• Title/Summary/Keyword: Fire detection and warning system

Search Result 15, Processing Time 0.02 seconds

A Design of Communication Protocol for Fire Detection by Using MANGO ZDK Development Tool (MANGO ZDK 개발툴을 이용한 화재감지용 통신 프로토콜 개발)

  • Yun, Dong-Yol;Joo, Young-Hoon;Kim, Sung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.426-429
    • /
    • 2007
  • When a fire happens in builds or apartments, peoples are tend to be caught in dangerous situations owing to the failure of searching escape route to the outside. In this work, an efficient fire detection and alarm system which makes it possible for the escapers to take adequate actions is proposed. The proposed system consists of two parts. One is fire detection modules which are located at each compartments in a building. The other is fire warning modules equipped with portable flashes having ability of visual/voice warning. Fire detection information is transmitted between each modules wirelessly. In this work, an efficient communication protocol for sensor network-based fire detection system is proposed and its feasibility is verified by practical experiments using MANGO ZDK Development tools

  • PDF

Development of WSN(Wireless Sensor Network)-based Fire Monitoring Application System using Fire Detection Algorithm for Early Warning (조기 경보를 위한 화재 판단 알고리즘을 이용한 무선 센서네트워크 기반 화재 감시 응용 시스템 설계 및 구현)

  • Kim, Ah-Reum;Jo, Kyoung-Jin;Chang, Jae-Woo;Sim, Chun-Bo
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.12
    • /
    • pp.504-514
    • /
    • 2009
  • Recently, fire monitoring application systems have been an active research area due to the safety of industries, historical monuments and so on. The fire monitoring application systems can reduce the damage of properties by providing earlier warning for possible fire situation. However, the existing systems have a drawback that they detect fire with delay due to their uniform epoch in fire detection algorithm. Moreover, they do not provide user-friendly graphical user interfaces in their fire monitoring systems. To resolve the problems, First, we propose a new fire detection algorithm (Early Fire Detection Fire Algorithm) which uses the distribution of sensing data for early fire detection. Our fire detection algorithm is better in terms of fire detection time than the existing work because it can set a start time of fire detection epoch dynamically based on data distribution. Second, we develop a fire monitoring application system which provides users with both a user-friendly graphical user interface and a fire alarm message when fire occurs. Finally, we show from our experiment that our developed system is effectively used for early fire warning in a variety of fire situations.

Design of Emergency Fire Fighting and Inspection Robot Riding on Highway Guardrail

  • Ma, Xiaotong;Li, Xiaochen;Liu, Yanqiu;Tao, Xueheng
    • Journal of Korea Multimedia Society
    • /
    • v.25 no.6
    • /
    • pp.833-843
    • /
    • 2022
  • Based on the problems of untimely Expressway fire rescue and backward traditional fire rescue methods, an emergency fire fighting and inspection robot riding on expressway guardrail is designed. The overall mechanical structure design of emergency fire fighting and inspection robot riding on expressway guardrail is completed by using three-dimensional design software. The target fire detection is realized by using the target detection algorithm of Yolov5; By selecting a variety of sensors and using the control method of multi algorithm fusion, the basic function of robot on duty early warning is realized, and it has the ability of intelligent fire extinguishing. The BMS battery charging and discharging system is used to detect the real-time power of the robot. The design of the expressway emergency fire fighting and inspection robot provides a new technical means for the development of emergency fire fighting equipment, and improves the reliability and efficiency of expressway emergency fire fighting.

Wireless Sensor Networks based Forest Fire Surveillance System

  • Son, Byung-Rak;Kim, Jung-Gyu
    • Proceedings of the Korea Society of Information Technology Applications Conference
    • /
    • 2005.11a
    • /
    • pp.123-126
    • /
    • 2005
  • Wireless Sensor Networks will revolutionize applications such as environmental monitoring, home automation, and logistics. We developed forest fire surveillance system. In this paper, Considering the fact that in Korea, during November to May, forest fires occur very frequently causing catastrophic damages on the valuable environment, Although exists other forest fire surveillance system such as surveillance camera tower, infrared ray sensor system and satellite system. Preexistence surveillance system can't real-time surveillance, monitoring, database and automatic alarm. But, forest fire surveillance system(FFSS) support above. In this paper, we describes a system development approach for a wireless sensor network based FFSS that is to be used to measure temperature and humidity as well as being fitted with a smoke detector. Such a device can be used as an early warning fire detection system and real-time surveillance in the area of a bush fire or endangered public infrastructure. Once the system has being development, a mesh network topology will be implemented with the chosen sensor node with the aim of developing a sophisticated mesh network.

  • PDF

Real-Time Fire Detection based on CNN and Grad-CAM (CNN과 Grad-CAM 기반의 실시간 화재 감지)

  • Kim, Young-Jin;Kim, Eun-Gyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.12
    • /
    • pp.1596-1603
    • /
    • 2018
  • Rapidly detecting and warning of fires is necessary for minimizing human injury and property damage. Generally, when fires occur, both the smoke and the flames are generated, so fire detection systems need to detect both the smoke and the flames. However, most fire detection systems only detect flames or smoke and have the disadvantage of slower processing speed due to additional preprocessing task. In this paper, we implemented a fire detection system which predicts the flames and the smoke at the same time by constructing a CNN model that supports multi-labeled classification. Also, the system can monitor the fire status in real time by using Grad-CAM which visualizes the position of classes based on the characteristics of CNN. Also, we tested our proposed system with 13 fire videos and got an average accuracy of 98.73% and 95.77% respectively for the flames and the smoke.

Development of safety system for Road Tunnel - The study of Quantitative risk assessment for middle scale road tunnel with natural ventilation system - (도로터널 방재시스템 개발 - 자연환기를 수행하는 중규모 도로터널의 정량적 위험도평가관한 연구 -)

  • Yoo, Ji-Oh;Shin, Hyun-Jun;Kim, Jong-Won
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.67-70
    • /
    • 2008
  • As a part of the project on road tunnel fire safety system development, Quantitative Risk Assessment program was developed. In this study, We carried out Quantitative Risk Assessment with this program by using a factor of cross passage interval, warning announcement time and congestion ratio etc for 1km tunnel with natural ventilation. In the case of 250m below of cross passage interval, Risk value due to warning announcement time was a slightly changed. but if cross passage interval is more than 250m, expected fatalities in the same HRR(heat release rate) was sharp increased. As a result, Quantitative Risk Assessment program which was developed in this research project is possible to risk assessment with ventilation type, cross passage for evacuation and detection system response property etc. hereafter, this program look forward to use as a tool for road tunnel performance based design.

  • PDF

Performance Improvement of CO Sensor Signal Conditioner for Early Fire Detection System (조기화재 감시시스템을 위한 CO센서의 시그널컨디셔너 성능개선)

  • Park, Jong-Chan;Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.2
    • /
    • pp.82-87
    • /
    • 2017
  • This paper presents performance improvement of CO gas sensor signal conditioner for early fire warning system. The warning system is based on the CO sensor and its advanced signal conditioning modules network that employ electochemical gas sensor. The electochemical has advantage of having a linear output and operating with a low consumption and fast response. This electrochemical gas sensor contains a gas membrane and three electrodes(working, counter, reference electrode) in contact with an electrolyte. To use a three-electrode sensor, a voltage has to be applied between the working and the reference electrode according to the specification of the sensor. In this paper, we designed these requirements that should be considered in temperature compensation algorithm and electrode measurement of CO sensor modules by using advanced signal conditioning method included 3-electrode. Simulation and experimental results show that signal conditioner of CO sensor module using 3-electrode have a advantage linearity, sensitivity and stability, fast response etc..

A Design and Development of the Smoke Detection System Using Infra-red Laser for Fire Detection in the Wide Space (광역 화재감지를 위한 적외선 레이저 연기 검출 시스템의 설계 및 구현)

  • Park, Jang-Sik;Song, Jong-Kwan;Yoon, Byung-Woo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.6
    • /
    • pp.917-922
    • /
    • 2013
  • In this paper, we propose a smoke detection system in order to detect a fire in a wide space, such as tunnel, airports using infra-red and visible laser. The proposed smoke detection system is composed of infra-red laser transmitter and receiver, visible laser and Zigbee wireless communication network. A visible laser is used to match transmitter and receiver and Zigbee network is utilized to propagate warnings of fire. If smoke is appeared between transmitter and receiver, received signals are decreased and it can be considered as occurring smoke. As IR laser transmitter and receiver are separated by long distance, it is difficult to match due to large variations caused by small change of direction. In this paper, it is proposed to match effectively using visible laser. When smoke is detected, warning informations are propagated by Zigbee network in the developed smoke detection system.

U-Bulguksa: Real-Time and Online Early Fire Detection Systems (U-불국사 : 실시간 온라인 화재조기감지시스템)

  • Joo, Jae-Hun;Yim, Jae-Geol
    • The Journal of Society for e-Business Studies
    • /
    • v.12 no.3
    • /
    • pp.75-93
    • /
    • 2007
  • This paper presents real-time online early fire warning systems developed for preserving cultural properties of Bulguksa which is a world heritage designated by UNESCO. The system is based on the ubiquitous sensor network employing 900MHz and 2.4GHz bands. In this paper, we analyze requirements that should be considered in building effective management systems of cultural heritages by using wireless sensor network. Finally, we introduce the architecture, sensor and network design, and software design of the fire warning systems which is an initial version of U-Bulguksa. The current version of systems has been operating in Bukguksa for a few months. U-Bukguksa project sponsored by National Information Society Agency is ultimately aimed at developing an integrated system of U-cultural heritage management and U-tourism. The former aims to conserve and manage intangible cultural properties by providing a variety of environmental information such as erosion, crack, and gradient as well as fire which are important causes of loss and damage in real-time and online. The latter refers to the intelligent tourism information and guidance systems allowing tourists to get the personalized content on cultural heritages and help guidance with mobile devices in Bulguksa.

  • PDF

A Study on The Assesment of Power Improvement Effectiveness of Corps Level C4I System Applied to Integrated Fire Operation (지상전술 C4I체계의 통합화력운용간 전투력 상승효과 평가에 관한 연구)

  • 박송기;이재영
    • Journal of the military operations research society of Korea
    • /
    • v.29 no.1
    • /
    • pp.8-27
    • /
    • 2003
  • This paper develops a methodology that can be used to quantify the assesment of power improvement effectiveness of corps level C4I system applied to integrated fire operation by adapting Schuzer's C2 theory. This paper first describes how C4I systers can enhance the battle outcome in three way. : (1) Enhanced unit probability of survival; (2) Enhanced unit's individual effectiveness; improved exchange ratios; (3) Improved task force allocations : increased percentage of assets that can be assigned to a given engagement These enhancements are then show to result from improved probability of detection through information sharing; improved survivability and lethality through battle force coordination; and enhanced force allocation and prepositioning through improved timeliness of information(more advanced warning). It demonstrates that well-designed C4I systems can be shown to represent a significant force multiplier on the outcome of the battle.