Recent Progress in Methods of Generating Water Mist for Fire Suppression

  • Guangxuan, Liao;Xin, Huang;Beihua, Cong;Jun, Qin;Jianghong, Liu;Xishi, Wang
    • 한국분무공학회지
    • /
    • 제11권4호
    • /
    • pp.251-265
    • /
    • 2006
  • To prevent the ozonosphere from being destroyed by Halon, it is an urgent task to find out Halon replacement. As one of the replacements water mist have showed broad applications by its advantages: little pollution to environment (not destroying the ozone layer or bring green house effect), extinguishing fire quickly, consuming a small quantity of water and having little damage to the protected objects. The methods of generating water mist strongly influence fire suppression effectiveness, which determine the cone angle, drop size distribution, flux uniformity, and momentum of the generating spray. The traditional water mist nozzle included pressure jet nozzles, impingement nozzles and twin-fluid nozzles. All of them have more or less disadvantages for fire suppression. Therefore, many research institutes and corporations are taking up with innovations in mist generation. This article provided some recent studies in State Key Laboratory of Fire Science (SKLFS) of University of Science and Technology of China. SKLFS have investigated new methods of generating water mist (i.e. effervescent atomization and ultrasonic atomization). and self developed a series of nozzles and developed advanced DPIVS (Digital Particle Image Velocimetry and Sizing) technique. Characteristics of water mist (the distribution of droplet sizes, flux density, spray dynamics and cone angle) produced by these nozzles were measured under different conditions (work pressure, nozzle geometry, etc.) using LDV/APV and DPTVS systems. A series of experiments were performed to study the fire suppression effectiveness in different fire scenario (different kindsof the fuel, fire size and ventilation conditions). The fire extinguishing mechanisms of water mist was also discussed.

  • PDF

소규모 헥산 풀화재를 이용한 2유체노즐의 소화 특성에 대한 실험적 연구 (Experimental Study on the Extinguishing Characteristics of Twin-fluid Nozzle using a Small-scale Hexane Pool Fire)

  • 정찬석;이치영
    • 한국화재소방학회논문지
    • /
    • 제32권3호
    • /
    • pp.35-41
    • /
    • 2018
  • 본 연구에서는 2유체노즐을 이용하여 140 ml 헥산 풀화재(Pool fire)에 대한 소화 실험을 수행하였다. 해당 풀화재의 화원(직경 80 mm인 원형) 면적은 $0.005027m^2$이고, 열방출률은 2.81 kW로 측정되었다. 물 공급 유량은 156-483 g/min (~0.156-0.483 l/min), 기체(공기와 질소) 공급 유량은 30-70 l/min이었다. 본 실험조건에서 기체 공급 유량이 많은 경우에 성공적으로 소화가 가능하였다. 소화 가능 영역에서 기체 공급 유량이 적은 경우, 물 공급 유량이 많을 때 화재 소화 소요 시간이 길었고, 물 소모량은 많은 것으로 나타났다. 반면, 기체 공급 유량이 많은 경우, 물 공급유량에 따른 화재 소화 소요 시간 및 물 소모량은 상대적으로 큰 차이가 없는 것으로 나타났다. 한편, 본 실험조건에서 공급 기체의 종류는 소화 가능 여부, 소화 소요 시간, 물 소모량에 큰 영향을 미치지 않는 것으로 측정되었다. 마지막으로 본 실험결과와 단일유체노즐을 이용한 기존 실험결과를 이용하여, 2유체노즐과 단일유체노즐의 140 ml 헥산 풀화재 소화를 위한 물 소모량을 선행적으로 비교 및 검토하였다.

고양종합터미널화재 시 소방시설의 작동실태 분석 (Analysis of the Working Conditions of Fire Protection Systems in the Goyang Bus Terminal Building Fire)

  • 이의평
    • 한국화재소방학회논문지
    • /
    • 제32권3호
    • /
    • pp.95-107
    • /
    • 2018
  • 화재조사 결과를 토대로 고양종합터미널 건물 화재 시 소방시설 작동 실태를 분석하였다. 분석결과를 요약하면 다음과 같다. 첫째, 천장 우레탄폼에 불이 붙은 직후에 옥내소화전을 이용하여 진화할 수 있음에도 시도하지 않았다. 둘째, 지하1층 대수선공사 공간은 스프링클러 알람밸브를 잠가놓아 작동하지 않았지만, 지하2층과 지상1층, 지상2층, 지상3층은 스프링클러가 작동하여 지하1층 대수선공사 공간 이외의 층으로의 화재확산을 저지하였다. 셋째, 피난유도등은 정상 작동하였지만, 터미널 2층 대합실에서 승차장 쪽으로 통하는 출구(비상구)에 피난구유도등이 설치되어 있지 않아 터미널 2층에서 다수의 사상자가 발생하게 하는데 영향을 미쳤다. 넷째, 화재수신기에서 제연설비 배기 팬 제어반에 전기신호를 보냈지만 배기 팬의 제어반에서 수동으로 취급하여 터미널 2층 제연설비 배기 팬이 작동하지 않았다.

FLAME DETECTOR의 응답특성연구

  • 이복영
    • 방재기술
    • /
    • 통권18호
    • /
    • pp.5-16
    • /
    • 1995
  • The capacity commonly required sensors includes capability of quickly and properly catching the conditions of a fire and discriminating other factors such as noise, interference, etc. IR flame detector which react to the infra-red rays emitted from the flame. This study is aimed to know the characteristic repond to the specified fire plate. Experiment is acted by manufacture's technical data that is explained relation of detective range and sensitivity.

  • PDF

화재 및 호흡조건 변화에 따른 연기입자의 인체 호흡기 내 영역별 침착량 분석 (Study on the Regional Deposition of Smoke Particles in Human Respiratory Tract under the Variation of Fire and Breathing Conditions)

  • 구재학
    • 한국화재소방학회논문지
    • /
    • 제33권6호
    • /
    • pp.95-104
    • /
    • 2019
  • 화재 시 발생하는 연기는 가스상 물질과 이들을 흡착한 미연탄소 등의 입자상 물질로 이루어져 있다. 연기 중 가스상 물질의 흡입에 의한 인체피해는 대부분 단기적으로 이루어지는 데 비하여 입자상 물질의 흡입에 의한 피해는 가스상의 흡착상태에 따라서 상대적으로 장기적으로 이루어진다. 입자상 물질이 호흡기벽에 침착하여 호흡기 및 순환기 계통에 영향을 미치는 것과 관련하여, 침착되는 연기입자의 양과 호흡기 내 침착위치는 인체피해 산정의 중요한 요소인데, 이들은 연소조건에 영향을 받는 크기 및 농도 등 입자상태와 함께 호흡조건에 영향을 받는다. 이 연구에서는 화재 시 발생하는 연기의 흡입에 의한 인체피해 연구와 관련된 호흡기 내 연기입자 침착특성 파악을 위하여 연료종류, 연소조건 및 호흡조건에 따라 호흡기 내 영역별로 침착되는 연기입자의 입경에 따른 개수 및 질량 농도를 구하였다. 또한 각 조건별로 흡입연기의 일정기간 동안 호흡기 내 질량 침착량을 대기환경 미세먼지 기준치와 비교 분석하였다.

도로터널 라이닝 화재손상 평가를 위한 가열로 개발에 관한 연구 (A Study on Development of Furnance for Road Tunnel Lining Fire Damage Evaluation)

  • 박경훈;김흥열;김형준
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 추계학술논문발표회 논문집
    • /
    • pp.479-483
    • /
    • 2008
  • There are no International Standards or Criteria pertaining to fires inside tunnels at the moment, but there are some fire-related regulations in some advanced countries such as Germany and the Netherlands where some fire-related studies have been expedited. Germany has established regulations related to the safety of structures by stipulating Fire Curves of RABT and EBA Tunnels. Also, the Netherlands has established the resistance capacity of structures by stipulating RWS curve so that they can prevent the adjacent area from being damaged due to a tunnel collapse. Hydrocarbon Fire Curve is the standard assessing the behaviour of a structure in a serious fire, by increasing the heating speed and the maximum temperature of ISO 834 Curve, while MHC Fire Curve, which was established in France, realizes more serious fire conditions. In this study, we aimed to develop the basis of full-sized experiments, with which you can assess the fire-resisting capacity against the fire strength of concrete PC panel lining, through the realization of various tunnel fire curves as mentioned above, by developing the heating furnace suitable for the requirements of Fire-Resisting Standards, with which you can assess the fire damage of tunnel concrete lining. We have developed various conditions of the heating furnace and the method to install a thermo couple within the furnace based on EFNARC and KS F2257-1. We have also conducted a calibrating experiment in order to secure its reliability.

  • PDF

성능위주 소화설비 적용을 위한 표준랙크의 화재확산속도 평가 (Evaluation on Fire Spread Speed of Standard Rack in Korea for Performance based Fire Extinguishing System)

  • 조규환;여인환
    • 한국화재소방학회논문지
    • /
    • 제30권6호
    • /
    • pp.84-91
    • /
    • 2016
  • 물품이 수직 집약적인 형태로 적재되는 랙크식 창고는 화재발생 시 화염의 급속한 상승으로 인해 그 피해가 매우 심각하다. 이에 ESFR 및 In-Rack 스프링클러, 수직 및 수평차단막 등, 다양한 소화설비 적용을 통해 화재확산 억제에 노력하고 있으나 랙크의 크기 및 적재밀도, 적재물품의 종류 등, 매우 다양한 구성조건으로 인해 적절한 소화설비 선정에 어려움이 있다. 이에 본 연구에서는 현장조사 및 설문조사 등을 통해 국내 랙크식 창고 실정을 반영한 표준랙크를 제작하였으며, 발화위치 조건에 따른 화재특성 확인을 위해 실규모화재시험을 수행하였다. 이를 통해 도출된 화재확산속도는 향후, 개발 및 적용 예정 소화설비들의 성능비교를 위한 기초자료로서 유용하게 활용될 것으로 기대한다.

화재징후 조기표출과 복합검사를 위한 표출재 설계, 제작 및 성능 평가 (Design, Fabrication, and Performance Evaluation of Showing Material for Early Expression of Fire Signs and Combined Inspection)

  • 신동철;고형호
    • 센서학회지
    • /
    • 제32권3호
    • /
    • pp.187-193
    • /
    • 2023
  • Previous research has explored early expression of fire signs before the burning of insulation. To achieve this, typically, automatic inspections are used to detect gas emitted from odor capsules at electrical connection points; additionally, early fire signs can be expressed using visual inspection of changes in the appearance of temperature caps. However, early detection of electrical fire is often difficult because only specific inspections, which are not complex, are performed. Therefore, in this paper, we present complex inspection techniques, such as visual inspection, odor inspection, and automatic inspection, and propose a showing material of fire signs that can solve conventional problems. In addition, this study examines the conditions under which the candidate material for the showing material is designed, the composition of the candidate material selected based on the designed conditions, the manufacturing means used to produce the showing material considering the temperature for early expression of fire signs, and the performance of the produced showing material. Furthermore, we analyze various effects that can occur through the proposed display material.

Modelling of the fire impact on CONSTOR RBMK-1500 cask thermal behavior in the open interim storage site

  • Robertas Poskas;Kestutis Rackaitis;Povilas Poskas;Hussam Jouhara
    • Nuclear Engineering and Technology
    • /
    • 제55권7호
    • /
    • pp.2604-2612
    • /
    • 2023
  • Spent nuclear fuel and long-lived radioactive waste must be carefully handled before disposing them off to a geological repository. After the pre-storage period in water pools, spent nuclear fuel is stored in casks, which are widely used for interim storage. Interim storage in casks is very important part in the whole cycle of nuclear energy generation. This paper presents the results of the numerical study that was performed to evaluate the thermal behavior of a metal-concrete CONSTOR RBMK-1500 cask loaded with spent nuclear fuel and placed in an open type interim storage facility which is under fire conditions (steady-state, fire, post-fire). The modelling was performed using the ANSYS Fluent code. Also, a local sensitivity analysis of thermal parameters on temperature variation was performed. The analysis demonstrated that the maximum increase in the fuel load temperatures is about 10 ℃ and 8 ℃ for 30 min 800 ℃ and 60 min 600 ℃ fires respectively. Therefore, during the fire and the post-fire periods, the fuel load temperatures did not exceed the 300 ℃ limiting temperature set for an RBMK SNF cladding for long-term storage. This ensures that fire accident does not cause overheating of fuel rods in a cask.