• Title/Summary/Keyword: Fire Road

Search Result 202, Processing Time 0.022 seconds

Computer modelling of fire consequences on road critical infrastructure - tunnels

  • Pribyl, Pavel;Pribyl, Ondrej;Michek, Jan
    • Structural Monitoring and Maintenance
    • /
    • v.5 no.3
    • /
    • pp.363-377
    • /
    • 2018
  • The proper functioning of critical points on transport infrastructure is decisive for the entire network. Tunnels and bridges certainly belong to the critical points of the surface transport network, both road and rail. Risk management should be a holistic and dynamic process throughout the entire life cycle. However, the level of risk is usually determined only during the design stage mainly due to the fact that it is a time-consuming and costly process. This paper presents a simplified quantitative risk analysis method that can be used any time during the decades of a tunnel's lifetime and can estimate the changing risks on a continuous basis and thus uncover hidden safety threats. The presented method is a decision support system for tunnel managers designed to preserve or even increase tunnel safety. The CAPITA method is a deterministic scenario-oriented risk analysis approach for assessment of mortality risks in road tunnels in case of the most dangerous situation - a fire. It is implemented through an advanced risk analysis CAPITA SW. Both, the method as well as the resulting software were developed by the authors' team. Unlike existing analyzes requiring specialized microsimulation tools for traffic flow, smoke propagation and evacuation modeling, the CAPITA contains comprehensive database with the results of thousands of simulations performed in advance for various combinations of variables. This approach significantly simplifies the overall complexity and thus enhances the usability of the resulting risk analysis. Additionally, it provides the decision makers with holistic view by providing not only on the expected risk but also on the risk's sensitivity to different variables. This allows the tunnel manager or another decision maker to estimate the primary change of risk whenever traffic conditions in the tunnel change and to see the dependencies to particular input variables.

Development of virtual reality based simulator for road tunnel fire-training (가상현실 기반 도로터널 화재체험 시뮬레이터 개발)

  • Han, Yong-Shik;Choi, Byung-Il;Kim, Myung-Bae;Cha, Moo-Hyun;Kim, Byung-Su
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.214-217
    • /
    • 2008
  • An fire simulator has been developed for examining possibility of future engineering applications in the fire research field. This system composed of workstation on XP OS and HMD(Head Mounted Display) and visualized 3D walk-through type virtual reality graphics inside a tunnel in case of fire. By using a joystick and a viewpoint tracer, subjects can be experience interactive changes occurred both in graphics and surrounding sound.

  • PDF

Design of Road Spatial Information Database for Urban Disaster Management : Focused on Evacuation Vulnerability (방재관점에서의 도로 공간데이터베이스 설계 : 대피위험도를 중심으로)

  • Kim, Ji-Young;Kim, Jung-Ok;Kim, Yong-Il;Yu, Ki-Yun
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2007.04a
    • /
    • pp.413-416
    • /
    • 2007
  • To construct road spatial information database, it is the main object of this study that an analysis of road factors and furthermore this is used to the rescue activities in case of urban disasters. When urban disasters such as earthquake or explosion cause fire and collapses people of the affected region happen to evacuate. But only to manage roads and monitor traffic volume, the road data is designed and managed using digital topographic map so it is short that the design of road spatial data to prevent disasters. In this study, we tried to suggest the evaluative factors of evacuation to design database : road width, traffic volume, the fixed or movable obstacles installed, the surrounding environments that dominate the land-use planning, the uses, materials, structures, sizes, and densities of the buildings. Thus, these could provide fundamental data to determine the disasters management planning for evacuation and rescue activities, to evaluate the riskiness, and to draw up hazard information map.

  • PDF

A study on the operation characteristics of oversized exhaust port applicable to double-deck tunnel (복층터널에 적용 가능한 화재 연동형 대배기구 운영 특성 분석 연구)

  • Park, Jinouk;Yoo, Yongho;Kim, Yangkyun;Park, Byoungjik;Kim, Whiseong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.6
    • /
    • pp.887-895
    • /
    • 2019
  • Recently, the number of underground road development projects has been increasing to solve traffic problems in the national capital region and metropolitan areas with intensified overcrowding, and there has been a tendency to plan underground roads by applying a double-deck tunnel technology that has advantages in constructability and economical efficiency. The double-deck tunnel has a structure where one excavation section is divided into two parts and used as up and down lines, and is mainly used as a road for small vehicles only due to its low floor height. In addition, due to the small cross-sectional area, it has characteristics different from those of general road tunnels in terms of ventilation and disaster prevention. In this regard, this study proposed an operational plan that applies an oversized exhaust system, which is one of semi-transverse ventilation systems, to small cross-sectional tunnels like double-deck tunnel with low floor height, and a comparative analysis between smoke exhaust characteristics according to the fire occurrence locations and oversized exhaust systems was conducted using the Fire Dynamics Simulator (FDS). The results showed that unlike uniform exhaust, intensive smoke exhaust using the oversized exhaust port maximized the delay effect of smoke diffusion and limited the smoke within 50 m above and below the fire point.

Quantitative Fire Risk Assessment and Counter Plans Based on FDS and GIS for National Road Bridges (FDS와 GIS를 이용한 교량 화재 위험도의 정량적 평가 및 적용방안)

  • Ann, Ho June;Park, Cheol Woo;Kim, Yong Jae;Jang, Young Ik;Kong, Jung Sik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.6
    • /
    • pp.185-195
    • /
    • 2017
  • In recent years, unexpected bridge fire accidents have increased because of augmenting the number of traffic volumes and hazardous materials by the increment in traffics and distribution business. Furthermore, in accordance with the effort of using the under space of bridges, the ratio of occupied by combustible materials like oil tanker or lorry has been increased. As a result, the occurrence of bridge fire has been growing drastically. In order to mitigate the accident of bridge fire, risk assessment of bridge fire has been studied, however, practical risk models considering safety from users' viewpoints were scarce. This study represented quantitative risk assessment model applicable to national road bridges in Korea. The primary factors with significant impacts on bridge fire accidents was chosen such as clearance height, materials of bridges, arrival time of fire truck and fire intensity. The selected factors were used for Fire Dynamics Simulation (FDS) and the peak temperature calculated by FDS in accordance with the fire duration and fire intensity. The risk assessment model in bridge fire reflected the FDS analysis results, the fire damage criteria, and the grade of fire truck arrival time was established. Response plans for bridge fire accidents according to the risk assessment output has been discussed. Lastly, distances between bridges and fire stations were calculated by GIS network analysis. Based on the suggested assessment model and methodology, sample bridges were selected and graded for the risk assessment.

CFD analysis of the effect of hydrogen jet flame in road tunnel (도로 터널 내 수소 제트 화염에 대한 CFD 해석 연구)

  • Park, Jinouk;Yoo, Yongho;Kim, Hwiseong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.6
    • /
    • pp.629-636
    • /
    • 2022
  • Domestic eco-friendly vehicles currently account for 5.8% of the total registered vehicles in Korea. Hydrogen vehicles, one of the representative eco-friendly vehicles, have grown rapidly as they have been expanded to the market based on the government's policy to boost the hydrogen industry. Therefore, it is time to expand the safety review of hydrogen vehicles in various directions according to the increase in supply. In this study, the effect of internal heat damage was analyzed when a jet flame was generated by a hydrogen car in a road tunnel. It was simulated using Fluent, and the amount of jet flame injection was selected in consideration of the hydrogen tank capacity of commercial hydrogen vehicles for road tunnels. In addition, the study was conducted with the direction of the jet flame and the nozzle distance from the tunnel wall as variables. From the results, when the jet flame erupted in the road tunnel, high radiant heat emission of more than 20 kW/m2 was generated in most areas within ±5 m in the longitudinal direction based on the vehicle (spray nozzle) and 5 to 7 m in the lateral direction based on the adjacent tunnel wall.

Predefined Access Routes for Quick Response to Disaster Areas (방재경로 구축방안에 관한 연구 (지구단위 방재경로를 중심으로))

  • Jo, Yong-Chan;Lee, Chang-Ju;Sin, Seong-Il
    • Journal of Korean Society of Transportation
    • /
    • v.25 no.6
    • /
    • pp.43-53
    • /
    • 2007
  • In this research, in order to more concretely define the concept of the previously vaguely defined fire road, the authors propose new terminology called disaster prevention routes. These are defined as predefined access routes for the quick response to disaster areas. For this, the authors suggest selection techniques for disaster prevention routes considering characteristics of fire trucks and selected areas. The paper also includes legally-based ideas for the executive departments with exclusive responsibility for continuous management and supervision of disaster response. In addition, a case study is performed with a virtual scenario including the outbreak of fire in one borough of Seoul. This case study shows that the damage can be decreased by prompt access of fire trucks. The establishment of predefined access routes to disaster areas can help to protect citizens with more rapid response by emergency crews. Indirect benefits also include reduced congestion of roads through the prohibition of parking and stopping on the chosen roads.

Development of Fire Engine Travel Time Estimation Model for Securing Golden Time (골든타임 확보를 위한 소방차 통행시간 예측모형 개발)

  • Jang, Ki-hun;Cho, Seong-Beom;Cho, Yong-Sung;Son, Seung-neo
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.19 no.6
    • /
    • pp.1-13
    • /
    • 2020
  • In the event of fire, it is necessary to put out the fire within a golden time to minimize personal and property damages. To this end, it is necessary for fire engines to arrive at the site quickly. This study established a fire engine travel time estimation model to secure the golden time by identifying road and environmental factors that influence fire engine travel time in the case of fire by examining data on fire occurrence with GIS DB. The study model for the estimation of fire engine travel time (model 1) covers variables by applying correlation analysis and regression analysis with dummy variables and predicts travel time for different types of places where fire may occur (models 2, 3, 4). Analysis results showed that 17 siginificant independent variables are derived in model 1 and the fire engine travel time differs depending on the types of places where fire occurs. Key variables(travel distance, number of lane, type of road) that are included commonly in the 4 models were identified. Variables identified in this study can be utilized as indicators for research related to travel time of emergency vehicles and contribute to securing the golden time for emergency vehicles.

The study of ventilation system during fire in road tunnel with bi-directional or congested unidirectional traffic (교통정체가 심한 도로터널에 대한 화재시 제연방식에 관한 연구)

  • Yoo, Ji-Oh;Shin, Hyun-Jun;Nam, Chang-Ho
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.474-479
    • /
    • 2008
  • The purpose of this paper is to estimate the fire safety in tunnels with bi-directional and/or congested unidirectional traffic where there may be people on both sides of the fire. Therefore, the spread and movement of smoke are simulated by Fire Dynamic Simulator code under different ventilation systems, longitudinal, semi-transverse, large port exhaust system. And as quantitative risk index, FED (Fractional Effective Dose) for each ventilation system are calculated and compared by existed code developed previous research.

  • PDF