• Title/Summary/Keyword: Fire Simulation(FDS)

Search Result 201, Processing Time 0.027 seconds

Numerical Study on the Effects of Design Parameters on the Spray Characteristics of Fire Suppression Nozzles (소화노즐의 분무특성에 대한 설계 변수 영향의 수치해석적 연구)

  • Lee, C.H.;Choi, B.I.;Han, Y.S.;Kim, C.;Chung, H.T.
    • Journal of ILASS-Korea
    • /
    • v.11 no.4
    • /
    • pp.199-204
    • /
    • 2006
  • Numerical investigation has been performed to simulate the spray characteristics in mist-spray fire suppression nozzles in sense of design parameters. Two key shape factors in nozzle orifices. i.e. diameter and length are chosen as simulation parameters. Commercial softwares, FLUENT and FDS with the proper modelings were applied as numerical tools. Main performances of nozzles, i.e., K-factors, spray angles, droplet size, jet velocities and fire suppression time are analyzed for each parameter to find optimal design conditions.

  • PDF

대공간 화재해석을 위한 난류모델의 특성 연구

  • An, Chan-Sol;Kim, Jeong-Yeop
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2013.11a
    • /
    • pp.182-183
    • /
    • 2013
  • FDS(Fire Dynamics Simulator)는 국내에서 화재해석을 위해 사용되고 있는 가장 보편적인 소프트웨어 중의 하나이다. 미국의 NIST에서 25년간 지속적인 업그레이드를 통해 개발되어 오고 있으며 인터넷 상에서 무료로 배포되고 있어 전 세계의 화재관련 연구자 및 학생들이 연구 및 학습의 목적으로 사용하고 긴 기간동안 많은 전문가들에 의해 검증되어온 소프트웨어이다. 하지만 FDS가 난류해석을 위해 사용하고 있는 Smagorinsky의 LES(Large Eddy Simulation)모델은 현재까지 발표된 LES모델 중 가장 초기의 모델로서 건축물과 같이 복잡한 형상을 갖는 계산영역에서는 결과의 신뢰성이 많이 떨어지는 것으로 알려져 있다. 본 연구에서는 FDS의 대공간의 화재해석 성능을 평가하는 것을 목적으로 스페인 Murcia에서 수행된 Murcia Atrium Fire Test를 해석 대상으로 하여 FDS가 사용하고 있는 Smagorinsky의 LES모델 및 3가지의 다른 LES모델을 사용하여 대공간 내부의 연기유동을 해석하였으며 그 결과를 비교하였다.

  • PDF

Investigation for Fire Flow of the Deeply Underground Shin-Gum-Ho Subway Station (대심도 신금호역사의 화재 유동에 대한 고찰)

  • Jang, Yong-Jun;Park, Il-Soon;Kim, Jin-Ho;Jung, Woo-Sung;Kim, Hag-Beom;Lee, Chang-Hyun
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.110-115
    • /
    • 2010
  • Recently the deeply underground tunnels have been increased along the subway railroads of urban area compared to the past subway railroads. The Shin-Gum-Ho subway station (the Fifth lines, the depth : 46m) which is the third among the deep subway stations in the Korea was chosen as the model of deeply underground stations, and attempted to do simulation of fire. This station consists of three entrance, the basement first floor (B1), the basement second floor (B2), the basement eighth floor or platform (B8) and escalators and stairs from B2 to B8. The total number of grid was about 9,000,000 to make simulation of fire and smoke from the platform to entrance in this research, and the grid system was divided into 19 blocks to increase the efficiency of this simulation. The FDS (Fire Dynamics Simulation) was chosen to make the simulation of fire, and the model of turbulent flow was LES (Large Eddy Simulation). Each block is processed in a CPU using parallel processing of MPI (Message Passing Interface). The resource of CPU for this simulation is a ten of Intel 3.0 GHz Dual CPU (20 CPU).

  • PDF

Computation of Nonpremixed Methane-Air Diffusion Flames in Microgravity (무중력에서의 비예혼합 메탄-공기 확산화염의 전산)

  • Park, Woe-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.19 no.1
    • /
    • pp.124-130
    • /
    • 2004
  • The structure of the nonpremixed methane-air counterflow flames in microgravity was investigated by axisymmetric simulation with Fire Dynamics Simulator (FDS) to evaluate the numerical method and to see the effects of strain rate and fuel concentration on the diffusion flame structure in microgravity. Results of FDS for the methane mole fractions, $X_m$=20, 50, and 80% in the fuel stream, and the global strain rates $a_g$=20, 50, and $90s^{-1}$ for each methane mole fraction were compared with those of OPPDIF, an one-dimensional flamelet code. There was good agreement in the temperature and axial velocity profiles between the axisymmetric and one-dimensional computations. It was shown that FDS is applicable to the counterflow flames in a wide range of strain rate and fuel concentration by predicting accurately the flame thickness, flame positions and stagnation points.

A Study on the Fire Reconstruction of Exterior on High-rise Building (Focus on Fire Case Including the Woosin Golden Suite in Haeundae) (고층 건축물 외장재의 화재 재현에 관한 연구 (해운대 우신골든스위트의 화재사례를 중심으로))

  • Min, Se-Hong;Lee, Jae-Moon
    • Fire Science and Engineering
    • /
    • v.27 no.2
    • /
    • pp.25-30
    • /
    • 2013
  • 'Heaundae Woosin Building' fire was the case that a fire breaking out on the $4^{th}$ floor spread out the $38^{th}$ floor which is a top story and the penthouse was destroyed by fire. After this fire, the fire safety for high rise buildings has been on the rise and several new laws and regulations related in the buildings were created. The study is to analyze Heaundae officetel building case using FDS which is one of the CFD programs for fire. The methodology of this study is to analyze the case comparing with fire spread and route from a virtual fire simulation and related articles and a video clip of actual scene fire. This study shows that a fire spreading on top of levels spent approximately 30 minutes and, which is similar to the actual fire case. Also the pattern of spread has similarity with the case. However, even if the actual fire case shows the fire pattern was "V shape", the smoke-view presents the fire dose not spread horizontally as much as the real fire case. The result shows uncertainty of the modeling based on many grids and a limitation of putting interior finish input sources and the direction of the wind might cause the difference. Also, to analyze factors influencing on a vertical fire, another fire modeling is performed by in condition of modeling environment considering concrete interior finish between buildings and no wind. The result presents the fire spread in smoke-view does not spread vertically as much as the actual case.

Numerical Analysis on Interaction between Fire Flame and Water Mist according to the Variation of Nozzle Performance (노즐 특성 변화에 따른 미분무수와 화염과의 상호작용에 관한 수치해석)

  • Bae, Kang-Youl;Chung, Hee-Taeg;Kim, Hyoung-Bum
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2983-2988
    • /
    • 2007
  • In the present study, the numerical investigation on the effects of water-mist characteristics has been carried out for the fire suppression mechanism. The FDS are used to simulate the interaction of fire plume and water mists, and program describes the fire-driven flows using LES turbulence model, the mixture fraction combustion model, the finite volume method of radiation transport for a non-scattering gray gas, and conjugate heat transfer between wall and gas flow. The numerical model is consisted of a rectangular enclosure of $L{\times}W{\times}H=1.5{\times}1.5{\times}2.0m$ and a water mist nozzle that be installed 1.8m from fire pool. In the study, the parameters of nozzle for simulation are the droplet size and the spray velocity. Finally, the droplet size influences to fire flume on fire suppression than spray velocity because of the effect of terminal velocity, and the optimal condition for fire suppression is that the droplet size and the spray velocity are $100{\mu}m$ and 20m/s, respectively.

  • PDF

Numerical Study on the Effects of Spray Properties of Water Mist on the Fire Suppression Mechanism (미분무수 특성이 화재억제 메커니즘에 미치는 영향에 대한 수치해석적 연구)

  • Bae, Kang-Youl;Chung, Hee-Taeg;Kim, Hyoung-Bum
    • Journal of ILASS-Korea
    • /
    • v.22 no.4
    • /
    • pp.175-184
    • /
    • 2017
  • The numerical investigation on the effects of water-mist characteristics has been carried out for the fire suppression mechanism. The FDS are used to simulate the interaction of fire plume and water mists, and program describes the fire-driven flows using LES turbulence model, the mixture fraction combustion model, the finite volume method of radiation transport for a non-scattering gray gas, and conjugate heat transfer between wall and gas flow. The numerical model is consisted of a rectangular enclosure of $L{\times}W{\times}H=1.5{\times}1.5{\times}2.0m^3$ and a water mist nozzle that be installed 1.8 m from fire pool. In the present study, the parameters of nozzle for simulation are the droplet size and the spray velocity. The droplet size influences to fire flume on fire suppression more than the spray velocity because of the effect of the terminal velocity. The optimal condition for fire suppression is that the droplet size and the spray velocity are $100{\mu}m$ and 20 m/s respectively.

Fire Simulation for Vent Flow and Temperature in Engine Room of Small Ship: Effects of Ceiling Duct Location and Side Vent Size (소형선박 기관실의 개구부 유동 및 온도에 대한 화재시뮬레이션: 천장 통풍통 위치 및 측면 개구부 크기 영향)

  • Jeong, Lee-Gyu;Lee, Chi Young
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.26 no.5
    • /
    • pp.454-465
    • /
    • 2020
  • Fire simulations were performed using the Fire Dynamics Simulator (FDS) software to examine the vent flow and temperature in the engine room of a small ship. A diesel fire with a heat release rate of 10 kW was targeted, and the effects of the ceiling duct location, side vent existence and nonexistence, and side vent size were investigated. The existence or nonexistence of the side vent and its size considerably affected the smoke behavior, mass flow rate through the vent, and temperature. When the side vent was not installed or was small, the smoke layer reached the floor in the engine room. In addition, as the side vent size increased, the mass flow rate through the vent increased with decreasing temperature value. However, the effects of the ceiling duct location on the smoke behavior, mass flow rate through the vent, and temperature seemed to be relatively minor compared to those of the side vent size. Therefore, to improve the fire safety of the engine room in a small ship, the side vent size is considered to be a more important design factor than the ceiling duct location.

Large Eddy Simulation of Backdraft Using the Eddy Dissipation Concept Combustion Model (Eddy Dissipation Concept 연소모델을 적용한 백드래프트 대와동모사 연구)

  • Ha, Suim;Oh, Chang Bo
    • Fire Science and Engineering
    • /
    • v.33 no.5
    • /
    • pp.48-54
    • /
    • 2019
  • A Large Eddy Simulation (LES), adopting the Eddy Dissipation Concept (EDC) 1-step model, was successfully performed for backdraft phenomena. The activation energy of the finite chemistry reaction in the EDC 1-step model was adjusted to simulate the backdraft. The prediction of the EDC 1-step model was similar to that of the Mixing-Controlled Fast Chemistry (MCFC) model, except when the backdraft occurred. The EDC 1-step model could be used to simulate the experimental peak pressure, but not the first peak pressure of the backdraft.

A study on grid aspect ratio of fire dynamics simulator (FDS의 격자 종횡비에 관한 연구)

  • Kim, Won Ouk;Park, Woe-Chul
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.9
    • /
    • pp.923-928
    • /
    • 2015
  • The FDS is one of the most used programs for fire analysis and needs an optimal grid selection for an accurate analysis. This study selected various grid aspect ratios (ARs) for selection of optimal grid and analyzed them with FDS v 6.1.2. A calculation time of 10 min. was used, which is enough to obtain the time average value of temperature changes. Temperature, visibility, and the time average value of mass balance are obtained from 200-600 s, which is a period of maintaining quasi-steady state. Two polyurethane fires of 1 [MW] and 2 [MW] in two enclosures of $10{\times}10{\times}3[m^3]$ and $20{\times}20{\times}3[m^3]$ were considered. Time variations of heat release rates, temperature, visibility, and mass balance were compared for ARs from 1-6. The heat release rates were accurate for all aspect ratios regardless of fire and enclosure sizes. The quasi-steady state temperature and visibility were well predicted for $AR{\leq}5$. Temperature drop and skewness of mass conservation, however, increased with increasing aspect ratio. Therefore, careful investigation of the grid size is recommended in performance-based design when $AR{\geq}3$, where temperature and visibility in early stage of a fire are important parameters. For accurate simulations of enclosure fires, grid sizes of 0.1~0.2 [m] and smaller in the vertical direction and $AR{\leq}2$ are recommended.