• 제목/요약/키워드: Fire alarms

검색결과 57건 처리시간 0.029초

연소생성물이 거주자에 미치는 영향을 고려한 단독경보형감지기의 작동범위에 대한 연구 (Study on the operating range of stand-alone sensor in consideration of the impacts of combustion products on residents)

  • 이종화;김시국;지승욱;김필영;이춘하
    • 대한안전경영과학회지
    • /
    • 제14권1호
    • /
    • pp.23-31
    • /
    • 2012
  • Recent research on stand-alone focused on the improvement and development of functions for solving problems such as the limited operating time of stand-alone installed at dwelling and their low reliability caused by false alarms, but it is more urgent to study on the operating range of stand-alone sensor in consideration of the impacts of combustion products on residents because the primary goal of fire safety is minimizing casualties. This study purposed to propose the optimized operating range of stand-alone sensor in consideration of the impacts of combustion products on residents. For this purpose, we made a mathematical approach to the change of temperature over the lapse of time in compartment fires similar to house fires, and established the standards of the body's response against heat and smoke based on literature review. In addition, we surveyed domestic and foreign technological standards for stand-alone sensor, and converted them to standards for residents of the body's response against heat and smoke using mathematical model equations and analyzed them comparatively.

피난조명 및 음성경보 기능을 내장한 화재경보시스템 개발에 관한 연구 (A Study on the Development of Fire Alarm System with Evacuation Lighting and Voice Alarm Functions)

  • 이건호;최수길;김시국
    • 한국화재소방학회논문지
    • /
    • 제32권4호
    • /
    • pp.25-34
    • /
    • 2018
  • 본 논문은 피난조명 및 음성경보 기능을 내장한 화재경보시스템 개발에 관한 연구이다. 기존 화재감지기에 화재시 피난성능향상을 위해 가장 중요한 화재조기인지 및 피난시야확보가 가능하도록 피난조명 및 음성경보 기능을 자체적으로 내장한 화재감지기 및 시스템을 개발하여 성능을 확인하였다. 개발된 시스템의 경우 평균조도가 1.62 lx, 평균음향 89.7 dB, 평균음성 86.1 dB로 형식승인 및 제품검사 기술기준을 만족하는 것으로 나타났다. 추가적으로 개발된 시스템을 이용한 피난성능실험결과 본 실험조건에서 기존시스템보다 63.08%에서 67.82%까지 피난시간이 단축되는 것으로 나타났다. 개발된 시스템의 경우 자체 음성경보를 통해 화재인지 실패를 방지하고, 비상조명 점등을 통해 최소한의 피난을 위한 가시거리를 제공함으로써 화재피해를 최소화할 수 있고, 화재취약계층인 청각장애인 및 시각장애인까지 고려함으로써 당위성 및 효용성을 갖춘 화재경보시스템으로 활용될 것으로 생각된다.

에지 컴퓨팅 환경에서 비콘을 활용한 특수건물 화재 경보 시스템 개선 방안 연구 (A Study on the Improvement of Fire Alarm System in Special Buildings Using Beacons in Edge Computing Environment)

  • 이태규;최경서;신연순
    • 정보처리학회논문지:컴퓨터 및 통신 시스템
    • /
    • 제11권7호
    • /
    • pp.217-224
    • /
    • 2022
  • 오늘날 기술과 산업의 발전으로 특수건물이 늘어남에 따라 특수건물 내 화재 사고가 증가하고 있다. 그러나 정보통신기술의 빠른 발전에도 불구하고 낙후되고 실효성을 갖추지 못한 실내 화재 경보 시스템을 사용함으로 인해 인명 피해가 꾸준히 발생하고 있다. 본 연구에서는 음향경보를 이용하는 기존 실내 화재 경보 시스템이 건물 내 인원들에게 충분한 경보를 전달하지 못하는 '경보의 사각지대 문제'를 개선하고자 에지 컴퓨팅과 비콘을 활용한 화재 경보 시스템을 설계하고 구현하였다. 제안하는 개선된 화재 경보 시스템은 말단 센서 노드와 에지 노드, 사용자 애플리케이션, 서버로 구성된다. 말단 센서 노드는 실내 환경 데이터를 수집하여 에지 노드로 전송하고, 에지 노드는 전송받은 정보를 기반으로 화재 발생 여부를 모니터링 한다. 또한 에지 노드는 비콘 신호를 지속적으로 발생시켜 신호 범위 내의 사용자 애플리케이션이 설치된 스마트기기의 정보를 수집하여 서버 데이터베이스에 저장하고, 화재 발생 시 수집한 기기들의 정보를 바탕으로 모든 재실 인원에게 애플리케이션 푸시 형태로 화재 경보를 전송한다. 구현한 화재 경보 시스템의 적용 가능성을 검증하기 위해 강의실이 밀집한 대학교의 한 건물에서 신호 유효 범위 측정 실험을 진행한 결과, 에지 노드의 비콘 신호 범위 내에서 정상적으로 기기 정보를 수집하고, 수집한 정보를 바탕으로 특정 사용자들에게 신속하게 화재 경보를 전송함을 확인하였다. 이를 통해 수시로 변하는 출입자들의 정보를 유동적으로 수집하고, 이를 바탕으로 사용자와 매우 인접한 스마트기기로 경보를 전송함으로써 '경보의 사각지대 문제'를 해결하는데 적용할 수 있음을 확인하였다. 또한 실험 결과 분석을 통해 제안하는 화재 경보 시스템을 실내 공간의 특징에 따라 효과적으로 적용하는 방안을 제시하였다.

융합 소방용 안전모 개발을 위한 중요도-만족도 연관 분석 (Importance-Performance Analysis for Developing Convergence Firefighter Helmets)

  • 오미옥;신종국;강명창;신보성;문민경
    • 한국기계가공학회지
    • /
    • 제15권6호
    • /
    • pp.109-114
    • /
    • 2016
  • This study executes Importance-Performance Analysis (IPA) on existing firefighter helmet attributes and gathers ideas for improvements from fire-fighting officers to develop a convergence firefighter helmet. The results of empirical analysis were as follows: First, the weight, head fitness, ease of wearing and removal, and ease of managing the existing helmet's attributes need urgent improvement. In addition, fire-fighting officers want to add innovative functions such as oxygen deficiency alarms, poison gas sensors, temperature sensors, and network communication systems to the convergence firefighter helmet under development.

청각장애인을 위한 웨어러블 기기의 위험소리 검출 엔진 설계 (A Design of Dangerous Sound Detection Engine of Wearable Device for Hearing Impaired Persons)

  • 변성우;이석필
    • 전기학회논문지
    • /
    • 제65권7호
    • /
    • pp.1263-1269
    • /
    • 2016
  • Hearing impaired persons are exposed to the danger since they can't be aware of many dangerous situations like fire alarms, car hones and so on. Therefore they need haptic or visual informations when they meet dangerous situations. In this paper, we design a dangerous sound detection engine for hearing impaired. We consider four dangerous indoor situations such as a boiled sound of kettle, a fire alarm, a door bell and a phone ringing. For outdoor, two dangerous situations such as a car horn and a siren of emergency vehicle are considered. For a test, 6 data sets are collected from those six situations. we extract LPC, LPCC and MFCC as feature vectors from the collected data and compare the vectors for feasibility. Finally we design a matching engine using an artificial neural network and perform classification tests. We perform classification tests for 3 times considering the use outdoors and indoors. The test result shows the feasibility for the dangerous sound detection.

노부모-성인자녀 동거 가구의 주택개조 실태 및 요구 (The Actual Conditions and Needs for Housing Remodeling among the Elderly Households with Adult Children)

  • 김미희;오지영
    • 한국주거학회논문집
    • /
    • 제20권2호
    • /
    • pp.77-86
    • /
    • 2009
  • The purpose of this study was to examine the household characteristics, the actual residential environment of the elderly living with their offsprings together in Gwangju. We also evaluated their satisfaction with the needs for remodeling of their houses and the different opinions about those things between the elderly and their off springs. We used comparative and descriptive T-test in statistical analysis. The results were as follows. There were more families living in the detached houses than those living in the apartments. The average size of the houses was 100.8 square meters. The mean residence period was 13.5 years. The sons were usually the legal householders. The residents who experienced remodeling before reassigned the furniture and installed the bathtub, which was designed to be sat on comfortably in a common. A few residents installed safety system such as alarms for incident fire or gas, convenient knobs for handling and faucets for running hot or cold water separately. After the installation of alarms, convenient knobs of windows or door, Customer satisfaction for those things were quite high. But that for the installation of safety bar were the lowest in contrast. The most things the old wanted to change were to rearrange bedrooms and bathrooms on the first floor and to decorate them in westernized styles. They didn't need to set up safety bars or shower instrument for modulating heights. The second generation wanted to install the blinds or curtains more than the third generations.

조기 화재인식을 위한 화염 및 연기 검출 (Flame and Smoke Detection for Early Fire Recognition)

  • 박장식;김현태;최수영;강창순
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2007년도 추계종합학술대회
    • /
    • pp.427-430
    • /
    • 2007
  • 본 논문에서는 화재에 의한 인적물적 피해를 최소화하기 위하여 조기에 화재를 영상처리 기법을 이용하여 검출하는 방법을 제안한다. 인공조명으로 부터 화염을 판별하기 위해 화염의 고유한 색정보를 이용하여 화염후보영역을 판별하고 화염후보영역이 아닌 경우는 배경과 현재 프레임의 밝기차이와 채도를 측정하여 연기후보영역을 판별한다. 그러나 단순한 밝기 및 색체 정보만으로 화염이나 연기로 판별할 경우 오인식할 경우가 많아 화염 및 연기 후보영역에 대해 움직임을 측정한다. 각 후보영역에 대해 전형적인 움직임이 검출되면 최종적으로 화염인 경우는 활동성 정보를 이용하여 화염으로 판별하고 연기인 경우는 경계검출법을 적용하여 최종 연기 영역을 검출한다. 제안하는 방법에 대해 실제 CCTV 카메라의 영상신호에 적용한 시뮬레이션을 통해 효과적으로 화염과 연기를 동시에 검출할 수 있음을 확인하였다.

  • PDF

Improving Efficiency of University Campus Facility Management Using Digital Twin

  • Shuhei TAZAWA;Yui SATO;Stephanie BAY;Yoko NAGAYAMA;Jun INOUE
    • 국제학술발표논문집
    • /
    • The 10th International Conference on Construction Engineering and Project Management
    • /
    • pp.957-964
    • /
    • 2024
  • Universities own several campuses and many buildings within the campuses. During the operation & maintenance phase, some of the buildings have architectural components and MEPFs that must be maintained. In the authors' study, university campus Facility Manager uses paper drawings and paper documents for operations and maintenance of MEPFs, and building components, which are managed by human power. In this study, As-Built 3D model of school buildings, was developed by 3D scanning with MatterPort Pro2 camera. A digital twin of the school building was developed from integrating the As-Built 3D model with a COBie Sheet information that defines the building and facility components for FMr. This developed digital twin was used to verify the efficiency of conventional Facility Management (FM) operations. The specific procedures are as follows. (1) Conducted an interview survey on FM of conventional university campuses to organize the current operations. (2) The following building items, which are annual inspection items, were extracted from the conventional FM operations being performed, Speakers, fire alarms, fire doors, guide lights, air conditioning, and fire extinguishing equipment. (3) Since these items listed above are currently documented in different formats, the authors organized them into a database using COBie format. (4) The components of the organized COBie format and the As-Built 3Dmodel were integrated to complete the digital twin. (5) To verify the effectiveness of the digital twin, experiments were conducted on information search in current FM operations and workflows using the digital twin. (6) We also verified the effectiveness of the AS-Built 3D model by comparing between the As-Built 3D model and the BIM model. Finally, we discussed how process innovation through digitalization of FM operations contributes not only to the improvement of daily operations, but also to the productivity improvement of university management.

주택화재 예방을 위한 저소비 전력형 단독경보형 정온식감지기 개발에 관한 연구 (A Study on the Development of the Single Station Fixed Temperature Detector of Low Power Consumption for Residential Fire Prevention)

  • 박세화;조재철
    • 한국화재소방학회논문지
    • /
    • 제24권6호
    • /
    • pp.61-68
    • /
    • 2010
  • 이 논문에서는 주택화재 예방을 위해 10년 이상 전지의 교체 없이 지속적으로 유지가 되도록 회로 설계된 저소비 전력의 단독경보형 정온식감지기의 연구.개발 경험을 기술하고자 한다. 구현된 감지기는 우선하여 일본에 적용되도록 개발한 것이다. 국내에서는 주택용 화재감지기를 위한 별도의 규정이 적용되지 않고 단독경보형감지기의 규정으로 적용되고 있어서 별도의 규정을 두고 있는 일본의 사례가 인용되어 있다. 이를 위해 먼저 국내의 법적 현황, KFI 규격과 JFEII에 대한 시험 규격 비교 검토가 수행되었다. 감지기의 경보는 버저와 표시 LED를 통해 표현된다. 감지기 구현 시에 소비전류를 줄이기 위해 대기전력이 극히 적은 MCU를 적용하고, MCU의 슬립상태와 감시상태의 동작을 적절히 제어하여 평균적인 소비 전류를 최소화하도록 하였다. 정온식감지기에서 온도 검출을 위해 응답성이 빠른 서미스터를 적용하고, 감지기의 자동시험기능과 경보정지 기능도 설계에 반영하였다. 전류소비를 줄이기 위해 고려해야 할 부분에 대해서 언급이 되어 있으며, 주요한 부분에 대한 전자회로를 나타내었다. 구현 사례로서 감지기의 서미스터 동작 특성 분석 결과가 나타나 있고, 구현된 감지기의 소비 전류 측정값과 상용 전지 방전특성의 분석을 통해 10년 이상 동안 전지의 교환 없이 적용 가능함을 보여주고 있다.

분진색상에 따른 광전식연기감지기 챔버의 응답특성에 관한 연구 (A Study on Response Characteristics of Photoelectric Type Smoke Detector Chamber Due to Dust Color)

  • 이호성;김시국
    • 한국화재소방학회논문지
    • /
    • 제31권5호
    • /
    • pp.44-52
    • /
    • 2017
  • 본 논문은 분진 색상에 따른 광전식연기감지기 챔버의 응답특성에 관한 연구이다. 국내 자동화재탐지설비 및 경보설비의 화재안전기준의 개정으로 연기감지기의 실내 적용이 의무화되었으나, 아직까지 국내에서는 실내 환경에서 발생되는 실내먼지 및 환경조건 등에 의해 발생될 수 있는 부작동 및 비화재보에 대한 연구가 미비한 편이다. 이에 본 연구에서는 실내먼지 중 가장 많이 발생될 것으로 판단되는 다양한 색상의 섬유분진에 따른 연기감지기의 실내적응성을 연구하기 위해 국내에 가장 많이 보급화 되어 있는 격자형의 연기챔버를 가진 광전식 연기감지기를 실험대상으로 하고, 갈색, 백색, 회색, 흑색 4종류의 섬유분진을 실험분진으로 하여 분진시험 및 감도시험을 진행하였다. 또한, 연기챔버의 수광부 전압을 측정하여 챔버 내부의 산란현상을 관찰하였다. 실험결과 4종류의 분진 모두 오염도 A에서는 분진시험 및 감도시험에서 모두 적합한 것으로 나타났다. 반면, 오염도 B와 C에서는 갈색, 백색, 회색분진의 경우 작동시험 및 부작동시험에서 분진오염에 의한 오작동이 나타났고, 흑색분진의 경우 작동시험에서 부작동이 발생되는 것으로 확인되었다. 연기챔버의 수광부 전압측정 결과는 갈색 및 백색분진의 경우 오염도가 증가할수록 전압이 증가하였고, 회색 및 흑색분진의 경우 전압이 감소하는 것을 확인하였다.