• Title/Summary/Keyword: Fire Station

Search Result 491, Processing Time 0.029 seconds

Explosion Risk of 2-Ethylhexanoic Acid (2-Ethylhexanoic Acid의 폭발위험성에 관한 연구)

  • Kim, Won-Kil;Kim, Jung-Hun;Choi, Jae-Wook
    • Fire Science and Engineering
    • /
    • v.29 no.6
    • /
    • pp.20-25
    • /
    • 2015
  • In order to examine the explosion risk of 2-ethylhexanoic acid, we experimentally studied the explosion limit, explosion pressure, and rate of increase of the explosion pressure at different oxygen concentrations. The lower explosion limit was 3.2% at a temperature of $100^{\circ}C$, and the oxygen concentration was 40 to 70%. The upper explosion limit was 4.5% and the lower explosion limit was 4.0% at an oxygen concentration of 21%.The maximum explosion pressure of 2-ethylhexanoic acid was 1.4161 MPa at an oxygen concentration of 70%, and the rate of increase of the explosion pressure was 62.692 MPa/s at this concentration.

Analysis of Patient Transport in Taegu Subway Fire Disaster (대구지하철화재 시의 피해자 이송의 분석)

  • 왕순주;정제명
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2003.04a
    • /
    • pp.248-254
    • /
    • 2003
  • According to the analysis of the patient transport in the fire disaster occuring at Taegu Subway Jungangro Station February 18th, 2003, authors concluded as follows. Patients were transported mainly to medical institutes which were larger and that had shorter distance. Because of non-emergenct patient's transport to larger and nearer institutes, some critical patients should be transported to more distant institutes. Dead patients before arrival were transported relatively evenly. An adequate transport according to adequate triage should be performed in the future. Early mitigation and response, correlation with the method of transport, regional guide line of disaster transport and correlation between disaster information and emergency medical information should be corrected and need research in the future.

  • PDF

A Numerical Simulation of Smoke Control in Daegu Subway Stations II. Air Flowrate of Extraction System (대구 지하철역 제연의 문제점과 대책 II. 배기방식 제연설비의 풍량)

    • Fire Science and Engineering
    • /
    • v.17 no.4
    • /
    • pp.105-110
    • /
    • 2003
  • In Part II, the temperature and smoke particle distributions of the extraction system, which yielded the best smoke removal performance among the three smoke control systems in Part I, for extraction flowrates of 0.6∼2.4 ㎥/s and two fire sizes of 200 ㎾ and 2 ㎿ were presented. The same numerical method was utilized to the same computational domain and configurations as Part I. It was shown that the extraction flowrate affects the smoke control performance significantly, and that a similar trend in improving the smoke removal performance with the increasing extraction flowrate between the two fire sizes. An extraction flowrate of 2.4 ㎥/s or higher was required for the temperature in the escape route less than $^{\circ}C$ for the given situations.

A study on present status and improvement of protection relay system in subway station for stable power supply (지하철 역사의 안정적 전원공급을 위한 보호시스템 검토)

  • Na, Jong-Woo;Jo, Won-Kang;Park, Dong-Seon;Yoo, Yeon-Seong;Moon, Hwa-Soo
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.433-444
    • /
    • 2008
  • Nowadays, subway station has provided not only transportation but living spaces for everyday activities. Therefore, a variety of facilities have been installed for a safety of citizens such as fire-fighting equipment, platform screen doors and giving high level of benefits such as air-conditioning and heating equipment, escalators, lighting apparatus. In order to operate these facilities appropriately, it is needless to say that electric power supply must be reliable. Many protection relays have been installed to protect electric apparatus and power system, nevertheless it..s study has been insufficient in the concrete. From this paper, through analyzing of protection relay system of electric room operated in line 2 of Seoul metro, we can help to improve stable power supply system of subway station.

  • PDF

Study on Subway Emergency System Based on Wireless Sensor Network (무선 센서 네트워크 기반의 지하철 응급 상황 조치 시스템에 관한 연구)

  • Choi, Ho-Jin;Park, Jong-An;Pyun, Jae-Young
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.7 no.5
    • /
    • pp.139-146
    • /
    • 2008
  • Wireless sensor network-related application system can perform functions such as environmental pollution monitoring, building control, home automation in future. In this paper, we present wireless sensor network based system for subway station in order to reduce the damage of the people and the subway station due to fire. Sensor nodes in this system can sense temperature, illumination, smoke, and human body in real time and detect the accident in the subway station. These real-time sensing and wireless networking minimize casualties and damage to property.

  • PDF

Weighted Value Sharing and Uniqueness of Entire Functions

  • Sahoo, Pulak
    • Kyungpook Mathematical Journal
    • /
    • v.51 no.2
    • /
    • pp.145-164
    • /
    • 2011
  • In the paper, we study with weighted sharing method the uniqueness of entire functions concerning nonlinear differential polynomials sharing one value and prove two uniqueness theorems, first one of which generalizes some recent results in [10] and [16]. Our second theorem will supplement a result in [17].

A Study on the Development of the Single Station Fixed Temperature Detector of Low Power Consumption for Residential Fire Prevention (주택화재 예방을 위한 저소비 전력형 단독경보형 정온식감지기 개발에 관한 연구)

  • Park, Se-Hwa;Cho, Jae-Cheol
    • Fire Science and Engineering
    • /
    • v.24 no.6
    • /
    • pp.61-68
    • /
    • 2010
  • In this paper, a research and development result for the implementation of single station fixed temperature detector for residential fire prevention is described. The detector was developed for the certification in Japanese market because of very low domestic market situation. It is in the situation that there is no other regulation especially for residential detectors in Korea, Japanese case has been reviewed. Investigation of domestic legal circumstances and a comparative study for the test standard owned by KFI (Korea Institute of Fire Industry & Technology) and JFEII (Japan Fire Equipment Inspection Institute) respectively are also indicated. The detector alarms with a buzzer and an indicating LED. In the implementation ultra low power MCU(Micro Controller Unit) is applied to control the sleeping state and the monitoring state properly with low current consumption. To sense the temperature fast response thermistor is adopted in the design of fixed temperature residential detector. Automatic test function and alarm stop function are also considered in the design. The major factors which influence to current consumption are explained for the purpose of design reference. Main electronics circuit parts related to it's characteristics of the detector are described. It is explained that the measured current and experimental result of the battery discharge can be met over 10 years operation.

A Study of smoke control mode for subway station fire (승강장 화재시 제연운전 모드에 관한 연구)

  • Rie, Dong-Ho;Kim, Ha-Young;Kim, Jung-Yup
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.178-183
    • /
    • 2008
  • 본 연구에서는 대피자의 최적 배연조건 확립을 위하여 CFD모델을 이용한 수치해석을 통해 지하철 승강장 내에서의 화재 시 다양한 배연조건에서의 화재 위험성을 검토하였다. 결과로 스크린도어를 설치한 경우가 설치하지 않은 경우보다 온도의 상승폭이 최대 $65.37%{\sim}74.97%$ 낮게 나타났다. 또한 급기나 압인 배기시 승강장에 난류가 발생함에 따라 온도 및 연기층이 교란되어 하락됨에 따라 탈출시 위험을 유발할 수 있는 것으로 판단되었다. 따라서 배연용량 및 승강장 공간 설정시 배연조건에 따른 화재 특성을 고려한 설계가 필요하다.

  • PDF

A Plan of Existing System Interface within Station (역사내 기존 시스템 인터페이스 방안)

  • Lee, Won-Jae;An, Tae-Ki;Shin, Jeong-Ryol
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.1550-1555
    • /
    • 2011
  • This paper presents the system interface standard that are associated with additional devices like sensor nodes as well as fire monitoring panel, panic button and emergency call in city railroad environment. Existing fire monitoring panel, panic button and emergency call system is responsible for fire detection and alarm, emergency alarm and communication with the manager. Recently, researches that are associated with NVR-based intelligent integrated surveillance systems and existing alarm system are activated but most of the system is dedicated to it existing. In order to expand devices that is supported other monitoring function, separate device configuration or modification of integrated surveillance system are inevitable. In this study, interface standard between standard controller, integrated command center and each device that facilitate additional expansion of integrated surveillance system and avoid the extra cost is presented.

  • PDF

A study on correlation between empowering leadership, growth needs and turnover intentions in 119 emergency medical technicians (구급대원의 임파워링 리더십과 성장욕구 및 이직의도와의 상관관계에 관한 연구)

  • Yang, Hyun-Mo;Jeon, Hyuk-Jin;Gang, Bo-Ra
    • The Korean Journal of Emergency Medical Services
    • /
    • v.17 no.3
    • /
    • pp.29-37
    • /
    • 2013
  • Purpose: The purpose of this study is to investigate how empowering leadership effects on growth needs and turnover intentions to emergency medical technicians. Methods: The study was based on seventy six paramedics and seventy EMTs-basic who were working at the fire stations. A survey questionnaire was used to prove connection between empowering leadership, growth needs, and turnover intentions. Results: There was a positive correlation between empowering leadership and growth needs, and negative correlation between empowering leadership and turnover intentions. There was a positive correlation between emergency medical technicians growth needs and turnover intentions. Conclusion: This analysis is empirically applied to study the empowering leadership focused on the empowerment act of leader to a leading role to empowerment in fire service organization.