• Title/Summary/Keyword: Fire Services

Search Result 475, Processing Time 0.022 seconds

Long-Term Estimation of 119 Ambulance Services by Demographic Changes in Korea (인구 변동에 따른 119 구급 서비스의 장기 추계)

  • Kang, Kyunghee
    • Fire Science and Engineering
    • /
    • v.32 no.5
    • /
    • pp.105-111
    • /
    • 2018
  • Based on the Statistical Yearbook of 119 Emergency Medical Services in 2017 (National Fire Agency, 2018) and Population Projection by Province: 2015~2045 (Statistics Korea, 2017), this study analyzed the effects of population changes, such as low fertility and aging on the use of ambulance services in the future. The population of Korea is expected to decline after peaking in 2031, but the number of elderly people aged over 70 is expected to continue to increase. The rates of emergency ambulance transport (REAT, the number of patients transferred per 1,000 inhabitants) are not changed significantly, compared to the recent trends, but the ambulance services for elderly over 70 years of age will increase exponentially. Therefore, the population changes due to low fertility and aging is accompanied by a quantitative and qualitative change in ambulance services, and from the long term perspectives, it is necessary to consider not only the effective response of ambulance services due to aging, but also the adjustment of existing jurisdictions due to population changes and the relocation of manpower and resources.

Collateral damage of emergency medical services due to COVID-19 (COVID-19에 의한 EMS 동반손상)

  • Lee, Nam-Jin;Yang, Jin-Cheol;Moon, Jun-dong
    • The Korean Journal of Emergency Medical Services
    • /
    • v.25 no.3
    • /
    • pp.189-200
    • /
    • 2021
  • Purpose: We aimed to provide effective emergency medical services (EMS) response strategies for coping with high acuity patients during the pandemic by analyzing the influence of the COVID-19 and social distancing on EMS. Methods: In this retrospective observational study, we analyzed the distribution of high acuity patients transported by Daejeon 1-1-9 EMS during the COVID-19 pandemic period, between February 1, 2020 and October 31, 2020 and the same period in 2019, as well as the level 3 social distancing enforced period, between July 27, 2020 and October 31, 2020. Results: The EMS dispatches decreased by 17% during the observed COVID-19 pandemic period compared to the same period in 2019. The number of cases with cardiac arrest and positive prehospital stroke scale rose by (p<.001). Patients with cardiac arrest, trauma, and positive prehospital stroke scale increased by during the level 3 social distancing period. Conclusion: Unlike the decreased EMS call volume and patient transports during the COVID-19 pandemic, cardiac arrest cases and the severity of high acuity patients tended to increase. We suggest that EMS systems should contrive a response strategy considering the collateral effect of major epidemics on the incidence rate of high acuity patients.

Analysis and utilization of emergency big data (구급 빅데이터의 분석과 활용 방안에 관한 연구)

  • Lee, Seong-Yeon;Kwon, Yu-Jin;Lim, Dong-Oh;Kim, Min-Gyu;Park, Hee-Jin;Kwon, Hay-Rhan;Ju, Young-Cheol
    • The Korean Journal of Emergency Medical Services
    • /
    • v.20 no.1
    • /
    • pp.41-55
    • /
    • 2016
  • Emergency statistics for cities and provinces are currently derived using simple results of comparative numerical data, but there is a limit to the ability to analyze and compare deviations relevant to a specific city and province. This study aims to derive various correlations through statistical analysis of emergency and rescue data for Gwangju Metropolitan City and to develop an analytical model that can be applied nationwide. With the new statistical model, further detailed analysis is possible beyond simple evaluation of rescue data, through links to other institutions and analyses using keywords from Internet portal sites and social networks. Second, a system which that can analyze data that are not shared is required. Through this system, a large amount of data can be automatically analysed in real time. Third, the results should flow back for application in various policies. A real-time monitoring and management system should be created for abnormal patterns of disease. In addition, the results should be available to tailor services for individuals, communities, or specific organizations.

Effects of job satisfaction and spouse support on parenting stress in female fire fighters with preschool-aged children (취학 전 자녀를 둔 여성소방공무원의 직무만족도와 배우자 지지가 양육스트레스에 미치는 영향)

  • Che, Ga-Young;Baek, Mi-Lye
    • The Korean Journal of Emergency Medical Services
    • /
    • v.19 no.1
    • /
    • pp.87-98
    • /
    • 2015
  • Purpose: Job satisfaction, spouse support, parenting stress, and the factors that influence parenting stress in female fire fighters with preschool-aged children were examined. Methods: Data were collected from 180 female fire fighters who worked at the fire station from June to July 2013 and had preschool-aged children. Data were analyzed using SPSS WIN 21.0. Results: Average job satisfaction was 2.81, spouse support was 3.54, and parenting stress was 3.61. Parenting stress was negatively correlated with spouse support and job satisfaction. Job satisfaction and spouse support were positively correlated. Factors influencing parenting stress included employment period (${\beta}$=0.093, p <.05), a husband who is not a fire fighter (${\beta}$=-8.971, p <.05), having three children (${\beta}$=27.395, p <.05), delegating childcare to relatives (${\beta}$=9.605, p <.05), income (${\beta}$=-0.920, p <.05), and spouse support (${\beta}$=-0.589, p <.05). Conclusion: To reduce parenting stress and increase job satisfaction, female fire fighters with preschool-aged children should be assigned to stable administrative work instead of stressful on-site work. Husbands who are fire fighters should take advantage of paternity leave, implemented by the Ministry of Public Safety and Security, to increase their active participation in parenting.

A study on correlation between empowering leadership, growth needs and turnover intentions in 119 emergency medical technicians (구급대원의 임파워링 리더십과 성장욕구 및 이직의도와의 상관관계에 관한 연구)

  • Yang, Hyun-Mo;Jeon, Hyuk-Jin;Gang, Bo-Ra
    • The Korean Journal of Emergency Medical Services
    • /
    • v.17 no.3
    • /
    • pp.29-37
    • /
    • 2013
  • Purpose: The purpose of this study is to investigate how empowering leadership effects on growth needs and turnover intentions to emergency medical technicians. Methods: The study was based on seventy six paramedics and seventy EMTs-basic who were working at the fire stations. A survey questionnaire was used to prove connection between empowering leadership, growth needs, and turnover intentions. Results: There was a positive correlation between empowering leadership and growth needs, and negative correlation between empowering leadership and turnover intentions. There was a positive correlation between emergency medical technicians growth needs and turnover intentions. Conclusion: This analysis is empirically applied to study the empowering leadership focused on the empowerment act of leader to a leading role to empowerment in fire service organization.

A Study on Factory Building Fire Risk Reduction Management (공장건물의 화재리스크 경감방안에 관한 연구)

  • Chung, Eui-Soo;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.10 no.3
    • /
    • pp.43-53
    • /
    • 2008
  • This study is carried out for the fire safety of the factory building, the fire risk reduction measure in compliance with an example approached in fire risk reduction systematically, contribute to reduce the fire risk. The analytical fire risk process of discovering, identifying, estimating and evaluating risk and control measure as risk reduction measures are core concept, applies loss prevention with loss control techniques. The painting process in the workplace where the fire hazard and death accident accompanies coexists. Loss prevention problem of creation prevention of dangerous atmosphere at workplace is health and human services problem of normal circumstances, must be inspected with problem of combustible gases at the time of fire explosion. Static electricity measure accomplished the risk control process thoroughly as the fire risk reduction process model with the ignition sources measure which is presented. Fire risk from within organizing will be able to classify with each field by detailedly but risk treatment process will be able to apply basically all the same concept. Consequently about risk management example from before, this study is proposed risk management techniques that standardized rightly in the actual condition of organization with one plan, with discovery of fire risk, the feedback process in compliance with a fire risk reduction and the review which control the result is joint responsibility of engineer, technical expert and manager as part of safety management to practice with the fact must be supervised.

Cooling and Heating Performance Evaluation of a GSHP System (지열원 열펌프 시스템의 냉${\cdot}$난방 성능 평가)

  • Sohn Byong Hu;Cho Chung-Sik;Shin Hyun-Jun;An Hyung-Jun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.1
    • /
    • pp.71-81
    • /
    • 2005
  • The main objective of the present study is to investigate the performance characteristics of a ground-source heat pump(GSHP) system with a 130 m vertical and 62 mm nominal diameter U-tube ground heat exchanger. In order to evaluate the performance analysis, the ground-source heat pump connected to a test room with $90\;m^2$ floor area in the Korea Institute of Construction $Technology(37^{\circ}39'N,\;126^{\circ}48'E)$ was designed and constructed. This ground-source heat pump system mainly consisted of ground heat exchanger, indoor heat pumps and measuring devices. The cooling and heating loads of the test room were 5.5 and 7.2 kW at design conditions, respectively. The experimental results were obtained from July 2, 2003 to July 1, 2004. The cooling and heating performance coefficients of the system were determined from the measured data. The average cooling and heating COPs for the system were obtained to be 4.90 and 3.96, respectively. The temperature variations in ground and the ground heat exchanger pipe surface at different depths were also measured.

Evaluation of Effective Thermal Conductivity and Thermal Resistance in Ground Heat Exchanger Boreholes (지중 열교환기 보어홀에서의 유효 열전도도 및 열저항 산정)

  • Sohn Byong Hu;Shin Hyun-Joon;Park Seong-Koo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.8
    • /
    • pp.695-703
    • /
    • 2005
  • The objective of this study is to determine the effective thermal conductivity and thermal resistance values in test boreholes with three different fill materials. To evaluate these heat transfer properties, in-situ tests on four vertical boreholes were conducted by adding a monitored amount of heat to water over various test lengths. Two parameter estimation models, line-source and numerical one-dimensional models, for evaluation of thermal response test data were compared when applied on the same four data sets. Results show that the average thermal conductivity deviation between measured data and these two models is in the range of $3.03\%$ to $4.45\%$. The effect of increasing grout thermal conductivity from 1.34 to 1.82 $W/m^{\circ}C$ resulted in overall increases in effective formation thermal conductivity by $11.1\%$ to $51.9\%$ and reductions in borehole thermal resistance by $11.6\%$ to $26.1\%$.

A Construction of the N-BMS Focused on the Building Service Equipment (N-BMS : National Building Management System) (건물 군관리시스템 구축방안)

  • Lee, Tae-Won;Kim, Yong-Ki;Kang, Sung-Ju
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.149-154
    • /
    • 2007
  • Now, in Korea, the performances of the building service equipment relay on the individual superintendent's share for the assessment of performance, fault detection, deterioration diagnosis of the building service equipment. As the result, very different quality of the performance or the durability of equipment is being obtained with his skill and effort and it is also not easy to assess that quality. This finally lead to the waste of labor force and the operating cost due to the high-cost, low-efficiency system. How to construct the N-BMS was considered to save energy, resource and to conserve performance of building service equipment. The FEMIS, facility, energy/environmental management & information system, for building service offer management process integrated with BAS, FMS and EMS and so on.

  • PDF

A Comparison of Heating Control Characteristics by Temperature Sensing Methods for Thermostatic Valves with the Proportional Control Mode (비례제어식 자동온도조절기의 온도감지방식별 난방제어 특성 비교)

  • Kim, Yong-Ki;Lee, Tae-Won;Kang, Sung-Ju
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.161-166
    • /
    • 2007
  • Various thermostatic valves have been used widely in Korea for conservation of heating energy and enhancement of thermal comfort in residential buildings. But heating control performances of thermostatic valves extensively vary with the design and operational conditions of the heating system, climate condition and others. An experimental method was carried out in this study to analyze heating control characteristics by temperature sensing methods of thermostatic valves for various parameters, such as supply temperatures and flow rate of hot water, the position of room thermostats and outdoor air temperatures. As a result, the heat flow rate per day of S-Valve($34^{\circ}C$-Type) of water temperature sensing method was liked that of C-Valve of indoor air temperature sensing method with stage 3.3 of room thermostat in case supply temperature of hot water was $45^{\circ}C$, flow rate was 1.3 L/min and outdoor air temperature was $7.8^{\circ}C$.

  • PDF