• Title/Summary/Keyword: Fire facilities

Search Result 842, Processing Time 0.021 seconds

Sleep Quality and Associated Factors Among Firefighters in Bangkok, Thailand: A Cross-sectional Study

  • Nunnapat Piyachaiseth;Pornchai Sithisarankul;Jate Ratanachina
    • Journal of Preventive Medicine and Public Health
    • /
    • v.57 no.1
    • /
    • pp.83-90
    • /
    • 2024
  • Objectives: Professional firefighters face various health hazards and are required to maintain both physical and mental fitness to effectively mitigate crises and respond to emergencies. Moreover, the long working hours and shift work of this profession impact sleep quality. This study investigated the quality of sleep and its associated factors among firefighters in Bangkok, Thailand. Methods: This was a cross-sectional study of firefighters affiliated with the Bangkok Fire and Rescue Department, Bangkok Metropolitan Administration, Thailand between January 2023 and March 2023. A cluster random sampling technique was utilized to distribute 600 questionnaires to firefighters in 15 fire stations. The questionnaire addressed demographic, work-related, and environmental factors. Sleep quality was assessed using the Thai version of the Pittsburgh Sleep Quality Index (PSQI). Data analysis involved both descriptive and inferential statistics. Bivariate and multiple logistic regressions were performed. Results: The response rate was 78.7% (n=472), and 44.1% of the firefighters reported poor sleep quality (PSQI score >5). Sleep quality was statistically associated with conflicting family relationships (odds ratio [OR], 1.8; 95% confidence interval [CI], 1.1 to 2.9), additional part-time jobs (daytime, OR, 2.4; 95% CI, 1.3 to 4.4; or nighttime, OR, 4.3; 95% CI, 1.1 to 16.7), noisy sleeping areas (OR, 1.7; 95% CI, 1.1 to 2.8), and the availability of adequate bedding (OR, 3.0; 95% CI, 1.8 to 4.9). Conclusions: Poor sleep quality among firefighters was associated with various personal, work-related, and environmental factors. Organizations should promote policies that improve sleep quality through good sleep hygiene practices and facilities.

A Study on Safety and Operational Management System for CNG Filling Stations (CNG충전소 안전.운영 관리를 위한 시스템 구축에 관한 연구)

  • Yang, Jae-Mo;Kim, Bum-Su;Yong, Jong-Won;Ko, Byung-Seok;Lee, Dong-Hyuk;Ko, Jae-Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.6
    • /
    • pp.8-13
    • /
    • 2011
  • All over the nation, a lot of industrial complex utilize gas as their energy source. Possibilities are fire, explosion, and leakage could happen any time in these large complexes. To prevent these tragic accidents and to minimize the damage when the accident occurs, the development of diagnostic technology for these facilities is imperative. The safety check is conducted on an individual and partial basis, currently. Accordingly, the accumulation and improvement of the safety management technology is necessary in order to make all the different checking techniques and management systems compatible, since checking processes, result interpretation techniques, and subsequent prognoses are not the same. The program provides damage scenarios from gas leakage. The output enables policy makers to predict the degree of infliction. Through this program, engineers are able to design an effective gas safety program to operate and maintain ubiquitous gas facilities.

Study on the Prevention of Corrosion Damage for Underground Fuel Stroage Tank(1) (Corrosion Damage under the Sea Sand) (지하연료저장탱크의 부식손상 방지에 관한 연구(1) (바다모래에서 부식 손상))

  • 임우조;서동철
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.37 no.1
    • /
    • pp.65-70
    • /
    • 2001
  • As consumption rate of energy increase rapidly, the facilities of fuel storage tank become large size. Almost all of the industry or public facilities storing fuel in underground fuel storage tank is manufactured by steel materials. Thus, this fuel storage tank made of steel materials is damaged by stray-current corrosion, it become destruction. If fuel storage tank is destructed, petroleum, oil and gas are leaked. So it bring about environmental pollution, energy loss, fire and explosion. Therefor, in this study, for study on the prevention of corrosion damage in underground fuel storage tank, it were investigated by corrosion and stray-current corrosion for SS 400 in dry sea sand and wet sea sand along to specific resistance. The main results obtained are as follows : As specific resistance decrease in wet sea sand, corrosion rate per year increase linearly, in case of back fill up wet sea sand in underground fuel storage tank, if the water is flow into dry sea sand, corrosion tendency of underground fuel storage tank is supposed sensitive.

  • PDF

Composition Principle of Seo-Won Architecture from the View of Its Disposition and Korean Traditional Thought (전통사상(專統思想)과 서원건축배치(書院建築配置)의 구성(構成) 원리(原理))

  • Park, Jeomg-Hae;Han, Dong-Soo
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.18 no.6
    • /
    • pp.33-43
    • /
    • 2011
  • The Korean academics of classical learning, Seowon which from the middle of Joseon Dynasty was complexly reflected in "the illustration of Taiji(太極圖說)" Five-Elements school(陰陽五行說), "Zhou Yi(周易)" and a theory on spherical heaven and square ground(天圓地方) which based on orientalism. Also the theory of Xiangshu Xue(象數學) was a significant factor to decide the size(number of facade module) of Seowon architecture. So, in this study, how the oriental thought was adopted and reflected in existing 21 Seowon in South Korea. The size of Seowon architecture was adopted a theory of combination with heaven, earth and human(天地人三合論) that based on the theory of Xiangshu Xue on "the illustration of Taiji" and "Zhou Yi". "Zhou Yi" was the central thought of Confucian culture in Joseon Dynasty, with which Seowon space was divided into two, ancestral rites space and lecture space. It coincides with balance of yin(陰) and yang(陽), Five-Elements(五行) and four seasons(四季節). In lecture space, lecture hall is relevant with the water(水) and winter, and front tower structure or outer three-door is the fire(火) and summer. Also, central garden means the soil(土) and center. Thus, the size and spatial composition was planned with the philosophy, "the illustration of Taiji", Five-Elements school and a theory on spherical heaven and square ground. Yin and yang has an idea of the heaven and earth, and Five-Elements has an idea of direction and season with which spatial composition of Seowon could be set. And the numeral meaning on the theory of Xiangshu Xue established an ideal background for spatial composition of Seowon architecture.

  • PDF

A Monitoring System for Working Environments Using Wireless Sensor Networks (무선 센서 네트워크를 이용한 작업환경 모니터링 시스템)

  • Jung, Sang-Joon;Chung, Youn-Ky
    • Journal of Korea Multimedia Society
    • /
    • v.12 no.10
    • /
    • pp.1478-1485
    • /
    • 2009
  • A sensor network which is composed of a large number of sensors that perform various sensing is applied in a variety of fields. The sensor networks can be widely used for various application area like as home automation, fire detection and security area. Development of new sensor to have appropriate functions and deployment of networks for suitable application are served actively. In this paper, we design and implement a system that monitors various factory facilities by deploying sensor network at a working place which threatens the worker's safety. A sensor node reports its sensing data like as temperature and humidity to monitor facilities to a sink node. And the server which is connect to the sink node gathers and provides information by user interface. In addition, digital data which are generated at a work place can be transferred via the sensor network to increase the efficiency of works. The proposed sensor network provides the convenience of working, since it is deployed at a garbage collection company to monitor a temperature and humidity of garbage and to transmit data about the weight of trucks which enters the company.

  • PDF

Analysis of Traffic Crash Severity on Freeway Using Hierarchical Binomial Logistic Model (계층 이항 로지스틱모형에 의한 고속도로 교통사고 심각도 분석)

  • Mun, Sung-Ra;Lee, Young-Ihn
    • International Journal of Highway Engineering
    • /
    • v.13 no.4
    • /
    • pp.199-209
    • /
    • 2011
  • In the study of traffic safety, the analysis on factors affecting crash severity and the understanding about their relationship is important to be planning and execute to improve safety of road and traffic facilities. The purpose of this study is to develop a hierarchical binomial logistic model to identify the significant factors affecting fatal injuries and vehicle damages of traffic crashes on freeway. Two models on death and total vehicle damage are developed. The hierarchical structure of response variable is composed of two level, crash-occupant and crash-vehicle. As a result, we have gotten the crash-level random effect from these hierarchical structure as well as the fixed effect of covariates, namely odds ratio. The crash on the main line and in-out section have greater damage than other facilities. Injuries and vehicle damages are severe in case of traffic violations, centerline invasion and speeding. Also, collision crash and fire occurrence is more severe damaged than other crash types. The surrounding environment of surface conditions by climate and visibility conditions by day and night is a significant factor on crash occurrence. On the orher hand, the geometric condition of road isn't.

Development of Integrated Public Address System for Intelligent Building (지능형 빌딩을 위한 디지털 통합 전관 방송 시스템 개발)

  • Kim, Jung-Sook;Song, Chee-Won
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.21 no.2
    • /
    • pp.212-217
    • /
    • 2011
  • In this paper, we developed an intelligent minimized integrated digital public address which can provide context awareness of various events occurring in future intelligent buildings. It is able to recognize both voices and sounds, such as a fire bell and a disaster bell, which signal to escape in emergence situations and it can sense information which is sent from various sensors, for example, the inner temperature, humidity, and environment status in an intelligent building. Also, the intelligent digital integrated public address can broadcast information to individual places, according to context awareness that is from sensing information, by using network with an ID. And we are developing a minimized integrated digital public address system that has facilities such as external input, Mic., CD, MP3 and Radio. Developing an integrated digital public address system with operational MICOM will make it possible to control the facilities of digital devices centrally. The operational MICOM is composed of 3 layers which are a control layer, a processing layer and a user interface layer.

Causal Analysis of Education Function Space Parameters of University Dormitory (대학기숙사 교육기능공간의 매개변수를 통한 인과분석)

  • Park, Hang-Ja;Park, Sung-Jin;No, Young-Ran
    • Journal of the Korean housing association
    • /
    • v.21 no.4
    • /
    • pp.23-31
    • /
    • 2010
  • This study aims to examine the educational function space of university dormitories at local universities with corridor centered structure in Honam area regions based on direct and indirect parameters on the whole satisfaction of users in residential environment factors and personal characteristics. First, according to relations among parameters, educational and cultural activities of four major activities within the dormitory had indirect influences on social activities, eating and sleeping activities had no direct influence on other activities. And social activity had direct influence on the general satisfaction as an important parameter and educational and cultural activities had indirect influence on the whole satisfaction through social activities. Detailed results show that, in the first educational activities directly affecting the lighting and air conditioning facilities (0.22), safety (0.326), Territoriality (0.327), the space density (-0.167), directions (-0.166) and yeohyang having personal characteristics and the safety of the second cultural activities (0.183), Territoriality (0.361), Aesthetics (-0.13) and the personal characteristics Sex (-0.179), the direct effect, third, and erosion has a direct impact on activity The flexibility of the space factor (-0.128) and Territoriality (0.38) and the personal characteristics grade (0.172), respectively. Fourth in social activities directly affecting the pathfinding (-0.104), and parameter, education (0.388) and cultural activities (0.445), and some of the factors affecting the indirect lighting and air conditioning facilities, safety, and Territoriality, the space density, directions, grade, they could influence through educational activities to be analyzed. That is, territoriality in educational function space is the important factor that users react very sensitively in educational, eating and sleeping activities and educational function space must secure area and division considering personal and public use as the space accommodating activity which is lacking in unit residential space. Accordingly, the safety of educational function space in university dormitory is considered as the fundamental safety matter on the fire prevention, hygiene and cleanness for users in the satisfaction of educational and cultural activities.

A Preliminary Study on the Improvement of Safety Level from Disasters in Rural Area (농촌지역의 재난발생에 따른 안전도 향상을 위한 기초연구)

  • Koo, Wonhoi;Shin, Hojoon;Baek, Minho
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.3
    • /
    • pp.393-399
    • /
    • 2015
  • In this study, the history of disaster occurrence in rural area was reviewed and damage characteristics were analyzed in order to improve the safety level according to the occurrence of disasters in non-urban area (rural area). Also, the concept of regional disaster prevention was adopted to rural area and the basic direction for establishing a disaster safe village in rural area was set. Due to the characteristics of rural area, the population and the number of households in the rural area were small, and the rural area showed lack of various disaster safety facilities and infrastructures and limitation in the access to the outside due to its geographical characteristics. Therefore, the matters regarding the direction for establishing and operating a regional disaster safe village reflecting humanities, facilities, infrastructures, and geographical and environmental characteristics were summarized.

Risk Assessment of 30 MeV Cyclotron Facilities (30 MeV 사이클로트론 시설 위험성 평가)

  • Jeong, Gyo-Seong;Kim, Chong-Yeal;Lee, Jin-Woo
    • Journal of Radiation Industry
    • /
    • v.11 no.1
    • /
    • pp.39-45
    • /
    • 2017
  • A cyclotron is a kind of particle accelerator that produces a beam of charged particles for the production of medical, industrial, and research radioisotopes. More than 30 cyclotrons are operated in Korea to produce $^{18}F$, an FDG synthesis at hospitals. A 30-MeV cyclotron was installed at ARTI (Advanced Radiation Technology Institute, KAERI) mainly for research regarding isotope production. In this study, we analyze and estimate the items of risk such as the problems in the main components of the cyclotron, the loss of radioactive materials, the leakage of coolant, and the malfunction of utilities, fires and earthquakes. To estimate the occurrence frequency in an accident risk assessment, five levels, i.e., Almost certain, Likely, Possible, Unlikely, and Rare, are applied. The accident consequence level is classified under four grades based on the annual permissible dose for radiation workers and the public in the nuclear safety law. The analysis of the accident effect is focused on the radioactive contamination caused by radioisotope leakage and radioactive material leakage of a ventilation filter due to a fire. To analyze the risks, Occupation Safety and Health Acts is applied. In addition, action plans against an accident were prepared after a deep discussion among relevant researchers. In this acts, we will search for hazard and introduce the risk assessment for the research 30-MeV cyclotron facilities of ARTI.