• 제목/요약/키워드: Fire explosion

검색결과 637건 처리시간 0.032초

Methyl Ethyl Ketone Peroxide의 위험성을 판단하기 위한 자연발화, 인화점 및 폭발거동에 관한 기초 연구 (A Study of Characteristics such as Spontaneous Ignition, Flash Point and Explosion Behavior of Methyl Ethyl Ketone Peroxide in ender to Determine its Hazardousness)

  • 정두균;최재욱;이인식;임우섭;김동규
    • 한국안전학회지
    • /
    • 제20권3호
    • /
    • pp.78-83
    • /
    • 2005
  • In this study, the evaluate characteristics of fire and explosion of MEK-PO are subjected to spontaneous ignition, flash point and explosion hazard. The minimum ignition temperature and instantaneous ignition temperature for MEK-PO were $188.5^{\circ}C\;and\;230^{\circ}C\;at\;225{\mu}L$. In addition The flash point for MEK-PO was obtained at $49^{\circ}C$. Furthermore, the maximum explosion pressure and the maximum explosion pressure rising velocity: using MCPVT (mini cup pressure vessel tester) were $10.82kgf/cm^2\;and\;33.72kgf/cm^2{\cdot}s$.

활성탄의 부유중 폭발 위험성에 관한 연구 (A Study on the Explosion Riskiness with Flying of Activated Carbon)

  • 김정환;현성호;이창우;함영민
    • 한국화재소방학회논문지
    • /
    • 제12권3호
    • /
    • pp.3-9
    • /
    • 1998
  • 순수 활성탄과 홉착제로 사용된 동종의 폐활성탄 분진의 온도에 따른 열적 안정성을 조사하기 위 하여 열중량 분석기(TGA)를 이용하여 온도에 따른 무게감량을 조사하고 이들의 입도별 비표면 적을 측정하여 동일한 입도를 갖는 순수 활성탄과 폐활성탄 분진의 비표면적 변화에 따른 분진폭 발 특성을 살펴보고자 하였다. 분진폭발 시험 장치로는 압축공기에 의해 분진을 강제 분산시킨 후 전기 점화원에 의해 분진의 폭발성을 측정하는 Hartman 식 측정장치를 이용하여 순수 활성 탄과 폐활성탄 분진의 입도별로 분진의 농도를 변화시켜가며 분진폭발실험을 행하였다. 실험 결 과 업도가 작을수록 분진폭발압력이 크며 동일한 입도에서 폐활성탄에 비해 비표면적이 3-4배 정도 큰 순수 활성탄이 상대적으로 분진폭발 발생이 용이하며 폭발압력 또한 높은 것으로 나타 났다.

  • PDF

프로필렌의 공정안전 운전을 위한 CO2 첨가량에 따른 폭발범위 측정에 관한 연구 (A Study on the Measurement of Explosion Range by CO2 Addition for the Process Safety Operation of Propylene)

  • 최유정;허종만;김정훈;최재욱
    • 한국산학기술학회논문지
    • /
    • 제20권7호
    • /
    • pp.599-606
    • /
    • 2019
  • 위험물질에 의한 제조물을 취급하는 설비와 시설은 대부분 고온, 고압으로 공정을 운전을 한다. 이로 인해 화재폭발로 인한 위험성이 증대되고 있다. 특히, 폭발 사고는 석유 화학 가스설비 등 위험물 시설의 가장 주된 위험요인으로 작용하고 있으며, 그 중, 프로필렌은 석유화학 플랜트의 기초 원료 및 첨가 중합반응에 의한 합성물질을 제조하는 현장에서 많이 사용되고 있다. 산소농도의 변화에 대한 폭발범위를 구함으로써 프로필렌을 사용하는 사업장에서 발생 될 수 있는 폭발을 예방하기 위하여 불활성 가스인 $CO_2$를 이용하여 온도와 압력의 변화에 따라 산소농도의 변화에 대한 폭발범위를 구하였다. 온도는 $25^{\circ}C$, $100^{\circ}C$, $200^{\circ}C$로 변화시켜 측정하였으며, 용기 내 압력을 $1.0kgf/cm^2.G$, $1.5kgf/cm^2.G$, $2.0kgf/cm^2.G$, $2.5kgf/cm^2.G$$CO_2$를 가압시켜 측정하였다. 폭발한계는 온도, 압력 및 산소농도와 관계가 있으며, 온도와 압력이 높아질수록 최소산소농도는 낮아지고, 산소농도가 낮아질수록 폭발범위는 좁아졌다. 또한, 최소산소농도 이하의 농도에서는 프로필렌의 증기와 점화원이 존재하여도 폭발이 발생하지 않는 것을 알 수 있다.

화재 실험을 통한 에어컨 실내기의 화염확산에 관한 현상학적 연구 (A Phenomenological Study on the Flame Spread of Air Conditioner Indoor unit by Fire Tests)

  • 최승복;이승훈;최민기;최돈묵
    • 한국화재소방학회논문지
    • /
    • 제27권6호
    • /
    • pp.89-96
    • /
    • 2013
  • 본 연구의 목적은 연소 실험을 통하여 에어컨 실내기의 화염확산에 관한 형상을 관찰하여 화재원인 및 발화지점을 확인하기 위함이다. 본 실험은 화염이 주변으로부터 에어컨 상단에 옮겨 붙는다는 것을 가정하여 실내기 상단을 n-햅탄을 적신 천으로 착화시켰으며, 동일한 조건으로 2회의 반복실험을 하였다. 착화 후 559 s와 734 s 사이에 실내기와 연결된 냉매관이 파열되면서 내부에 충입되어 있던 냉매와 함께 윤활유가 커다란 폭음을 내며 고온 고압의 화염이 급격히 분출되었으며 연소 잔류물을 확인한 결과, 증발기 일부와 모터, 금속함 등을 제외한 대부분은 소실되었다. 에어컨 자체에서 발화되었을 경우와 외부 화염에 의해 소훼되었을 경우 배선의 합선흔적 위치는 유사하였다. 따라서 연소 잔류물의 형상만으로 발화원인과 지점을 특정 짖는 것은 불확실하다는 것을 확인하였다.

국내 제조업 화재감시자 운영의 문제 확인 및 개선방안 (Identification of Problems and Improvement Measures of Fire Observer Operation in Domestic Manufacturing Industry)

  • 김경민;서용윤;이종빈;장성록
    • 한국안전학회지
    • /
    • 제38권6호
    • /
    • pp.26-35
    • /
    • 2023
  • Sparks cause most fire and explosion accidents in the manufacturing industry during hot work, which ignites surrounding combustible materials. Such incidents lead to high casualties due to suffocation from toxic gases and lack of evacuation. Therefore, the government recently enacted and revised 'The Occupational Safety and Health Act' to prevent fires and explosions at work sites, incorporating legal standards for fire observers, which are important in preventing accidents and the spread of fire during hot work. However, there are notable shortcomings in conducting professional cause analysis of these accidents and in aligning them with advanced foreign legal standards. Additionally, there is a lack of literature review reflecting the manufacturing industry characteristics. Despite the recent enactment and revision of legal standards, gathering sufficient opinions and professional reviews remains insufficient. To address these gaps, interviews were conducted with safety and health workers, analyzing recent fire and explosion causes in domestic manufacturing industries, and reviewing both domestic and international legal standards. Conclusively, proposed improvement measures were centered on the professionalization of fire observer education, enhancing their roles and authority realistically, and improving fire observer placement and operation standards. Consequently, additional 'Occupational Safety and Health Act' standards are necessary for fire observer education and defining the government's role. Second, precise legal standards outlining the role and authority of fire observers are required. Third tailored fire observer arrangements and management standards appropriate for varying work characteristics and company sizes are required. This study emphasizes the importance of supplementing relevant legal standards to prevent fire accidents in the manufacturing industry.

밀가루분진 및 살리실산분진의 폭발하한농도 및 열적특성 비교에 관한 연구 (A Study on the Comparison of Explosive Lower Limit Concentration & Thermal Specific of Wheat Powder Dust & Salicylic Acid Dust)

  • 고재선
    • 한국화재소방학회논문지
    • /
    • 제26권4호
    • /
    • pp.1-9
    • /
    • 2012
  • 본 연구에서는 중소기업형의 밀가루 제조공정 및 각질제거용 기능성 비누를 생산하는 화장품 제조공정에서의 분진들을 채집하여 폭발 및 열적특성을 비교하기 위해 실험을 수행하였다. 폭발실험은 Hartman식 분진폭발장치를 이용하였고, 열적실험은 DSC 및 TGA를 이용하여 활석첨가시 농도의 변화에 따른 폭발압력 및 폭발하한계와 온도에 따른 무게감량과 흡열량을 측정하였다. 폭발실험결과 두 시료 모두 활석분진의 비율이 증가할수록 폭발하한농도가 증가하는 것을 볼 수 있었고, 폭발압력은 감소됨을 확인하였다. 그리고 DSC 실험결과 활석의 첨가량이 증가할수록 열유속은 감소하고 온도 또한 약간의 감소상태인 것으로 분석되었다. 또한 두 시료 모두 승온 속도가 증가 할수록 흡열개시온도가 낮은 온도부분으로 이동하고 있으며, 흡열량도 크게 증가하였다. 아울러 TGA 실험결과 활석의 양이 증가할수록 전체 무게감량이 줄어드는 것으로 나타났다. 향후 분진폭발메커니즘의 지속적 연구와 보완이 효과적인 분진폭발예방 대책수립에 기여할 것으로 기대된다.

화재조사 관련 교과목의 확대와 개편의 필요성에 관한 연구 (A Study on Necessity of Expansion and Reorganization of Courses Related to Fire Investigation)

  • 최진만;김길환;이창우;최돈묵
    • 한국화재소방학회논문지
    • /
    • 제25권3호
    • /
    • pp.42-50
    • /
    • 2011
  • 화재조사 분야에서 국가 및 사회로부터 요구되는 전문 인력을 효과적으로 양성하고 소방관련학과 졸업자들의 취업분야를 확대하기 위해서는 기존의 화재조사 관련 교과목의 확대 및 개편이 필요하다. 현재 화재조사론이 개설된 대학은 30%에 불과하며 교육내용도 이론분야에 치우쳐 있기 때문에 실제현장에서 요구되는 전문적인 지식을 제공하는데 한계가 있다. 따라서 본 연구에서는 화재조사 분야의 교과목을 화재조사론 및 화재감식론으로 세분화하고 국제화재폭발조사관 자격 (CFEI)도 취득할 수 있을 정도의 표준화된 교육과정 및 교수요목에 대한 방안을 제시했다.

열매체유 시스템의 안전관리 실태에 관한 연구 (A Study on the Actual Conditions of Safety Management in Thermal Oil System)

  • 이주엽;이근원;우인성
    • 한국안전학회지
    • /
    • 제29권5호
    • /
    • pp.60-66
    • /
    • 2014
  • Depending on the progress of the industrial advances, the use of the thermal oil system in the utility system has been increased, which became an important part in the operation of the plant. However, fire or explosion have occurred due to lack of risk awareness and safety management, more frequently than we know. In this study, by using a questionnaire, actual conditions of safety management in thermal oil system is surveyed and analyzed, it is composed of general, a safety status of the thermal oil system component and the stage of recognition and management in the thermal oil system. These results of this study can be used as basic data to the safety management and the accident prevention of fire or explosion in the workplace.

가스충전소에서 작업복의 정전기 안전관리에 관한 연구 (A Study on the Safety Management of the Electrostatic in Working Clothes at the Gas Station)

  • 이금환;정재희
    • 한국안전학회지
    • /
    • 제24권6호
    • /
    • pp.39-44
    • /
    • 2009
  • In order to prevent fire and explosion due to the electrostatic discharge at the Gas Station etc. This result will be applied to standard in the future. Wearing the non-electrostatic removing wear, Charged voltage of human body is 3,980V(MIE is approximately 0.79mJ). There is a possibility of fire explosion because the MIE of LP gas is 0.25mJ. In accordance with using period(whasing times), Charged voltage is shown that propensity is increased. Electrostatic charge amount is upper standard($0.6{\mu}$C) of the hazard of electrostatic removing wear. There is a possibility of fire and explosion. Therefore, countermeasure and management are needed about gas station worker.

LNG 재기화 공정에서 LNG 누출에 따른 화재 및 폭발사고의 피해영향 분석 (Analysis of the Impact of Fire and Explosion Accidents due to LNG Leaks in the LNG Re-gasification Process)

  • 이윤호
    • 해양환경안전학회지
    • /
    • 제24권6호
    • /
    • pp.825-833
    • /
    • 2018
  • 본 연구에서는 LNG 공급계통시스템의 재기화 공정에서 배관 손상으로 인한 누출사고 발생시 LNG 성분 및 누출공의 크기에 따른 연소특성에 대한 피해범위를 산출하고, 피해영향을 해석하였다. LNG 성분에 따른 연소특성을 확인하기 위하여 7곳의 LNG 산지별 위험도를 확인한 결과 산지별 큰 차이를 보이지 않았으나, LNG 구성성분 중 메탄의 함유량이 많을수록 플래시화재 발생범위 및 증기운 폭발에 의한 과압이 발생하는 위험범위 그리고 제트화재 발생에 의한 열 복사량 피해영향이 다른 산지에 비해 비교적 낮음을 알 수 있었다. 또한 배관 누출공의 크기에 따라 누설, 파공, 파괴 3단계에 나누어 위험 범위 및 폭발에 미치는 영향에 대한 연구를 수행하였으며, 플래시화재로 인한 피해영향범위를 계산하고, 이에 따라 LNG 누출시 화재가능 위험범위를 확인했으며, 과압의 영향 및 복사열로 부터의 피해범위를 예측할 수 있었다. 이를 통해 LNG 조성 및 배관 누출공의 크기가 화재 및 폭발에 미치는 영향을 예측할 수 있었다.