• Title/Summary/Keyword: Fire Safety Index

Search Result 107, Processing Time 0.024 seconds

Efficiency Estimation of Toxicity Free Eire Resistance Cable

  • Yoon, Hun-Ju;Hon, Jin-Woong
    • Transactions on Electrical and Electronic Materials
    • /
    • v.3 no.3
    • /
    • pp.34-38
    • /
    • 2002
  • In this paper, efficiency estimation of toxicity fee fire resistance cable experiments was measured smoke density of toxicity free fire resistance polyolefin insulation material and electric field dependence of tree shape in low density polyethylene (LDPE). One of the most serious causes of failure in high-voltage cables, can be an electrical discharge across an internal gab or void in the insulating material. Treeing due to partial discharge is one of the main causes of breakdown in the insulating materials and reduction of the insulation life. Therefore the necessity for establishing a method to diagnose the aging of insulation materials and to predict the breakdown of insulation and research of the fire resistance character has become important. First, we have studied on electric field dependence of tree shape in LDPE about treeing phenomena occurring on the high electrical field. Second, the measurement method is the attenuation quantity of irradiation by smoke accumulating with in a closed chamber due to non-flaming heat decomposition and flaming combustion. A main cause of fire-growth and generating toxic gas when, it bums, should be dealt with great care in life. safety design. The fire gases were occurred carbon monoxide and decomposition than in polyolefin due to incomplete combustion of PVC, which has high content of carbon in chemical compound.

A Study on the Combustion Characteristics of Phenol Foam (페놀 폼의 연소특성에 관한 연구)

  • Park, Hyung-Ju
    • Fire Science and Engineering
    • /
    • v.24 no.1
    • /
    • pp.122-127
    • /
    • 2010
  • The combustion characteristics of phenol foam were analysed using variable external irradiation level (20, 25, 35, 50, and $70kW/m^2$) and in the mixture gas of oxygen/nitrogen. The oxygen index were carried out from the oxygen index tester (KS M ISO 4589-2) and ignition time, critical heat flux, and mass loss rate were carried out from the mass loss calorimeter (ISO 5660-1). As the results of this study, the critical heat flux and average mass loss rate were $28.99kW/m^2$ and $0.56{\sim}1.77g/m^2s$ respectively at the variable external irradiation level. And the limited oxygen index were 45.1% in mixture gas of oxygen/nitrogen. In conclusion, we knew that phenol foam had the best performance than other foam materials in fire safety from all data of this study.

Development of Performance Index for Ubiquitous Building Fire Safety System - Focused on Sprinkler System - (유비쿼터스 건물 화재안전시스템을 위한 성능지수 개발 - 스프링클러 시스템을 중심으로 -)

  • Kim, Jong-Hoon;Roh, Sam-Kew
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.592-597
    • /
    • 2009
  • 실시간으로 건물의 소방시스템에 대한 관리를 위해서는 어느 부분에서 이상상태가 나타났다고 한다면, 그 부분에서 이상이 발생되었기 때문에 부분적, 그리고 전체적으로 화재안 전성능수준이 얼마나 하락되었는지를 나타 낼 수 있는 성능지수의 계산 체계가 필요하다. 이러한 성능지수의 체계는 정보를 받아보는 사람들이 시스템에서 발생된 이상이 전체적인 안전수준 하락에 얼마나 영향을 주는 것인지를 쉽게 인지할 수 있도록 하는 데에 기여할 수 있다. 이러한 결과는 건물의 화재안전수준을 나타내는 효율지표로 사용될 수 있을 뿐만 아니라, 광대역규모의 소방 관리에서도 활용도 높은 지수로 사용될 것이라 생각된다. 본 지수 산정체계는 U-건물 소방방화시설관리 운용시스템의 성능 효율지수 산정을 위한 시스템으로 개발되었다.

  • PDF

A Study on Response Time Index for Sprinkler Head (스프링클러 헤드의 응답시간지수 측정)

  • 태순호;이병곤
    • Journal of the Korean Society of Safety
    • /
    • v.5 no.3
    • /
    • pp.51-55
    • /
    • 1990
  • This study describes the engineering approach adopted to investigate sprinkler head during the early stage of a fire when they are subjected to convective heating and low gas velocities. Comparions are made between the parameters derived using basic methods, ie. ramp test, for evaluating sprinkler parameters(time constant, response time index) is illustrated. Evidence is presented that the propotion of heat loss by conduction from a sprinkler element may very typically employed in the rate of rise test. This fact alone may justfy the precautionary need to perform a limited number of rate of rise tests to confirm a sprinklers capacity to function correctly in reasonably unfavourable yet realistic conditions. The work is aimed primarily at meeting the needs of sprinkler industry.

  • PDF

An Empirical Study on Importance of Evaluation Factors for Improvement of Fire Emergency Medical Service (소방응급의료서비스 향상을 위한 평가요인의 중요도에 관한 실증적 연구)

  • Hwang, Dong-Wan;Kwon, Young-Hee;Kim, Jeon-Soo;Kang, Yun-Jin;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.4
    • /
    • pp.71-80
    • /
    • 2014
  • This study is performed to determine the priorites of the evaluation factors for the improvement of fire emergency medical service by increasing it's efficiency to protect the people's lives effectively, and by recognizing it's mid-long term development. Based on the output of the analysis, the critical evaluation factors of the fire emergency medical services to be improved shall be identified, and shall be intended to use strategically for increasing the efficiency of all the activity in the EMT service, and also for providing the basic date to product and manage the good quality services. To calculate the priority of the evaluation factor for each level as shown on this study, AHP(anaysis hierarchy process) with pairwise comparison method is applied. According to the priority analysis for the evaluation factors in main category (evaluation zone), 'medical service professional aspect' is recognized as highest one, and 'service infrastructure aspect', 'service management aspect' are indicated in order. According to the priority analysis for the evaluation factors in evaluation index, 'professional personal arrangement' in the service infrastructure aspect, 'appropriateness and timeliness of emergency medical care' in the medical service professional aspect, and 'clinical training' in the service management aspect are respectively recognized as most important factors.

Realization of Information Visualization of Electric Power Monitoring System for MV/LV Distribution Customers

  • Kim Jae-Chul;Chu Cheol-Min;Knag Bong-Seok;Kim Yeong-Il;Choi Duck-Su;Kim Kwang-Soon;Ryu Seung-Ki
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.3
    • /
    • pp.287-294
    • /
    • 2006
  • Recently, switchboards for MV/LV distribution customers have been united and digitalized rapidly. This paper proposes the effective information visualization method for the data measured from cubicle switchboards for MV/LV distribution customers. We developed the algorithm that analyzes abundant data measured by switchboards and displays them to overall users, such as fire information index, power condition index, switchboard safety index, and power diminution index. Using a touch screen made users to operate it easily. User interface was also improved by taking graphic visualization. We guess the information visualization method suggested in this paper shows the new direction that heavy electrical equipments including switchboards are going to develop in the future.

A Study on the Preparation of Powder Coatings Containing Halogen-Free Flame Retardant and Fire Safety (Halogen-Free 난연제를 포함하는 파우더 코팅소재 제조 및 화재안전성 연구)

  • Lee, Soon-Hong;Chung, Hwa-Young;Kim, Dae-In;Noh, Tae-Joon
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.4
    • /
    • pp.47-58
    • /
    • 2011
  • Halogen free intumescent flame retardants(IFRS), such as the mixture of melamine phosphate(MP) and char forming agents(pentaerythritol(PER), di-pentaerythritol(DiPER), tris(2-hydroxyethyl) isocyanurate(THEIC)), were prepared and characterized. Polypropylene(PP)/$IFR_S$ composites were also prepared in the presence of ethylene diamine phosphate(EDAP) as a synergist and used into flame retardant PP powder coatings. Thermoplastic PP powder coatings at 20 wt% flame retardant loading were manufactured by extruded and then mechanical cryogenic crushed to bring them in fine powder form. These intumescent flame retardant powder coatings($IFRPC_S$) were applied on mild steel surface for the purpose of protection and decorative. It is a process in which a $IFRPC_S$ particles coming in contact with the preheated mild steel surface melt and form a thin coating layer. The obtained MP flame retardant was analyzed by utilizing FTIR, solid-state $^{31}P$ NMR, ICP, EA and PSA. The mechanical properties as tensile strength, melt flow index(MFI) and the thermal property as TGA/DTA and the fire safety characteristics as limiting oxygen index(LOI), UL94 test, SEM were used to investigate the effect of $IFRPC_S$. The experimental results show that the presence of $IFR_S$ considerably enhanced the fire retardant performances as evidenced by the increase of LOI values 17.3 vol% and 32.6 vol% for original PP and $IFRPC_S$-3(PP/MP-DiPER/EDAP), respectively, and a reduction in total flaming combustion time(under 15 sec) in UL94 test of $IFRPC_S$. The prepared $IFRPC_S$-3 have good comprehensive properties with fire retardancy 3.2 mm UL94 V-0 level, LOI value 32.6%, tensile strength $247.3kg/cm^2$, surface roughness Ra $0.78{\mu}m$, showing a better application prospect. Through $IFRPC_S$-2(PP/MP-PER/EDAP) and $IFRPC_S$-3 a better flame retardancy than that of the $IFRPC_S$-1(PP/MP/EDAP) was investigated which was responsible for the formed more dense and compact char layer, improved synergy effect of MP and PER/DiPER.

An Experimental Study on Droplet Size according to Discharge Coefficient of Sprinkler Head (스프링클러 헤드의 방수상수에 따른 물방울 크기에 관한 실험적 연구)

  • Hur, Min Noung;Shin, Changsub
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.4
    • /
    • pp.16-21
    • /
    • 2017
  • The sprinkler system is a basic fire extinguishing system that uses water as an extinguishing agent. In order to evaluate the fire extinguishing performance of the sprinkler system, information such as the discharge angle, discharge speed, discharge pressure, flow rate, and water droplet size of the installed head are required. However, there is a lack of research on droplets size compared to other requirements. In this study, to evaluate the extinguishing characteristics of sprinkler system, the droplet size distribution was measured for various types of sprinkler heads actually used. The size of the droplet was measured using laser diffraction method. The 50% cumulative volume distribution ($D_{v50}$) according to discharge coefficient(K factor) was $540{\mu}m{\sim}695{\mu}m$ for K50, $542{\mu}m{\sim}1,192{\mu}m$ for K80, $980{\mu}m{\sim}1,223{\mu}m$ for K115 and $1,188{\mu}m{\sim}1,234{\mu}m$ for K202. Based on the measured results, the vaeiance of the droplet particle distribution and the distribution ($D_{v50}$) according to discharge coefficient(K factor) was $540{\mu}m{\sim}695{\mu}m$ for K50, $542{\mu}m{\sim}1,192{\mu}m$ for K80, $980{\mu}m{\sim}1,223{\mu}m$ for K115 and $1,188{\mu}m{\sim}1,234{\mu}m$ for K202. Based on the measured results, the vaeiance of the droplet particle distribution and the Rosin-Rammler index value are presented. As a result of the fire simulation with FDS, it was confirmed that the performance difference occurs according to the water droplet size distribution even when the same amount of water is used. Therefore, the extinguishing performance of the sprinkler system should be evaluated considering the droplet size distribution according to the sprinkler head type.

A study on the improvement plan of fire simulation training for the improvement of fire response ability : Focusing on the fire simulation training of business facility (화재대응능력 향상을 위한 화재모의훈련의 개선방안에 관한 연구 : 업무시설의 화재모의훈련 중심으로)

  • Kim, Bongjun;Ryu, Guhwan
    • Journal of Digital Convergence
    • /
    • v.18 no.9
    • /
    • pp.191-198
    • /
    • 2020
  • In this study, in order to propose an improvement plan for fire simulation training to improve fire response capability, fire simulation training is conducted for three business facilities, and changes according to whether training materials are used and whether the response time for each response stage is reflected in the training evaluation. The response posture and response ability of the training participants were observed and analyzed. As a result of the analysis, it was analyzed that most of the training participants improved their participation in training, response posture, and response ability when the use of training textbooks and response time for each response stage were reflected in the training evaluation. In the event of a fire simulation training, a number of training materials that can similarly implement the fire situation are used to improve and maintain the fire response capabilities (fire notification and fire report, initial extinguishing, and evacuation) of the training participants, and the target time for each response step. The result was that it can be used as a useful index for improving fire response capability and improving fire simulation training in the future and feedback only when quantitative training evaluation is conducted based on this setting.

Evaluation of Occupational Exposure to Noise and Heat stress in Coal-fired Power Plants (석탄화력발전소 작업자의 소음과 온열 스트레스에 대한 노출 평가)

  • Jiwoon Kwon;Kwang-Myong Jang;Sungho Kim;Se-Dong Kim;Miyeon Jang;Jiwon Ro;Seunghyun Park
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.33 no.4
    • /
    • pp.464-470
    • /
    • 2023
  • Objectives: This study evaluated occupational exposures to noise and heat stress during routine non-outage works in three coal-fired power plants in the Republic of Korea. Methods: The data were collected during the summer of 2020. Full shift noise exposure of 52 workers were measured using noise dosimeters. Heat stress of 16 worksites were measured for 70 minutes using wet-bulb globe temperature monitors. Results: The noise dosimetry results revealed time-weighted averages that ranged from 47.5 to 88.9 dBA. 2 out of 52 noise measurements exceeded 85 dBA. Based on the arithmetic mean, the coal service group showed the highest level at 80.2 dBA by job tasks. Noise exposures exceeding 85 dBA were measured in the coal service and plant operator group. Heat stress index measurements ranged from 20.3℃ to 37.2℃. 1 out of 9 indices measured in coal facilities and 4 out of 7 indices measured in boiler house exceeded 1 hour TWA during moderate work. Heat stress indices measured from boiler houses were significantly higher than those measured from coal equipment. Conclusions: The results show that overexposure to noise and heat stress may be encountered during routine non-outage work activities in coal-fired power plants. Appropriate actions should be taken to reduce future health outcome from occupational exposure to noise and heat stress in the industry.