Significance Analysis of Facility Fires Though Spatial Econometrics Assessment (공간계량분석 방법에 따른 시설물 화재 발생 유의성 분석)

  • Seo, Min Song;Yoo, Hwan Hee
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.38 no.3
    • /
    • pp.281-293
    • /
    • 2020
  • Recently, large and small fires have been happening more often in Korea. Fire is one of the most frequent disasters along with traffic accidents in korean cities, and this frequency is closely related to the land use and the type of facilities. Therefore, in this study, the significance of fires was analyzed by considering land use, facility types, human and social factors and using 10 years of fire data in Jinju city. Based on this, OLS (Ordinary Least Square) regression analysis, SLM (Spatial Lag Model) and SEM (Spatial Error Model) using space weights, were compared and analyzed considering the location of the fire and each factor, then a statistical model with high suitability was presented. As a result, LISA analysis of spatial distribution patterns of fires in Jinju city was conducted, and it was proved that the frequency of fires was high in the order as follow, central commercial area, industrial area and residential area. Multiple regression analysis was performed by integrating demographic, social, and physical variables. Therefore, the three models were compared and analyzed by applying spatial weighting to the derived factors. As a result of the significance test, the spatial error model was analyzed to be the most significant. The facilities that have the highest correlation with fire occurrence were second type neighborhood facilities, followed by detached house, first type neighborhood facilities, number of households, and sales facilities. The results of this study are expected to be used as significant data to identify factors and manage fire safety in urban areas. Also, through the analysis of the standard deviation ellipsoid, the distribution characteristics of each facility in the residential area, industrial area, and central commercial area among the use areas were analyzed. In, the second type neighborhood facility with the highest fire risk was concentrated in the center. The results of these studies are expected to be used as useful data for identifying factors and managing fire safety in urban areas.

A Study on Replay Experiments and Thermal Analysis for Autoignition Phenomenon of Shredded Waste Tires (폐타이어 분쇄물의 자연발화현상에 대한 재연실험 및 열분석에 관한 연구)

  • Koh, Jae Sun;Jang, Man Joon
    • Fire Science and Engineering
    • /
    • v.26 no.6
    • /
    • pp.99-108
    • /
    • 2012
  • These days, spontaneous ignition phenomena by oxidizing heat frequently occur in the circumstances of processing and storing waste tires. Therefore, to examine the phenomena, in this work, this researcher conducted the tests of fires of fragmented waste tires (shredded tire), closely investigated components of the fire residual materials collected in the processing and storing place, and analyzed the temperature of the starting of the ignition, weight loss, and heat of reaction. For the study, this researcher conducted fire tests with fragmented waste tires in the range of 2.5 mm to 15 mm, whose heat could be easily accumulated, and performed heat analysis through DSC and TGA, DTA, DTG, and GC/MS to give scientific probability to the possibility of spontaneous ignition. According to the tests, at the 48-hour storage, rapid increase in temperature ($178^{\circ}C$), Graphite phenomenon, smoking were observed. And the result from the DTA and DTG analysis showed that at $166.15^{\circ}C$, the minimum weight loss occurred. And, the result from the test on the waste tire analysis material 1 (Unburnt) through DSC and TGA analysis revealed that at $180^{\circ}C$ or so, thermal decomposition started. As a result, the starting temperature of ignition was considered to be $160^{\circ}C$ to $180^{\circ}C$. And, at $305^{\circ}C$, 10 % of the initial weight of the material reduced, and at $416.12^{\circ}C$, 50 % of the intial weight of the material decreased. The result from the test on oxidation and self-reaction through GC/MS and DSC analysis presented that oxidized components like 1,3 cyclopentnadiene were detected a lot. But according to the result from the heat analysis test on standard materials and fragmented waste tires, their heat value was lower than the basis value so that self-reaction was not found. Therefore, to prevent spontaneous ignition by oxidizing heat of waste tires, it is necessary to convert the conventional process into Cryogenic Process that has no or few heat accumulation at the time of fragmentation. And the current storing method in which broken and fragmented materials are stored into large burlap bags (500 kg) should be changed to the method in which they are stored into small burlap bags in order to prevent heat accumulation.

Basic System Architecture Design for Airport GIS Service Models (Airport GIS 구축을 위한 서비스모델 설계에 관한 연구)

  • Sim, Jae-Yong;Lee, Tong-Hoon;Park, Joo-Young
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.7 no.3
    • /
    • pp.82-94
    • /
    • 2008
  • Airport GIS is a comprehensive information system to improve security and efficiency of airport. At the initial stage to make it real, the current status of domestic and international regulations along with relevant standardization bas been reviewed. Gimpo Airport becomes a test-bed to get some ideas about how to bring the airport GIS into workflow by building service model and basic design based on current status and demand analysis of the airport. The 6 service models primarily brought into the project are as follows: (1) Local vehicles safety management in airside, (2) Intelligent traffic control between flights and vehicles at main cross points, (3) Dynamic safety management against FOD in airside and breakage on pavement, (4) Special support vehicle management such as deicing remotely controlled, (5) Response and support for fire vehicles and ambulances of signatory institutions in emergency. The upcoming research topic aims at drawing a specific design and building integrated system in the future.

  • PDF

A Study on Durability Test of Check Valve for CNG Vehicles (천연가스 차량용 체크밸브의 내구성능에 관한 연구)

  • Kim, Chang-Gi;Lee, Sun-Youp;Cho, Gyu-Baek
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.6
    • /
    • pp.15-20
    • /
    • 2009
  • The number of compressed natural gas (CNG) vehicles have increased gradually by virtue of korea government's urban air quality improvement policy since 1998. Although the use of CNG as transportation fuel gives environmental benefits, there is a possibility of huge accidents from unexpected fire. Therefore, needs for the guarantee of safety are indispensible for the reliable operation of CNG vehicles. A check valve is a safety device which prevents leakage of the pressurized fuel charged in a fuel tank. Durability of this component should be guaranteed in spite of repeated operation. This research has performed durability tests of a CNG check valve regarding the repeated usage, extreme chattering, and the effect of compressor oil.Although a check valve used for CNG vehicle satisfies validation requirements in the test results, it has been found that problem in the function of leakage prevention in a check valve could take place in the case of prolonged exposure to compressor oil.

  • PDF

A Computational Study on Cooling Analysis of the Flame Deflector for the 75 tonf Class Propulsion Test Facility (75톤급 추진기관 시험설비 화염유도로 냉각해석에 관한 수치적 연구)

  • Moon, Seong-Mok;Cho, Nam-Kyung;Kim, Seong-Lyong;Jun, Sung-Bok;Lee, Kyoung-Hoon;Kim, Dong-Hwan
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.19 no.2
    • /
    • pp.55-64
    • /
    • 2015
  • In this study, a 3-D flame cooling analysis is conducted to examine thermal safety for the flame deflector of the 75 tonf class propulsion test facility, and the safe discharge of the exhaust gas is assessed by using numerical results. The Mixture multiphase model is adopted for the simulation of heat transfer and phase exchange process between flame and cooling water, and the computational study using the single species unreacted model for the exhaust plume is carried out for the flame cooling. Numerical analysis predicts maximum temperature on the flame deflector wall for different water flow rates, and evaluates the safe minimum flow rate of water corresponding to the fire-resistant temperature for concrete.

Smoke Generation by Burning Test of Cypress Plates Treated with Boron Compounds (붕소 화합물로 처리된 편백목재의 연소시험에 의한 연기발생)

  • Chung, Yeong-Jin;Jin, Eui
    • Applied Chemistry for Engineering
    • /
    • v.29 no.6
    • /
    • pp.670-676
    • /
    • 2018
  • Experiments on combustion gases generation of untreated cypress specimens or treated with boric acid, ammonium pentaborate, and boric acid/ammonium pentaborate additive were carried out. Test specimens were painted three times with 15 wt% boron compound aqueous solutions. After drying, the generation of combustion gas was analyzed using a cone calorimeter (ISO 5660-1). As a result, comparing to untreated specimen, the smoke performance index (SPI) of the specimens treated with the boron compound increased by 1.37 to 2.68 times and the smoke growth index (SGI) decreased by 29.4 to 52.9%. The smoke intensity (SI) of the specimens treated with boron compounds is expected to be 1.16 to 3.92 times lower than that of untreated specimens, resulting in lower smoke and fire hazards. Also, the maximum carbon monoxide ($CO_{peak}$) concentration of specimens treated with boron compounds was 12.7 to 30.9% lower than that of untreated specimens. However, it was measured to produce fatal toxicities from 1.52 to 1.92 times higher than that of permissible exposure limits (PEL) by Occupational Safety and Health Administration (OSHA). The boron compounds played a role in reducing carbon monoxide, but it did not meet the expectation of reduction effect because of the high concentration of carbon monoxide in cypress itself.

Explosion Characteristics and Flame Velocity of Suspended Plastic Powders (플라스틱 부유 분진의 폭발특성과 화염전파속도)

  • Han, Ou Sup;Lee, Keun Won
    • Korean Chemical Engineering Research
    • /
    • v.54 no.3
    • /
    • pp.367-373
    • /
    • 2016
  • Many of plastic powders handled in industry are combustible and have the hazard of dust fire and explosion accidents. However poor information about the safe handling has been presented in the production works. The aim of this research is investigated experimentally on explosive characteristics of various plastic powders used in industry and to provide additional data with safety informations. The explosibility parameters investigated using standard dust explosibility test equipment of Siwek 20-L explosion chamber. As the results, the dust explosion index ($K_{st}$) of ABS ($209.8{\mu}m$), PE ($81.8{\mu}m$), PBT ($21.3{\mu}m$), MBS ($26.7{\mu}m$) and PMMA ($14.3{\mu}m$) are 62.4, 59.4, 70.3, 303 and 203.6[$bar{\cdot}m/s$], respectively. And flame propagation velocity during plastic dust explosions for prediction of explosive damage was estimated using a flame propagation model based on the time to peak pressure and flame arrival time in dust explosion pressure assuming the constant burning velocity.

The Actual Conditions and Needs for Housing Remodeling among the Elderly Households with Adult Children (노부모-성인자녀 동거 가구의 주택개조 실태 및 요구)

  • Kim, Mi-Hee;Oh, Ji-Young
    • Journal of the Korean housing association
    • /
    • v.20 no.2
    • /
    • pp.77-86
    • /
    • 2009
  • The purpose of this study was to examine the household characteristics, the actual residential environment of the elderly living with their offsprings together in Gwangju. We also evaluated their satisfaction with the needs for remodeling of their houses and the different opinions about those things between the elderly and their off springs. We used comparative and descriptive T-test in statistical analysis. The results were as follows. There were more families living in the detached houses than those living in the apartments. The average size of the houses was 100.8 square meters. The mean residence period was 13.5 years. The sons were usually the legal householders. The residents who experienced remodeling before reassigned the furniture and installed the bathtub, which was designed to be sat on comfortably in a common. A few residents installed safety system such as alarms for incident fire or gas, convenient knobs for handling and faucets for running hot or cold water separately. After the installation of alarms, convenient knobs of windows or door, Customer satisfaction for those things were quite high. But that for the installation of safety bar were the lowest in contrast. The most things the old wanted to change were to rearrange bedrooms and bathrooms on the first floor and to decorate them in westernized styles. They didn't need to set up safety bars or shower instrument for modulating heights. The second generation wanted to install the blinds or curtains more than the third generations.

A Study on the Response Technique for Toxic Chemicals Release Accidents - Hydrogen Fluoride and Ammonia - (독성 화학물질 누출사고 대응 기술연구 - 불산 및 암모니아 누출을 중심으로 -)

  • Yoon, Young Sam;Cho, Mun Sik;Kim, Ki Joon;Park, Yeon Shin;Hwang, Dong Gun;Yoon, Jun heon;Choi, Kyung Hee
    • Korean Journal of Hazardous Materials
    • /
    • v.2 no.1
    • /
    • pp.31-37
    • /
    • 2014
  • Since the unprecedented hydrogen fluoride leak accident in 2012, there has been growing demand for customized technical information for rapid response and chemical accident management agencies including the Ministry of Environment, the National Emergency Management Agency, and the National Police Agency need more information on chemicals and accident management. In this regard, this study aims to provide reliable technical data and guidelines to initial response agencies, similar to accident management technical reports of the US and Canada. In this study, we conducted a questionnaire survey and interviews on initial response agencies like fire stations, police stations, and local governments to identify new information items for appropriate initial response and improvements of current guidelines. We also collected and reviewed the Canada's TIPS, US EPA's hydrogen fluoride documents, domestic and foreign literature on applicability tests of control chemicals, and interview data, and then produced items to be listed in the technical guidelines. In addition, to establish database of on-site technical information, we carried out applicability tests for accident control data including ① emergency shut down devide, safety guard, shut down valve, ground connection, dyke, transfer pipe, scrubber, and sensor; ② literature and field survey on distribution type and transportation/storage characteristics (container identification, valve, ground connection, etc.); ③ classification and identification of storage/transportation facilities and emergency management methodslike leak prevention, chemicals control, and cutoff or bypass of rain drainage; ④ domestic/foreign analysis methods and environmental standards including portable detection methods, test standards, and exposure limits; and ⑤ comparison/evaluation of neutralization efficiency of control chemicals on toxic substances.

Mechanical Properties of External Thermal Insulation Composite System with Quasi-Non-Combustible Performance (준불연 외단열시스템의 역학적 특성에 관한 연구)

  • Choi, Ki-Sun;Ha, Soo-Kyung;Oh, Keun-Yeong;Park, Keum-Sung;Ryu, Hwa-Sung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.21 no.5
    • /
    • pp.507-518
    • /
    • 2021
  • The application of an adhesive calcium carbonate-based hybrid insulation board with quasi-combustibility in the external thermal insulation composite system(ETICS) ensures effective thermal performance and fire safety. This study aimed to conduct a mechanical test of the quasi-non-combustible hybrid insulation board as well as its constituent materials to obtain the basic data for the structural design of the adhesive ETICS. Test specimens were fabricated based on domestic and foreign test standards to examine and evaluate their tensile, compressive, flexural, and shear strengths. The strength characteristics of the quasi-non-combustible hybrid insulation board were identified from the test results, which verified that the minimum required physical properties suggested by the current KS M ISO 4898 were met. Furthermore, the quasi-non-combustible ETICS used in this study was found to be suitable for use as an external insulation system for walls unless subjected to continuous gravity load, such as a heavy exterior finish.