IoT 기반 화재탐지시스템의 연기 및 온도감지기 비화재보 신호 패턴 분석 (Analysis of Unwanted Fire Alarm Signal Pattern of Smoke / Temperature Detector in the IoT-Based Fire Detection System)

  • 박승환;김두현;김성철
    • 한국안전학회지
    • /
    • 제37권2호
    • /
    • pp.69-75
    • /
    • 2022
  • Fire-alarm systems are safety equipment that facilitate rapid evacuation and early suppression in case of fire. It is highly desirable that fire-alarm systems have low false-alarm rates and are thus reliable. Until now, researchers have attempted to improve detector performance by applying new technologies such as IoT. To this end, IoT-based fire-detection systems have been developed. However, due to scarcity of large-scale operational data, researchers have barely studied malfunctioning in fire-alarm systems or attempted to reduce false-alarm rates in these systems. In this study, we analyzed false-alarm rates of smoke/temperature detectors and unwanted fire-alarm signal patterns at K institution, where Korea's largest IoT-based fire-detection system operates. After analyzing the fire alarm occurrences at the institution for five years, we inferred that the IoT-based fire-detection system showed lower false-alarm rates compared to the automatic fire-detection equipment. We analyzed the detection pattern by dividing it into two parts: normal operation and unwanted fire alarms. When a specific signal pattern was filtered out, the false-alarm rate was reduced to 66.9% in the smoke detector and to 46.9% in the temperature detector.

계층적 Fuzzy 감지기에 대한 연구 (A Study on the multcriteria Fuzzy Fire Detector)

  • 서영수;백동현
    • 한국화재소방학회논문지
    • /
    • 제11권2호
    • /
    • pp.45-53
    • /
    • 1997
  • 본 논문은 화재 감지기의 화재판정을 결정하는 방법으로 화재의 정도를 Fuzzy화 한다음 Fuzzy I$\rho$gic을 적용하여 화재와 비화재를 판별할 수 있는 새로운 기능의 Fuzzy감지기를 제안한 것이다. F Fuzzy 감지기의 입력요소는 화재의 정확한 판단을 위하여 온도센서, 연기센서, 광센서를 이용하였으 며 센서출력 신호를 디지털화 하여 적용하였다. 그 결과 기폰의 화재 감지기보다 화재감지 능력은 우수하였으나 정확한 화재판단을 위해서는 보다 많은 Rule을 생성할 수 있는 지식이 필요 하였으며 Fuzzy 감지기를 실제 적용할 경우 그 가능성을 보 였다.

  • PDF

분진을 이용한 연기감지기 신뢰성 분석에 관한 연구 (A Study on the Reliability Analysis for Smoke Detector using Dust)

  • 홍성호;최문수;이영만
    • 한국안전학회지
    • /
    • 제28권6호
    • /
    • pp.11-16
    • /
    • 2013
  • This paper presents a study on the analyzing reliability of smoke fire detector using accelerated life test. In general, the smoke fire detector is broken by dust which flow in smoke detection chamber. In order to conduct accelerated life test of smoke fire detector dust is set accelerated factor in this paper. The dust is fly-ash which is test particle 5th regulated by KS A 0090. The dust accelerated level is 60 g, 180 g and 360 g and failure time is measured by smoke sensitivity testing. It is considered to failure of detector if detector don't operate within 30 secconds when subjected to an air stream having a velocity of 20 cm/s~40 cm/s containing smoke with a concentration of 15% of rate of light-response of 1 m. The goodness of fit test and mean life prediction conduct using the failure time. The result show that life distribution fits the weibull distribution for failure time data and the mean lifes calculate 22.5 year in domestic product and 14.7 years in overseas product applied dust stress only.

이온화식연기감지기의 사용기간 경과에 따른 성능변화 연구 (A Study on the Performance Variation Depending on Using Period of Ionization Smoke Detector)

  • 김시국;백원돈;옥경재;이춘하
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 춘계학술논문발표회 논문집
    • /
    • pp.175-179
    • /
    • 2008
  • This paper studied on the performance variation depending on using period of ionization smoke detector. In korea, there were a lot of loss of lives and property because of fire. In many cases, an alarm equipment didn't operate though it was set up, so it causes the failure of early evacuation and fire suppression. Accordingly, an experiment on the change of ionization smoke detector in capacity performed with ionization smoke detector which is set up with fire objects.

  • PDF

THE DEVELOPMENT OF A UV FLAME DETECTOR FOR THE AUTOMATIC FIRE SUPPRESSION SYSTEM FOR ENGINE COMPARTMENT FIRES

  • Lim, Sung-Mook;Jung, Ki-Chang;Kim, Eung-Sik;Kim, Hong
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.590-597
    • /
    • 1997
  • In this work, a new type of UV flame detection system was developed. In order to measure the performance of UV flame detector, various kinds of experiments was performed. The results show that the maximum response time of the UV flame detector is 0.2 seconds when the detection distance is one meter The advantages of this system include wide area, high speed response and high sensitivity. After testing the W flame detector in engine compartment it detected fire within 0.09 seconds and extinguished within 5 seconds. Hence, the UV flame detector can be applied in automatic fire suppression system for automobiles.

  • PDF

차동식 열감지기 설치기준 비교분석에 관한 연구 (Differential temperature fire detector analysis of comparative study based on sensor installation)

  • 황동환;양광모;강경식
    • 대한안전경영과학회지
    • /
    • 제16권4호
    • /
    • pp.379-389
    • /
    • 2014
  • Fire detectors are designed to minimize loss of life from a fire alarm system as an alarm to help evacuate more quickly until the completion of the evacuation alarm should be continued. the purpose of such alarms in order to achieve the characteristic fire heat release rate reaches a certain level, or when a certain time has elapsed, when the heat detector is to be alarms to answer. Requires a quick response, it is desirable to install the sensor as much as possible, but taking into account the cost of installation problems by engineering approach to minimize the quantity and rapidity of detection capability should be increased. In order to increase the rapidity of fire detectors in a room according to the height of the sensing period is to be maintained the optimum distance of the fire detector detects characteristics should be considered. Differential spot-type heat detectors installed domestic basis, depending on the type of sensor that can detect one sensor area is limited and less than 4m ceiling height regulations and simply double the number in excess of 4m and intended to be installed.

주택 실물화재실험에 의한 화재감지기 응답특성에 관한 연구 (A Study on the Response Characteristics of Fire Detector by Full-scale Experiment of Fire Phenomena in the Row House)

  • 사공성호;김시국;이춘하;정종진
    • 한국화재소방학회논문지
    • /
    • 제23권3호
    • /
    • pp.67-72
    • /
    • 2009
  • 본 논문은 주택 실물화재실험에 의한 화재감지기 응답특성에 관한 연구로서 철거가 예정된 연립주택을 화재실험대상으로 선정하여 현재 가장 많이 사용되고 있는 감지기 종류인 열감지기(차동식, 정온식, 아날로그식)와 연기감지기(광전식, 아날로그식, 단독경보형)를 주택내부에 설치여 화재감지기의 응답특성을 분석하고, 추가적으로 건물내부로의 화염전파 및 화재확대를 관찰하기 위해 열전대를 설치하여 온도변화를 측정하였다. 실험결과 주택에서 효과적인 화재감지시스템을 구축하기 위해서는 연기감지기가 열감지기보다 주택용 감지기로 적합한 것으로 나타났다.

목조문화재 건축물 구조에 따른 화재감지기 종류 선정에 관한 연구 (Selection of a Fire Detector for Wood Cultural Property)

  • 노삼규;윤형욱
    • 한국화재소방학회논문지
    • /
    • 제30권4호
    • /
    • pp.88-93
    • /
    • 2016
  • 2008년 숭례문 화재사고 이후 국내 목조문화재에 설치된 화재감지기는 목조화재의 특성이나 구조에 대한 감지기 종류 선정기준을 가지고 있지 않다. 목조문화재 건축물은 일반건축물과 구조 및 화재특성이 달라 일반규정을 적용하기 어렵다. 따라서 목조문화재 건축물에 설치되어 있는 화재감지기의 문제점을 파악하기 위하여 건축물의 형태를 4가지로 분류하였고 현장조사 및 목조건축물의 구조 및 화재특성을 살펴보았다. 문제점으로는 화재감지기 설치 장소에 따른 적응성 부족 감지기 선택과 외부화재감지 누락이 나타났다. 문제점을 해결하기 위하여 폐쇄 및 개방된 공간의 실내화재감시에는 연기감지기를 선택하고 외부화재감시를 위해서 불꽃감지기 또는 정온식 감지선형 감지기를 건물 유형에 적합한 종류를 선정하였다.

이온화식 연기감지기의 기류응답특성 연구 (A Study on Response Characteristics of ionization Smoke Detector Influenced by Air Stream)

  • 이복영;정길순;이병곤
    • 한국화재소방학회논문지
    • /
    • 제17권2호
    • /
    • pp.6-9
    • /
    • 2003
  • 공조설비에 의한 실내기류 유동특성은 정상해석에 의해 설치되는 화재감지기의 예상 응답특성과 다른 기류 유동특성을 나타내어 기류변화에 따른 이온화식 연기감지기의 응답특성지연을 규명, 성능위주의 화재감지설비 설계를 위한 기반기술 연구를 수행하였다. 실험은 일정한 연기농도를 가진 기류의 풍속을 변화시켜 이온화식 연기감지기의 기류응답특성을 규명하였다. 실험결과 이온화식 연기감지기의 응답특성은 기류속도와 반비례적인 관계가 있으며 기류속도가 60 cm/s 이상인 경우 응답특성이 예민하게 나타났다. 또한, 석유화학제품의 연소에 의한 연기에 비해 종이류의 훈소화재에 예민한 응답특성을 보이는 것으로 나타났다.

FDS 기반의 연기감지기 예측모델을 위한 입력인자 재검토 (Revision of the Input Parameters for the Prediction Models of Smoke Detectors Based on the FDS)

  • 장효연;황철홍
    • 한국화재소방학회논문지
    • /
    • 제31권2호
    • /
    • pp.44-51
    • /
    • 2017
  • 성능위주 소방설계(PBD)의 과정에서 요구피난시간(RSET) 산정의 신뢰성을 확보하기 위해서는 화재시뮬레이션을 이용한 정확한 연기감지기 작동시간 예측이 필수적이다. 본 연구의 목적은 FDS 기반의 연기감지기 수치모델에서 요구되는 입력인자의 정확도를 개선시키는 것이다. 이를 위하여 선행연구에서 적용된 화재감지기 시험장치(FDE)의 개선이 이루어졌다. 구체적으로 FDE 내부의 유동 및 연기농도 균일성이 개선되었으며, 연기입자의 전방산란 저감을 통해 감지기가 작동되는 순간의 정확한 광 소멸률이 측정되었다. 개선된 FDE를 이용한 입력인자는 기존 결과와 정량적으로 상당한 변화를 보이고 있으며, 이온화식 감지기에 비해 광전식 감지기에서 더 큰 차이가 확인되었다. 연기감지기의 작동조건은 감지기 종류, 가연물, 연기입자 및 색상에 따라 큰 차이가 발생됨을 고려할 때, PBD의 신뢰성을 향상시키기 위하여 향후 연구에서는 보다 다양한 감지기 및 가연물에 대한 입력인자 DB가 구축되어야 할 것이다.