• Title/Summary/Keyword: Fire Route

Search Result 128, Processing Time 0.022 seconds

A Study for Optimal Evacuation Simulation by Artificial Intelligence Evacuation Guidance Application (인공지능 피난유도설비 적용에 따른 최적 대피시뮬레이션 연구)

  • Jang, Jae-Soon;Kong, Il-Chean;Rie, Dong-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.3
    • /
    • pp.118-122
    • /
    • 2013
  • For safe evacuation in the fire disaster, the evacuees must find the exit and evacuate quickly. Especially, if the evacuees don't know the location of the exit, they have to depend on the evacuation guidance system. Because the more smoke spread, the less visibility is decreasing, it is difficult to find the way to the exit by the naked eye. For theses reasons, the evacuation guidance system is highly important. However, the evacuation guidance system without change of direction has the risk that introduce to the dangerous area. In the evacuation safety assessment scenario by the evacuation simulation has the same problem. Because the evacuee in the simulation evacuate by the shortest route to the exit, the simulation result is same like the evacuation without the evacuation guidance system. In this study, it was used with MAS (Multi Agent System)-based simulation program including the evacuation guidance system to implement the change of evacuation by fire. Using this method, confidence of evacuation safety assessment can be increase.

A Study on the Development of Fire Alarm System with Evacuation Lighting and Voice Alarm Functions (피난조명 및 음성경보 기능을 내장한 화재경보시스템 개발에 관한 연구)

  • Lee, Gun-Ho;Choi, Su-Gil;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.32 no.4
    • /
    • pp.25-34
    • /
    • 2018
  • This study investigated the development of a fire alarm system with evacuation lighting and voice alarm functions. The performance of a fire detector and system with independently built-in evacuation lighting and voice alarm functions was confirmed for early recognition of fire and to allow visibility of the evacuation route in the event of fire. This new system satisfied model recognition and product testing technological standards with 1.62 lx average illumination, 89.7 dB average sound and 86.1 dB average voice. From additionally testing the evacuation performance of this new system, it was confirmed that the evacuation time decreased by 63.08% to 67.82% under the experimental conditions compared to conventional systems. The new system can minimize fire damage by setting off voice alarms to prevent failure of fire recognition and by flashing emergency lighting to secure the minimum required visibility range for evacuation. Therefore, it is considered that it will be utilized as a fire alarm system with appropriateness and usefulness by considering people with hearing or visual impairment.

Measurement of the Visibility of the Smoke Images using PCA (PCA를 이용한 연기 영상의 가시도 측정)

  • Yu, Young-Jung;Moon, Sang-ho;Park, Seong-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.11
    • /
    • pp.1474-1480
    • /
    • 2018
  • When fires occur in high-rise buildings, it is difficult to determine whether each escape route is safe because of complex structure. Therefore, it is necessary to provide residents with escape routes quickly after determining their safety. We propose a method to measure the visibility of the escape route due to the smoke generated in the fire by analyzing the images. The visibility can be easily measured if the density of smoke detected in the input image is known. However, this approach is difficult to use because there are no suitable methods for measuring smoke density. In this paper, we use principal component analysis by extracting a background image from input images and making it training data. Background images and smoke images are extracted from images given as inputs, and then the learned principal component analysis is applied to map of as a new feature space, and the change is calculated and the visibility due to the smoke is measured.

Derivations of Positive Pressure Condition for Development of Foldable Safe Pathway in Railway Tunnel Fires (철도터널화재용 접이식 대피통로 개발을 위한 양압 조건 도출)

  • Kim, JiTae;Ro, Kyoungchul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.1
    • /
    • pp.284-289
    • /
    • 2019
  • The Korea Foldable safe pathway system is an evacuation support system to get temporary evacuation route in railway tunnel and large space fires. A prevention smoke screen is unfolded in fires and it is needed to prevent heat and smoke from fire source. Therefore, ventilation system for positive pressure condition is equipped with foldable safe pathway system. Numerical analyses of temperature and pressure distribution with distance from fire source were performed considering fire scenario of new train vehicle. The smoke temperatures did not exceed $200^{\circ}C$ that distance from the fire source was more than 20 m and smoke pressure was reduced with distance from fire source. Maximum smoke pressure was 14 Pa and average pressure was 6 Pa in position of prevention smoke screen. As results, to install foldable safe pathway system, ventilation system is need to maintain 6 Pa positive pressure condition.

Life-Road : Development of an Emergency Evacuation Application using Augmented Reality and Beacon (Life-Road : 증강현실과 비콘을 사용하는 긴급대피용 애플리케이션 개발)

  • Myeon-gyun Cho
    • Journal of Digital Policy
    • /
    • v.2 no.4
    • /
    • pp.11-15
    • /
    • 2023
  • Recently, a fire suddenly broke out in a crowded theater, and many people were unable to find an escape route, becoming entangled, injured, and suffocating from smoke inhalation, resulting in a large-scale fire accident. Even though most of the people were young, they were unable to evacuate. If they had been elderly, it could have resulted in greater casualties. In particular, since it is difficult to receive accurate location information from GPS indoor, there is an urgent need for location-based services using beacons and an emergency evacuation system that intuitively shows evacuation routes in augmented reality using smart-phones. In this paper, an augmented reality-based emergency evacuation smartphone app was developed based on identifying fire locations and evacuation routes using beacons and fire sensors (IoT). In the future, if the proposed system is applied to indoor spaces where people are crowded, rapid evacuation will be possible even in a sudden fire accident, minimizing human damage.

A Study on an Adaptive Guidance Plan by Quickest Path Algorithm for Building Evacuations due to Fire (건물 화재시 Quickest Path를 이용한 Adaptive 피난경로 유도방안)

  • Sin, Seong-Il;Seo, Yong-Hui;Lee, Chang-Ju
    • Journal of Korean Society of Transportation
    • /
    • v.25 no.6
    • /
    • pp.197-208
    • /
    • 2007
  • Enormously sized buildings are appearing world-wide with the advancement of construction techniques. Large-scaled and complicated structures will have increased difficulties for dealing with safety, and will demand well-matched safety measures. This research introduced up-to-date techniques and systems which are applied in buildings in foreign nations. Furthermore, it proposed s direct guidance plan for buildings in case of fire. Since it is possible to install wireless sensor networks which detect fires or effects of fire, the plan makes use of this information. Accordingly, the authors completed a direct guidance plan that was based on omnidirectional guidance lights. It is possible to select a route with concern about both time and capacity with a concept of a non-dominated path. Finally, case studies showed that quickest path algorithms were effective for guiding efficient dispersion routes and in case of restriction of certain links in preferred paths due to temperature and smoke, it was possible to avoid relevant links and to restrict demand in the network application. Consequently, the algorithms were able to maximize safety and minimize evacuation time, which were the purposes of this study.

A Study on Smoke Extract Vents in a Subway with Screen door by Evacuation Performance Evaluation through RSET vs. ASET based on Computer Simulations (스크린도어가 설치된 지하철 승강장의 대피안전성 평가를 통한 제연환기구의 방재성능 개선방안 연구)

  • Park, Hyung-Joo;Lee, Young-Jae;Shin, Dong-Cheol;Baek, Dong-Ho
    • Journal of the Korean Society for Railway
    • /
    • v.10 no.5
    • /
    • pp.511-519
    • /
    • 2007
  • This study provides comprehensive design improvements covering technical issues concerning life safety matter In case of fire train stoppage in the middle of a tunnel. Recently Government announced that most of subway platforms will have screen doors in 3 years. Therefore, many fire safety engineers considered that they may contribute on life safety on train stoppage in tunnel. Especially The screen door can protect platform from smoke along tunnel ceiling when fire train stopped in tunnel. The study showed that platform ventilation ducts and the a tunnel ventilation chimney in the middle of tunnel in exiting subway tunnel could not guarantee life safety ability in terms of RSET vs. ASET comparison. Furthermore during evacuation process many peoples may be threatened from the smoke spread from the origin of fire. Although only additional vertical route can be installed in tunnels In order to decrease RSET, it will costs high or no spaces remains in outside on the road. The study suggested that increase of ASET can be best solution without additional escape route, therefore alternative design methods suggested on the base of simulation results. Finally the study shows alternative methods can give good result in terms of evacuation performance evaluation. The evacuation performance evaluation helps the decision-maker to determine the preferred alternatives or upgrades to existing tunnel infrastructure and other measure to meet safety objectives. Finally, the study details the effectiveness of measures the can be taken to reduce the risk of incidents in subway tunnels.

Development of Video Work Manual for Rock-Drill Data In Fire Service (소방에서의 도상훈련 기초자료 영상화작업 매뉴얼 개발)

  • Cho, Jae-Kwan;Park, Hee-Jin;Hwang, Inn;Kwon, Hayrran
    • The Korean Journal of Emergency Medical Services
    • /
    • v.6 no.1
    • /
    • pp.103-128
    • /
    • 2002
  • As a result of trying the various manufacturing methods considering the reality of manpower and equipments with this manual, the following standardized procedures and contents can be suggested. (1) Since tools presenting Rock-Drill data must formalize the order of explanation although explainers are different, it will be valid that it is configured by existing power point method rather than by web document type. Composition of contents are selected on the basis of defence card and survey and then 8 items including initial screen, peripheral conditions, mobilization route, general conditions, use and structure by floor, department of vehicle consideration in activities and end screen are included. (2) Making methods and cautions of data included and used in power point are as follows ; - It was most effective that objects of fire fighting and location of neighboring fire fighting water were expressed by electronic map and drawing of inner building was made by scanning it after paining general architecture drawing(plan by each floor) rather than using drawing tools of EXCEL program or CAD drawing. And it was helpful to simplify contents of architecture drawing to wall, stairs and gate in understanding them. - Photographing of video data should be taken to show available fire fighting facilities in fire, use of planned space and the whole inner structure of each floor from the inside of fire fighting buildings and to display play time between 10 sec. and 1 min, for obstacles to distance from adjacent buildings or passage of special vehicles and fire fighting water from the outside of the building. - File format of video data taken in this way is most suitable to use wmv(window media video) or asf(advanced streaming format) type in consideration of time required for export, screen quality, file capacity and play type in Rock-Drill through network. - Still screen(photo) is more effective to express the department of fire fighting vehicles or other equipments than using video. (3) In configuration work of power point, hyper link was used most and configured to see any part at any situation like web document and then uniformity of presentation order of power point was complemented. (4) In case of sales facilities with the area of $35.557m^2$, the time of 22 hours and 30 minutes for five days was taken with five persons. Therefore, when eight-hour works a day were calculated, the whole process of video work for Rock-Drill can be finished with three day works.

  • PDF

An Architectural Study on Optimum Evacuation Route of School Facilities (학교시설의 피난동선 최적화에 대한 건축계획적 연구)

  • Kim, Hee-Kyo
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.1
    • /
    • pp.177-183
    • /
    • 2021
  • This study chiefly aims to clarify optimize evacuation circulation which can be applied to architectural planning through the analysis of educational facilities. On the planning phase, the evacuation circulation of buildings are defined through the zoning of plans and sections based on the functions and purposes. It is very important to consider efficient evacuation circulation under the circumstances of disasters such as fire and earthquake etc, and it is directly related with the lives of people in the educational facilities. This study tries to find out methods can be applied to architectural planning and architectural design through optimized circulation after the analysis and understanding of behavioral characteristics of human.

The Risk Factors of Acute Cardiovascular and Neurological Toxicity in Acute CO Poisoning Patients and Epidemiologic Features of Exposure Routes (급성 일산화탄소 중독 환자에서 급성 심혈관계, 신경학적 독성의 위험요인과 노출 경로의 역학적 특성)

  • Park, Jinsoo;Shin, Seunglyul;Seo, Youngho;Jung, Hyunmin
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.18 no.1
    • /
    • pp.34-41
    • /
    • 2020
  • Purpose: This study evaluated aggressive hyperbaric oxygen therapy (HBOT) by understanding various exposure routes of acute carbon monoxide (CO) poisoning, the risk factors causing acute cardiovascular, and neurological toxicity caused by poisoning. Methods: A retrospective study was conducted based on the medical records of 417 acute CO poisoning patients who visited the emergency care unit from March 2017 to August 2019. The exposure routes, HBOT performance, age, sex, medical history (hypertension, diabetes mellitus, ischemic heart disease, heart failure), intentionality, loss of consciousness (LOC), intake with alcohol or sedatives, and initial test results (carboxyhemoglobin (COHb), troponin-I, electrocardiography, echocardiography, brain MRI) were examined. Comparative analysis of the clinical information was conducted between the groups that showed acute cardiovascular toxicity and neurological toxicity, and groups that did not. Results: Among 417 patients diagnosed with acute CO poisoning, 201 cases (48.2%) were intentional, and charcoal briquette was the most common route (169 patients (40.5%)). Two hundred sixteen cases (51.8%) were accidental, and fire was the most common route (135 patients (32.4%)). The exposure route was more diverse with accidental poisoning. Three hundred ninety-nine patients were studied for acute cardiovascular toxicity, and 62 patients (15.5%) were confirmed to be positive. The result was statistically significant in intentionality, LOC, combined sedatives, initial COHb, HTN, and IHD. One hundred two patients were studied for acute neurological toxicity, which was observed in 26 patients (25.5%). The result was statistically significant in age and LOC. Conclusion: Active HBOT should be performed to minimize damage to the major organs by identifying the various exposure routes of CO poisoning, risk factors for acute cardiovascular toxicity (intentionality, LOC, combined sedatives, initial COHb, HTN, IHD), and the risk factors for acute neurological toxicity (age, LOC).