• Title/Summary/Keyword: Fire facilities

Search Result 835, Processing Time 0.027 seconds

A Study on the Facility and Equipment of Laboratory Medicine in General Hospital - Focused on more than 550 bed sized hospitals (종합병원 진단검사의학과 검사실의 시설 설비 현황 조사 - 550 병상 이상 종합병원을 중심으로)

  • Kim, Youngaee;Song, Sanghoon
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.26 no.1
    • /
    • pp.73-84
    • /
    • 2020
  • Purpose: Though Korean healthcare services have been upgraded, infection and fire had been broken out in general hospitals. And higher concerns about quality assessment made it to clinical laboratory design guideline studies. So, this study investigates the facilities, equipment and personnel of laboratory medicine focusing on more than five hundred fifty bed hospital, and contributes to make guidelines for safety and efficiency in lab. Methods: Questionnaires to supervisor technologist and field surveys to medical laboratories in korean hospitals have been conducted for the data collection. 16 answers have been analysed statistically by MS Excel program. Results: Most of the sample tests such as hematology, clinical chemistry, immunology, transfusion, urinalysis, microbiology and molecular diagnosis are performed by more than 80% in large sized general hospital laboratory. In the test methods, automatic analyzers are used up to 80%, total laboratory automation up to 43% in clinical chemistry and immunology, and manual tests in all sorts of the test. There are placed in single lab or two and three labs above the ground, which are all in semi-open lab. There is some correlation with the number of specimens and the number of lab people depending on the number of hospital beds. Laboratory environment shows that work distance is good, but evacuation path width, visibility, separation of staff area from automatic analyzer, and equipment installations are needed to have more spaces and gears. Most of the infection controls are equipped with mechanical ventilation, air-conditioning, washbasin and wastewater separation, BSC installation and negative pressure lab room. Implications: Although the laboratory space area is calculated considering the number of hospital beds, type of tests and number of staff, hospital's expertise and the samples numbers per year should be taken into account in the planning of the hospital.

Radiological Safety Assessment of Transporting Radioactive Wastes to the Gyeongju Disposal Facility in Korea

  • Jeong, Jongtae;Baik, Min Hoon;Kang, Mun Ja;Ahn, Hong-Joo;Hwang, Doo-Seong;Hong, Dae Seok;Jeong, Yong-Hwan;Kim, Kyungsu
    • Nuclear Engineering and Technology
    • /
    • v.48 no.6
    • /
    • pp.1368-1375
    • /
    • 2016
  • A radiological safety assessment study was performed for the transportation of low level radioactive wastes which are temporarily stored in Korea Atomic Energy Research Institute (KAERI), Daejeon, Korea. We considered two kinds of wastes: (1) operation wastes generated from the routine operation of facilities; and (2) decommissioning wastes generated from the decommissioning of a research reactor in KAERI. The important part of the radiological safety assessment is related to the exposure dose assessment for the incidentfree (normal) transportation of wastes, i.e., the radiation exposure of transport personnel, radiation workers for loading and unloading of radioactive waste drums, and the general public. The effective doses were estimated based on the detailed information on the transportation plan and on the radiological characteristics of waste packages. We also estimated radiological risks and the effective doses for the general public resulting from accidents such as an impact and a fire caused by the impact during the transportation. According to the results, the effective doses for transport personnel, radiation workers, and the general public are far below the regulatory limits. Therefore, we can secure safety from the viewpoint of radiological safety for all situations during the transportation of radioactive wastes which have been stored temporarily in KAERI.

Developed Stand alone PMS for ESS Safety Operation (ESS 안전 운영을 위한 독립형 PMS 개발)

  • Oh, Hong-Geun;Kim, Chul-Won
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.2
    • /
    • pp.351-360
    • /
    • 2019
  • Recently, the use of ESS facilities has been increased under the government's energy policy and at the same time, the various accident incidents such as fire and explosion occurred. Currently the ESS is installed as integrated ESS which includes PMS(: Power Management System), However, when the accident occurs, this system has high possibilities of losing the data due to oxidization, and the administrator cannot respond promptly. Therefore, in this paper, by constructing a separate WAS and data storage, it is possible to separate the main functions of the conventional system, to enable external EMS operation, and at the same time to quickly respond to the cause and cause of the accident occurrence. We will propose the development of a standalone PMS that is possible to respond.

Integrated Management System to Improve Photovoltaic Operation Efficiency (태양광발전 운영효율 향상을 위한 통합관리시스템)

  • Yoon, Yongho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.4
    • /
    • pp.113-118
    • /
    • 2019
  • A solar power plant is a facility that produces electricity. As the risk of fire and electric shock accidents is diversified, the risk of workers, surrounding people, and facilities is increased, preventing safety accidents and promptly responding to safety accidents Is emerging. In light of the necessity of such development, it is necessary to develop a solar power generation management system that can diagnose and maintain the problems of the power generation system in real time by developing technologies for collecting and analyzing the data produced by the solar power generation system As a result, the utilization rate and the maintenance cost can be reduced. In order to do this, it is necessary to accurately predict the solar power generation amount in the present state, to diagnose the abnormality of the current power generation state and to grasp the abnormal position, and to use the model considering economical efficiency when the abnormal position is grasped, And the time and other information should be provided.

Injury Severity Analysis of Truck-involved Crashes on Korean Freeway Systems using an Ordered Probit Model (순서형 프로빗 모형을 적용한 고속도로 화물차 사고 심각도)

  • Kang, Chanmo;Chung, Younshik;Chang, Yoo Jin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.39 no.3
    • /
    • pp.391-398
    • /
    • 2019
  • In general, truck-involved crashes increase severity in terms of both injury level and crash impact level. Recently, although the frequency and fatality of truck-involved crashes in Korea are rising, their associative studies are very limited. Therefore, the objective of this study is to identify critical factors influencing on injury severity of truck-involved crashes on Korean freeway system. To carry out this objective, this study uses an ordered probit model (OPM) based on a 6-year crash dataset from 2012 to 2017. From the analysis, eight variables were found to have a great effect on injury severity: older driver, crash speed, rear-end collision, number of vehicles involved, drowsy driving, nighttime (0:00 to 6:00) driving, overturn or rollover, and vehicle's fire after crash. However, injury severity was less severe in crashes under snowy condition and crashes to traffic facilities (i.e., crash alone).

Study on Policy Improvement Measures to Respond to Infectious Diseases of Livestock through Field Investigation (현장 조사를 통한 가축전염병 대응 정책개선 방안 연구)

  • Park, Hyun Shik;Ham, Seung Hee;Lee, Jun
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.2
    • /
    • pp.275-288
    • /
    • 2021
  • Purpose: The purpose of this study is to analyze the characteristics of animal carcasses treatment and quarantine management of infectious diseases of livestock, and to present the effectiveness of quarantine and follow-up management of livestock infectious diseases. Method: Actually, a livestock epidemic occurred and the burial site and burial management facility that treated livestock carcasses were visited on-site to analyze the management status and problems. Result: The burial method of livestock outbreaks of livestock infectious diseases and the long-term follow-up management accordingly requires a large amount of manpower and budget to be spent. For example, it can be seen that it is an inefficient quarantine system. Conclusion: It is necessary to review plans for the establishment of integrated livestock infectious animal carcasses treatment facilities at the level of metropolitan cities, districts, and municipalities with the government, where there is no fear of secondary infectious disease transmission and no follow-up management is required.

Optimization of Gas Detector Location by Analysis of the Dispersion Model of Hazardous Chemicals (유해화학물질의 확산 모델 분석을 통한 가스감지기 위치 최적화)

  • Jeong, Taejun;Lim, Dong-Hui;Kim, Min-Seop;Lee, Jae-Geol;Yoo, Byung Tae;Ko, Jae Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.2
    • /
    • pp.39-48
    • /
    • 2022
  • The domestic gas detector installation standards applied to gas detectors, which are one of the facilities that can prevent accidents such as fire, explosion, and leakage that can cause serious industrial accidents, do not take into account the behavioral characteristics of hazardous chemicals in the atmosphere. It can be seen that the technical basis is insufficient because the standard is applied. Therefore, in this study, the size of the leak hole for each facility mainly used in chemical plants and the diffusion distance according to the concentration of interest of hazardous chemicals were analyzed, and based on this, the optimal installation distance for gas detectors for each material was suggested. Using the method presented in this study, more economical and effective gas detector installation can be expected, and furthermore, it can be expected to help prevent serious industrial accidents.

A Study on the Formation Process of the Former Kanegafuchi Spinning Gwangju Factory (구 종연방적 광주공장의 형성 과정에 관한 조사연구)

  • Cheon, Yeol-Hong;Lee, Hyang-Mi
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.24 no.4
    • /
    • pp.133-139
    • /
    • 2022
  • This study deals with the formation of Jongyeonbangjeok's Gwangju Factory in the 1930's to 80's, and the findings are shown below: In the period of formation, the factory was rectangular-shaped from north to south, and the structure was located at the center of the site, and in the east of it, there was a dormitory connected from south to north. The building was arranged with an open area on the south. In the east of the site where company houses were located, same-sized structures were arranged along the axis.In the period of change, the factory was restored about the damage from the Korean War, and it went through the process of division into two companies. As a result, the factory in the center of the site was divided into left and right ones, and the dormitory and the group of company houses were, too, divided into two, so division was made largely into southern and northern parts. In the period of stabilization, along with factory extension in each of the companies, welfare for factory workers was expanded by building more houses or opening sport facilities. After the 1980's, too, the existing factories were either extended or remodeled according to the induction of equipment, and some showed changes in their functions due to a fire or such.

A Study on the Response Technique for Toxic Chemicals Release Accidents - Hydrogen Fluoride and Ammonia - (독성 화학물질 누출사고 대응 기술연구 - 불산 및 암모니아 누출을 중심으로 -)

  • Yoon, Young Sam;Cho, Mun Sik;Kim, Ki Joon;Park, Yeon Shin;Hwang, Dong Gun;Yoon, Jun heon;Choi, Kyung Hee
    • Korean Journal of Hazardous Materials
    • /
    • v.2 no.1
    • /
    • pp.31-37
    • /
    • 2014
  • Since the unprecedented hydrogen fluoride leak accident in 2012, there has been growing demand for customized technical information for rapid response and chemical accident management agencies including the Ministry of Environment, the National Emergency Management Agency, and the National Police Agency need more information on chemicals and accident management. In this regard, this study aims to provide reliable technical data and guidelines to initial response agencies, similar to accident management technical reports of the US and Canada. In this study, we conducted a questionnaire survey and interviews on initial response agencies like fire stations, police stations, and local governments to identify new information items for appropriate initial response and improvements of current guidelines. We also collected and reviewed the Canada's TIPS, US EPA's hydrogen fluoride documents, domestic and foreign literature on applicability tests of control chemicals, and interview data, and then produced items to be listed in the technical guidelines. In addition, to establish database of on-site technical information, we carried out applicability tests for accident control data including ① emergency shut down devide, safety guard, shut down valve, ground connection, dyke, transfer pipe, scrubber, and sensor; ② literature and field survey on distribution type and transportation/storage characteristics (container identification, valve, ground connection, etc.); ③ classification and identification of storage/transportation facilities and emergency management methodslike leak prevention, chemicals control, and cutoff or bypass of rain drainage; ④ domestic/foreign analysis methods and environmental standards including portable detection methods, test standards, and exposure limits; and ⑤ comparison/evaluation of neutralization efficiency of control chemicals on toxic substances.

Element Technology and Strategy of Digital Twin in the Water Treatment (수처리공정의 디지털 트윈 요소기술과 추진 전략)

  • Young-Man Cho;Yong-Jun Jung
    • Journal of Wetlands Research
    • /
    • v.25 no.4
    • /
    • pp.284-290
    • /
    • 2023
  • Domestic water supply and sewage facilities are rapidly aging and maintenance difficulties such as aging of operation and management personnel are overlapping, so Digital Twin technology is attracting attention as an intelligent means of process management. Digital twin projects for domestic water treatment processes include the smart sewage treatment project promoted by the Ministry of Environment, projects independently promoted by some local governments, and digital twin purification plant projects promoted by K-water. However, the content of digital twin promotion is different for each institution. Therefore, in the water treatment process, technological standardization and step-by-step implementation methods for digital twins must be preceded to reduce trial and error in future business promotion. This study aims to provide an efficient promotion plan by prescribing the digital twin element technology and composition method in the water treatment process and reviewing the contents currently being promoted by the Ministry of Environment, local governments, and K-Water individually.