• Title/Summary/Keyword: Fire facility

Search Result 447, Processing Time 0.03 seconds

Using AHP to Develop a Rehabilitation Room Management Model for Fire Officers at Disaster Sites (재난현장 소방공무원의 회복실 운영모델 개발)

  • Yim, Dong-Kyun;Chae, Jin
    • Fire Science and Engineering
    • /
    • v.34 no.4
    • /
    • pp.115-124
    • /
    • 2020
  • The purpose of this study was to provide an operational model of the rehabilitation room for fire officers at disaster sites to improve the safety and resilience of fire officers. Therefore, we analyzed the operation related elements of the rehabilitation room-such as overseas rehabilitation room operation cases and previous studies- and managed different factors including, but not limited to, management and human resources, equipment and facility, and accessibility and convenience factors; afterward, the relative importance and importance of sub-layers in each field were measured. The priority of items for the operation of the rehabilitation room for fire officers at disaster sites was elucidated; after expert analysis, it was found that human resources were the most crucial factor. Finally, it was found that, in descending order, accessibility and convenience, administrative, equipment, and facility factors were also essential. Based on this, we proposed a rehabilitation room operation guideline for disaster sites.

Water Jet Experiment of Automatic Fire-tracking Water Cannon Facility combined with Indoor Hydrant Facility in Road Tunnels (도로터널의 옥내소화전설비 겸용 자동화점추적 방수총설비의 방수실험)

  • Kim, Chang-Yong;Kong, Ha-Sung
    • Fire Science and Engineering
    • /
    • v.33 no.1
    • /
    • pp.92-98
    • /
    • 2019
  • To determine if water-jet nozzle moves and water jetting are effective according to the location of the fire, this study examined the automatic fire-tracking water cannon system and aan indoor hydrant system, such as water jet centered directivity, water jet range maintainability and water jet shape uniformity. First, an examination to find the center of fire accurately from this system design showed that the water jet centered test was accurate. Second, the water jet range test results showed that when water is jetted at the maximum water jet radius, the water jet shows an inaccurate result but within the allowable tolerance range. Finally, the water-jet shape test result confirmed that there are no problems in setting the block from the algorithm design.

Method of Determining Future Facility Location with Maintaining Present Accessibility

  • Takahagi, Wataru;Sumitani, Yasushi;Takahashi, Hirotaka;Omae, Yuto;Sakai, Kazuki
    • Industrial Engineering and Management Systems
    • /
    • v.15 no.3
    • /
    • pp.197-205
    • /
    • 2016
  • The public services closely related to the daily lives of the Japanese people, such as firefighting, police or primary school education, are largely financed by the local governments. As the population as a whole in Japan declines, the population in local regions are forecasted to experience particularly rapid decline in the future, and it is inevitable to reduce the cost of public services provided by the local governments to keep their financial basis sustainable. In order to provide public services to the people properly and fairly, the local governments own and utilize their public facilities, such as fire stations, police stations or primary schools. On the other hand, we have to secure the accessibility, which is the condition of accessing a facility easily in a whole local city including the high population density area and low population density area. In this paper, we propose a method of determining the number of future facilities and its facility locations in which we maintain the present accessibility. In our proposed method, we determine them comparing the accessibility measurement calculated by facility location model using the present and future population. We adopted k-centdian model as the facility location model, which can secure the accessibility in a whole local city determining the weights of both areas. We applied our proposed method to fire station in Iwaki city, Japan. The results suggested that 7 facilities would be reduced in 2064, after 50 years from 2014. Additionally, we confirmed that the future facility location had secured accessibility in both high and low population density area.

Analysis of Air Quality and the Management Plan for Exposure to Hazardous Substances in the Garage of a Fire Station (소방청사 차고지 공기질 분석 및 유해물질 노출 관리 방안)

  • Park, Je-Seop;Han, Dong-Hun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.30 no.4
    • /
    • pp.394-404
    • /
    • 2020
  • Objectives: The aims of this study are to derive the characteristics of diesel exhaust gas emissions generated during vehicle checking in the garage of fire stations and of the related improvement plans for proper air quality management. Methods: The researcher measured changes in the air quality inside garages according to the operating conditions of the exhaust facility and before and after vehicle checking at three fire stations. Results: During the checking of fire engines, a large volume of hazardous substances exceeding management standards were generated, and improvement of the discharge facilities was required for proper air quality management. Conclusions: It is necessary to study the hazard evaluation of firefighters' exposure to exhaust gas, to operate exhaust gas ventilation facilities, and to prepare technical standards for proper indoor air quality management.

An Exploratory Study on 3D-based Building Information Management for Multi-User Fire Protection System

  • Kim, Dahee;Cha, Heesung
    • International conference on construction engineering and project management
    • /
    • 2022.06a
    • /
    • pp.1162-1169
    • /
    • 2022
  • As buildings become more and more complicated, the importance of developing and managing facility management information is increasing. In a building fire situation, various information is generated and needed to be quickly shared among participants. However, the current fire response system fails to monitor the relevant information in a real time basis. This study aims to develop a system prototype for fire protection management which can quickly and accurately manage and effectively deliver the pertinent information to the target participants. The research contributes to the efficiency of fire protection endeavors by interpreting both dynamic and static fire information in an appropriate manner.

  • PDF

Development of User-centered Fire Safety Evaluation Model for School Buildings (교육시설의 사용자 중심 화재안전수준 평가모형 개발)

  • Park, Sung-Chul;Kim, Jin-Wook
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.238-239
    • /
    • 2021
  • This study presented the development of a user centered school facility fire safety evaluation model that would support fire safety evaluation, which is globally recognized as being important in terms of school safety, to be more efficiently implemented in the school field mainly by students. The study consisted of five steps. First, actual condition survey tools were developed based on the major fire safety evaluation items derived through literature review. Second, the characteristics of domestic school facilities in terms of fire safety were developed using the survey tools. Third, an evaluation model at a level utilizable by students was developed based on the foregoing characteristics. Fourth, the applicability of the model was verified through a trial application of the model to elementary school students. Finally, legal and institutional improvement plans and fire safety education materials were presented through a policy proposal.

  • PDF

A Study on the Application of Fire Risk Assessment Index on the Wooden Cultural Properties -focused on buddhist temples- (목조 건축문화재의 화재위험도 평가지표 및 활용방안 연구 -사찰 건축물을 중심으로-)

  • Kang, Seok-Jin;Ko, Myong-Hwan;Kim, Dong-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.7
    • /
    • pp.3550-3561
    • /
    • 2013
  • The purpose of this study was to propose the categorized checklist for fire risk assessment on the wooden cultural properties and to carry out field survey. The survey checklist was composed of categories such as management and administration measures(management, training and countermeasure), architectural planning measures(site plan and facility plan), and equipment measures(fire-fighting and crime prevention facility). In this study, the field survey was carried out in the Nae-jang-sa and Wha-um-sa and it was found that there were some problems in the items which were assessed importantly by experts.

A Study on Factors Affecting Fire Prevention (화재예방에 영향을 미치는 요인에 관한 연구)

  • Chae, Jin
    • Fire Science and Engineering
    • /
    • v.34 no.3
    • /
    • pp.100-109
    • /
    • 2020
  • This study aims to empirically verify the factors affecting fire prevention, which is a dependent variable, by establishing a safety culture related to fire prevention, fire prevention education, fire prevention equipment, fire safety knowledge, and fire safety practices as independent variables. The results obtained from the multiple regression analysis were derived as follows in relation to fire prevention. The fire prevention education was found to have the most statistically significant effect on fire prevention, and the fire prevention facility was found to have a statistically significant effect on fire prevention. In addition, fire safety practice was found to have a statistically significant effect on fire prevention.