• 제목/요약/키워드: Fire Reduction Measures

검색결과 26건 처리시간 0.015초

공장건물의 화재리스크 경감방안에 관한 연구 (A Study on Factory Building Fire Risk Reduction Management)

  • 정의수;강경식
    • 대한안전경영과학회지
    • /
    • 제10권3호
    • /
    • pp.43-53
    • /
    • 2008
  • This study is carried out for the fire safety of the factory building, the fire risk reduction measure in compliance with an example approached in fire risk reduction systematically, contribute to reduce the fire risk. The analytical fire risk process of discovering, identifying, estimating and evaluating risk and control measure as risk reduction measures are core concept, applies loss prevention with loss control techniques. The painting process in the workplace where the fire hazard and death accident accompanies coexists. Loss prevention problem of creation prevention of dangerous atmosphere at workplace is health and human services problem of normal circumstances, must be inspected with problem of combustible gases at the time of fire explosion. Static electricity measure accomplished the risk control process thoroughly as the fire risk reduction process model with the ignition sources measure which is presented. Fire risk from within organizing will be able to classify with each field by detailedly but risk treatment process will be able to apply basically all the same concept. Consequently about risk management example from before, this study is proposed risk management techniques that standardized rightly in the actual condition of organization with one plan, with discovery of fire risk, the feedback process in compliance with a fire risk reduction and the review which control the result is joint responsibility of engineer, technical expert and manager as part of safety management to practice with the fact must be supervised.

통합플랫폼관리체제에서 퍼지논리를 이용한 화재진압통제 지능시스템의설게 및 구현 (A Design and Implementation of the Intelligent System for the Fire Fighting Control using Fuzzy Logic in Integrated Platform Management System)

  • 현우석;김용기
    • 한국정보처리학회논문지
    • /
    • 제7권7호
    • /
    • pp.2095-2107
    • /
    • 2000
  • In maned ship, crews may have risks as they manage damage control system in IPMS in damage situations such as fire in a ship. So the application of unmaned autonomous systms can reduce the number of boarding crews and attribute to safe marine transportation. The paper suggests an intelligent system of the fire fighting control using fuzzy logic in Integrated Platform Management System which can take measures against fire situation of a ship excluding unnecessary warnings with undamaged situations. The system here detected the fire more accurately and adopted more appropriate measures according to ship status compared with conventional systems. Of all, a reduction of false detection of fires was noted.

  • PDF

건축물 전동셔터 추락 리스크 분석 및 저감 방안 (Analysis on the Falling Risk of Building Electric Shutter and Reduction Measures)

  • 정영민;방홍순;김옥규
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 봄 학술논문 발표대회
    • /
    • pp.295-296
    • /
    • 2021
  • With the recent diversification and complication of buildings, the functions of building are also developing. As much as the development of buildings, the machine or equipment used for them is also developing. Thus, all sorts of domestic/foreign industrial facilities and fire stations in the whole nation are using the electric shutter that could meet the insulation just like the exterior wall of general buildings, for bringing-in/storage and crime prevention/fire prevention. Currently, various types of electric shutters are used. Such wrong operation and poor management are causing many panel-falling accidents. This study researched the reduction of electric shutter panel-falling risk by reviewing the domestic/foreign laws and standards, and researching the new safety equipment. First, the causes for falling and accident types were drawn by analyzing the cases of electric shutter accidents. After that, a checklist as the measures for reducing the falling of electric shutter in building was suggested by analyzing the items for the inspection of electric shutter.

  • PDF

소방안전교부세의 운영 및 개선방안에 관한 연구 (Study on the Management and Improvement Methods of Fire Safety Shared Tax)

  • 장중돈;이종호
    • 한국화재소방학회논문지
    • /
    • 제32권6호
    • /
    • pp.117-125
    • /
    • 2018
  • 본 연구는 소방재원인 소방안전교부세가 교부된 후 사업 선정 및 운영 등의 인식에 관한 문제점을 도출하고 그에 대한 개선방안을 제시하는 데 있다. 이를 위해서 소방안전교부세의 세부 사업운영 인식, 사업집행 만족도, 재정 운영방안에 관련한 내용을 소방공무원을 대상으로 설문조사한 결과, 소방안전교부세 운영에 있어 소방공무원들은 소방안전교부세의 세부사업분야, 투자내용 등에 관한 관심이 소홀한 것으로 나타났다. 교부세 집행 후의 만족도에서는 소방장비에 대한 노후율 감소 및 보급률 향상은 소방장(M = 3.70)과 16년 이상(M = 3.64)의 재직기간에서 높은 것으로 나타났다. 재정의 개선방안에 있어서 국고보조금의 감소가 부적절하다는 의견이 많았다. 제한적으로 운영되고 있는 소방안전교부세 사업의 다변화 및 개발과 함께 국고보조금 사업이 안전분야 사업과 대부분 중복되고 있어 부족한 소방재원을 안정적으로 확보하기 위해 교부세 전액을 소방분야에 투자될 수 있도록 법제도적 개선이 필요하다.

How to Reduce Fire Fatalities in Residential Occupancies on the Way to a Rapidly Aging Society?

  • Sekizawa, Ai
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2006년도 춘계학술논문발표회 논문집
    • /
    • pp.29-40
    • /
    • 2006
  • Everybody may be vulnerable to fires depending on the time, place, and circumstances. Fire statistics show that the occurrence of fire death depends not only on the severity of a fire itself, but also largely on the conditions of occupants such as physical functions, the environment around occupants, and the type of facility where are fire occurs. The review of fire safety from the viewpoint of vulnerable populations does not simply mean additional special attention and care only to high risk groups, but instead it means significant review of fire safety design and systems for all people from a more universal standpoint. Therefore, in order to examine the strategies of a fire death-reduction program, safety measures suitable for the relevant high-risk groups considering the type of vulnerable person, the type of fire, and the type of building in residential occupancies. Solutions will require strenuous multilateral effort and flexibility.

  • PDF

Development and Application of CFT without Fire Protection using High Performance Steel and Concrete

  • Hong, Seok-Beom;Kim, Woo-Jae;Park, Hee-Gon
    • 한국건축시공학회지
    • /
    • 제13권3호
    • /
    • pp.272-281
    • /
    • 2013
  • Concrete filled tube (CFT) columns, which consist of a steel tube filled with concrete, combine the benefits of the two materials. The steel tube provides a confining pressure to the concrete, while the local buckling of steel plate can be prevented by the concrete core. CFT columns also have a high fire resistance due to the heat storage effect of concrete under fire. For this reason, it is possible to develop CFT columns without fire protection measures. CFT columns without fire protection have many advantages, including quality control, cost reduction, better space efficiency and a shorter construction period. Due to these advantages, studies on the development of CFT columns without fire protection measures have been performed. However, CFT columns lose their bearing capacity under fire because the steel tube is exposed to the outside. As a result, the structure is collapsed, causing significant damage. In this research, we made a CFT column using high strength concrete (100 MPa) and high strength steel (800 MPa). We use steel fiber and nylon fiber with concrete to provide fire resistance. We perform the fresh concrete experiment and investigate the fire resistance of the CFT column (${\Box}400{\times}400{\times}15{\times}3000mm$) under loading. To investigate the effect of steel fiber on increasing fire resistance, we compare the fire resistance time according to the steel fiber. Through the test, it was found that the CFT specimen with steel fiber had better fire resistance performance than other cases.

제천스포츠센터의 수직 화재확산 해석을 위한 화재시뮬레이션 분석에 관한 연구 (A Study on the Fire Simulation for Vertical Fire Diffusion Analysis of Jecheon Sports Center)

  • 최윤주;김윤성;이병흔;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 봄 학술논문 발표대회
    • /
    • pp.79-80
    • /
    • 2022
  • In December 2017, a fire at the Jecheon Sports Center caused 29 deaths and 40 injuries, and about 2 billion won in property damage. It is a facility used by unspecified people as a publicly used establishment with a piloti structure. The damage was expanded due to the ignition of combustible exterior materials, Lack of fire protection in horizontal and vertical penetrations. Although legislation has improved since the fire, it is not retroactively applied, increasing the risk of fire in existing buildings. Accordingly, it is necessary to examine the case of the Jecheon Sports Center fire and draw out the problems. In this study, the fire simulation results and the Jecheon Sports Center fire are comparatively analyzed and used as basic data for fire reduction measures in publicly used establishment. As a result of the fire simulation drive, in the case of the second floor, the room temperature exceeded the human life safety standard of 60 ℃ after about 700 seconds had passed. In the case of three floor, it is predicted that the indoor temperature will exceed about 350 ℃. and temporary complexation will occur in the indoor combustibles.

  • PDF

Copper-Based Compounds against Erwinia amylovora: Response Parameter Analysis and Suppression of Fire Blight in Apple

  • Duck Kyu, Ryu;Mahesh, Adhikari;Dong Hyuk, Choi;Kyung Jin, Jun;Do Hyoung, Kim;Chae Ryeong, Kim;Min Kyu, Kang;Duck Hwan, Park
    • The Plant Pathology Journal
    • /
    • 제39권1호
    • /
    • pp.52-61
    • /
    • 2023
  • Fire blight, caused by Erwinia amylovora, is one of the major bacterial disease of apple and pear, causing enormous economic losses worldwide. Several control measures against E. amylovora have been reported till date, however, none of them have proved to be effective significantly against the pathogen. In this study, mechanisms of the copper-based control agents (CBCAs): copper oxychloride (COCHL), copper oxide (COX), copper hydroxide (CHY), copper sulfate basic (CSB), and tribasic copper sulfate (TCS) and their disease severity reduction efficacy against E. amylovora were analyzed. Bis-1,3-dibutylbarbituric acid trimethine oxonol, carboxyl fluorescein diacetate succinimidyl ester, and 5-cyano-2,3-ditolyl tetrazolium chloride staining were used to check the damage of membrane potential, cytoplasmic pHin, and respiration of CBCAs-treated E. amylovora, respectively. High disturbance in the membrane potential of E. amylovora was found under COX and COCHL treatments. Similarly, higher significant changes in the inner cytoplasmic pHin were observed under COX, COCHL, and TCS treatment. CHY and COCHL-treated E. amylovora showed a significant reduction in respiration. In vitro bioassay results revealed that CHY, CSB, and TCS at 2,000 ppm reduced the severity of fire blight both in pre- and post-treatment of CBCAs in immature apple fruits and seedlings. Overall, the most effective CBCAs against E. amylovora could be CHY at 2,000 ppm as its showed inhibition mechanisms and disease severity reduction.

계면활성제 첨가에 따른 함수율에 관한 실험적 연구 (Experimental Study on Moisture Content According to Addition of Surfactants)

  • 김남균;이동호
    • 한국화재소방학회논문지
    • /
    • 제29권2호
    • /
    • pp.79-83
    • /
    • 2015
  • 화재사고는 그 충격과 영향이 업무중단 및 기업의 존폐를 좌우 할 수 있는 대표적인 재난 유형이다. 따라서 사전 예방, 대비는 물론 재난 발생 시 신속한 초기대응이 매우 중요하다. 현재 운용되고 있는 저탄장 및 합판 가공 산업 분야 등에서는 다공성 가연물의 저장이 불가피하다. 다공성 가연물 저장 공간의 화재는 그 특성상 발화시점의 파악 및 초기진압이 어려우며, 초동 대처에 실패할 경우 표면화재에서 심부화재로 이어져 2차 화재피해가 발생할 가능성이 높다. 또한 심부화재는 다량의 독성가스발생과 재발화로 인해 인적 물적 피해를 야기할 수 있으므로 다공성 가연물을 취급하는 저장공간을 중심으로 피해경감 대책이 요구된다. 본 연구는 침윤소화약제 사용 시 다공성 물질의 심부화재 소화 효율 증대에 관한 기초 연구로써, 계면활성제의 농도에 따른 침투성능의 향상에 관한 연구를 수행하였다. 실험에 사용된 다공성 물질은 국내 사용 목재의 75%를 점유하고 있는 뉴질랜드산 소나무의 원목 목분을 사용하였다. 소화용수는 침윤소화약제에 사용되고 있는 Butyl Di Glycol (BDG)을 선택하여 농도에 따른 표면장력별 표준시료를 제작하여 실험을 수행하였다. 실험은 NFPA 18의 Deep-Seated Fire Test를 기초로 수행하였으며, 살수량과 다공성 물질 내부로의 침투량, 다공성 물질 외부로의 배출량 측정 실험을 실시하였다. 실험결과 계면활성제 농도에 따른 표면장력이 감소함에 따라 거시적 침투속도는 감소하나 다공성 물질 내부로의 침투량은 증대되는 특성을 확인하였다.

현장 소방활동 중 소방공무원 화상사고 사례 분석 연구 (Case Studies of Firefighter Burns Safety Accident during Fire-fighting Activities)

  • 최신웅;이소연
    • 한국안전학회지
    • /
    • 제37권6호
    • /
    • pp.136-147
    • /
    • 2022
  • The purpose of this study is to analyze four cases of firefighter burns in various fire scenes and to find prevention measures to decrease firefighter injuries. Among the analysis reports prepared by the National Fire Research Institute of Korea from 2016 to 2020, four burn-related accidents are summarized and the main causes are conveyed. The four accidents include second-degree burns from using extinguishers during containment of fires; nine firefighters burned due to re-ignition in the LPG car repair shop; two firefighters injured with third-degree burns from using fire extinguishers during life-saving events in residential housing; and injuries from the radiant heat of the tank BLEVE near the factory fire. These cases are comprehensively investigated in their respective scenes and analyzed based on the fire site investigation reports from the fire department and related theoretical explanations of risk for each accident scene. In the third case study, some experimental research is conducted to evaluate the risk involved with the use of safety gloves. This is evaluated by reviewing Fire Tactics and Standard Operational Procedures (SOP) to determine improvements and recommendations for an efficient firefighting response. Results show that the main causes of burn accidents are the insufficient use of personal protective equipment (PPE), such as safety gloves, and the failure to follow firefighting tactics or SOPs. Through the accident investigation and assessment, it is concluded that to reduce the frequency of burn accidents, the performance of firefighting equipment, SOPs, protection tactics, and safety policy systems require improvement.