• Title/Summary/Keyword: Fire extinguishing agent

Search Result 100, Processing Time 0.031 seconds

Experimental Study to Estimate the Required Flow of Fire Extinguishing System for Flame Spread Prevention on Composite Panel (복합패널 화재확산 방지를 위한 소화시스템의 소요유량 산정을 위한 실험적 연구)

  • Park, Byoung-Jik;Shin, Hyun-Jun;Yoo, Yong-Ho;Park, Jin-Ouk;Kim, Hwi-Seong;Kim, Yang-Kyun
    • Fire Science and Engineering
    • /
    • v.31 no.6
    • /
    • pp.33-39
    • /
    • 2017
  • Composite panel refers to the particular plywood produced in a way of stacking the different kinds of material in sandwich form and adhering them using adhesives and is widely used as building material for its constructability and cost efficiency. But as the surface is finished with steel plate, fire extinguishing agent cannot reach to the core material because of such steel plate on surface which causes the difficulties in suppressing the fire as well as in fire-fighting activities due to collapse. This study, to deal with such problem, is intended to set the fire pipe in core material to prevent the fire from spreading and in a bid to achieve this using minimized fire water, water supply test device was fabricated to estimate the required water flow of fire extinguisher and consequently, optimal water flow (0.5 L/min) was determined through a full-scale fire test.

A Study on Corrosion of the HFC-125 fire extinguishing agent for Metal and Non-Ferrous Metal (HFC-125 소화약제의 금속 및 비철금속 부식성 평가에 관한 연구)

  • Lee, Chang-Woo;Ham, Eun-Gu;Yoo, Ju-Yeol;Seo, Sang-Hun;Kim, Gin-Sung;Cho, Yong-Sun
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2016.11a
    • /
    • pp.271-274
    • /
    • 2016
  • 본 논문에서는 오존층 파괴 및 지구 온난화에 악영향을 미치는 할로겐화합물 소화약제를 대체하여 개발된 청정소화약제인 할로겐화합물 청정소화약제(Halocarbon clean agent)의 열분해 생성물(thermal decomposition products)의 영향에 평가하고자 한다. 이를 위해 할로겐화합물 청정소화약제인 HFC-125가 화원 크기의 변화에 따른 열분해 생성물의 미치는 영향을 측정하기 위해 소화시험을 실시하였고 금속(철), 비철금속(구리), 유리 시편의 부식성과 전자부품(SD-Card) 작동여부를 평가 하였다. 금속 및 비철금속 시편의 부식성을 측정하기 위해 디지털 카메라를 통해 이미지를 촬영하고 그래픽 편집 소프트웨어를 이용하여 채도(saturation)를 측정하여 부식성의 정도를 분석하였다. 금속, 비철금소, 유리 시편의 부식성 분석 결과, 화원의 크기가 증가할수록 금속 및 비철금속의 부식성이 증가하였다. 즉, 화원의 크기(fire size)에 따라 열분해 생성물질도 증가하여 금속 및 비철금속의 부식을 증가시키는 것으로 사료된다.

  • PDF

Study on the effective response method to reduce combustible metal fire (금속화재 위험감소 방안에 관한 이론적 연구)

  • Nam, Ki-Hun;Lee, Jun-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.12
    • /
    • pp.600-606
    • /
    • 2018
  • A class D fire or combustible metal fire is characterized by the presence of burning metals. Only certain metals or metal compounds are flammable, including sodium and lithium. General fire extinguishing agents, such as dry chemical powder, water-based fire extinguish agents, and carbon dioxide, cannot be used in class D fires. This is because these agents cause adverse reactions or are ineffective. In addition, the amount of usage of combustible metals is increasing due to continuous development of the semiconductor and fuel cell industries. Despite this, Korea does not have standards and laws related to combustible metal fires. This paper suggests directions of the class D fire management policies to reduce the class D fire risk and impact by analyzing the standards and laws related to class D fires and combustible metal fire cases. The factors to make laws on class D fire prevention and response systems, and management system of dry sand were determined. These results may be used to help reduce the risk of class D fires and improve the response abilities.

A Numerical Simulation of the Effect of the Injection Angle and Velocity of the $CO_2$ Agent Nozzle on the Characteristics of $CO_2$ Concentration Distribution ($CO_2$ 소화제 노즐 분사각 및 분사속도가 $CO_2$ 농도분포특성에 미치는 영향에 관한 수치적 연구)

  • Park, Chan-Su
    • Fire Science and Engineering
    • /
    • v.20 no.2 s.62
    • /
    • pp.44-53
    • /
    • 2006
  • We have conducted a numerical simulation under two-dimensional unsteady conditions in order to analyze the effect according to the injection angle and velocity of the $CO_2$ agent nozzle which is one of the elements for the fixed type $CO_2$ fire extinguishing system installed in a ship on the characteristics of flow and $CO_2$ concentration distribution. The flow fields and concentration fields were measured and analyzed. We can found that the difference of flow patterns according to the conditions of $CO_2$ agent injection nozzle, and in all the conditions of $CO_2$ agent injection nozzle, the iso-concentration line was expanded from the region at which vortex was generated to the surroundings. We can expected that the intensity of the wall jet on the bottom floor was generated differently and the iso-concentration lines were expanded or shrunk according to the angle of $CO_2$ agent injection nozzle. In case of increasing $CO_2$ agent injection velocity maintaining the flow quantity of the $CO_2$ agent injection equally, the iso-concentration line of $CO_2$ agent on bottom floor can be formed more higher than in case of decreasing $CO_2$ agent injection velocity.

A Numerical Study on the Extinguishing Effects of CO2 in Counterflow Diffusion Flames with the Concept of Local Application System (국소방출방식 개념의 대향류 확산화염에서 CO2 소화효과에 관한 수치해석 연구)

  • Mun, Sun-Yeo;Park, Chung-Hwa;Hwang, Cheol-Hong;Oh, Chang-Bo
    • Fire Science and Engineering
    • /
    • v.26 no.4
    • /
    • pp.55-62
    • /
    • 2012
  • The suppression mechanisms of carbon dioxide ($CO_2$) as a representative fire suppression agent were revisited using a counterflow diffusion flame which could be applied the concept of a local application system. To end this, the low strain rate $CH_4$/air counterflow diffusions with $CO_2$ addition in either fuel or oxidizer stream were examined numerically using detailed-kinetic chemistry. Radiative heat loss due to radiating gas species including $CO_2$ added was considered by the optically thin model (OTM). As a result, the critical $CO_2$ volume fractions in the oxidizer stream required to extinguish the flame were in good agreement with the experimental data reported in the literature, while somewhat under-prediction was observed with $CO_2$ added in the fuel stream. The surrogate agents were adopted to estimate the quantitative contribution with changing in global strain rate ($a_g$) on the flame extinguishment among pure dilution effect, thermal effects including radiation heat loss and chemical effect due to the $CO_2$ fire suppression agent.

Adsorption of Metal Ions on Synthetic Resin with Styrene Hazardous Materials in Water Fire Extinguishing Agent (물 소화약제에서 스타이렌 위험물을 포함한 합성수지에 의한 금속 이온들의 흡착)

  • Lee, Chi-Young;Kim, Joon-Tae
    • Applied Chemistry for Engineering
    • /
    • v.21 no.2
    • /
    • pp.142-147
    • /
    • 2010
  • Cryptand resins have been synthesized from 1-aza-18-crown-6 macrocyclic ligand attached to styrene (2th petroleum in 4th class hazardous materials) divinylbenzene copolymer with crosslinkage of 1%, 2%, 10%, and 18% by substitution reaction. The synthesis of these resins was confirmed by the content of chlorine, element analysis, surface area (BET), and IR-spectroscopy. The effects of pH, time and crosslinkage on adsorption of metal ion from water fire extinguishing agentby synthetic resin adsorbent were investigated. Metal ions showed a great adsorption over pH 3 and adsorption equilibriumof metal ions was about two hours. The adsorption selectivity determined in water was in the increasing order of sodium ($Na^{1+}$) > zinc ($Zn^{2+}$) > chromium ($Cr^{3+}$) ion. The adsorption was in the order of 1%, 2%, 10%, and 18% crosslinkage resin.

Research on the Rheological Properties of Aqueous Film Forming Foam to Respond to Ship Oil Fires (함정 유류화재 대응을 위한 수성막포의 유변학적 특성 연구)

  • Kil-Song Jeon;Hwi-Seong Kim;Jung-Hoon You;Yong-Ho Yoo;Jin-Ouk Park
    • Applied Chemistry for Engineering
    • /
    • v.34 no.6
    • /
    • pp.603-607
    • /
    • 2023
  • Aqueous film forming foam (AFFF) is a critical fire suppression agent used in combating hydrocarbon fires. This type of fire suppressant is highly effective due to its ability to form a protective film, dissipate heat, inhibit combustion, and utilize a blend of chemical substances to extinguish fires. While these properties offer significant advantages in responding to hydrocarbon fires, AFFF is distinct in its deployment as it is dispensed in the form of foam. Therefore, the rheological analysis of AFFF foam using a rheometer plays a crucial role in predicting the spray characteristics of AFFF for combating hydrocarbon fires, and this is closely associated with effective fire suppression. In this study, we conducted rheometer experiments to confirm the non-Newtonian behavior (shear-thinning) of AFFF foam and obtained data on the form's stability. These experimental data are expected to contribute to enhancing the efficiency of fire suppression systems utilizing AFFF.

Comparison of the Physical Properties for Alternative Eire Extinguishing of Pure and Mixture Component of Inert Gases (불활성가스계 단일 성분 및 혼합물 성분의 대체 소화제의 물성 비교)

  • 김재덕;이광진;한순구;이윤우;노경호
    • Fire Science and Engineering
    • /
    • v.18 no.2
    • /
    • pp.12-19
    • /
    • 2004
  • The commercially available IG-541 extinguished agent composed of inert gases was developed for environmental protection. The extinguished agents were considered in terms of physical properties, efficient characteristic, environment, stability, and economical efficiency. The pure and mixture components of physical properties of $N_2$, Ar and $CO_2$ were chosen and compared. The physical properties of density, viscosity and surface tension of inert gases were plotted with the molar ratios of $N_2$/$CO_2$ and Ar/$CO_2$ in terms of a temperature. The extinguished agent in the composition of $N_2$, Ar and $CO_2$, 50/40/10 (mol %) showed relatively high density, low viscosity and moderate surface tension, therefore it was suitable for the alternative extinguished agents.

Numerical study on the foam spraying for AFDSS applicable to initial fire suppression in large underground spaces (지하대공간 초동 화재진압에 적용가능한 자율형 소화체계의 폼 분사 해석 기법 연구)

  • Park, Jinouk;Yoo, Yongho;Kim, Whiseong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.23 no.6
    • /
    • pp.503-516
    • /
    • 2021
  • Autonomous fire detection and suppression system requires advanced technology for complex detection technology and injection/control technology for accurate hitting by fire location. Also, foam spraying should be included to respond to oil fires. However, when a single spray monitor is used in common, water and foam spray properties appear different, so for accurate fire suppression, research on the spray trajectory and distance will be required. In this study, experimental studies and numerical analysis studies were combined to analyze the foam spray characteristics through the spray monitor developed for the establishment of an autonomous fire extinguishing system. For flow analysis of foam injection, modeling was performed using OpenFOAM analysis software, and the commonly used foaming agent (Aqueous Film-Forming Foam) was applied for foam properties. The injection distance analysis was performed according to the injection pressure and the injection angle according to the form of the foam, and at the same time, the results were verified and presented through the injection experiment.

Recommendation of an Occupational Exposure Limit and Legal Control Following an Acute Hepatotoxicity Incident from HCFC-123 (HCFC-123의 급성 독성간질환 발생 사례에 따른 노출기준 및 법 관리 필요성 권고)

  • Lee, Kwon Seob;Jo, Ji hoon;Choi, Bo Kyung;Lee, Hye Lim;Byeon, Sang Hoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.28 no.1
    • /
    • pp.80-90
    • /
    • 2018
  • Objectives: This study was performed to propose a domestic occupational exposure limit(OEL) following a health hazard assessment, calculation of a non-carcinogenicity reference concentration worker($RfC_{worker}$) value, and examination of international agencies' exposure limits. It also recommends legal management within the Occupational Safety and Health Act for HCFC-123, which caused an acute hepatotoxicity incident. Methods: An acute hepatotoxicity incident due to the fire extinguishing agent HCFC-123 was investigated. Toxicological hazard and health hazard classifications were examined and a non-carcinogenicity $RfC_{worker}$ value was calculated for HCFC-123. An OEL and the necessity of legal management were recommended as well. Results and Conclusions: An OEL for HCFC-123 of 10 ppm($62.5mg/m^3$), which considered the $RfC_{worker}$ value, 5.56 ppm, produced in dose-response assessment and the exposure level of 19.1-20.9 ppm measured as an eight-hour TWA(time-weighted average) in the incident place, is recommended. HCFC-123 is urged to be included as a chemical requiring legal management in the Occupational Safety and Health Regulations. In addition, it is recommended that a peak exposure of ACGIH be adopted in the Notice of the Ministry of Employment and Labor.