• Title/Summary/Keyword: Fire Test

Search Result 1,899, Processing Time 0.028 seconds

The Experimental Study of Inorganic Performanent내s of Fire Resistance Evaluation (무기질계 영구거푸집의 내화성능에 관한 실험적 연구)

  • 김영진;백민수;정근호;김우재;정상진
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.10a
    • /
    • pp.495-500
    • /
    • 2002
  • The purpose of this study is to develop and to apply this permanent cement mortar form as one of those system forms to improve existing form's problems. (1) In the fire proof test with combined specimen, the fire proof covering including form section thickness is satisfied with the fire proof criterion. It is considered that form section thickness has no problem (2) The suitable method of normal pressure steam curing for the form's mass production is 4 hours in 65℃ considering production cost, the silica fume admixture is economic.

  • PDF

Study on the test laboratory for the Cause Investigation of Fire (화재원인 규명을 위한 재현실험에 관한 연구 (지하노래방 CRT 모니터의 화재 위험성관련 연구))

  • Kim, Soo-Young;Kim, Eung-Sik
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.120-123
    • /
    • 2011
  • 본 연구는 지하노래방 화재 원인 분석을 수행시 기존의 전기기기들 자체 화재위험성 연구보다 주위 먼지들의 화재 위험성을 중점적으로 연구 하였으며 이를 위하여 국내 화재가 많이 발생되는 곳의 먼지를 수거하여 먼지(dust layer)들의 전기기기 위에서의 발화, 절연저항, 전기적 아크에 의한 착화 가능성을 실험하여 예방대책의 기초자료를 제시하였다.

  • PDF

Fire Performance of Structural Lightweight Aggregate Concrete using PP fiber (PP섬유 혼입 고강도 경량골재콘크리트의 내화특성)

  • Song, Hun;Chu, Yong-Sik;Lee, Jong-Kyu
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.797-800
    • /
    • 2006
  • Normally, Structural light-weight aggregate concrete(LWC) has been main used in high rise building with the object of wight loss. In spite of LWC have the advantage of light-weight, limit the use of strength restrictions by reason that explosive spalling in fire. Especially, LWC is occurred serious fire performance deterioration by explosive spalling. Thus, this study is concerned with fire performance of LWC for the purpose of using PP fibers prevent to explosive spalling. From the experimental test result, LWC is happened explosive spalling.

  • PDF

An Experimental Study on the Responsiveness of Sprinkler Heads (스프링클러헤드 응답성에 관한 실험적 연구)

  • 김동석;박용일;박희용
    • Fire Science and Engineering
    • /
    • v.7 no.2
    • /
    • pp.3-12
    • /
    • 1993
  • The closed type sprinkler head is a component of sprinkler system for fire protection. The purpose of this study is to inverstigate the influence factors of the responsiveness of the head by heated wind tunnel experiment. As the result of this study, it was found that response time index and conduction parameter showed the same characteristic quantitative changes to head types and test methods.

  • PDF

Study on Spray Angle of a Throttleable Pintle Injector according to Total Momentum Ratio based on Hot Fire Test Conditions (연소시험 조건 기반 총운동량비에 따른 가변추력 핀틀 분사기의 분무각 분석)

  • Heo, Subeom;Kim, Dae Hwan;Lee, Suji;Yoon, Youngbin
    • Journal of ILASS-Korea
    • /
    • v.25 no.3
    • /
    • pp.126-131
    • /
    • 2020
  • Throttleable rocket engines are in high demand due to the diversification of space missions. Pintle injector is known to be suitable for throttleable rocket engines, because of its high efficiency in overall thrust zone. In this study, the relationship between spray angle of a throttleable pintle injector and total momentum ratio based on hot fire test conditions was investigated. As a result, the spray angle in 100% and 60% throttling level is higher than the spray angle obtained by the case which considers only propellant mass flow rate, owing to higher total momentum ratio (TMR). The results of this study may be useful for predicting spray angle in hot fire test.

Hot- Fire Injector Test for Determination of Combustion Stability Boundaries Using Model Chamber

  • Sohn Chae Hoon;Seol Woo-Seok;Shibanov Alexander A.;Pikalov Valery P.
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.9
    • /
    • pp.1821-1832
    • /
    • 2005
  • This study realizes the conceptual method to predict combustion instability in actual full-scale combustion chamber of rocket engines by experimental tests with model (sub-scale) chamber. The model chamber was designed based on the methodologies proposed in the previous work regarding geometrical dimensions and operating conditions, and hot-fire test procedures were followed to obtain stability boundaries. From the experimental tests, two instability regions are presented by the parameters of combustion-chamber pressure and mixture (oxidizer/fuel) ratio, which are customary for combustor designers. It is found that instability characteristics in the chamber with the adopted jet injectors can be explained by the correlation between the characteristic burning or mixing time and the characteristic acoustic time: In each instability region, dynamic behaviors of flames are investigated to verify the hydrodynamically-derived characteristic lengths of the jet injectors. Large-amplitude pressure oscillation observed in upper instability region is found to be generated by lifted-off flames.

A study on gaseous fire extinguishing system adaptability using the door fan test (Door Fan Test를 활용한 가스계 소화설비의 적응성 검증 방안 연구)

  • Lee, Chang-Wook;Yun, A-Young;Na, Jin-Seok;Um, Ki-Ju
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.99-102
    • /
    • 2010
  • 가스계 소화설비는 소화약제의 특성상 방호구역내의 누설면적에 민감하게 영향을 받고, 누설면적이 너무 크면 제대로 된 소화성능을 발휘 할 수 없기 때문에 설계 및 시공, 그리고 설치 후 성능 검증 등에 주의가 필요하다. 이전 가스계 소화설비의 성능확인방법으로 종래에는 소화약제 전량을 직접방출하거나 극히 일부 저장용기의 소화약제만을 방출시키는 소위 간이시험을 실시하는 것이 보편적이었으나, 방출시험은 고비용, 일회성 및 시험절차의 난이성, 그리고 환경오염으로 인해 실제 방출시험을 통한 설비의 신뢰성 확인이 어려운 실정이다. 이러한 상황을 감안하여 가스계 소화설비의 성능검증을 위해 Door Fan Test를 활용하는 방안에 대하여 알아보고자 한다.

  • PDF

A Numerical Analysis for Fire Spread Mechanism of Residential Building Fire (주거용 건축물의 화염전파 현상에 대한 수치해석적 검토)

  • Ahn, Chan-Sol;Kim, Heung-Youl;You, Yong-Ho;Kim, Hyung-Jun
    • Fire Science and Engineering
    • /
    • v.26 no.1
    • /
    • pp.31-37
    • /
    • 2012
  • This study is intended to present a computational thermal model for a residential building. As the Performance Based Design is more popular, fire-intensity and fire-load have turned out to be very important factors for building design and can be predicted through some computational work. To predict and estimate the fire properties of a residential fire, we made some numerical models of combustibles and residential building. In a bid to validate the estimate values, computational analysis results from numerical models were compared with real fire tests. For computational analysis, the Fire Dynamics Simulator (FDS) was used with Large Eddy Simulation (LES) model for turbulence. Consequently, fire-intensity was well predicted and flash-over of rooms were successfully estimated.

Characteristics of Protein Foam Agent by Stabilizer on the Ship Fire Extinguishment (선박화재 적용 단백포 소화약제의 안정제에 따른 소화특성)

  • Lee, Eungwoo;Shin, Changsub
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.4
    • /
    • pp.79-85
    • /
    • 2015
  • Onboard fire extinguishing system is important to protect cargo and human lives and every oil tanker has foam type fire extinguishing system. Because of environmental problem, agent which contains materials such as Perfluorinated compounds are regulated and the development of the environmental friendly agent is required. The protein foam has less environmental pollution problem and has an excellent fire extinguish performance to oil fire. In the research, bivalency metal salts were added as stabilizer to increase fire resistance and stability of the foam. Ferrous sulfate, Iron chloride and Nickel chloride were used and to adjust to vessel, sea water was applied. As a stabilizer increased, the expansion ratio was raised. However 25% drainage time was decreased over 2.0 wt.% which is knowable that the foam brokes easily. The amount of generated foam was measured to check fluidity of foam and it appeared that when $FeSO_4$ 1.2 wt.% was added, the amount of generated foam reached large and also the 25% drainage time was high. To evaluate the fire extinguishing performance for oil fire, the small scale oil fire test was executed. When $FeSO_4$ 1.2 wt.% was added, fire extinguishing time was in its shortest which informs fluidity of foam and stability are important factors on fire extinguishing efficiency.

Study on Fire Resistance of H-Section Beams Filled with Concrete at Web (웨브 보강 형태에 따른 H형강 보부재의 내화성능에 관한 연구)

  • Kwon, In-Kyu
    • Fire Science and Engineering
    • /
    • v.25 no.5
    • /
    • pp.76-84
    • /
    • 2011
  • Steel beams are one of primary member and those carries the horizontal load and floor load to axial member. To avoid structural failure when the steel beams are exposed to fire, fire resistance performance requires. Till now, the evaluation for fire resistance of the beam was conducted using the maximum load and standard fire curve defined in the KS F 2257. But recently the constructional patterns are changing toward multi-function performance to get a better structural performance and fire resistance as well. In this paper to get the databases for fire resistance, limiting temperatures of the beam, load-bearing fire tests according to load ratios, two grades of compressive concrete strengths were applied.