• Title/Summary/Keyword: Fire effects

Search Result 851, Processing Time 0.114 seconds

A Two-Stage Stochastic Approach to the Artillery Fire Sequencing Problem (2단계 추계학적 야전 포병 사격 순서 결정 모형에 관한 연구)

  • Jo, Jae-Young
    • Journal of the military operations research society of Korea
    • /
    • v.31 no.2
    • /
    • pp.28-44
    • /
    • 2005
  • The previous studies approach the field artillery fire scheduling problem as deterministic and do not explicitly include information on the potential scenario changes. Unfortunately, the effort used to optimize fire sequences and reduce the total time of engagement is often inefficient as the collected military intelligence changes. Instead of modeling the fire sequencing problem as deterministic model, we consider a stochastic artillery fire scheduling model and devise a solution methodology to integrate possible enemy attack scenarios in the evaluation of artillery fire sequences. The goal is to use that information to find robust solutions that withstand disruptions in a better way, Such an approach is important because we can proactively consider the effects of certain unique scheduling decisions. By identifying more robust schedules, cascading delay effects will be minimized. In this paper we describe our stochastic model for the field artillery fire sequencing problem and offer revised robust stochastic model which considers worst scenario first. The robust stochastic model makes the solution more stable than the general two-stage stochastic model and also reduces the computational cost dramatically. We present computational results demonstrating the effectiveness of our proposed method by EVPI, VSS, and Variances.

The Influence on the Stack Effect with the Opening of Smoke Ventilators in High-rise Buildings (초고층 건축물에서 배연창 개방이 연돌효과에 미치는 영향)

  • Lim, Chae-Hyun;Kim, Bum-Gyue;Yeo, Yong-Ju;Park, Yong-Hwan
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.209-213
    • /
    • 2008
  • The effects on the performance of natural smoke exhaust ventilators installed in high-rise buildings were analyzed depending on the wind velocities and smoke temperatures using CONTAMW tool. The results showed that the smoke exhaust ventilators can maintain given performances in such conditions as low smoke temperatures and low wind velocities. However, high smoke temperatures and high wind velocities can prevent the smoke ventilators to exhaust smokes from the fire room. Significant changes in stack effects in high-rise buildings can also occur with the opening of smoke ventilators in the fire floor.

  • PDF

An Experimental Study of Fire Suppression Using a Water Mist in a Compartment (물분무를 이용한 화재제어에 관한 실험적 연구)

  • Kim, Sung-Chan;Park, Hyun-Tae;Ryou, Hong-Sun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.3
    • /
    • pp.367-373
    • /
    • 2003
  • The present study investigates the fire suppression characteristics using a water mist fire suppression system. The fire extinguishing times are measured for various fire sources, fuel types, and different total flooding rates of water mist. Pool fire with hydrocabon fuel is successfully extinguished within a minute under the operating conditions of the water mist system. Two different regimes of the smoke layer cooling are observed, such as rapid and slow cooling processes. The regimes are divided by threshold time which is calculated with auto-correlation function. The threshold time for the initial cooling decreases with increasing water flow-rates and fire sources. These initial cooling effects play an important role in preventing the occurance of flashover fire by the initial fire suppression.

An Experimental Study on Characteristics of the Residential Container Building Fire (주거용 컨테이너 화재 특성에 관한 실험적 고찰)

  • Lee, Jung-Yun;Jung, Ki-Chang;Kim, Hong
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.1
    • /
    • pp.24-27
    • /
    • 2008
  • The recent fire incident in an elementary school of Chonan city causes the media focus on the fire safety of residential container buildings. In this study, real fire tests were conducted in this kind of buildings. Fire temperature and radiant heat flux were measured, in order to investigate the hazard-reduction effects during the fire emergency of residential container buildings. According to the test results, flash over occur in 10 minutes, peak fire temperature was $935.5^{\circ}C$, peak radiant heat flux was $24.99kW/m^2$ at 8minutes after residential container building fire.

Numerical study on the post-earthquake fire behavior of intermediate steel moment frames

  • Parvizizadeh, Shayan;Kazemi, Mohammad Taghi
    • Earthquakes and Structures
    • /
    • v.22 no.2
    • /
    • pp.137-145
    • /
    • 2022
  • As steel is highly sensitive to temperature variations, fire exposure is more destructive in the case of steel structures in comparison to the concrete ones. The performance of an intermediate three-story steel moment frame with 4 spans was studied under the service load, thermal load and post-earthquake fire in this paper. Also, the effects of passive fire-protection materials such as ordinary cement-based and fire-retardant coatings were investigated. To model and analyze the structure; Abaqus software is utilized. In order to apply the earthquake effect, the push-over analysis method is employed. Changes in the stories deflection, endurance time and growth of nonlinear regions due to losses in the steel stiffness and strength, are among the issues considered in this study. As an interesting finding, the beams protected by ordinary cement-based coating could sustain the fire exposure at least for 30 minutes in all cases. The mentioned time is increased by employing a new fire-retardant protection, which could prevent significant loss in the structure resistance against fire, even after 60 minutes of exposure to fire.

Effects of Forest Fire on Soil Nutrients in Pine Forests in Kosong Kangwon Province (강원도 고성지역에서 산불이 소나무림 토양의 영양염류에 미치는 영향)

  • Mun, Hyeong-Tae;Choung, Yeon-Sook
    • The Korean Journal of Ecology
    • /
    • v.19 no.5
    • /
    • pp.375-383
    • /
    • 1996
  • Effects of forest fire on soil nutrients in pine forests were studied in Dosong, Kangwon Province in Korea. Soil samples were collected from burned sites and unburned sites (control) at Kusungri, Sampori and Wunbongri. Soil pH in burned sites was higher than that in unburned sites. Soil organic matter did not differ significantly between the burned and unburned sites. Concentrations of available phosphorus in burned soils were about 3 times higher than those in unburned sites. Also, concentrations of ammonium nitrogen were markedly increased in burned sites contrary to those of nitrate nitrogen. Total nitrogen, however, showed no significant difference between the sites. Concentrations of cations, calcium and magnesium, in burned sites were also significantly increased. Thus, even though forest fire removed the aboveground biomass of pine forests, inorganic nutrients added from ash may play a great role for growth of sprouts and seedlings after forest fire.

  • PDF

The study of Safety education, safe experience for students to develop research simulreyiteo (안전체험 시뮬레이터 개발에 관한 연구)

  • Kim, Tae-hwan
    • Journal of the Society of Disaster Information
    • /
    • v.6 no.1
    • /
    • pp.46-59
    • /
    • 2010
  • In this study, the safety training of comparative analysis of the realities of Korea's safety training and international experience and practical training for the safety experience of a virtual reality simulator, the development of safe conduct as a controlled motion simulator system, image H / W and the control system works, sound effects H / W and the control system works, 4D special effects (smoke, heat, wind, vibration) and a control system integration, mission control system for the selection and evaluation of the proposal, and safety training on Game S / W of development as we have never experienced an earthquake action plan and evacuate to escape the power of experience and the experience of an earthquake (vibration + video), Also the collapse and a fire escape on the experience of following second disaster, the building collapsed during an escape experience in the field, in case of fire According to the initial fire suppression and fire extinguisher usage experience - experience of smoke and heat to escape in, Moreover, the Daegu subway fire in public places such as subway and evacuated to escape the experience, considering the suggested Simulator.

Flame Extinguishing Characteristics of Clean Gaseous Agents and Effects of Additives (가스계 청정소화약제의 소화특성과 첨가제에 따른 영향)

  • Shin, Chang-Sub;Kim, Sung-Min
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.6
    • /
    • pp.95-99
    • /
    • 2008
  • Halon was known as a cause of the ozone layer destruction. In 1987, it was designated as one of the ozone-layer-destroying materials in the Montreal Protocol. Therefore substitutes of Halon agent has been developed including inert gas extinguish system, which is one of the most widely used fire extinguishing system. This study intended to increase the efficiency of inert gas extinguishing agent by using inert gas additives. As IG-541 shows high extinguishing power, the experiment was performed to measure the effects of gaseous additives to it. Cup-burner fire extinguishing apparatus was used with n-Heptane fuel. Among many of pure inert gaseous agents, Helium showed the most excellent extinguishing power. When Helium was added to IG-541, fire extinguishing power was increased and the concentration of oxygen in chimney also risen. By adding Helium to IG-541, the effectiveness of inert gas fire extinguishing system is able to be increased.

The effect of fire-safety education on the knowledge and safety competency of college students

  • Noh, Gie Ok;Park, MJ
    • International Journal of Advanced Culture Technology
    • /
    • v.10 no.1
    • /
    • pp.138-143
    • /
    • 2022
  • The purpose of this study was to test the effects of video-based fire safety education among college students on the students' fire safety knowledge and disaster safety awareness and competency. Improvements were found in fire safety knowledge (t = -3.24, p = 0.001), social disaster awareness (t = -2.25, p = 0.025), basic disaster awareness (t = -2.44, p = 0.015), and disaster safety capacity (t = -2.04, p = 0.043). The contents of safety-education materials should be continuously developed. Those materials should be provided to many people, and future research should test the longer-term effects of those educational interventions.

Experimental Study of the Blowoff Flame Phenomena Due to Changes of Balcony Length (발코니 길이변화에 의한 화염분출성상의 실험적 고찰)

  • Kim, Hoe-Cheon;Sohn, Jang-Yeul;Park, Hyung-Ju
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.3
    • /
    • pp.235-244
    • /
    • 2007
  • In the case of the fire outburst within a partitioned space, it can disappear inside it through smoldering process if the fire cannot obtain sufficient imflammability. On the contrary, if it obtains it, the fire is not restricted within the room, spreading to the higher levels beyond outside windows and the compartment room. The method to prevent the fire spread through windows is considered to build a balcony or equip with sprinkler facilities. This case study is to identify which effects and controlibility a balcony brings about on the spread of fire through a full scale model experiment. In order to understand the effects of fire spread on the upper levels of the room on fire by changing the length of balcony, the temperature was measured, radiant heat was investigated, and products of combustion were analyzed. The result showed that when fire occured, longer length of the balcony, which linked to the outside wall of the apartments, led to the blocking of the fire spread, lower level of radiant heat, and significantly less transfer of toxic gases, and the driving force of the outburst of flame was identified as the attractive force due to the turbulence of uncombusted gases, which exist on the upper level of the outbursting flame.