• Title/Summary/Keyword: Fire casualties

Search Result 201, Processing Time 0.029 seconds

RSET Analysis of Factory Workbench Layout Configuration (공장 작업대 배치 형태에 따른 RSET 분석)

  • WOO-GI JANG;DEOK-JIN JANG;HA-SUNG KONG
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.4
    • /
    • pp.479-485
    • /
    • 2023
  • Although fire incidents occur frequently in factory buildings, the focus has primarily been on property damage rather than human casualties. In this study, we conducted an analysis of RSET(Required Safe Egress Time) variation by examining the relocation of workbenchs using evacuation simulations. The results demonstrated that a simple change in workbench placement led to different RSET and variations in the feasibility of evacuation. Specifically, arranging workbenchs in a vertical configuration reduced travel time for workers and minimized total evacuation time. The hybrid layout of "vertical-horizontal" exhibited the shortest RSET, while the "horizontal-vertical" configuration resulted in the longest RSET. These research findings are significant as they provide practical alternatives to decrease RSET in small-scale factories where additional investments beyond essential safety equipment may pose challenges due to budget constraints. However, it is important to note that this study solely focused on comparing RSET while controlling for all other factors, without considering real-life fire simulations. Therefore, further research is necessary to integrate fire simulations and conduct comprehensive assessments of evacuation safety.

Life-Road : Development of an Emergency Evacuation Application using Augmented Reality and Beacon (Life-Road : 증강현실과 비콘을 사용하는 긴급대피용 애플리케이션 개발)

  • Myeon-gyun Cho
    • Journal of Digital Policy
    • /
    • v.2 no.4
    • /
    • pp.11-15
    • /
    • 2023
  • Recently, a fire suddenly broke out in a crowded theater, and many people were unable to find an escape route, becoming entangled, injured, and suffocating from smoke inhalation, resulting in a large-scale fire accident. Even though most of the people were young, they were unable to evacuate. If they had been elderly, it could have resulted in greater casualties. In particular, since it is difficult to receive accurate location information from GPS indoor, there is an urgent need for location-based services using beacons and an emergency evacuation system that intuitively shows evacuation routes in augmented reality using smart-phones. In this paper, an augmented reality-based emergency evacuation smartphone app was developed based on identifying fire locations and evacuation routes using beacons and fire sensors (IoT). In the future, if the proposed system is applied to indoor spaces where people are crowded, rapid evacuation will be possible even in a sudden fire accident, minimizing human damage.

A Study on Fire Data Analysis in Korea, Japan and USA(3) Deaths and Injuries Due to Fires (한국$\cdot$일본$\cdot$미국의 화재발생실태에 대한 비교분석(3) 화재로 인한 인명피해)

  • Lee Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.19 no.1 s.57
    • /
    • pp.1-19
    • /
    • 2005
  • The following matters were confirmed through the analysis of casualties due to fires in Korea, Japan, and the U.S. in this paper. 1 Korean statistics are not the most detailed of the three countries about casualties due to fires, so we need to have detailed statistics of them on casualties more. 2. Korean deaths are the lowest by 10-11 people due to fires per one million of population. Those of Japan are 15-17 and about 12 people in the U.S.; decreased about 2/3 only for a quarter of a century. 3. Korean deaths are on the decrease about 1.5 people per 100 cases due to fires,3.5 in Japan and 0.2-0.3 in the U.S. Likewise, Korean injuries are on the decrease per 100 cases due to fires From 14.9 in 1977 to 5.1 in 2001 and 5.3 in 2002. In the U.S., the figure was 1.0-1.6. but after the year 1994, it was 1.2 or so. It tends to some increase to 2.6-2.8 in Japan. Therefore, when fires are happened, the death probability is the highest in Japan and 15 times higher than that of the U.S. The injury probability is the highest in Korea and 5 times higher than that of the U.S. 4. Fire deaths rate is the highest in the U.S. about $80\%$ due to home fires (including apartments) among all deaths. Japan tends to decrease of $55\%$. Recently, in case of Korea. it is similar level to that of Japan. 5. Korean aged people of 65 years old and over exceeded by $7\%$ in 2000 and entered an aging society, so It Is time to Investigate and take effect policies to reduce the death of the aged . Japan has ahead a super-aged society that exceeds $20\%$ of the people over the age 65, and many of them die of fire. Consequently, Japan has taken effect policies to reduce deaths from 10 years or more than before. Therefore, it is a good proposal to analyze the policies of Japan deeply and study introduction of them.

A Study on the Causes and Improvement Plans for Firefighters' Casualty Accidents During Rescue Activities related to the Water - 4M Analysis - (수난구조활동 중 소방공무원 순직사고의 원인과 대응방안에 관한 연구 - 4M분석기법을 중심으로 -)

  • Park, Chanseok
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.4
    • /
    • pp.710-721
    • /
    • 2021
  • Purpose: The purpose of this study is to prepare an environment that can provide high-quality 119 rescue services by analyzing the causes of casualties at the water rescue and suggesting improvement plans to prevent them. Method: 5 major cases were analyzed among firefighters' casualty accidents during rescue activities related to the water over the past 10 years for case study. And the causes of the accidents were analyzed in terms of 4 values (Man, Machine, Media, Management) through the 4M analysis technique. Result: ① man: the main causes are lack of awareness of on-site safety, etc ② machine: the problem of the absence of the equipment itself, etc ③ media: the lack of information on the rescue site and the poor rescue environment conditions, ④ management : the main causes were the absence and inadequacy of the response manual for each rescue site, Conclusion: ① man: knowledge of SOP and reinforcement of education and training, etc. ② machine: there are measures such as the introduction of equipment suitable for the changing rescue site, ③media: providing sufficient information about the rescue activity environment and conducting regular road training, ④ management: policy suggestions such as establishment and dissemination of on-site safety management plans and manuals were derived.

A Study on the Improvement of Fire Alarm System in Special Buildings Using Beacons in Edge Computing Environment (에지 컴퓨팅 환경에서 비콘을 활용한 특수건물 화재 경보 시스템 개선 방안 연구)

  • Lee, Tae Gyu;Choi, Kyeong Seo;Shin, Youn Soon
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.11 no.7
    • /
    • pp.217-224
    • /
    • 2022
  • Today, with the development of technology and industry, fire accidents in special buildings are increasing as special buildings increase. However, despite the rapid development of information and communication technology, human casualties are steadily occurring due to the underdeveloped and ineffective indoor fire alarm system. In this study, we confirmed that the existing indoor fire alarm system using acoustic alarm could not deliver a sufficiently large alarm to the in-room personnel. To improve this, we designed and implemented a fire alarm system using edge computing and beacons. The proposed improved fire alarm system consists of terminal sensor nodes, edge nodes, a user application, and a server. The terminal sensor nodes collect indoor environment data and send it to the edge node, and the edge node monitors whether a fire occurs through the transmitted sensor value. In addition, the edge node continuously generate beacon signals to collect information of smart devices with user applications installed within the signal range, store them in a server database, and send application push-type fire alarms to all in-room personnel based on the collected user information. As a result of conducting a signal valid range measurement experiment in a university building with dense lecture rooms, it was confirmed that device information was normally collected within the beacon signal range of the edge node and a fire alarm was quickly sent to specific users. Through this, it was confirmed that the "blind spot problem of the alarm" was solved by flexibly collecting information of visitors that changes time to time and sending the alarm to a smart device very adjacent to the people. In addition, through the analysis of the experimental results, a plan to effectively apply the proposed fire alarm system according to the characteristics of the indoor space was proposed.

A Study on Egress Algorithm for High-rise Buildings Using Egress Simulation (피난시뮬레이션을 이용한 초고층건물의 피난 알고리즘 연구)

  • Kim, Won Kook;Seo, Dong Hyun
    • Fire Science and Engineering
    • /
    • v.32 no.1
    • /
    • pp.33-39
    • /
    • 2018
  • When the fire in the high-rise building was not extinguished in its early stage and propagated over its origin, safe egress becomes one of the most important factor to minimize the casualties. Recently fire protection for high-rise building has been reinforced after experiencing the series of disastrous fires. But, we still find many high-rise buildings do not comply with those reinforcement. And also there is a possibility of failure of reinforced fire protection system. Under these situation safe egress guide would be the final layer of protection. In this study existing egress methods were identified and evaluated. According the result of study, priority in egress should be given to the tenants on the floor of fire origin and floors exposed to the risk of fire. Then, the rest of the tenants can be evacuated simultaneously. Floors exposed in fire risk shall be determined by fire tests and/or fire simulations. But, the result of fire monitoring shall override preliminary estimations. Egress time for each algorithm was estimated by egress simulation and the result was compared. There was a little difference in egress time between total egress and phased egress, and a big difference between using stairs only and using elevators and stairs together. to a constant thickness between layers constituting a firefighter's protective clothing should be considered in the future.

A Comparative Study on Toxic Gas Index and Stop Time of Mouse Activity (연소독성지수와 마우스 행동정시시간 비교 연구)

  • Cho, Nam-Wook;Lee, Jong-Cheon;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.25 no.4
    • /
    • pp.35-41
    • /
    • 2011
  • Casualties due to toxic smoke products have been reported as major fire damage. There are various tests in order to evaluate toxic smoke from a fire at home and abroad, and KS F 2271 as a test of the gas hazard of building finish materials has been conducted in Korea. The current test of the gas hazard exposes rodent, laboratory rat, to smoke gases to evaluate combustion gas toxicity by measuring acting time of that. this study performed a test of the gas hazard for combustible polymer material, Urethane and rubber flooring, and determined gases with the FT-IR. Quantitative results compared with standard value defined in BS6853 and toxicity index (R) was calculated. Using relative comparison with animal test and the toxicity index, We tried a variety of toxicity evaluation by correlation analysis of two tests.

A study on prediction and improvement method of fire risk for a newly built college dormitory (신축 승선생활관의 화재 위험성 예측 및 개선방안에 관한 연구)

  • Kim, Byeol;Hwang, Kwang-Il
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.3
    • /
    • pp.228-234
    • /
    • 2016
  • As a college dormitory has the features of high dwelling density and a floating population that becomes crowded during particular times, when a disaster such as a fire occurs, it has the risk of causing much loss of life. In this study, the fire simulation program Fire Dynamics Simulator (FDS), is used to predict the risk when a fire occurs, to analyze the problem, and to suggest an improvement plan for a new cadet dormitory at an university in Korea. The research results are as follows. When a fire occurred in the ironing room inside the cadet dormitory, a smoke detector operated after 65 seconds. Thirteen seconds later, a sprinkler started to operate. The temperature and carbon monoxide density reached the limit value at 241 and 248 seconds, respectively. Because the limit visibility value was reached within 66 seconds after the occurrence of a fire, it is predicted that preparation must be finished and evacuation should begin within 1 minute after the fire occurs, in order to have no casualties. Synthesizing this dormitory fire risk prediction result, the visibility value is considered to be the most dangerous factor for personal safety. Because of this, installing a smoke extraction system is suggested to secure visibility. After the installation of a smoke extraction system, the problem of smoke diffusion in the corridors improved.

A Study on the Inflow Velocity Reduction Measures in Case of Fire Great Depth Underground Double-Deck Tunnel (대심도 복층터널 화재 시 유입풍속 저감방안 연구)

  • Yang, Yong-Won;Moon, Jung-Joo;Shin, Tae-Gyun
    • Fire Science and Engineering
    • /
    • v.30 no.2
    • /
    • pp.81-86
    • /
    • 2016
  • Recently, frequent traffic congestion has occurred in domestic urban roads. As a solution for downtown traffic congestion in domestic urban roads, plans for great depth underground double-deck tunnels have been made. Great depth underground double-deck tunnels that have been planned for passenger cars, has the structure of a network type; the entry of vehicles is carried out in the underground space. In these network great depth underground double-deck tunnels, the cross section and the height of the tunnel are smaller than the general road tunnel, and the smoke of a fire will propagate faster than the evacuation of tunnel passengers by the action of the traffic-ventilation and casualties are expected. Therefore, in the present study, an attempt was made to prevent the delay system for fire smoke diffusion at the time of a fire in a domestic network great depth underground double-deck tunnel according to the area of the tunnel block during the operation of the delay system for fire smoke diffusion to analyze the effects of reducing the inflow velocity. When the area of the tunnel block was not less than 50%, the effect of reducing about 21% of the wind speed acting on the tunnel was significant. If the area is more than 50%, the diffusion rate of fire smoke was reduced by approximately 21%, which will be useful for a safe evacuation.

Fire Alarm Sound Transmission in Apartment Units (공동주택에서의 화재경보음 전달)

  • Jeong, Jeong-Ho
    • Fire Science and Engineering
    • /
    • v.32 no.3
    • /
    • pp.67-75
    • /
    • 2018
  • To reduce the number of casualties in the case of fire, an alarm sound needs to be delivered to the people who remain in the apartment unit. On the other hand, it was reported that the fire alarm sound generated in the elevator hall was not delivered sufficiently to the people staying in the apartment units. In this study, the background noise level and noise level generated in an apartment unit were measured during the day and night time. In addition, the transmission of the fire alarm sound into the each room of apartment units was simulated and compared with the background noise level. The fire alarm sound generated in the elevator halls was reduced by the fire door and doors, and was not transmitted sufficiently into the internal spaces of the apartment units. Starting evacuation action was difficult after hearing the fire alarm sound generated outside the apartment units. To improve the transmission of an alarm sound to the inner spaces of apartment units, an acoustic simulation was carried out for cases where the alarm sound generator was installed on a wall-pad in the living room and the alarm sound generator was installed on the ceiling of each rooms in apartment units. Background noise of + 15 dB and 75 dB (A) were satisfied when alarm sound generator was installed on the ceiling of each room.