• Title/Summary/Keyword: Fire flow velocity

Search Result 137, Processing Time 0.026 seconds

Numerical Study of the Factors Affecting Fire Flow Velocity in the Case of Interior Fire in an Apartment Building (공동주택 화재 시 화재풍속에 영향을 미치는 인자들에 관한 수치해석적 연구)

  • Kim, Byeongjun;Seo, Chanwon;Shin, Weon Gyu
    • Fire Science and Engineering
    • /
    • v.30 no.4
    • /
    • pp.14-19
    • /
    • 2016
  • When an interior fire occurs in an apartment building, pollution of the entrance area by fire smoke before an air fan operates makes the evacuation of people very difficult aswhen the fire doors are opened. Numerical simulations using Fire Dynamics Simulator were conducted to determine the impact of a sprinkler on the fire flow velocity. The fire flow velocity was compared depending on the presence of sprinklers and the sprayed droplet size. The configuration and actual dimensions of an apartment building were used in the numerical simulations. The simulation results showed that fire flow velocity becomes smaller when a sprinkler is installed. In addition, the smaller droplet size results in a smaller fire flow velocity because smaller droplets can be evaporated more easily.

Experimental Study on Heat Flow According to the Wind Velocity in an Underground Life Space (지하생활공간 화재시 풍속에 따른 열유동 특성 연구)

  • Kim, Young-No;Suk, Chang-Mok;Kim, Wha-Jung
    • Fire Science and Engineering
    • /
    • v.21 no.3
    • /
    • pp.61-68
    • /
    • 2007
  • The purpose of this study analyzes heat flows and fire behavior through a reduced-scale model experiments about change of wind velocity in underground life space. When the wind velocity is increased the temperature rise time of the fire room was risen fast. And temperature of fire room was increased. And increase of wind velocity displayed maximum temperature at an opening of the fire room. Heat flows by fire spread increase size of smoke occurrence and flame, and displayed high temperature distribution in passageway than inside of neighborhood department promoting eddy flow spread as wind velocity increases. Finally, heat flows are decided by wind and wind velocity at fire of underground life space, and Wind velocity increases, temperature increase and decrease could confirm that is gone fast.

Numerical Study on the Effect of Heat Release Rate and Interior Opening on Fire Flow Velocity in the Case of Interior Fire in an Apartment Building (공동주택 화재 시 화재크기 및 실내 개구부 크기가 화재풍속에 미치는 영향에 관한 수치해석적 연구)

  • Seo, Chanwon;Shin, Weon Gyu
    • Fire Science and Engineering
    • /
    • v.28 no.5
    • /
    • pp.37-43
    • /
    • 2014
  • In the case of interior fire in an apartment building, contamination of vestibule area by fire smoke before air fan operating when fire doors are open makes the evacuation of people very difficult. In order to investigate the effect of heat release rate (HRR) and interior opening on fire flow velocity, numerical simulations using Fire Dynamics Simulator were carried out. In simulations, actual dimensions and configuration of an apartment building were considered and interior leakage and HRR were varied. From simulation results, it was found that fire flow velocity distribution is significantly influenced by HRR and interior opening resulting in the change of the location of a neutral plane. Also, it is shown that there is a larger difference of the fire flow velocity between upper and lower part of the fire door when the neutral plane becomes closer to the ceiling.

CROSS FLOW EFFECTS ON THE FLAME HEIGHT OF AN INTERMEDIATE SCALE DIFFUSION FLAME

  • Kolb, Gilles;Torero, Jose L.;Most, Jean-Michel;Joulain, Pierre
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.169-177
    • /
    • 1997
  • An experimental study has been conducted at an intermediate scale to study the effect of a cross flow on a purely buoyant fire. Video taping of the flame and post processing of the images by means of a novel technique provide a contour of a mean flame for all cases studied. This flame contour allows the determination of a mean flame length and a mean flame height. The mean flame length and height are recorded as functions of the forced flow velocity. Three dimensional flow patterns are formed in the flame trailing edge affecting both the mean flame length and height. The three dimensional patterns are studied systematically as functions of the cross flow velocity to quantify the effect of confinement on the flame geometry.

  • PDF

Numerical Investigation on Fire of Stage in Theater: Effects of Natural Smoke Vent Area and Fire Source Location (공연장 무대부 화재에 대한 전산해석 연구: 자연 배연구 면적과 화원 위치 영향)

  • Park, Min Yeong;Lee, Chi Young
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.1
    • /
    • pp.1-11
    • /
    • 2022
  • This numerical study investigates the effects of the size of the natural smoke vent area (10% and 1% of the floor area) and the location of the fire source (i.e., at the side and center of the stage) on the temperature distribution in the compartment and velocity distribution and mass flow rate of flow through a natural smoke vent for a reduced-scale model of a theater stage. Then, the mass flow rate of outflow through the natural smoke vent in the event of a fire for a real-scale theater stage was examined. The case with the larger natural smoke vent area and central fire source location showed lower temperature distributions and higher mass flow rates of outflow and inflow than the case with the smaller natural smoke vent area and side fire source location. The trends of the temperature distributions were closely related to those of the mass flow rates for the outflow and inflow. Additionally, the case with the larger natural smoke vent area and central fire source location exhibited the most non-uniform flow velocity distribution in all cases tested. A bidirectional flow, in which the outflow and inflow occur simultaneously, was observed through the natural smoke vent. In the event of a fire situation in a real-scale theater stage, it was predicted that the case with the larger natural smoke vent area and central fire source location would have a mass flow rate of outflow that is 43.53 times higher than that of the case with the smaller natural smoke vent area and side fire source location. The present results indicate that the natural smoke vent location should be determined by considering the location in a theater stage where a fire can occur.

Comparative Study on The Numerical Simulation for The Back-Layer of The Tunnel Fire-Driven Flow with LES and RANS (터널화재유동의 역기류 해석을 위한 LES 및 RANS 결과의 비교 고찰)

  • Jang, Yong-Jun;Kim, Hag-Beom;Kim, Jin-Ho;Han, Seok-Youn
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.3
    • /
    • pp.156-163
    • /
    • 2009
  • In this study, comparative analysis on the back-layer phenomena in the tunnel-fire driven flow is performed using numerical simulation with LES and RANS. FDS(Fire Dynamics Simulator) code is employed to calculate the fire-driven turbulent flow for LES and Smartfire code is used for RANS. Hwang and Wargo's data of scaling tunnel fire experiment are employed to compare with the present numerical simulation. The modeled tunnel is 5.4m(L) ${\times}$ 0.4m(W) ${\times}$ 0.3m(H). Heat Release Rate (HRR) of fire is 3.3kW and ventilation-velocity is 0.33m/s in the main stream. The various grid-distributions are systematically tested with FDS code to analyze the effects of grid size. The LES method with FDS provides an improved back-layer flow behavior in comparison with the RANS (${\kappa}-{\epsilon}$) method by Smartfire. The FDS solvers, however, overpredict the velocity in the center region of flow which is caused by the defects in the tunnel-entrance turbulence strength and in the near-wall turbulent flow in FDS code.

A Study on the Calculation of Critical Velocity by Fire Intensity (화재강도에 따른 임계풍속산정에 관한 연구)

  • Kim, Jong-Yoon;Lim, Kyung-Bum;Seo, Tae-Beom;Rie, Dong-Ho;Yoo, Ji-Oh
    • Fire Science and Engineering
    • /
    • v.20 no.4 s.64
    • /
    • pp.91-97
    • /
    • 2006
  • This study was executed to review feasibility on the calculation of critical velocity with a reduced model of an actual tunnel in order to establish the optimum fire protection system for a fire in road tunnels. In a scaled model about 1/29 of an actual tunnel based on the Froude scaling, critical velocity was calculated by visualizing smoke flow and analyzing correlation with temperature. In the experiment, critical velocities at which smoke backflow length became zero showed a small difference within about 5% compared to results calculated by the Kennedy formula, and the relation between smoke flow and temperature distribution appeared similarly without getting greatly influenced by changes in fire intensity.

Numerical Study on Air Egress Velocity of Ancillary Room Pressurization Systems in Apartment Fires (공동주택 화재 시 부속실 가압 시스템의 방연풍속에 관한 수치해석적 연구)

  • Kim, Byeongjun;Yang, Ying;Shin, Weon Gyu
    • Fire Science and Engineering
    • /
    • v.34 no.4
    • /
    • pp.78-86
    • /
    • 2020
  • In this study, numerical simulations were performed on the air egress velocity of pressurization systems in an ancillary room when a fire occurred in an apartment house. The relationship between the air supply flow rate of a damper and air egress velocity at a fire door is predicted to be linear. Additionally, a minimum flow rate of the damper, which meets national fire safety standards for air egress velocity, i.e., 0.7 m/s can be estimated. Air egress velocity at the fire door is analyzed according to the supply air direction and installation height of the damper. When the damper has an upward supply air direction and is installed at a high level, the egress velocity at the top section of the fire door is larger, whereas the soot concentration at the ancillary room is lower than when the supply direction of the damper is downward. Therefore, it is found that increasing the air egress velocity at the top section of the fire door helps to efficiently prevent the inflow of smoke.

Characteristics of Fire-induced Thermal-Flowfields in an Underground Utility Tunnel with Ventilation (화재 발생시 환기방식에 따른 지하공동구내 열유동 특성 연구)

  • Kim, Hong-Sik;Hwang, In-Ju;Kim, Yun-Je
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1845-1850
    • /
    • 2003
  • The underground utility tunnels are important facility as a mainstay of country because of communication developments. The communication and electrical duct banks as well as various utility lines for urban life are installed in the underground utility tunnel systems. If a fire breaks out in this life-line tunnel, the function of the city will be discontinued and the huge damages are occurred. In order to improve the safety of life-line tunnel systems and the fire detection, the behaviors of the fire-induced smoke flow and temperature distribution are investigated. In this study we assumed that the fire is occurred at the contact or connection points of cable. Numerical calculations are carried out using different velocity of ventilation in utility tunnel. The fire source is modeled as a volumetric heat source. Three-dimensional flow and thermal characteristics in the underground tunnel are solved by means of FVM (Finite Volume Method) using SIMPLE algorithm and standard ${\kappa}-{\varepsilon}$ model for Reynolds stress terms. The numerical results of the fire-induced flow characteristics in an underground utility tunnel with different velocity of ventilation are graphically prepared and discussed.

  • PDF

Characteristics of Air Egress Velocity in Vestibule Pressurization System Using the Fire Dynamics Simulator (FDS를 이용한 특별피난계단 부속실 제연설비의 방연풍속 기류특성)

  • Ryu, Sung-Ho;Lee, Su-Kyung;Hong, Dae-Hwa;Choi, Keum-Ran
    • Fire Science and Engineering
    • /
    • v.24 no.6
    • /
    • pp.153-159
    • /
    • 2010
  • In this study, we confirmed the fact that air egress velocity of pressure differential system installed at vestibule of smokeproof stairway in domestic high-rise building becomes back-flow to stair-lobby at upper vestibule. Rather it do not back-flow to the livingroom. when fire occur and the door opens to escape from fire zone. so we carry out actual and computational fluid dynamics measurement. In the case upward 45 gradient of supply damper's blade, The simulation results that air flow of upper vestible is steady but back-flow phenomenon occurred at the bottom. However, in the case of $4m^2$, direction of the flow was ideal to living room. If a vestibule’s area is smaller, it must be designed and built according to performance-based design.