• Title/Summary/Keyword: Fire fighter performance

Search Result 11, Processing Time 0.022 seconds

Effect of Fire Fighters' Turnout Gear Materials Air Gap on Thermal Protective Performance (소방보호복 소재의 공기간극이 열보호 성능에 미치는 영향)

  • Lee, Jun-Kyoung;Kwon, Jung-Suk
    • Fire Science and Engineering
    • /
    • v.28 no.4
    • /
    • pp.97-103
    • /
    • 2014
  • To ensure adequate protection from the risk of burns, fire fighter's turnout has a composite of more than three components and air gaps between layers of materials. During the flame exposure, radiation and convection heat transfer occurs in the air gap, thus the air gap acts as a thermal resistance with non-linear characteristics. Therefore, in this study, the experiments were performed to identify the effect of various air gap width (0~7 mm) on the thermal protective performance of fire fighter's clothing. The temperatures on each layer and RPP (Radiant Protective Performance, the most effective index representing the thermal protective performance) were measured with various incident radiant heat fluxes. The temperature at the rear surface of the garment decreased and RPP increased with increasing air gap width because the thermal resistance increased. Especially, it could be found that RPP value and air gap width has almost linear relation for the constant incident heat flux conditions. Thus relatively simple RPP predictive equation was suggested for various incident heat flux and air gap conditions.

Performance Evaluation of Search Robot Prototypes for Special Disaster Areas (특수재난지역 정찰로봇 시제품의 성능평가연구)

  • Kwark, Jihyun
    • Fire Science and Engineering
    • /
    • v.29 no.6
    • /
    • pp.109-118
    • /
    • 2015
  • Recently, three kinds of search robot prototypes were developed to assume the role of fire fighters for search and rescue missions in special disaster areas with high heat, smoke, toxic gases, or radioactivity. To accomplish search missions, these robots should be able to endure heat, overcome various obstacles, suppress fires, and see through dense smoke. This study investigated the heat resistance, practicality, and fire fighting capacity of these robots. The results show that the small and middle-sized robots were resistant to surrounding temperatures of $100{\sim}200^{\circ}C$, and the fire-fighter-riding robot could endure up to $500^{\circ}C$ for half an hour. The fire-fighter-riding robot showed excellent extinguishing performance on an A-10 class fire model, which was extinguished within 3 min. The robots also showed various capacities for overcoming obstacles and are expected to play an active role in various special disaster areas.

Inhibitory Effect of adding Phase Change Material (PCM) to Fire Fighter Protective Clothing on Burn Injuries (Phase Change Material (PCM) 소재 적용 소방보호복의 화상발생 억제효과에 관한 연구)

  • Lee, Jun Kyoung
    • Fire Science and Engineering
    • /
    • v.30 no.3
    • /
    • pp.16-22
    • /
    • 2016
  • Fire fighters rely on fire fighter protective clothing (FFPC) to provide adequate protection in the various hazardous environments. To enhance its protection performance, the FFPC material must be thick and thus it is difficult to achieve weight reduction. One of the methods of overcoming this problem, the addition of phase change material (PCM) to FFPC, is a new technology. In previous studies, the researches was mostly related to the temperature characteristics of the fibers incorporating PCM, but little information is available about its effect on burn injuries. Thus, in this study, the inhibitory effects of adding PCM to FFPC on second degree burns were investigated through numerical calculations. Thermal analyses of biological tissues and FFPC with embedded PCM exposed to several fire conditions causing severe tissue damage were studied by using a finite difference method based on the Pennes bio-heat equation. FFPC with embedded PCM was found to provide significantly greater protection than conventional fire fighting clothing, because the heat of absorption due to the phase change within the material is used to limit the heat conduction of the material.

Study on the Thermal Protective Performance Measurements of Fire Fighter's Protective Clothing for Low Level Radiant Heat Exposures (저열유속 조건의 복사열 노출에 따른 소방보호복의 열보호성능 측정에 관한 연구)

  • Lee, Jun-Kyoung;Bang, Young-Jun;Bang, Chang-Hoon;Kwon, Jung-Suk
    • Fire Science and Engineering
    • /
    • v.28 no.2
    • /
    • pp.1-8
    • /
    • 2014
  • Despite advancements in the development of synthetic fibers and materials that provide better insulation, fire burn injuries remain a significant issue. To ensure adequate protection, clothing and equipment must be selected on the basis of performance. There are different standards like ISO standards applicable to each of the various types of clothing used by fire fighters. But, in most cases, the tests are performed in the conditions of high heat flux exposure, the clothing material can be destroyed easily. Thus the effective way to investigate the protective performance for the low (radiant) heat flux conditions should be needed. Therefore improved RPP (Radiant Protective Performance) test method based on the onset of pain burn injury was suggested. Experiments were performed to verify the proposed method with current protective clothing for fire fighters and the transient heat transfer characteristics were identified, also. Moreover, several protective performance indices were acquired from experimental results to analyze their relations.

A Study on Beam Operation of an Airborne AESA Radar with Uniform Search Performance in Whole Scan Area (전 탐색 영역 균일 성능을 갖는 항공기 탑재 능동 위상 배열 레이더의 빔 운용 연구)

  • Ahn, Chang-Soo;Roh, Ji-Eun;Kim, Seon-Joo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.6
    • /
    • pp.740-747
    • /
    • 2012
  • An Active Electronically Scanned Array(AESA) radar required necessarily as the Fire Control Radar(FCR) of recent fighters has ununiform detection range with regard to scan angle due to scan loss. Although the compensation method of scan loss in an AESA radar with variable dwell time is investigated, the effectiveness of the method in a fighter FCR with multi-function such as search, track, and missile guidance within limited resources should be considered systematically. In this paper, uniform search performance of an AESA radar using variable dwell time with regard to scan angle is derived. We assumed the search load of 50 % for case without changing dwell time in fixed frame time and showed the fighter FCR requirement for multi-function is not satisfied because the search load for the uniform search performance should be increased by about 100 %. On the other hand, in case of increasing the frame time for the uniform search performance and search load of 50 %, degradation of the search performance is shown by 86.7 % compared with the former. Based on these analyses, the effective beam operation strategy on an airborne AESA radar with uniform search performance in whole scan area is described with consideration of frame time, search load and performance as a whole.

Effects of a High-Intensity Interval Training Program on the Fitness and Performance of Firefighters (고강도 인터벌 트레이닝(HIIT)이 소방공무원의 체력 및 업무능력에 미치는 영향)

  • Kim, Cherho;Ji, Changjin;Kim, Sangho
    • Fire Science and Engineering
    • /
    • v.34 no.2
    • /
    • pp.97-102
    • /
    • 2020
  • The purpose of this study was to investigate the effectiveness of a Tabata exercise program as an alternative for firefighters whose working environment makes it difficult to manage physical fitness. The Tabata exercise program, in which 16 people participated, led to increased muscle mass and reduced weight and body fat, which not only improved the health of the firefighters but also improved their cardiopulmonary endurance, muscle endurance, and muscle strength, which are essential elements during firefighting emergency relief activities. On the basis of these results, it is believed that developing and providing guidelines for scientific and systematic exercise programs to firefighters will lead to better work capability during fire and disaster situations.

A Study on ASET Elongation & Notification Time to Fire Stations for the Escape Safety of Aged Bedridden Patients in Elderly Long-term Medical Care (노인의료복지시설 화재 시 와상노인의 피난안전성 제고를 위한 피난허용시간 연장과 소방기관으로의 통보시간 연구)

  • Park, Hyung-Joo;Lee, Young-Jae
    • Fire Science and Engineering
    • /
    • v.32 no.4
    • /
    • pp.50-59
    • /
    • 2018
  • Recently, huge life losses occurred in the elderly long-term medical care fires due to lack of escape safety. As part of the measures to enhance the effectiveness of fire escape safety, while they prolong the available safe egress time (ASET) of non fire compartments, a measure to shorten fire-fighter's arrival time by fire alarm notifying device should be implemented in these facilities. The four categories from the aspects of fire prevention/protection engineering were provided with the necessary component technologies for carrying out these helper-guided evacuations. Fire prevention engineered technology was presented by two provisions; one for ensuring small compartment sections by installing the fire rated wall between bed rooms and another for ensuring the fire retardant or/and non-flammable performance of finishing materials. Also fire protection engineered technology was presented by two items; one for imposing cooling effects by sprinklers and another for providing automatic fire alarm notifying functions to fire stations. In order to improve the escape safety of these facilities in Korea, alternative revisions may presented by considering insufficient provisions in the architectural/fire law provisions by analyzing the provisions of Japanese and domestic laws in detail.

Discussion on Formulation Process and Configuration of Fire-Fighting Vulnerable Zone Model (소방취약지 모델의 구성과 정립프로세스 논의)

  • Kim, Seong Gon;Chang, Eun Mi;Choi, Gap Yong;Kim, Hi Tae
    • Spatial Information Research
    • /
    • v.22 no.3
    • /
    • pp.71-77
    • /
    • 2014
  • There are numbers of unpredictable risk factors in the disaster scenes such as fire, explosion and fail to early life-saving or holding the flames which can lead to massive damage. In particular, fire-fighters who arrive on the scene within 5 minutes after dispatching, have a limitation to get aware to the situation of scene fully, because of immediate deploy to disaster scene with limited information. This situation may lead to disturbance that fire-fighters perform effective fire-fighting activities, to put fire-fighter's life at risk by misjudge the situation. Previous domestic and International studies focused vulnerability for spatial area or features which can damage to life and property in the event of anticipated. In this study, we have been developed fire-fighting vulnerable zone model that can analyze comprehensively hindrance factors for fire-fighting activities targeting whole life cycle of fire-fighting activities from dispatch to fire suppression or life-saving. In addition, we have been given shape to finality and applicability for our model by defining the new concept of fire-fighting vulnerable zone which can be distinguished from the concept of fire vulnerable area in previous studies. The results of this study can be used to analysis fire-fighting vulnerable zone type analysis, establish fire-fighting policies and improve the performance of decision-making process.

A Study on the Resilience of Fire-fighters: Analysis of the Moderating Effect on the Relationship between Job Stress, Job Burnout, and Job Satisfaction (소방공무원 회복탄력성에 대한 연구: 직무스트레스와 직무소진, 직무만족 간 영향관계에서의 조절효과 분석)

  • Lee, Jae-Moo;Kim, Jun-Soo
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.10
    • /
    • pp.690-701
    • /
    • 2021
  • This study examines the effects of job stress on fire-fighters' job performance on negative job factors, job burnout, and positive job factors, job satisfaction, respectively, and by examining whether resilience has a modulating effect in these influence relationships. This was done to provide useful information for planning management strategies. The analysis was done by regression analysis of data collected through a structured survey of 239 fire-fighters, and the moderating effect was confirmed by calculating and applying the interaction term. For the analysis, a structured questionnaire survey was conducted on 239 fire-fighters. As a result of the analysis, it was confirmed that job stress and job burnout of fire-fighters were low, job satisfaction was normal, and resilience was above average. Also, there was no significant difference in resilience according to demographic characteristics, and it was found that job stress had a positive(+) influence on job burnout at a statistically meaningful level, and a negative(-) influence on job satisfaction. In addition, it was found that impulse control power and cause analysis power had a moderating effect in the influence relationship between job stress and job burnout, and impulse control power had a moderating effect in the influence relationship between job stress and job satisfaction. Based on these results, it was proposed to preemptively apply various resilience programs suitable for the situation of fire-fighters, enhance emotional competence, and introduce coaching personnel to help self-reflection.

A survived case after 150J defibrillation and CPR were performed for out-of-hospital infant cardiac arrest (병원 전 영아 심정지 환자에서 150J 제세동과 심폐소생술 시행 후 생존한 1례)

  • Yun, Hyeong-Wan;Hong, Soo-Mi;Jeon, Yoon-Chul;Lee, Jae-Min
    • The Korean Journal of Emergency Medical Services
    • /
    • v.17 no.3
    • /
    • pp.53-60
    • /
    • 2013
  • Purpose: The purpose of the study is to emphasize the importance of out-of-hospital cardiac arrest resuscitation. This resuscitation by paramedic is very effectively performed under the medical direction of the doctors. Methods: The cardiac arrest victim was 4 month old infant. Informed consent from the parents of the infant was received. CPR combined with 150J defibrillation was performed to the 4 month old infant. Results: We reported that the 4 month old infant survived the cardiac arrest. Out-of-hospital cardiac arrest infant survived after 150J automated external defibrillator and CPR performance. Conclusion: Specific operative protocol is important because the paramedic can apply the proper manual defibrillator effectively. It is important to extend the work scpoe of the EMT.