• 제목/요약/키워드: Fire engine

검색결과 216건 처리시간 0.024초

항공기 구조용 소방차 탱크룸의 구조 안정성 평가 및 설계 개선에 대한 해석적 연구 (An Analytical Study on Structural Stability Evaluation and Design Improvement of Fire Truck Water Tank for Aircraft Rescue)

  • 권혁진;강명철;임수일;김한욱;홍정기;이호;황영선
    • 드라이브 ㆍ 컨트롤
    • /
    • 제20권1호
    • /
    • pp.1-7
    • /
    • 2023
  • In this study, the structural stability of the tank room of an aircraft rescue fire engine is to be studied. The tank room of the aircraft rescue fire engine is filled with fire extinguishing water and chemicals. Fire extinguishing water and chemical are filled to a capacity of about 12.5 tons and are subjected to high stress. The tank room is made of PP material with low yield stress. Structural analysis of the tank room is performed and structural weakness is analyzed. In addition, if a structural problem occurs as a result of structural analysis, an analysis simulation result is presented to derive an improved design and to show the validity of the structural stability of the tank room.

자동차의 블랙박스 와이어링 화재 위험성에 관한 연구 (A Study on the Fire Risk of Black Box Wiring in Motor Vehicle)

  • 강신동;김주희;최준표;김재호
    • 한국안전학회지
    • /
    • 제32권6호
    • /
    • pp.22-28
    • /
    • 2017
  • According to the National Fire Data System (NFDS), more than 5,000 vehicle fires have occurred every year for the last 10 years. Vehicle fires are primarily caused by mechanical (breaking system and engine), electrical (wiring and battery), and chemical (oil and fuel gas leakage) problems. The electrical factor has increased with the installation of driver convenience equipment. For example, today, the black box is widely used to provide video data recording of motor vehicle accidents. The black box consists of a front camera, rear camera, and wires. The black box wires are directly connected to the junction box or fuse box from the start battery that operates to provide normal on power supplying for engine stop. It is extremely dangerous when the wires short circuit due to insulation aging, mechanical and electrical stress, etc. In this study, the black box wiring fire risk have been analyzed and investigated when the steady state and abnormal operations, and under the following conditions: wiring arrangements with a high temperature condition, insulation aging, poor contact, and short circuits. The results showed that black box wiring short circuits had a higher fire risk than the other fire hazard elements. To prevent fire hazards caused by black box wiring, the black boxes must be installed by qualified service personnel. Do not modify the wiring, remove the fuse and secure the wiring using cable ties or insulation tape.

Reverse uni-flow 소기방식을 갖는 2행정 프리피스톤 수소기관의 역화 현상에 관한 연구 (The Characteristics of Backfire for a Free-Piston Hydrogen Fueled Engine with Reverse Uni-flow Scavenging)

  • 변창희;조관연;백대하;이종태
    • 한국수소및신에너지학회논문집
    • /
    • 제21권2호
    • /
    • pp.98-103
    • /
    • 2010
  • In order to develop two-stroke free-piston hydrogen engine to obtain high thermal efficiency and low emission, backfire occurrence have to be prevented. In this research, backfire characteristics are analyzed as functions of the intake valve opening timing and compression chamber pressure under piston by using RICEM (Rapid Intake Compression Expansion Machine) that has reverse uni-flow scavenging. As the result, reverse uni-flow scavenging is advantage about back fire. but, it exists suitable intake valve opening timing and its timing become known that equivalence ratio 1 retard until the piston rises. Also, To rise chamber pressure of lower piston, this does not cause backfire occurs in equivalent ratio 0.6 observed back fire. Therefore, 2cycle hydrogen fueled free-piston engine is undesirable scavenging compression by compressing the piston.

자동차 흡배기장치, 발전기 튜닝 및 배기측 인화성 물질 유입에 관련된 화재사례 연구 (Fire Examples Study of Intake and Exhaust System, Alternator Tuning and Inflow of Inflammables on Exhaust Part in a Car)

  • 이일권;국창호;서문원;유창배;염광옥;임춘무;정동화
    • 한국가스학회지
    • /
    • 제18권5호
    • /
    • pp.47-51
    • /
    • 2014
  • 이 논문은 자동차 흡배기 장치, 발전기 튜닝 및 배기 측 인화성 물질 유입에 관련된 화재에 대한 사례를 분석하고 연구하는 것이다. 첫 번째 사례는, 흡기와 배기 장치의 튜닝한 상태에서 자동차의 시동을 켜 놓고 정차된 상태에서 가연성 스티로폼이 자동차 하체로 유입되고, 배기 열에 의해 불이 붙었고, 이 열원에 누설된 연료가 화재를 확대시킨 것으로 확인되었다. 두 번째 사례는 실내의 오디오 시스템을 튜닝하고 필요한 전기의 양을 증대하기 위해 발전기 용량을 높임으로써 발전기와 연결된 배선이 과열되어 화재가 발생된 것으로 확인되었다. 세 번째 사례의 원인은 정비사가 오일을 교환한 다음 플라스틱 용기로 된 깔때기를 엔진 내부에 둔 것이 엔진의 배기열에 의해 화재가 발생된 것으로 확인되었다. 따라서, 엔진의 흡배기 시스템과 발전기 시스템을 개조하지 않도록 하여야 하며, 자동차를 수리할 때나 점검할 때 배기측에 이물질이 유입되어 화재가 발생하지 않도록 자동차의 관리에 세심한 주의를 하여야 한다.

건축물 화재발생시 사용되는 재난치안용 무인기의 내열성 환경시험 (Public Safety & Security Unmanned Aerial Vehicle Heat resistance Environmental Test used in case of Building Fire)

  • 김다경;방홍순;김옥규
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 봄 학술논문 발표대회
    • /
    • pp.119-120
    • /
    • 2020
  • Recently, a building fire has occurred due to various influences. Accordingly, we are developing an public safety & security unmanned aerial vehicle for fire prevention and initial response to fire. The public safety & security unmanned aerial vehicle is used to grasp the traffic route to enter the fire engine in the event of a fire in a dense structure and to determine the scale of the fire and the area of danger of collapse around the fire site. In this study, an environmental test of the public safety & security unmanned aerial vehicle's heat resistance was performed in an environment simulating a fire scene.

  • PDF

우리나라 중요목조문화재의 효과적 화재진압을 고려한 기본특성분석에 관한 연구 (The study of basic quality analysis for an effective fire suppression of the main temple properties in Korea)

  • 정은지;신호준;이지향;김정호;백민호
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 추계학술논문발표회 논문집
    • /
    • pp.471-478
    • /
    • 2008
  • This study grasps the type and site area of properties, the size of properties, the distance between the wooden properties and fire station, the direction of a fire engine in the wooden properties, the member of self-protection, and the present condition of fire fighting. And the 121 main temples properties in Korea is researched for an effective fire suppression.

  • PDF

화재화염이 유동 및 $CO_2$소화제 전달특성에 미치는 영향 (The Effect of Fire Plume on the Characteristics of Air Flow and $CO_2$Extinguishant Transfer)

  • 박찬수;최주석
    • 한국화재소방학회논문지
    • /
    • 제16권4호
    • /
    • pp.33-43
    • /
    • 2002
  • 선박기관실과 유사한 공간내로 $CO_2$소화제를 분사했을 때 화재화염이 공기유동 및 $CO_2$소화제전달 특성에 미치는 영향을 분석하기 위하여 수치해석을 수행하였다. 노즐 위치에 따라 유동장과 $CO_2$농도장을 계산하였다. 한 경우를 제외한 모든 경우에서 시계방향과 반시계방향 재순환 유동이 노즐 좌, 우측영역에 형성되었으며, 이러한 재순환 유동이 질량전달과 $CO_2$소화제 확산경로에 큰 영향을 미치는 것을 알 수 있었다. 화재화염이 위치한 1층 영역에서는 $CO_2$소화제 확산경로가 재순환 유동 확장경로와 일치하였다.

화재위치에 따른 $CO_2$소화제 전달특성 (The Transfer Characteristics of $CO_2$ Extinguishant According with the Location of Fire Plume)

  • 박찬수;최주석
    • 한국화재소방학회논문지
    • /
    • 제17권4호
    • /
    • pp.28-35
    • /
    • 2003
  • 선박기관실과 유사한 공간에 $CO_2$ 소화제를 방사하였을 때 화재위치에 따른 $CO_2$ 소화제 전달특성을 분석하기 위하여 전산묘사연구를 수행하였다. 화재위치를 변화시키면서 유동장과 농도장을 계산하였으며, 실험결과 화재화염위치가 유동패턴과 $CO_2$소화제 질량전달특성에 지배적인 영향을 미치는 것으로 나타났다. 1층과 2층으로 구성된 기관실의 2층 중앙 좌측영역에 화재화염이 위치하는 경우에는 에어 커턴과 같은 효과가 화재가 발생한 영역에서 나타났고, 이 영역으로의 질량전달을 방해하였다. 높이에 따른 특성에서는 1, 2충 중앙 좌측영역에 화재가 위치한 경우, $CO_2$소화제가 완전히 분사된 후에도 이 영역에 소화가능한계 이하의 등농도선이 형성되었다. 따라서 본 연구결과들은 $CO_2$소화장치 설비 시 $CO_2$소화제 분사노즐을 배열하는데 고려되어져야 할 것으로 생각된다.

소형선박 기관실의 자연발화 방지를 위한 환기조건에 관한 연구 (A Study on the Ventilation Conditions for the Prevention of Spontaneous Combustion of Small Ship Engine Room)

  • 박찬수
    • 한국화재소방학회논문지
    • /
    • 제22권4호
    • /
    • pp.11-19
    • /
    • 2008
  • 소형선박 기관실의 자연발화 방지를 위한 적합한 환기조건을 제시하기 위하여 급, 배기구 수와 위치를 변화시키면서 나타나는 유동장과 온도장을 CFD시뮬레이션을 수행하여 분석하였다. 급, 배기구 수와 위치에 따라 유동형태가 상이하게 나타났으며, 배기구를 천장에 배치시킬 경우는 세로대칭선에 대해 좌우 측천장의 중앙에 위치하는 것이 열 제거에 더 효과적임을 알 수 있었다. 급, 배기구 수를 증가시킬 때는 배기구수를 증가시키는 것이 더 적합한 환기조건이며, 소형선박 기관실의 자연발화방지에 가장 적합한 환기조건은 급기구는 가로대칭선에 대해 전후 측 천장의 중앙에, 배기구는 양측 벽 중앙에 배치시키는 경우로 예측되었다.

청각장애인을 위한 웨어러블 기기의 위험소리 검출 엔진 설계 (A Design of Dangerous Sound Detection Engine of Wearable Device for Hearing Impaired Persons)

  • 변성우;이석필
    • 전기학회논문지
    • /
    • 제65권7호
    • /
    • pp.1263-1269
    • /
    • 2016
  • Hearing impaired persons are exposed to the danger since they can't be aware of many dangerous situations like fire alarms, car hones and so on. Therefore they need haptic or visual informations when they meet dangerous situations. In this paper, we design a dangerous sound detection engine for hearing impaired. We consider four dangerous indoor situations such as a boiled sound of kettle, a fire alarm, a door bell and a phone ringing. For outdoor, two dangerous situations such as a car horn and a siren of emergency vehicle are considered. For a test, 6 data sets are collected from those six situations. we extract LPC, LPCC and MFCC as feature vectors from the collected data and compare the vectors for feasibility. Finally we design a matching engine using an artificial neural network and perform classification tests. We perform classification tests for 3 times considering the use outdoors and indoors. The test result shows the feasibility for the dangerous sound detection.