• 제목/요약/키워드: Fire detection and warning system

검색결과 16건 처리시간 0.026초

MANGO ZDK 개발툴을 이용한 화재감지용 통신 프로토콜 개발 (A Design of Communication Protocol for Fire Detection by Using MANGO ZDK Development Tool)

  • 윤동열;주영훈;김성호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.426-429
    • /
    • 2007
  • When a fire happens in builds or apartments, peoples are tend to be caught in dangerous situations owing to the failure of searching escape route to the outside. In this work, an efficient fire detection and alarm system which makes it possible for the escapers to take adequate actions is proposed. The proposed system consists of two parts. One is fire detection modules which are located at each compartments in a building. The other is fire warning modules equipped with portable flashes having ability of visual/voice warning. Fire detection information is transmitted between each modules wirelessly. In this work, an efficient communication protocol for sensor network-based fire detection system is proposed and its feasibility is verified by practical experiments using MANGO ZDK Development tools

  • PDF

조기 경보를 위한 화재 판단 알고리즘을 이용한 무선 센서네트워크 기반 화재 감시 응용 시스템 설계 및 구현 (Development of WSN(Wireless Sensor Network)-based Fire Monitoring Application System using Fire Detection Algorithm for Early Warning)

  • 김아름;조경진;장재우;심춘보
    • 한국콘텐츠학회논문지
    • /
    • 제9권12호
    • /
    • pp.504-514
    • /
    • 2009
  • 최근 문화재나 시설물 관리를 위한 화재 감시 응용 시스템에 대한 요구가 증대되고 있다. 이러한 화재 감시 시스템은 화재 상황을 대처할 수 있도록 지원함으로써 피해규모를 축소시킬 수 있다. 그러나 기존 시스템은 일정 주기로 화재 감시를 수행함으로써 화재 판단을 지연시키는 단점이 존재한다. 또한 감시 상황을 확인 할 수 있는 사용자 인터페이스를 제공하지 않는다. 따라서 이러한 두 가지 문제점을 해결하기 위하여 첫째, 조기 위험상황 경보를 위해 새로운 화재 판단 알고리즘(Early Fire Detection Algorithm)을 제안한다. 이는 데이터 분포를 기반으로 하여 화재 판단 시작 주기를 동적으로 설정하기 때문에, 화재 판단 시간 측면에서 기존 알고리즘 보다 우수하다. 둘째, 제안하는 화재 판단 알고리즘을 통하여 사용자 인터페이스를 제공하는 화재 감시 응용 시스템을 개발한다. 마지막으로 성능 실험을 통해, 개발된 시스템이 다양한 화재 상황에서 조기 위험상황 경보를 위해 활용될 수 있음을 보인다.

Design of Emergency Fire Fighting and Inspection Robot Riding on Highway Guardrail

  • Ma, Xiaotong;Li, Xiaochen;Liu, Yanqiu;Tao, Xueheng
    • 한국멀티미디어학회논문지
    • /
    • 제25권6호
    • /
    • pp.833-843
    • /
    • 2022
  • Based on the problems of untimely Expressway fire rescue and backward traditional fire rescue methods, an emergency fire fighting and inspection robot riding on expressway guardrail is designed. The overall mechanical structure design of emergency fire fighting and inspection robot riding on expressway guardrail is completed by using three-dimensional design software. The target fire detection is realized by using the target detection algorithm of Yolov5; By selecting a variety of sensors and using the control method of multi algorithm fusion, the basic function of robot on duty early warning is realized, and it has the ability of intelligent fire extinguishing. The BMS battery charging and discharging system is used to detect the real-time power of the robot. The design of the expressway emergency fire fighting and inspection robot provides a new technical means for the development of emergency fire fighting equipment, and improves the reliability and efficiency of expressway emergency fire fighting.

Wireless Sensor Networks based Forest Fire Surveillance System

  • Son, Byung-Rak;Kim, Jung-Gyu
    • 한국정보기술응용학회:학술대회논문집
    • /
    • 한국정보기술응용학회 2005년도 6th 2005 International Conference on Computers, Communications and System
    • /
    • pp.123-126
    • /
    • 2005
  • Wireless Sensor Networks will revolutionize applications such as environmental monitoring, home automation, and logistics. We developed forest fire surveillance system. In this paper, Considering the fact that in Korea, during November to May, forest fires occur very frequently causing catastrophic damages on the valuable environment, Although exists other forest fire surveillance system such as surveillance camera tower, infrared ray sensor system and satellite system. Preexistence surveillance system can't real-time surveillance, monitoring, database and automatic alarm. But, forest fire surveillance system(FFSS) support above. In this paper, we describes a system development approach for a wireless sensor network based FFSS that is to be used to measure temperature and humidity as well as being fitted with a smoke detector. Such a device can be used as an early warning fire detection system and real-time surveillance in the area of a bush fire or endangered public infrastructure. Once the system has being development, a mesh network topology will be implemented with the chosen sensor node with the aim of developing a sophisticated mesh network.

  • PDF

CNN과 Grad-CAM 기반의 실시간 화재 감지 (Real-Time Fire Detection based on CNN and Grad-CAM)

  • 김영진;김은경
    • 한국정보통신학회논문지
    • /
    • 제22권12호
    • /
    • pp.1596-1603
    • /
    • 2018
  • 화재에 대한 신속한 예측과 경고는 인명 및 재산피해를 최소화시킬 수 있는 필수적인 요소이다. 일반적으로 화재가 발생하면 연기와 화염이 함께 발생하기 때문에 화재 감지 시스템은 연기와 화염을 모두 감지할 필요가 있다. 그러나 대부분의 화재 감지 시스템은 화염 혹은 연기만 감지하며, 화재 감지를 위한 전처리 작업을 추가함에 따라 처리 속도가 느려지는 단점이 있다. 본 연구에서는 다중 레이블 분류(Multi-labeled Classification)를 지원하는 CNN 모델을 구성해서 화염과 연기를 동시에 예측하고, CNN의 특징을 기반으로 클래스에 대한 위치를 시각화하는 Grad-CAM을 이용해서 실시간으로 화재 상태를 모니터링 할 수 있는 화재 감지 시스템을 구현하였다. 또한, 13개의 화재 동영상을 사용해서 테스트한 결과, 화염과 연기에 대해 각각 98.73%와 95.77%의 정확도를 보였다.

도로터널 방재시스템 개발 - 자연환기를 수행하는 중규모 도로터널의 정량적 위험도평가관한 연구 - (Development of safety system for Road Tunnel - The study of Quantitative risk assessment for middle scale road tunnel with natural ventilation system -)

  • 유지오;신현준;김종원
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.67-70
    • /
    • 2008
  • As a part of the project on road tunnel fire safety system development, Quantitative Risk Assessment program was developed. In this study, We carried out Quantitative Risk Assessment with this program by using a factor of cross passage interval, warning announcement time and congestion ratio etc for 1km tunnel with natural ventilation. In the case of 250m below of cross passage interval, Risk value due to warning announcement time was a slightly changed. but if cross passage interval is more than 250m, expected fatalities in the same HRR(heat release rate) was sharp increased. As a result, Quantitative Risk Assessment program which was developed in this research project is possible to risk assessment with ventilation type, cross passage for evacuation and detection system response property etc. hereafter, this program look forward to use as a tool for road tunnel performance based design.

  • PDF

조기화재 감시시스템을 위한 CO센서의 시그널컨디셔너 성능개선 (Performance Improvement of CO Sensor Signal Conditioner for Early Fire Detection System)

  • 박종찬;손진근
    • 전기학회논문지P
    • /
    • 제66권2호
    • /
    • pp.82-87
    • /
    • 2017
  • This paper presents performance improvement of CO gas sensor signal conditioner for early fire warning system. The warning system is based on the CO sensor and its advanced signal conditioning modules network that employ electochemical gas sensor. The electochemical has advantage of having a linear output and operating with a low consumption and fast response. This electrochemical gas sensor contains a gas membrane and three electrodes(working, counter, reference electrode) in contact with an electrolyte. To use a three-electrode sensor, a voltage has to be applied between the working and the reference electrode according to the specification of the sensor. In this paper, we designed these requirements that should be considered in temperature compensation algorithm and electrode measurement of CO sensor modules by using advanced signal conditioning method included 3-electrode. Simulation and experimental results show that signal conditioner of CO sensor module using 3-electrode have a advantage linearity, sensitivity and stability, fast response etc..

광역 화재감지를 위한 적외선 레이저 연기 검출 시스템의 설계 및 구현 (A Design and Development of the Smoke Detection System Using Infra-red Laser for Fire Detection in the Wide Space)

  • 박장식;송종관;윤병우
    • 한국전자통신학회논문지
    • /
    • 제8권6호
    • /
    • pp.917-922
    • /
    • 2013
  • 본 논문에서는 적외선과 가시광선 레이저를 이용하여 터널, 공항 등의 넓은 공간에서의 화재를 감지하기 위하여 연기검출 시스템을 제안한다. 제안하는 연기검출 시스템은 적외선 레이저 송수신기와 원거리에서 적외선 레이저 송수신 정합을 편리하게 하기 위한 가시광선 레이저 그리고 화재 경보를 전파하기 위한 Zigbee 무선통신 네트워크로 구성된다. 적외선 레이저 송신기와 수신기 사이에 연기가 발생하면 수신 신호의 크기가 기준값보다 작아지기는 것을 확인하고 연기를 검출한다. 적외선 레이저 송신기와 수신기 사이의 거리가 먼 경우에는 송신 측의 작은 변화에도 수신측에서는 상당히 큰 변이가 생겨 신호를 정합하는데 어려움이 있다. 본 논문에서 광역 연기검출을 위하여 적외선 레이저를 이용하고 효율적인 정합을 위하여 가시광선을 이용하는 방법을 제안한다. 그리고 연기가 감지되면 Zigbee 무선네트워크를 통하여 경보를 전달하는 연기검출 시스템을 개발하였다.

U-불국사 : 실시간 온라인 화재조기감지시스템 (U-Bulguksa: Real-Time and Online Early Fire Detection Systems)

  • 주재훈;임재걸
    • 한국전자거래학회지
    • /
    • 제12권3호
    • /
    • pp.75-93
    • /
    • 2007
  • 본 연구는 900MHz와 2.4GHz의 주파수 대역을 갖는 각각의 센서노드를 무선개인네트워크로 연결하여 불국사의 문화유산을 보호하기 위한 화재조기감지시스템을 구축한 결과에 기반을 두고 있다. 본 연구에서는 먼저 유비쿼터스 센서네트워크에 기반을 둔 문화재관리를 위한 요구사항을 분석하고, 문화재관리에서 필수적인 화재감시 및 조기탐지를 위해 적용한 U-불국사의 개발 사례를 제시한다. 이 사례는 U-불국사의 실현이라는 시간에 따라 변형 또는 훼손되는 각각의 유형문화재에 대한 정보를 실시간 온라인으로 입수하여 이를 토대로 과학적으로 문화재를 관리할 수 있는 시스템인 U-문화재관리와 이들 문화유산에 대한 정보를 현장에서 휴대 단말기로 제공해 주는 U-관광 프로젝트의 초기단계로서 수개월간의 시험운영하고 있는 것이다.

  • PDF

지상전술 C4I체계의 통합화력운용간 전투력 상승효과 평가에 관한 연구 (A Study on The Assesment of Power Improvement Effectiveness of Corps Level C4I System Applied to Integrated Fire Operation)

  • 박송기;이재영
    • 한국국방경영분석학회지
    • /
    • 제29권1호
    • /
    • pp.8-27
    • /
    • 2003
  • This paper develops a methodology that can be used to quantify the assesment of power improvement effectiveness of corps level C4I system applied to integrated fire operation by adapting Schuzer's C2 theory. This paper first describes how C4I systers can enhance the battle outcome in three way. : (1) Enhanced unit probability of survival; (2) Enhanced unit's individual effectiveness; improved exchange ratios; (3) Improved task force allocations : increased percentage of assets that can be assigned to a given engagement These enhancements are then show to result from improved probability of detection through information sharing; improved survivability and lethality through battle force coordination; and enhanced force allocation and prepositioning through improved timeliness of information(more advanced warning). It demonstrates that well-designed C4I systems can be shown to represent a significant force multiplier on the outcome of the battle.