• Title/Summary/Keyword: Fire cases

Search Result 585, Processing Time 0.03 seconds

지진화재사례로 본 국내 도시지역의 안전대책 연구

  • 윤명오;김광일;이영재
    • Fire Science and Engineering
    • /
    • v.10 no.2
    • /
    • pp.3-12
    • /
    • 1996
  • This is a paper to figure out characteristics and damages of earthquake fire occurred in Kobe, Japan by analyzing the various damage cases. The policy implications were considered in terms of safety in metropolitan areas in Korea.

  • PDF

A Study on the model of Thermal Plume Flow in the Forest Fire (산불에 의한 열적상승유동 해석에 관한 연구)

  • Ji, Young-Moo;Park, Jung-Sang
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.358-361
    • /
    • 2008
  • A study is made of thermal plume flow model for the development of helicopter simulator over the forest fire. For numerical analysis, the Boussinesq fluid approximation and line fire model, which is assumed by the shape of forest fire spreading, are adopted. Comparing 3-D full numerical solutions with 2-D similarity solution, it has been built a new model that is capable of temperature prediction along the symmetric vertical axis in both cases of laminar and turbulent flows.

  • PDF

A Study on the Fire Safety Plan for High-Rise Building Construction (초고층 건축물 건설공사 시 화재안전계획 수립에 관한 연구)

  • Ham, Eun-Gu;Jeong, Myeong-Jin;Lee, Myeong-Gu
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2012.11a
    • /
    • pp.59-66
    • /
    • 2012
  • Recently buildings are constructed in larger and higher scales and becoming more complex. Every country in the world is competing to build high-rise buildings. Korea also has and is constructing high-rise buildings, like the 123story Jamsil Lotte Super Tower. However from small to large scale buildings and on construction sites there still are fire safety accidents that occur continuously. Therefore to improve fire safety plan, examining the actual fire safety management and understanding fire risk analysis Using Fire Modeling through Computer Simulation. Fire safety management plan related fire safety cases were collected an dan analyzed for the study. Also hazard analysis of High rise Buildings under fire compared with existing fire law sand regulations.

  • PDF

Fire Simulations (화재시뮬레이션)

  • Kim Sang-Moon;Yoon Sang-Youl;Kim Kyung-Chun
    • Journal of the Korean Society of Visualization
    • /
    • v.4 no.1
    • /
    • pp.8-13
    • /
    • 2006
  • Fire simulation has been developed for decades to analyze fire cases and provide a tool to study fundamental fire dynamics and combustion. There are three way of fire simulation which are a full scale simulation, an experimental simulation and a computational simulation. In case of a full scale simulation, because a higher cost, a higher risk, more efforts are needed, a demand for it has been decreased. But recently a demand for an experimental simulation and a computational simulation has been increased. A computational simulation has several advantages; lower cost, short period, many case studies, more visual results, a quantitative result and etc. FDS(Fire Dynamics Simulator) which has been developed in BFRL(Building and Fire Research Laboratory), NIST(National Institute of Standards and Technology) is a popular world wide code for fire simulation. Lack of accurate predictions by the model could lead to erroneous conclusions with regard to fire safety. All results should be evaluated by the informed judgment of the qualified user.

  • PDF

The Problems and Improvements of Process to Predict Fire Risk of a Building in Performance Based Design (성능위주설계에서 화재위험성 예측 과정의 문제점 및 개선방안)

  • Lee, Se-Myeoung
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.3
    • /
    • pp.145-154
    • /
    • 2014
  • Performance based design(PBD) is the method to make a fire safety design against them after predicting the factors of fire risk in a building. Therefore, predicting fire risk in a building is very important process in PBD. For predicting fire risk of a building, an engineer of PBD must consider various factors such as ignition location, ignition point, ignition source, first ignited item, second ignited item, flash over, the state of door and fire suppression system. But, it is difficult to trust fire safety capacity of the design because the process in Korea' PBD is unprofessional and unreasonable. This paper had surveyed some cases of PBD that had been made in Korea to find the problems of the process to predict fire risk. And it have proposed the improvements of process to predict fire risk of a building.

Statistical Analysis on the Structure and Performance of the Front Door in Apartment Housing (공동주택 세대 현관 방화문 구조 및 성능에 관한 통계적 분석)

  • Shim, Han-Young;Park, Won-Jun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.22 no.1
    • /
    • pp.115-123
    • /
    • 2022
  • Statistics on the occurrence of fires in residential facilities over the past 10 years, show that approximately 40% are fires in apartment buildings. To prevent the spread of fire and support evacuation in apartment housing, the fire resistance performance and performance design of fire doors are becoming more important. This study established a database using 395 quality inspection reports from 2016 to 2020, which passed the fire performance test, and derived the fire door performance-influencing factors through an analysis of the structure (12 elements) of the fire door. As a result, the effect of core material, adhesive, hinge type, blowing agent, etc. was confirmed in 287 pass cases. On the other hand, it was confirmed that the occurrence of flames and crevices in the 108 cases of failure were the major failure factors in the fire door fire resistance test. Fire doors are composed of composite materials to prevent failure of fire resistance performance, and efficient design and quality control are required through standardization of components.

Numerical study on the post-earthquake fire behavior of intermediate steel moment frames

  • Parvizizadeh, Shayan;Kazemi, Mohammad Taghi
    • Earthquakes and Structures
    • /
    • v.22 no.2
    • /
    • pp.137-145
    • /
    • 2022
  • As steel is highly sensitive to temperature variations, fire exposure is more destructive in the case of steel structures in comparison to the concrete ones. The performance of an intermediate three-story steel moment frame with 4 spans was studied under the service load, thermal load and post-earthquake fire in this paper. Also, the effects of passive fire-protection materials such as ordinary cement-based and fire-retardant coatings were investigated. To model and analyze the structure; Abaqus software is utilized. In order to apply the earthquake effect, the push-over analysis method is employed. Changes in the stories deflection, endurance time and growth of nonlinear regions due to losses in the steel stiffness and strength, are among the issues considered in this study. As an interesting finding, the beams protected by ordinary cement-based coating could sustain the fire exposure at least for 30 minutes in all cases. The mentioned time is increased by employing a new fire-retardant protection, which could prevent significant loss in the structure resistance against fire, even after 60 minutes of exposure to fire.

화학공장의 안전성 평가에 관한 고찰

  • Park, Chang-Bok
    • Fire Protection Technology
    • /
    • s.16
    • /
    • pp.28-40
    • /
    • 1994
  • This objective of safety assessment is to determine the acceptability of risks of hazards, or the coping measures, if not acceptable, by identifying and quantifying the risks potentially involved in incidents, with the information of new technology and the disasterous cases.

  • PDF

Case Analysis of the Harmful Chemical Substances' Spill (유해화학물질 유출의 사례 분석)

  • You, Jisun;Chung, Yeong-Jin
    • Fire Science and Engineering
    • /
    • v.28 no.6
    • /
    • pp.90-98
    • /
    • 2014
  • Lately accidents of harmful chemical substance in korea were repeatedly replaying. We studied problems and preparation plan in 2008 years~2014 years through analysis cases of harmful chemical substance. Leakage of chemical substance's accident situation shows that leakage in the workplace is the most 10 cases, accounting for 58.6% is the largest proportion in 2009. Leakage according to explosion accounting for 50% (5 cases) in 2004, 25% (4 cases) in 2007 and 33.3% (4 cases) in 2011 has very irregular change. Therefore, A major cause of accidents is lack of safety management. Harmful chemical substance showed various aspects, high residual substance and non-visible characteristic so response and recovery was easy. And the second damage to move a distance causes environment pollution. So a mutual-assistance system and integrated system of related organization have to build and expert of chemical incident response and therapist of chemical substance response have to establish to do efficient and rapid response.