• Title/Summary/Keyword: Fire Protection System

Search Result 566, Processing Time 0.032 seconds

Development and Feasible Study of Train to Pedestrian Protection Airbag (철도차량 접촉사고자 보호 에어백 개발연구)

  • Yoo, Wan-Dong;Ham, Joung-Sik;Cho, Kyue-Sang
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.20 no.4
    • /
    • pp.82-91
    • /
    • 2012
  • This paper deals with the development and feasible study of the train to pedestrian protection airbag. The concept of the airbag system is to protect the pedestrian like as workers on railroad. The airbag system includes cushions, gas generators, a housing, sliding fixture, anti-bouncing airbag, and a leg protection bumper. Those things were designed and fabricated. The performance of the airbag system was evaluated in the sense of the static deployment test, drop test, dynamic motion test and field(train level) test. The deployment logic, TTF(Time to fire), and the inner pressure of the cushion were also investigated for the airbag.

Study of an Efficient Method for Securing Evidence During the Fire Investigation (화재조사 시 증거물의 효율적인 확보 방안에 관한 연구)

  • Ye, Su-Jo;Choi, Don-Mook
    • Fire Science and Engineering
    • /
    • v.30 no.6
    • /
    • pp.43-47
    • /
    • 2016
  • The recent changes in the judicial system in South Korea, including the stronger trial-centrism and legal market opening, have made fire investigations seek more scientific evidence and structure. The collection of physical evidence is very important to prove the substantial truth of a fire at the court. Without the appropriate physical proof, the credibility of a fire investigation is lost as evidence in a court. Therefore, the fire investigation team needs to carefully handle the fire site and fire initiation evidence because evidence of a fire incident can be destroyed easily by chemical and physical damage. In addition, the fire investigation team also needs to carefully record the collections of any evidence including pictures and their analysis. This study proposed the needs of the procedure manual and guidelines that can provide a step-by-step process of fire investigations in South Korea. This study also helps fire investigation agencies to secure fire-scene evidence to distinctly investigate the facts of fire. The guidelines and manual can eventually improve the ways for the fire investigation processes in South Korea.

An Improvement Plan on Fire Safety Management of Public Institutions: Focusing on the Case of Elementary and Secondary Schools (공공기관 소방안전관리 실태조사를 통한 개선방안에 관한 연구 : 초·중등학교를 중심으로)

  • Han, Sang-Pil
    • Fire Science and Engineering
    • /
    • v.34 no.3
    • /
    • pp.85-90
    • /
    • 2020
  • The aim of this study is to identify ways to improve fire safety management of elementary and junior high schools, which can prevent potentially dangerous situations and establish a rapid response system for fire-related emergencies by analyzing existing fire safety management public institutions. We investigated the expertise, prevention ability, preparation ability, and operation form of fire safety managers working in elementary and secondary schools in Kangwon Province. A questionnaire composed of 26 items was completed by 238 fire safety managers. Results shows that the perception of fire safety management is considerably high, while the ability of the fire safety manager to prepare for and cope with an accident still needs improvement.

Measurement of Flash Point for Binary Mixtures of Methanol, Ethanol, 1-propanol and Toluene (Methanol, Ethanol, 1-propanol 그리고 Toluene 이성분 혼합계에 대한 인화점 측정)

  • Hwang, In Chan;Kim, Seon Woo;In, Se Jin
    • Fire Science and Engineering
    • /
    • v.32 no.1
    • /
    • pp.1-6
    • /
    • 2018
  • The flash point is one of the most important parameters used to characterize the ignition and explosion hazards of liquids. Flash points were measured for several binary systems containing toluene, including {methanol+toluene}, {ethanol+toluene}, and {1-propanol+toluene}. Experiments were performed according to the standard test method using a SETA closed cup flash point tester. The measured flash points were compared with the predicted values calculated using the following $G^E$ models: Wilson, NRTL, and UNIQUAC. The average absolute deviation between the predicted and measured lower flash point was less than 1.69 K.

A Study on Egress Algorithm for High-rise Buildings Using Egress Simulation (피난시뮬레이션을 이용한 초고층건물의 피난 알고리즘 연구)

  • Kim, Won Kook;Seo, Dong Hyun
    • Fire Science and Engineering
    • /
    • v.32 no.1
    • /
    • pp.33-39
    • /
    • 2018
  • When the fire in the high-rise building was not extinguished in its early stage and propagated over its origin, safe egress becomes one of the most important factor to minimize the casualties. Recently fire protection for high-rise building has been reinforced after experiencing the series of disastrous fires. But, we still find many high-rise buildings do not comply with those reinforcement. And also there is a possibility of failure of reinforced fire protection system. Under these situation safe egress guide would be the final layer of protection. In this study existing egress methods were identified and evaluated. According the result of study, priority in egress should be given to the tenants on the floor of fire origin and floors exposed to the risk of fire. Then, the rest of the tenants can be evacuated simultaneously. Floors exposed in fire risk shall be determined by fire tests and/or fire simulations. But, the result of fire monitoring shall override preliminary estimations. Egress time for each algorithm was estimated by egress simulation and the result was compared. There was a little difference in egress time between total egress and phased egress, and a big difference between using stairs only and using elevators and stairs together. to a constant thickness between layers constituting a firefighter's protective clothing should be considered in the future.

Development of Multipoint Simultaneous Full-duplex Team Communication Module for SCBA (SCBA 면체용 다자간 동시 양방향 팀 통신모듈 개발)

  • Kim, Si-Kuk;Choi, Su-Gil;Lim, Woo-Sub;Han, Yong-Taek
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.165-172
    • /
    • 2019
  • This study presents the design and manufacture of a self-contained breathing apparatus SCBA wireless communication module with a multipoint simultaneous full-duplex communication system to enable communication between team members wearing the SCBA system. It is necessary for fire-fighters to wear the SCBA system during extinguishing and rescue work at the fire site. Evaluation of the team communication module confirmed the feasibility of communication over more than 500 m in the test condition based on the line of sight. By implementing the Ad-hoc function, it was confirmed that the communication distance could be extended to 128 m by automatic routing up to 3 hoc. The vertical distance inside the building for successful communication was up to the 5th floor in the open staircase and up to the 3rd floor in the partitioned staircase. Furthermore, the performance testing of the communication module assuming a fire situation, confirmed that five team members correctly recognized the standard abbreviation of fire and wireless communication without a separate PTT key operation. In addition, the flame resistance was verified by exposing the module to a flame at 950 ± 50 ℃ for 5 s and then immediately extinguishing the flame.

A Study on Development of New 3-Phase Open-Phase Protector used in Distribution Panel (새로운 분전반용 3상 결상보호기 개발에 관한 연구)

  • Kwak, D.K.;Kim, J.H.;Park, Y.J.;Jung, D.Y.;Kim, D.K.;Kim, P.R.
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.546-547
    • /
    • 2012
  • In the three-phase power system using the three-phase load, when any one-phase is open-phase, the unbalanced current flows and the single-phase power supplied by power supply produces over-current. As a result, the enormous damage and electrical fire can be given to the power system. In order to improve these problems, this paper is proposed a new control circuit topology for open-phase protection using semiconductor devices. Therefore, the proposed open-phase protection device (OPPD) enhances the sensing speed and precision, and has the advantage of simple fitting in the three-phase distribution panel in the field, as it manufactures into small size and light weight. As a result, the proposed OPPD minimizes the electrical fire from open-phase, and contributes for the stable driving of the power system.

  • PDF

Study on the Improvement Operation of the Incident Command System (긴급구조통제단 운영 개선방안)

  • Chae, Jin;Bae, Young-Hwan
    • Fire Science and Engineering
    • /
    • v.33 no.3
    • /
    • pp.128-137
    • /
    • 2019
  • The aim of this study was to suggest ways to improve the operation of the Incident Command System for an effective disaster response in the event of a major disaster. As a result of the study, at the 5% significance level, which affects the perception of the operation, the significant variables that influence the operation of the Incidence Command System were found to be securing the operating budget, cooperation of the related agencies, disaster resource support, and expert training. The relative influence of the variables on the operation of the Incident Command System was found to be in the order of expert training, cooperation of related organizations, disaster resource support, and securing of the operating budget.

A study on present status and improvement of protection relay system in subway station for stable power supply (지하철 역사의 안정적 전원공급을 위한 보호시스템 검토)

  • Na, Jong-Woo;Jo, Won-Kang;Park, Dong-Seon;Yoo, Yeon-Seong;Moon, Hwa-Soo
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.433-444
    • /
    • 2008
  • Nowadays, subway station has provided not only transportation but living spaces for everyday activities. Therefore, a variety of facilities have been installed for a safety of citizens such as fire-fighting equipment, platform screen doors and giving high level of benefits such as air-conditioning and heating equipment, escalators, lighting apparatus. In order to operate these facilities appropriately, it is needless to say that electric power supply must be reliable. Many protection relays have been installed to protect electric apparatus and power system, nevertheless it..s study has been insufficient in the concrete. From this paper, through analyzing of protection relay system of electric room operated in line 2 of Seoul metro, we can help to improve stable power supply system of subway station.

  • PDF

Method for Preventing Asphyxiation Accidents by a CO2 Extinguishing System on a Ship (선박 내 CO2 소화설비에 의한 질식사고 방지 기법)

  • Ha, Yeon-Chul;Seo, Jung-Kwan;Hwang, Jun-Ho;Im, Kichang;Ryu, Sang-Hoon
    • Fire Science and Engineering
    • /
    • v.29 no.6
    • /
    • pp.57-64
    • /
    • 2015
  • Carbon dioxide extinguishing systems are broadly used for onshore and offshore fire accidents because of excellent performance and low cost. However, there is risk with carbon dioxide systems, which have caused many injuries and deaths by suffocation associated with industrial and marine fire protection applications. In this study, a numerical analysis was performed to predict the fire suppression characteristics of a carbon dioxide system in the compressor room of ships. A double protection safety system is suggested to prevent suffocation accidents from carbon dioxide extinguishing systems. Four scenarios were selected to study the variation of the heat release rate, maximum temperature, a $CO_2$ and $O_2$ mole fraction, and fire suppression characteristics with the carbon dioxide system. The importance of proper design is suggested for a ventilation system in the compressor room of ships.