men and women. For both rack-type hose and reel-type hose, preparation time by two persons took shorter than that by one man. Also, preparation time by three persons took shorted than that by two women. Preparation time for both rack-type hose and reel-type one by men took shorter than that by women. In summary, it was confirmed that rack-type hose could be prepared within shorter time than reel-type one. Since the size of drum set in the reel-type fire hose is relatively small, it had some difficulty in preparation of fire hose timely.

Study on the Pressure Loss of Hoses in a Fire Hose Reel Hydrant (호스릴옥내소화전 호스에 대한 압력손실에 관한 연구)

  • Whang, Young-Kwon;Lee, Seung-Chul
    • Fire Science and Engineering
    • /
    • v.33 no.2
    • /
    • pp.63-67
    • /
    • 2019
  • In this study, the pressure loss of a fire hose reel hydrant was examined and the effects of each factor on the pressure loss were analyzed. First, in the pressure loss experiment according to the length of the reel hose, the pressure loss increased with increasing length of the reel hose; it was approximately 38.86% based on a 25 m hose. Second, the pressure loss of the reel hose per unit length was estimated to be $.13{\sim}.15kgf/cm^2$. Third, in the pressure loss experiment according to the change in the flow rate, the result was similar to the relation, flow rate - pressure loss (${\Delta}P{\sim}Q^2$), in the piping flow. These results provide basic data on the evaluation of fire pump pressure and the performance-based fire-protecting design of fire hose reel hydrants used in buildings.

A Comparative study of the performance for hose reel hydrant system and indoor hydrant system (호스릴옥내소화전설비와 옥내소화전설비의 성능 비교 연구)

  • Nam, Jun-Seok;Baek, Chang-Sun;Kim, Joon-Bae;Kang, Tae-Young;Park, Sung-Ock;Han, Jae-Ho
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.104-107
    • /
    • 2008
  • The performance of hose reel hydrant system and indoor hydrant system was tested comparatively. At that result, a hose reel hydrant system are excellent and have the same performance as indoor hydrant system. If hose reel hydrant system has the performance that pressure is more than 0.17 MPa and flow-rate is over 130 LPM at the nozzle, it can be substituted for indoor hydrant system.

  • PDF

Improvement Proposal for the Fire Suppression Systems of Open Parking Lots (개방형주차장의 소방설비 개선 제안)

  • Jeong, Keesin
    • Fire Science and Engineering
    • /
    • v.30 no.6
    • /
    • pp.1-8
    • /
    • 2016
  • In cars, the amount of combustibles, such as plastics, textiles, etc., have increased dramatically to improve the fuel efficiency of cars by reducing the gross vehicle weight according to the increases in an oil price and to reduce environmental problems. One or two cars were involved in a parking lot fire prior to the mid-2000 s. On the other hand, there were many parking lot fires where the entire car was destroyed due to increasing the use of plastics. In this study, the quantity of combustibles in a car was 316.2 kg over a total weight 1935 kg. This is 16.34% of total weight and 10 times greater than that three decades earlier. When a sprinkler is installed as a parking lot fire protection system as a substitute for water spray, the water discharge of the sprinkler must maintain the original density of water spray, $20lpm/m^2$. In addition, the use of a hose reel $CO_2$ system at pilotis parking lots must be prohibited because the hose reel $CO_2$ system has no adaptability for a car fire. Instead, this study proposes foam, dry powder, loaded stream systems be used in parking lot fire suppression systems.

A Study on the Application Medium Expansion Foam Extinguisher by a Fire Performance Analysis used Medium Expention Foam Agent (중발포 소화약제 소화성능 분석을 통한 중발포기 적용에 관한 연구)

  • Lee, Jang Won
    • Journal of the Society of Disaster Information
    • /
    • v.15 no.3
    • /
    • pp.402-408
    • /
    • 2019
  • Purpose: The study want to verify application the medium expantion foam extinguisher of expantion foam rate and fire extinguishing Performance test because the medium expansion system can maintain the discharge distance less affected by air currents, and the foam agent can be used efficiently. Method: For the study, the medium-expansion testing apparatus was manufactured and with synthetic surfactant foam agent of (class B) fire extinguishing model, and Fire Performance was analyzed for foam expansion rate and the fire agent consumption was measured and analyzed. Results: We measured the medium-spray testing apparatus and found that the expansion rate was 26.1 times. The test results of a 20-unit fire extinguishing model show that the extinguishing time is faster than the high and low foam expansion. It has been analyzed that it is possible to apply a hand-operated with a hose reel or medium expansion apparatus. Conclusion: Considering that the foaming agent and the extinguishing performance of the medium foam ratio are excellent, It is necessary to introduce the technical standards of medium foam agent for the introduction of hand-operated equipment, such as hose reel or portable medium foam apparatus.

A Study on the Methods of Fire-Safety in Cultural Property Wooden Buildings (목조 문화재 건축물의 화재 방재를 위한 조사 연구)

  • Chang, Hyung-Soon;Cho, Won-Seok;Kim, Heung-Gee
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.10 no.4
    • /
    • pp.25-32
    • /
    • 2008
  • The prevention of disasters in cultural property is very important management and historical duties. The reason can't be measured values with monetary scale of our contemporary. Therefore, this paper was considered fire-safety as one of terrible threat-disasters about the wooden buildings. This research deal with 47 cases cultural property wooden building by whole investigation(field survey and interview) in Gangnung province. The most buildings have basic fire extinguisher; ABC powder. A few buildings are rarely installed fire extinguishing equipments; outdoor fire hydrant, heat sensor, ground sprinkler, CO2-hose-reel. But these state is very insufficient for the fire-safety in cultural property wooden buildings. Specially as particular attention in province, forest fire of regional characteristic have close relation with cultural property fire. The majority of factor against forest and building fire is to provide monitoring and security system; CCTV, Fence, Sensor, Alarm and paid guard man against incendiary. Ultimately it is necessary to construct comprehensive disaster prevention system with the organic cooperation such as National Emergency Management Agency, Cultural Heritage Administration, Forest Service, local government officials and regional citizen.