Development of Fire Evacuation Guidance System using Characteristics of High Frequency and a Smart Phone (고주파 특성과 스마트폰을 활용한 화재 대피 안내시스템 개발)

  • Jeon, Yu-Jin;Jun, Yeon-Soo;Yeom, Chunho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.10
    • /
    • pp.1376-1383
    • /
    • 2020
  • Although studies on fire evacuation systems are increasing, studies on the evacuation of evacuees in indoor spaces are insufficient. According to the latest research, it has been suggested that the use of high frequency might be effective for identifying the location of evacuees indoors. Accordingly, in this paper, the authors intend to develop evacuation location recognition technology and fire evacuation guidance system using high-frequency and a smartphone. The entire system was developed, including an app server, evacuees location recognition unit, an evacuation route search, an output unit, and a speaker unit based on Wi-Fi communication. The experimental results proved the possibility of the effectiveness of the system in the fire situation data. It is expected that this study could be used as an essential study of a fire evacuation guidance system using high frequency data in case of fire.

A Study on the Visibility Measurement of CCTV Video for Fire Evacuation Guidance (화재피난유도를 위한 CCTV 영상 가시도 측정에 관한 연구)

  • Yu, Young-Jung;Moon, Sang-Ho;Park, Seong-Ho;Lee, Chul-Gyoo
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.7 no.12
    • /
    • pp.947-954
    • /
    • 2017
  • In case of a fire in urban large structures such as super high-rise buildings, evacuation guidance must be provided to the occupants in order to minimize human deaths and injuries. Therefore, it is essential to provide emergency evacuation guidance when a major fire occurs. In order to effectively support evacuation guidance, it is important to identify major items such as fire location, occupant position, escape route, etc. Also, it is important to quickly identify evacuation areas where residents can safely evacuate from a fire. In this paper, we analyze the CCTV video and propose a method of measuring visibility of the evacuation zone from the smoke caused by the fire in order to determine the safety of evacuation area. To do this, we first extract the background video from the smoke video to measure the visibility of the specific area due to smoke. After generating an edge-extracted image for the extracted background video, the degree of visibility is measured by calculating the change in the edge strength due to smoke.

A study on quantitative risk assessment for railway Tunnel fire (철도터널에서 차량화재시 정량적 위험도 평가에 관한 연구)

  • Yoo, Ji-Oh;Nam, Chang-Ho;Jo, Hyeong-Je;Kim, Jong-Won
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.12 no.4
    • /
    • pp.307-319
    • /
    • 2010
  • As we learned in Daegu subway fire accident, fire in the railway tunnel is prone to develop to large disaster due to the limitation of smoke control and smoke exhaust. In railway tunnel, in order to ensure fire safety, fire prevention and fighting systems are installed by quantitative risk assessment results. Therefore, in this research, developed the program to establish quantitative risk assessment and suggested quantitative safety assessment method including fire scenarios in railway tunnel, fire and evacuation analysis model, fatality estimate model and societal risk criteria. Moreover, this method applys to plan preventing disaster for Honam high speed railway tunnel. As results, we presented the proper distance of escape route and societal risk criteria.

A Study of Evacuation Route Guidance System using Location-based Information (위치기반 정보를 활용한 비상대피경로 안내 지원시스템 개발)

  • Kim, Ho-Kyeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.9
    • /
    • pp.18-23
    • /
    • 2017
  • The shipyard quay process struggles to control workers and maintain a secure working environment because of the presence of at least 1,000 people. Therefore, safety accidents such as an explosion or a fire are likely to occur. With the recent increase in safety accidents at shipyards, the requirements for safety and process monitoring have been strengthened. Major shipyards are conducting researchto monitor the process in real time and to detect the work environment for safety. In this paper, we propose a safe and accurate evacuation route based on the information of the dangerous area and the user's location based on a mobile application to reduce the casualty accidents in the presence of many personnel in a concentrated area. To do this, we analyze the trend of the fire escape system on the ground building, compare various algorithms for escape route calculation, select appropriate algorithms for this study, and perform programming. A basic experiment was conducted to confirm the results. The proposed method is expected to be used in large ship construction sites, passenger ships and large public facilities to reduce accidents in the case of a safety accident.

The Development of High Pressure Long Distance Fire-fighting Hose with Phosphorescent Performance (축광 성능을 갖는 고압용 장거리 호스 개발에 관한 연구)

  • Han, Yong-Taek;Na, Byung-Gyun;Choi, Jin-Seong;Min, Se-Hong
    • Fire Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.63-69
    • /
    • 2017
  • This study describes the development of a long-distance hose for ultra-high pressure operation, which can be used in conjunction with an ultra-high pressure pump and can be effectively applied to the fire suppression of high-rise buildings and a long, large tunnels. Also, it has phosphorescent properties, which can help to secure the withdrawal route of the fire-fighters when they are threatened by the fire. We developed an ultra-high pressure hose aiming at a pressure of 3 MPa and a flow rate of 2000 lpm and developed an ultra-high pressure fire hose that can withstand this very high pressure by using a double jacket, triple polyurethane coating and warf (Wp) of 52. In order to ensure the performance of the developed ultra-high pressure hose, its structure, appearance, leakage at high pressure, length and elongation were inspected by a certified certification agency, who also subjected it to a peeling test, friction test, breaking pressure test and free fall test. Also, it was studied in addition to the luminescent high-pressure hose for fire-fighting. In the phosphorescence test, the luminance measurement value was more than the reference value of the luminance test after 40 minutes, which confirmed that its performance was satisfactory for fire-fighting products. In the future, if such an ultra-high pressure fire hose were commercialized and applied in the field, it could contribute to securing improved fire suppression and safer exit from fires, as compared to the fire hoses currently used in the suppression of fires in skyscraper buildings and long tunnels.

How Phenolic Composites were chosen - In Case of England (4) (페놀 컴포지트 실용화의 길 - 영국의 경우 (CASE STUDY 4))

  • Nomaguchi, Kanemasa;Forsdyke, Ken L.;Brown, Denver E.
    • Composites Research
    • /
    • v.17 no.4
    • /
    • pp.75-81
    • /
    • 2004
  • In applying phenolic composites in the marine market, Mech-Tool Engineering Ltd. U.K., for instance, they developed, based on their fire approval certificated technologies, many products such as bulkheads for boats, firewalls, blastwalls, blastrelief, escape route or tunnels, small modules, or safety havens and so on. These are one of very best applications with phenolic composites which may inspire you another fire protecting tools of your new products for our societies as well as those products.

A Study on Characteristics of Spatial Configuration and Human Evacuation Behavior in Multi-Plex Theater of Jinju (진주지역 복합영화관의 공간구조와 피난행태특성에 관한 연구)

  • Ahn, Eun Hee
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.7 no.3
    • /
    • pp.93-100
    • /
    • 2005
  • The purpose of this study is to investigate specific crowding areas resulted from diverse physical factors of multi-plex theaters in a fire evacuation, and more accurately predict the evacuation route of people. To achieve these purpose, the architectural characteristics of three multi-plex theaters in Jinju have been chosen, and the evacuation experiments through the computer simulation called Simulex were carried out for each on the these theaters. The conclusions from this study are as follows: (1) Crowding usually happens cross areas between theater inside and corridors, and Crowding rate depending on the number of cross areas. (2) It is necessary to design the escape routes being employed ordinary times. And the egress routes planning should be integrated into space programming at the early stage of building design.

  • PDF

Numerical Study on the Improvement Heat and Smoke Control System in Old Subway Station on Train Fire (수치해석을 통한 노후 지하철 역사 내 열차 화재 시 제연모드 개선에 관한 연구)

  • Kim, Hyo-Gyu;Baek, Doo-San;Yoo, Yong-Ho
    • Fire Science and Engineering
    • /
    • v.31 no.3
    • /
    • pp.88-96
    • /
    • 2017
  • The subway can transport a lot of people at a certain route at once, and the railway and the platform are underground, so it is advantageous to use the ground space efficiently. But If a fire occurs in a subway that is used by an unspecified number of people, such as the Daegu Subway Fire Disaster, many casualties can occur. As a result of the previous research, it was confirmed that the performance of the ventilation system of the old subway platform was remarkably degraded. Therefore, in this study, based on the experimental results of the previous research, we confirmed the flow of the hot and CO flows according to the ventilation mode in the case of fire by three - dimensional numerical analysis. As a result, it was found that the old ventilation system could not maintain the hot air temperature below the reference value for 4 minutes based on the evacuation time of the platform, and when the ventilation performance was enhanced by adding Oversized Exhaust Ports at the upper part of the platform, And the temperature of the heat flow can be maintained.

A Study of Fire Shunt Guidance Based on Wireless Sensor Networks (무선 센서 네트워크 기반의 화재 대피 유도 연구)

  • Kim, Yong-Woo;Kim, Do-Hyeon;Kwak, Ho-Young;Park, Hee-Dong
    • Journal of Korea Multimedia Society
    • /
    • v.11 no.11
    • /
    • pp.1547-1554
    • /
    • 2008
  • This paper proposes a fire shunt guidance system model based on rule, it presents suitable shunt route in real-time according to collected fire information of the building inside using wireless sensor networks. So, this system model is composed of the sensor alert module, the behavior suggestion module, and the emergency device control module. The sensor alert module uses rule-base algorithm that monitored the information to collect periodically in wireless sensor networks. And, the behavior suggestion module proposed a suitable behavior, this module supports to judge the fire area with danger sensor list. Additional, the emergency device control module controls a related emergency device according to the suggested behavior and to present on a control screen. We experiment the fire shunt guidance system based on Internet Web for operation verification of the proposed system. Consequently, this study supports people safety with the behavior suggestion according to the context information when an emergency situation happens.

  • PDF

Numerical Study on Air Egress Velocity in Vestibule Pressurization System : Damper Locationfor Uniform Air Egress Velocity in the case of Two Fire Doors (부속실 가압 시스템의 방연풍속에 관한 수치해석적 연구: 2개 출입문이 존재할 경우 균일한 방연풍속을 얻기 위한 댐퍼 위치 선정방법)

  • Seo, Chanwon;Shin, Weon Gyu
    • Fire Science and Engineering
    • /
    • v.28 no.6
    • /
    • pp.1-7
    • /
    • 2014
  • Vestibule pressurization system should produce uniform air egress velocity to prevent the intrusion of smoke into escape route when fire accidents occur inside a building and fire doors are open for evacuation of people. Air supplying units in the vestibule need to be arranged by taking account of the location of doors and the volume of the vestibule. In this study, computational fluid dynamics (CFD) simulations were conducted for the vestibule where two doors are installed varying the location of a damper and louver angle. From simulations, we found that when the damper in the vestibule is located at the center of the wall opposite to two fire doors, the uniform air egress velocity can be obtained.