• Title/Summary/Keyword: Fire Safety System

Search Result 1,204, Processing Time 0.024 seconds

An Improvement Plan on Fire Safety Management of Public Institutions: Focusing on the Case of Elementary and Secondary Schools (공공기관 소방안전관리 실태조사를 통한 개선방안에 관한 연구 : 초·중등학교를 중심으로)

  • Han, Sang-Pil
    • Fire Science and Engineering
    • /
    • v.34 no.3
    • /
    • pp.85-90
    • /
    • 2020
  • The aim of this study is to identify ways to improve fire safety management of elementary and junior high schools, which can prevent potentially dangerous situations and establish a rapid response system for fire-related emergencies by analyzing existing fire safety management public institutions. We investigated the expertise, prevention ability, preparation ability, and operation form of fire safety managers working in elementary and secondary schools in Kangwon Province. A questionnaire composed of 26 items was completed by 238 fire safety managers. Results shows that the perception of fire safety management is considerably high, while the ability of the fire safety manager to prepare for and cope with an accident still needs improvement.

A Study on Developing the Educational Program for the Emergency Response against Fire Accidents in KTX (고속철도 화재사고 비상대응 교육프로그램 개발에 관한 연구)

  • Kim, Si-Gon;Park, Min-Kyu
    • Journal of the Korea Safety Management & Science
    • /
    • v.11 no.2
    • /
    • pp.41-49
    • /
    • 2009
  • In January, 2005, the "Railroad Safety Act" was presented, preparing the systematic equipment that allows several railroad operators to consider the railroad safety issue, and each of the railroad operative institutions accepted such situation that the construction of the emergent system of coping, resulting in the construction of the emergent system of coping with the railroad fire accident through the relevant study to improve the railroad security efficiency against fire. This study tried to present the on developing the emergent educational program for coping with the KTX fire accident, which is distributed to the spot, to the railroad emergency staff for improving the railroad security efficiency against fire through the education of systematic and efficient emergent countermeasure procedures against fire accidents the fire accident in KTX.

Classification of Hazard Events and Causes for Railway Fire Accident (열차 화재안전성 향상을 위한 위험사건 정의 및 원인분류 연구)

  • Kwak, Sang-Log;Wang, Jong-Bae;Park, Chan-Woo;Park, Joo-Nam
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1163-1167
    • /
    • 2007
  • Many railway safety measures are carried out after Daegue subway fire accident. Such as replacement of train interior material, fire extinguish and toxic gas evacuation facilities, exercise on emergency response, setting up of national safety management system, and safety technology research. But these safety measures are not considered by system safety due to lack of risk and hazard information. In order to assess fire risk on system level, we proposed hazard events and causes classification for railway fire accident risk analysis.

  • PDF

A Study on the Effective Smoke Exhaust Amount of Load-Tunnel with Semi-Transverse Ventilation - Balanced Exhaust Case - (도로터널 반횡류식 환기방식의 최적배연 풍량산정에 관한 연구 - 균일배기의 경우 -)

  • Rie, Dong-Ho;Yoo, Ji-Oh;Shin, Hyun-Jun
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.2 s.74
    • /
    • pp.46-51
    • /
    • 2006
  • The smoke exhaust system is one of the effective systems to save lives when fire occurs underground. This study presents a complete analysis of effective smoke exhaust and smoke characteristics for a fire occurring with a transverse ventilation system use as a smoke exhaust system. The performance of the smoke management system was studied by computer modeling using FDS version 3.1. A fire size of 20MW was used for tunnel with balanced exhaust transverse ventilation. The smoke management design and the procedure as simulated in this study are also compliant to the tunnel construction and fire codes of Korea.

A Study on Efficient Improvement Ways of Fire Protection Management System (방화관리제도의 효율적 개선방안에 관한 연구)

  • Kook, Hyeong-Ho;Jo, Dae-Ho;Kong, Ha-Sung
    • Fire Science and Engineering
    • /
    • v.22 no.1
    • /
    • pp.115-127
    • /
    • 2008
  • Fire protection management system has been introduced to prevent structure fire since establishment of Fire Prevention Act. Nevertheless, Damage by fires is continue. The main purpose of this study is to discuss approaches to improve fire protection management system into the fire prevention properties. Now fire protection management system has lots of the problems in managerial and systematical aspects. To improve these a unified fire protection management system must be establish by suggests revision of a unified Fire Prevention Act and foundation of Fire Prevention Institution, reform educational system for the fire safety directors would be essential to includes environment improvement, enhancement of certification requirements and education, a standardized computational management system of the fire protection properties must be build for efficient fire protection operations.

The Problems and Improvements of Process to Predict Fire Risk of a Building in Performance Based Design (성능위주설계에서 화재위험성 예측 과정의 문제점 및 개선방안)

  • Lee, Se-Myeoung
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.3
    • /
    • pp.145-154
    • /
    • 2014
  • Performance based design(PBD) is the method to make a fire safety design against them after predicting the factors of fire risk in a building. Therefore, predicting fire risk in a building is very important process in PBD. For predicting fire risk of a building, an engineer of PBD must consider various factors such as ignition location, ignition point, ignition source, first ignited item, second ignited item, flash over, the state of door and fire suppression system. But, it is difficult to trust fire safety capacity of the design because the process in Korea' PBD is unprofessional and unreasonable. This paper had surveyed some cases of PBD that had been made in Korea to find the problems of the process to predict fire risk. And it have proposed the improvements of process to predict fire risk of a building.

Flame Extinguishing Characteristics of Clean Gaseous Agents and Effects of Additives (가스계 청정소화약제의 소화특성과 첨가제에 따른 영향)

  • Shin, Chang-Sub;Kim, Sung-Min
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.6
    • /
    • pp.95-99
    • /
    • 2008
  • Halon was known as a cause of the ozone layer destruction. In 1987, it was designated as one of the ozone-layer-destroying materials in the Montreal Protocol. Therefore substitutes of Halon agent has been developed including inert gas extinguish system, which is one of the most widely used fire extinguishing system. This study intended to increase the efficiency of inert gas extinguishing agent by using inert gas additives. As IG-541 shows high extinguishing power, the experiment was performed to measure the effects of gaseous additives to it. Cup-burner fire extinguishing apparatus was used with n-Heptane fuel. Among many of pure inert gaseous agents, Helium showed the most excellent extinguishing power. When Helium was added to IG-541, fire extinguishing power was increased and the concentration of oxygen in chimney also risen. By adding Helium to IG-541, the effectiveness of inert gas fire extinguishing system is able to be increased.

THE DEVELOPMENT OF A UV FLAME DETECTOR FOR THE AUTOMATIC FIRE SUPPRESSION SYSTEM FOR ENGINE COMPARTMENT FIRES

  • Lim, Sung-Mook;Jung, Ki-Chang;Kim, Eung-Sik;Kim, Hong
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.590-597
    • /
    • 1997
  • In this work, a new type of UV flame detection system was developed. In order to measure the performance of UV flame detector, various kinds of experiments was performed. The results show that the maximum response time of the UV flame detector is 0.2 seconds when the detection distance is one meter The advantages of this system include wide area, high speed response and high sensitivity. After testing the W flame detector in engine compartment it detected fire within 0.09 seconds and extinguished within 5 seconds. Hence, the UV flame detector can be applied in automatic fire suppression system for automobiles.

  • PDF

A Development of Assessment Model for Maintenance of Type R Fire Alarm System in the Building

  • Lee, Su-Kyung;Yoo, Sang-Bin;Nam, Yang-Won
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.633-640
    • /
    • 1997
  • Type R fire alarm is required intelligent buildings and height buildings which was based on automatic system. But in Korea, maintenance of fire alarm system is very poor. In this study, we developed assessment model for the type R fire alarm system which was assessed by using 96 checklist items. The assessment model was tested through the actual 4 buildings with type R fire alarm system. It is shown that present model can be applied for the assessment of all buildings through the examination of the suitability of assessment model by actual assessment. Also, it was made easily fire manager to carry out checklist for type R fire alarm system in buildings.

  • PDF

Combustion Characteristics Analysis of a Non-class 1E Cable for Nuclear Power Plants according to Aging Period (경년열화 기간에 따른 원자력발전소용 비안전등급 케이블의 연소특성 분석)

  • Kim, Min Ho;Lee, Seok Hui;Lee, Min Chul;Lee, Sang Kyu;Lee, Ju Eun
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.5
    • /
    • pp.22-29
    • /
    • 2020
  • In this study, combustion and smoke release characteristics of a non-class 1E cable for nuclear power plants were investigated according to aging period. The aging was reproduced through an accelerated aging method for interval of 10 years :10, 20, 30 and 40 year, which was applied the Arrhenius equation. The cable was subjected to accelerated aging. In order to understand combustion and smoke release characteristics, the cone calorimeter test was performed according to the standard code of KS F ISO 5660-1. Heat release rate, mass loss rate, average rate of heat emission and smoke production rate were examined through cone calorimeter test. Fire performance index, fire growth index and smoke factor were derived from test results for the comparison of quantitative fire risk. When comparing the fire performance index and the fire growth index, the early fire risk tends to decrease as aging progresses, which might be attributed from the fact that the volatile substances of cables were evaporated. However, when comparing the heat release rate, average rate of heat emission and mass loss rate, which represent the mid and late periods of the fire risk, the values of accelerated aging cables were much higher than those of non-aged cable, which signifies the unstable formation of the char layer resulted in the change in the performance of flame retardants. In addition, the results from the smoke characteristics show that the accelerated aging cables were lager than the non-aged cables in terms of overall fire risk. These results can be used as baseline data when assessing fire risk of cables and establishing fire safety code for nuclear power plants.