• 제목/요약/키워드: Fire Resistance Test

검색결과 390건 처리시간 0.027초

비재하 내화시험에 의한 섬유혼입 고강도 콘크리트 Mock-up 기둥의 내화성능 평가 (Evaluation of Fire Performance for High Strength Concrete Mock-up Column with Fiber by Unloaded Fire Test)

  • 송영찬;김용로;김욱종;이도범
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2009년도 추계 학술논문 발표대회
    • /
    • pp.97-100
    • /
    • 2009
  • Fire resistance properties and mechanical properties of high strength concrete mock-up column using organic fiber by KS F 2257 Methods of fire resistance test for elements of building construction and compression test was investigated for application of precast concrete column method of high rise building in this study. As a test result, it was appeared that ECC permanent form is available as fire resistance method of high strength concrete and new precast concrete construction method for facilitating construction of high rise building.

  • PDF

Fire resistance of high strength fiber reinforced concrete filled box columns

  • Tang, Chao-Wei
    • Steel and Composite Structures
    • /
    • 제23권5호
    • /
    • pp.611-621
    • /
    • 2017
  • This paper presents an investigation on the fire resistance of high strength fiber reinforced concrete filled box columns (CFBCs) under combined temperature and loading. Two groups of full-size specimens were fabricated. The control group was a steel box filled with high-strength concrete (HSC), while the experimental group consisted of a steel box filled with high strength fiber concrete (HFC) and two steel boxes filled with fiber reinforced concrete. Prior to fire test, a constant compressive load (i.e., load level for fire design) was applied to the column specimens. Thermal load was then applied on the column specimens in form of ISO 834 standard fire curve in a large-scale laboratory furnace until the set experiment termination condition was reached. The test results show that filling fiber concrete can improve the fire resistance of CFBC. Moreover, the configuration of longitudinal reinforcements and transverse stirrups can significantly improve the fire resistance of CFBCs.

터널 풍도슬라브에 사용된 내화패널의 적용성에 관한 실험연구 (An Experimental Study on the Application of Fireproof Panel in Tunnel Duct Slab)

  • 최우진
    • 한국재난정보학회 논문집
    • /
    • 제19권2호
    • /
    • pp.262-269
    • /
    • 2023
  • 연구목적: 터널에서 발생되는 화재로 인하여 구조물의 피해를 보호하기 위해 적용되는 PSC 슬래브에 부착된 내화패널의 성능을 평가할 목적으로 내화실험을 수행하였다. 연구방법: 내화실험은 RWS 화재 이력곡선 화재시간-온도곡선을 적용하였으며, 한국건설기술연구원(KICT)의 가열로를 이용하여 내화 성능을 평가하였다. 연구결과:국제터널학회(2004)에서 제시하는 기준으로 내화성능 실험을 실시한 결과, 내화패널과 콘크리트의 접촉면에서의 최대온도는 콘크리트에 손상을 주는 한계온도(380℃) 이하였으며, 접촉면과 25mm 이격된 지점에서의 최대온도는 철근에 손상을 주는 한계온도(250℃) 이하로 측정되었다. 실험결과로부터, 내화패널이 30mm두께로 부착된 PSC 슬래브 시험체는 내화성능을 가진 것으로 평가되었다. 결론: 터널이나 지하차도에서의 화재발생시 내화패널을 부착하는 보강방법은 화재로부터 구조물을 보호할 수 있으며 향후, 내화패널이 부착된 슬래브의 정적 성능시험을 수행하고, Pull-off test와 피로실험을 실시하여 내화패널의 부착성능을 확인하는 것이 필요하다.

재하된 H형강 휨재의 열응력해석을 이용한 한계온도 산정 (Calculation of Limit Temperature on H-Beam Flexural Member Through the Thermal Stress Analysis under the Lateral Load)

  • 윤성기;이치형;구본훈
    • 한국강구조학회 논문집
    • /
    • 제27권4호
    • /
    • pp.387-397
    • /
    • 2015
  • 국내의 내화성능평가는 대부분 사양적설계 방법인 품질시험을 통해 이뤄지고 있다. 하지만 시험 특성상 많은 비용과 시간을 요구하며 다양한 건축구조에 대한 내화성능평가에는 어려움이 많다. 따라서 본연구에서는 성능적 설계를 위한 연구로 유한요소 구조해석 프로그램인 ABAQUS를 사용해 H형강 휨재를 대상으로 변수에 따른 열응력 해석을 통해 내화성능을 검토하며, 하중비별 한계온도를 제안한다.

ECC 영구거푸집의 내화성능 및 역학적 특성에 관한 실험적 연구 (An Experimental Study on the Fire Resistance and Mechanical Properties of ECC Permanent Form)

  • 김용로;송영찬;오재근;김재환;김욱종;이도범
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2009년도 춘계 학술논문 발표대회 산업계
    • /
    • pp.75-78
    • /
    • 2009
  • It was investigated fire resistance properties and mechanical properties of high strength concrete column using ECC(Engineered Cementitious Composites) permanent form by KS F 2257 Methods of fire resistance test for elements of building construction and compression test for application of precast concrete column method of high rise building in this study. As a test result, it was appeared that ECC permanent form is available as fire resistance method of high strength concrete and new precast concrete construction method for facilitating construction of high rise building.

  • PDF

CFRP로 보강된 철근콘크리트 휨부재의 내화성능 개선을 위한 실험 (Experiment for the Improvement of Fire Resistance Capacity of Reinforced Concrete Flexural Member Strengthened with Carbon Fiber Reinforced Polymer)

  • 임종욱;서수연;송세기
    • 대한건축학회논문집:구조계
    • /
    • 제33권12호
    • /
    • pp.19-27
    • /
    • 2017
  • This paper is a study to improve the fire-resistance capacity of reinforced concrete (RC) members strengthened by fiber-reinforced-polymer (FRP). The fire resistance of the RC members strengthened by FRP was evaluated through high temperature exposure test. In order to improve the fire resistance of the FRP reinforcing method, a fire-proof board was attached to the reinforced FRP surface and then the high temperature exposure test was carried out to evaluate the improvement of the fire resistance performance. It was confirmed that the resistance to high temperature of NSMR could be improved somewhat compared with that of EBR from the experiment that exposed to high temperature under the load corresponding to 40% of nominal strength. When 30 mm thick fire-resistance (FR) board is attached to the FRP surface, the surface of the reinforced FRP does not reach $65^{\circ}C$, which is the glass transition temperature (GTT) of the epoxy until the external temperature reaches $480^{\circ}C$. In particular, when a high performance fire-proof mortar was first applied prior to FR board attachment, the FRP portion did not reach the epoxy glass transition temperature until the external temperature reached $600^{\circ}C$.

비대칭 슬림플로어 합성보의 내화성능 산정에 관한 해석적 방법 연구 (A Study on the Analytical Method for Fire Resistance Calculation of Asymmetric Slimfloor Beam)

  • 박수영;박원섭;김흥열;홍갑표
    • 한국화재소방학회논문지
    • /
    • 제24권2호
    • /
    • pp.31-37
    • /
    • 2010
  • 비대칭 슬림플로어 합성보(Asymmetric Slimfloor Beam, 이하 ASB)는 비대칭 형강의 일부를 콘크리트 슬래브에 삽입한 합성보로서, 유럽에서 개발되었다. 근래 국내에서도 건축물의 층고저감, 물량감소, 내화 성능 증대 등의 목적으로 ASB의 연구가 진행되고 있다. 본 연구에서는 실험을 통하여 ASB의 내화성능을 확인하고, 열전달해석을 통하여 내화성능 시간에서의 모멘트 내력(Moment capacity)을 산정하였다. 그 결과를 바탕으로 방화석고보드와 ASB로 구성된 3시간 내화구조를 선정하고, 내화 성능을 검토하였다.

Evaluation of the Fire Resistance Performance of Interior Anchor Type CFT Columns through Loaded Heating Test

  • Kim, Sunhee;Yom, Kyongsoo;Choi, Sungmo
    • 국제초고층학회논문집
    • /
    • 제2권1호
    • /
    • pp.39-48
    • /
    • 2013
  • The fire resistance performance of generic CFT columns has been verified through various tests and analyses and the columns are widely used for fire resistance designs abroad. In this study, 3 groups of specimens (Non-fire protection, reinforcement with steel fiber and fire resistance paint) are suggested in order to evaluate the fire resistance performance of interior anchor type concrete-filled steel tubular columns having efficient cross-sections through loaded heating tests. Axial deformation-time relationship and in-plane temperatures are compared to evaluate the fire resistance performance of the specimens associated with variables. Suggested from the fact that the interior anchors exposed to fire exert influence on fire resistance performance due to thermal expansion, the reinforcements using steel fiber and fire resistance paint are verified to mitigate contraction and improve fire resistance performance. The result obtained from the tests of interior anchor type concrete-filled tubular columns is expected to be used for effective fire resistance design in association with previously conducted studies.

방화용 실런트 성능 평가 방법 연구 (A study for the test method of fire resistance construction sealant)

  • 안명수;정진영;배기선
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 추계 학술논문 발표대회
    • /
    • pp.179-182
    • /
    • 2013
  • Many kinds of fire-stop sealants have been used for joint sealing, cable penetration part sealing and fireproof structure finishing etc in building sectors which need water-proofing and fire-stop properties. But, fire-stop sealant itself has no specific industry standards in Korea even though there are so many required properties for the application. So, in this study, for the evaluation, we adopted and applied UL standard 94(UL 94) which is commonly used for the fire retardant testing in inflammable materials like plastics and rubbers in electronics industry. In this study, we demonstrated fire resistance properties of each fire-stop sealants which varied with different formulation, thickness and origins available in Korea. Overall, fire stop sealant had better fire resistance performance than normal construction sealant. And the thicker the material, the better the fire resistance performance was. Because there is no national or industry guideline for fire stop sealant itself, each sealant products showed different level of performances under UL94 desigation. Even certain product had very poor fire proof propeties although it claims it can be used for the application.

  • PDF

경골목구조 벽체의 내화성능확보를 위한 질석보드 개발 (Development of Vermiculite Board to Secure the Fire Resistance Performance of Light-Frame Wood Structural Wall)

  • 유석형;정창헌
    • 한국화재소방학회논문지
    • /
    • 제32권1호
    • /
    • pp.40-45
    • /
    • 2018
  • 무기재로서 질석은 친환경적인 특성과 내화, 단열, 흡음 뿐 만 아니라 결로방지, 탈취 및 미관 등이 우수하므로 건축마감재로서 활용될 경우 효용성이 높을 것으로 판단된다. 본 연구에서는 질석을 주원료로 하여 미네랄 루즈울(Mineral Loose Wool) 또는 미네랄 파우더(Mineral Powder)를 혼입한 건축용 마감보드를 개발하고 불연시험과 단열시험을 수행하였다. 시험결과 두 개의 질석보드 모두 불연재로서 성능을 확보하였으며 열전도율 0.086 및 $0.092W/m{\cdot}K$로 나타났다. 또한 개발된 두 개의 질석보드를 경골목구조 내화벽체 표준상세(KS F 1611-1)의 마감재로 적용하여 내화시험을 수행하였다. 내화시험결과 VB-L 시험체가 VB-P시험체 보다 내화성능이 다소 높게 나타났으며 두 개의 질석보드 모두 두께 30 mm로도 내화성능 2시간 확보가 충분한 것으로 나타났다.