• Title/Summary/Keyword: Fire Road

Search Result 201, Processing Time 0.029 seconds

A Study of Classification of Road Tunnel for Fire Safety (안전성 향상을 위한 도로터널 등급에 관한 연구)

  • Yoo, Ji-Oh;Rie, Dong-Ho;Shin, Hyun-Jun
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.3 s.71
    • /
    • pp.112-119
    • /
    • 2005
  • In road tunnel, in order to prevents an accident and minimize the damage of an accident in the case of fire, safety facilities and equipments are integral parts. The type and amount of safety facilities are based on tunnel type and length, traffic flow rate, etc. Therefore many countries use a tunnel classification system that categories tunnel into groups, and specifies the necessary emergency equipment for each group. In this study, for the purpose of classifying tunnel based on tunnel ist investigated the domestic and foreign standards and regulations for safety of road tunnel. As a results, we suggest the method of classification of tunnel by traffic performance, tunnel grade, the volume of traffic, fraction of HGV, rules or regulations for transports of dangerous good through tunnel.

Time-Temperature Curve of road tunnel for fire (도로터널 내 화재에 따른 시간-온도 가열곡선 도출)

  • Choi, Min-Jung;Jang, Chang-Il;Lee, Sang-Woo;Kim, Joon-Mo;Won, Jong-Pil
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.713-716
    • /
    • 2008
  • This study is performed to propose a standard to evaluate fire protection assessment for concrete structures during a fire on road tunnel. Recently, a number of road tunnels have been rapidly increased and fire risk also multiplyed according to extend tunnel length, due to natural features and environmentally-friendly road construction in domestic. But we have not yet been prescribed appropriate time-temperature curve for tunnel fire. Therefore we presented fire design model and investigated time-temperature curve proposed by a foreign country considering traffic, a kinds of vehicles which are a basis of heat rate.

  • PDF

Namsan 1.2.3 Tunnel accident disaster countermeasures (남산 1·2·3호 터널사고에 대한 재난대응방안)

  • Lee, Jeong-Il
    • Journal of the Korea Safety Management & Science
    • /
    • v.15 no.1
    • /
    • pp.69-75
    • /
    • 2013
  • Namsan road are taxis in the engine room fires (07/14/2011 18:05) in the tunnel, and the driver of the vehicle was 100 passenger car and more than 500 evacuated were disasters. Pole road vehicles within the tunnel if there is a fire tunnel fire occurred at a two-way evacuation difficult and rapid evacuation is difficult and mass casualties are concerned, the number of casualties is feared. In this study, by considering the problems and improve the Namsan 1,2,3 Tunnel In case of fire, the best disaster response is to come up with ways.

Fire Detection Performance Experiment of the Water Jet Nozzle Position Control Type Automatic Fire Extinguishing Facility for Road Tunnels (도로터널용 방수노즐 위치제어형 자동소화설비의 화재감지성능실험)

  • Kim, Chang-Yong;Kong, Ha-Sung
    • Fire Science and Engineering
    • /
    • v.33 no.1
    • /
    • pp.85-91
    • /
    • 2019
  • This study evaluated the fire detection performance of an automatic fire extinguishing system for road tunnels, which combines flame wavelength detection technology with flame image detection technology. This fusion technique to improve the fire detection capability can reduce the damage caused by the fire suppression by locating the fire source in the fire and discharging the pressurized water only at the fire source. Experiments were conducted to determine the position of a fire source when a $70cm{\times}70cm$ target was placed at a distance of 15 m, 20 m, 25 m, 30 m, and 35 m, respectively, in a situation where there is a flame and smoke in a tunnel. The performance of the ultraviolet and triple wavelength infrared (IR3) sensors was attenuated due to the interference of thick smoke. In addition when the flame was blocked by thick smoke, the image sensor sensed the smoke and emitted a fire signal.

Study of the Characteristics of Smoke Spread by an Installing Smoke Barrier in Medium Length Road Tunnel (중규모 도로터널의 제연경계벽 설치에 따른 연기확산특성)

  • Baek, Doo-San;Lee, Seung-Chul
    • Fire Science and Engineering
    • /
    • v.30 no.5
    • /
    • pp.9-17
    • /
    • 2016
  • In the case of a medium length road tunnel, the installation of a smoke control facility is not mandatory so users can suffer considerable injuries if a fire breaks out. Therefore, this study analyzed the high-temperature air and toxic gas generated by fire proliferating with time when a smoke barrier is not installed and when the installation interval is 100, 150, 200, and 250 m through 3-dimensional numerical analysis, evacuation simulation, and Quantitative Risk Assessment Methodology targeting the medium length road tunnel. As a result, the diffusion of the high-temperature air and toxic gas occurring from the a fire was delayed when the smoke barrier was installed in a medium length road tunnel compared to that when it was not installed. In addition, when the installation interval of a smoke barrier was 100m and the numerical analysis target was 100m, the diffusion of high-temperature air and toxic gas generated by the fire was delayed more than in the other cases, which was most suitable for tunnel users to evacuate.

Can the Expansion of Forest Roads Prevent Large Forest Fires? (산림 내 도로의 확대는 대형산불을 막을 수 있는가?)

  • Suk-Hwan Hong;Mi-Yeon An;Jung-Suk Hwang
    • Korean Journal of Environment and Ecology
    • /
    • v.37 no.6
    • /
    • pp.439-449
    • /
    • 2023
  • This study was conducted to verify the role of forest roads in the extinction of large forest fires in Korea. The study area was the forest fire-damaged area of Gangneung City, Gangwon Special Self-Governing Province, in April 2023, which is one of the areas with the highest road density among the major forest fires that have occurred so far. The scope of the forest fire damage area was confirmed through on-site survey, and the intensity of the fire was carried out through Sentinel-2 satellite imagery analysis. After that, the relationship between the damage range and intensity and the forest road was examined. About 59.6 km of roads were built within 50 m from the boundary of the forest fire damage area, which can easily access the entire 149.1 ha of forest fire damaged area. The road density is as high as 168.9 m/ha. All forests that were fragmented by roads were fragmented into 83 places, and all of these forests could be judged to have spread by spotting fire. As a result of analyzing the distribution of damage intensity by distance from the road to see the extent of damage according to the ease of access of fire extinguishing vehicles, it was confirmed that the proportion of areas with low-intensity damage has increased sharply even from 75 m or more away from the road. The results of analyzing the distribution of damage intensity by altitude to see the extent of damage according to the ease of access of fire extinguishing showed that the proportion of areas with low-intensity damage increased as the altitude increased, while the proportion of areas with damage of more than strong intensity decreased as the altitude increased. It was confirmed that there is no data that roads inside or adjacent to forests in the forest fire area of Gangneung City are effective in extinguishing forest fires. These results are contrary to the logic that increasing the road density in forests is effective in extinguishing forest fires. In the case of this fire area in Gangneung City, the road density is 43 times higher than the current road density in Korea claimed by the Korea Forest Service of 3.9 m/ha. This study suggests that roads can be a hindrance to extinguishing forest fires.

A study on the relationship among traffic accidents, fire occurrences and tunnel characteristics in local road tunnels (국내 도로터널내 발생 교통사고, 화재사고 및 터널특성 관계 연구)

  • Kim, Hyo-Gyu;Lee, Chang-Woo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.6 no.3
    • /
    • pp.199-211
    • /
    • 2004
  • As the length of local tunnels is getting longer, the demand for tunnel safety attracts more attention. But only a few information can be found concerning traffic and fire accidents occurred in local tunnel, and full-fledged studies had not been carried out to fulfill the expectation of the tunnel users. This study aims at collecting and analyzing the data on traffic and fire accidents in local road tunnels and providing the fundamental data for the tunnel fire safety evaluation. Focus is placed on quantifying the relationship among traffic accidents, fire occurrences and tunnel characteristics.

  • PDF

Analysis of Interaction Between Recirculating Flow Near The Jet Fan and The Backlayer of Smoke in a Road Tunnel (도로터널에서 제트팬 근처의 재순환유동과 연기 역류현상의 상호작용 분석)

  • Kim, Chang-Kyun;Ryu, Jin-Woong;Kim, Sung-Joon
    • Journal of Industrial Technology
    • /
    • v.25 no.A
    • /
    • pp.191-201
    • /
    • 2005
  • A numerical analysis was done for a tunnel fire in a 1000m road tunnel. A cartesian coordinate was adopted to make a computational grid sytem which has 448,000 computational cells. A transient flow phenomena in the tunnel was simulated by the commercial code of PHEONICS from the ignition of fire to 600 seconds by the interval of 100 seconds. Total computational time of about 44 hours was required to get a convered solution in each time step. The purpose of this research is to analyze of the backlayering pheonomena and recirculation flow in a tunnel. The compuational results say that the backlayering does not happens near the fire of vehicle in this case because the vehicle fire is located at the outside of recirculation zone of flow ocuured near the jet fan. In this research, onset of backlayering pheonomena could be escaped if jet fan is set 95m in front of the the fire of vehicle.

  • PDF

A NUMERICAL STUDY OF THE VENTILATION AND FIRE SIMULATION IN A ROAD TUNNEL (도로터널 환기/제연 시스템 시뮬레이션)

  • Park Jong-Tack;Won Chan-Shik;Hur Nahmkeon;Cha Cheol-Hyun
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.207-212
    • /
    • 2005
  • In designing a ventilation system of a road tunnel, a possibility of using the system as a smoke control system in case of a tunnel fire has to be considered. In the present study, a numerical simulation on ventilation system is performed considering jet fan operations and moving traffic. A fire-mode operation by reversing some fan operations in case of a tunnel fire is also simulated. The results show that ventilation operation can control the pollutants effectively, and fire-mode operation can control smoke and temperature effectively to prevent a disaster.

  • PDF

Full-scale Fire Suppression Test for Application of Water Mist System in Road Tunnel (미분무수 소화시스템의 도로터널 적용을 위한 실물 화재 실험)

  • Han, Yong-Shik;Choi, Byung-Il;Kim, Myung-Bae;Lee, Yu-Whan;So, Soo-Hyun
    • Fire Science and Engineering
    • /
    • v.25 no.3
    • /
    • pp.51-56
    • /
    • 2011
  • The full-scale experiments are carried out to investigate the fire suppression characteristics of water-based fire fighting systems in a road tunnel. Applied systems are the low-pressure water spray system at 3.5 bar and the high-pressure water mist system at 60 bar. The water flow rate of the high-pressure system is one sixth only of the water spray system. A passenger car and a heptane fuel pan with area of $1.4m^2$ are used as fire sources. A blower system is installed at the tunnel exit to realize the longitudinal ventilation conditions (0.9~3.8 m/s) in the tunnel. Temperatures from the fire source to the down-stream direction are measured by K-type thermocouple trees. The experimental results show that the cooling effect of the high pressure water mist system in the test conditions were equivalent to that of the low pressure water spray system for B-class fire.