• Title/Summary/Keyword: Fire Safety Index

Search Result 107, Processing Time 0.025 seconds

Development of Risk Assessment Index in Special Management Target Facilities According to the Fire Occurrence Factors (화재발생 요인에 따른 특정관리대상시설등의 위험도 평가 지수의 분석 및 개발)

  • Park, Mi Yun;Park, Jong Bok;Park, Jae Hak
    • Journal of Korean Society of Disaster and Security
    • /
    • v.5 no.2
    • /
    • pp.61-70
    • /
    • 2012
  • The range of special management target facilities is seperated by the building sector and the field of civil engineering. In the present study, the risk analysis was performed, related to fire occurred for the last five years, in the field of residential and non-residential facilities in buildings. Most of fire incidents occurred in residential and non-residential facilities was the cause of the electrical, and the resulting casualties were also very high. Therefore, based on the results, the risk evaluation index was developed, identifying the causes of fire occur and doing the fire vulnerability analysis for each facility. The result of this study can be utilized safety management to these facilities for the future, especially, inducing a more specialized and intensive safety management.

Study on the Development of Qualification for Fire Identification and Estimation (화재감식평가 자격개발에 관한 연구)

  • Lee, Su-Kyung;Kim, Young-Chul;Oh, Hyung-Sool;Jung, Ki-Sin;Song, Dong-Woo;Kim, Tae-Hoon
    • Fire Science and Engineering
    • /
    • v.24 no.3
    • /
    • pp.78-85
    • /
    • 2010
  • Currently, there are various institutions performing fire investigation and identification, such as fire stations and police stations as well as institutes related to fire safety, etc. And the manpower working at the institutions reaches a large number of persons. But there is no objective index on the expertise of the persons. In this paper, we suggested the examination criteria through job analysis and the enforcement method of the exam system. And we developed suitable exam subjects and exam content specifications for qualification of fire identification and estimation that investigate a fire cause, combustion, escape circumstances and fire facilities at the scene of a fire, survey the fire damage and analysis fire cause, etc. It will increase the public trust to develop national technical qualification items of the fire identification and estimation engineer.

A Study of Effect of the Radiative Heat Flux on the Evacuation of Agents (화재에 의해 발생하는 복사열이 재실자의 피난거동에 미치는 영향에 관한 연구)

  • Bae, Sungryong;Kim, Jung-Yup;Shin, Hyun-Joon;Ryou, Hong-Sun
    • Fire Science and Engineering
    • /
    • v.28 no.1
    • /
    • pp.31-36
    • /
    • 2014
  • Recently, the safety assessments with using the various evacuation programs are performed for improving the performance of fire and evacuation safety in the building. Generally, the evacuation programs can simulate the human behavior in fire situation by applying the variation of the movement speed and Fractional Effective Dose (FED) index in the smoke. However, if the simulation is performed without optional setting around the fire, the agents do not avoid the fire and they move through the fire. Therefore in this study, we define the radiative repulsion force which exists between the fire and the agents. Moreover, we modify the Helbing's movement model by adding the radiative repulsion force. As a result of the modified movement model, all agents move around the fire and they do not enter the upper bound area of radiative heat flux, $2.4kW/m^2$. From these results, we verified the reliability of the modified movement model.

Analysis on the Effects of the Heat Loss Coefficient on the Operation Time of Sprinkler in Compartment Fire (구획 화재에서 스프링클러 열 손실계수 변화에 따른 작동 시간 분석)

  • You, Woo Jun
    • Fire Science and Engineering
    • /
    • v.32 no.5
    • /
    • pp.34-39
    • /
    • 2018
  • In this study, the experiment conditions for the variation of heat release rate in compartment space were constructed to analyze the effects of fire spread and the operation time of sprinkler in accordance with the heat loss of the sprinkler's heat element. The compartment composed of fire board (width = 0.3 m, height = 0.5 m, length = 3.0 m), are manufactured to measure the temperature distributions in the inner space, the mass loss rate and heat release rate during the experiment of N-heptane pool fire test. Also, the operation time of sprinkler is analyzed with the installation of sprinkler and C-factor using Fire Dynamics Simulator Ver.6 under the experiment conditions. The results show that the operation time of sprinkler, which has RTI $100(m{\cdot}s)^{0.5}$ operating temperature $70^{\circ}C$, is 30 s~60 s for C-factor = 0 and 1, 62 s~92 s for C-factor = 3, and 120 s over for C-factor = 5, respectively.

Heat Risk Assessment of Wood Coated with Silicone Compounds (실리콘 화합물로 도포된 목재의 열위험성 평가)

  • Jin, Eui;Chung, Yeong-Jin
    • Fire Science and Engineering
    • /
    • v.33 no.2
    • /
    • pp.9-19
    • /
    • 2019
  • Experiments on the combustion characteristics of untreated wood specimens and those treated with four types of silicone compounds were carried out using a cone calorimeter according to the ISO 5660-1 standard. 3-Aminopropyltrimethoxysilane (APTMS), 3-(2-aminoethylamino) propylmethyldimethoxysilane (AEAPMDMS), and 3-(2-aminoethylamino) propyltrimethoxysilane (AEAPTMS) were used as the silane compounds. The flame retardants were synthesized with sodium silicate and amino silane compounds. The measured time to ignition after combustion at an external heat flux of $50kW/m^2$ was 9 s to 11 s. Time to ignition was marked with a delayed value in the 3 s to 5 s range. The peak heat release rate ($HRR_{peak}$) was reduced by 5 to 20% compared with the uncoated specimen, and AEAPMDMS showed the highest initial fire risk. The total heat release (THR) was decreased by 1 to 22%. Compared to the untreated specimen, the fire performance index (FPI) of the specimens coated with silicone sol compounds increased by 1.5 to 2.2 fold. The fire growth index (FGI) of the AEAPMDMS specimen was increased by 30% and the others were decreased by 93 to 94%. Therefore, the fire risk of wood coated with silicone compounds was improved in terms of the heat risk properties.

A Study on Risk Analysis of Social Disaster (사회재난의 재난위해분석에 관한 연구)

  • Lee, Kwan-Hyoung;Yi, Waon-Ho;Yang, Won-Jik
    • Journal of Korean Society of Disaster and Security
    • /
    • v.9 no.2
    • /
    • pp.15-21
    • /
    • 2016
  • According to the disaster statistics issued by the Ministry of Public Safety and Security, traffic accidents, fire, collapses and others are classified into twenty-three (23) categories. In the past, disasters were mainly caused by the influence of nature, such as typhoon or drought. On the other hand, as society has become city-centered, social disasters' types, frequencies and scales are becoming more diversified and ever-increasing. However, there are no specific criteria and assessment methods that can measure degrees of social disasters-related risks objectively. Therefore, this study targeted traffic accidents, fire and collapses from major social disasters, utilized data that are related to occurrence rate, scale of casualties and scale of property loss in past eight years, and calculated the disaster risk index using the distance (Euclidean distance) between two points on the 3D spatial coordinates, in order to make the objective assessment by social disaster type possible. These results will enable the objective evaluation of risk index of major social disaster to be used as the foundational data when building the national disaster management system.

Evaluation Methods of Flame Retardants for Wooden Cultural Properties

  • Son, Dong Won;Han, Gyu-Seong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.42 no.5
    • /
    • pp.590-596
    • /
    • 2014
  • Wooden cultural heritages of Korea have been destroyed by fire in many cases. As a result, a number of methods to protect wooden cultural properties against fire were introduced. A way of protecting wooden cultural properties installations of fire equipments such as sprinkler, fire alarm system, or fire extinguisher. Another way of protecting wooden cultural properties is to treat them with flame retardants for their safety. Development of a very effective flame retardant with a good performance without affecting danchung and wood quality is required. At the same time, methods of evaluating flame retardant treated woods should be devised to assess their efficacy. In this study, combustion characteristics using cone-calorimeter, limit oxygen index, moisture absorption, iron corrosive and weathering were analyzed to evaluate the flame resistance efficacy and performance of flame retardants treated woods. The evaluation methods of flame retardants for wooden cultural heritage were suggested.

Case Study on Advanced Fire and Explosion Index (화재폭발지수 개선에 대한 사례 연구)

  • Na, Gun Moon;Seoe, Jae Min;Lee, Mi Jeong;Baek, Jong-Bae
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.6
    • /
    • pp.78-84
    • /
    • 2020
  • The F&EI technique is one of the risk assessments with many advantages. It can save time and effort compared to quantitative risk assessment (QRA). By using the evaluation result of this technique, it is possible to check the effectiveness of the investment cost. In addition, a relative risk ranking can be created and used to establish the facility management cycle and to prioritize investment. However, evaluating the target process can be evaluated more than the actual risk since the LCCF, a loss prevention measure, is too limited. In addition, calculating premiums via this method can result in excessive premiums, making it difficult to evaluate the risk precisely. Therefore, new safety guard was added to the LCCF of the F&EI risk assessment with reference to HAZOP and LOPA techniques. Newly added LCCFs are Deflagration arrester, Check valve, SIS, and Vacuum beaker, etc. As a case study, F&EI risk assessment was performed on Acetone storage tank of a API (Active pharmaceutical ingredient) plant to compare actual MPPD. The estimated loss amount was 592,558$ for the existing technique and 563,571$ for the improved technique, which was reduced by about 5% compared to the previous one.This proved that a more precise evaluation is possible and that the efforts for safety at the workplace are reflected in the evaluation results.

Combustion Characteristics of Cypress Specimens Painted with Solutions of Boron Compounds (붕소 화합물로 처리된 편백나무 시험편의 연소특성)

  • Chung, Yeong-Jin;Jin, Eui
    • Fire Science and Engineering
    • /
    • v.32 no.2
    • /
    • pp.1-6
    • /
    • 2018
  • The combustion characteristics of cypress wood coated with boric acid (BA) and ammonium pentaborate (APB) were examined using a cone calorimeter according to the ISO 5660-1 standard. As a result, the combined specimens of boric acid and ammonium pentaborate (BA/APB) led to an improved fire performance index due to their synergistic effect. In addition, the total heat release values of the specimen coated with the boron compounds were 6.1~14.1% lower than that of the base specimen. The total smoke release rate (TSR) of the specimens coated with the boron compound decreased throughout the combustion process, except for BA/APB. The maximum concentration of carbon monoxide was reduced by 15.8~25.5%. In general, wood treated with flame retardants has a lower fire hazard.

Fire safety evaluation of the subway car's interior materials (지하철 내장재료의 재료특성에 따른 화재안전도 평가)

  • Lee Duck-Hee;Jung Woo-Sung;Lee Cheul-Kyu;Kim Sun-Ok
    • Proceedings of the KSR Conference
    • /
    • 2003.10c
    • /
    • pp.327-332
    • /
    • 2003
  • We investigated the fire characteristics of the subway electric car's interior materials and evaluated the safety of it. The testing methods are ISO 4589-2 for Limited Oxygen Index, ISO 5658-2 for surface flame spread, ISO 5660-1 for Heat Release Rate, ASTM E 662 for smoke density and BS 6852 Annex B.2 for gas toxicity. The materials of seven organization including KNR were tested. Most of the materials are under the levels of the foreign country's demand. We also reported the test methods of other countries and compared it to ours.

  • PDF