• Title/Summary/Keyword: Fire Prediction

Search Result 446, Processing Time 0.024 seconds

Investigation on the Field Application of the Flammable Limit of Vaporized Gasoline (휘발유 유증기 폭발범위의 현장 적용성에 관한 연구)

  • Kang, Jung Ki;You, Woo Jun;Choi, Don-Mook
    • Fire Science and Engineering
    • /
    • v.29 no.4
    • /
    • pp.73-80
    • /
    • 2015
  • In this study, the conditions of explosion range of gasoline, which is used as combustion improver, are experimentally analyzed. Two types of compartment, which is the small scale ($0.5m{\times}0.5m{\times}1.0m$) and the middle scale ($0.5m{\times}0.5m{\times}1.0m$), are mocked-up and the auto-control systems are installed in order to measure the vaporized gasoline and the moment of pressure, ignition time and maximum pressure. In case the maximum flammable limit of gasoline is up to 22.4 Vol% not the generalized range of 1.4~7.6 Vol% when nichrome igniter of $700^{\circ}C$ is used. These results can be appled to the analytical prediction of fire identification in the field of explosion.

Numerical Study on Skin Burn Injury due to Flash Flame Exposure (돌발화염으로 인한 화상예측에 관한 수치해석적 연구)

  • Lee, Jun-Kyoung;Bang, Chang-Hoon
    • Fire Science and Engineering
    • /
    • v.26 no.5
    • /
    • pp.13-20
    • /
    • 2012
  • Many fire-fighters suffer from the burn injuries, and the severe burns are the most catastrophic injury a person can survive, resulting in pain, emotional stress, and tremendous economic costs. It is important to understand the physiology of burns for prevention from skin burns and a successful treatment of a burn patient. But a few researches have been presented because the complex physical phenomena of our inside body like non-linearity characteristics of human skin make them difficult. Thus in this study, thermal analyses of biological tissues exposed to a flash fire causing severe tissue damage were studied by using a finite difference method based on the Pennes bio-heat equation. The several previous models for skin thermo-physical properties were summarized, and the calculated values with those models of tissue injury were compared with the results obtained by the previous experiment for low heat flux conditions. The skin models with good agreement could be found. Also, the skin burn injury prediction results with the best model for high heat flux conditions by flash flame were suggested.

A Study on Facility Criteria of Small Petrol Stations based on Quantitative Risk Assessment (정량적 위험성 평가에 기반한 간이 주유취급소 시설기준에 대한 연구)

  • Park, Wooin;Ku, Jae-Hyun;Song, Yong-Sun
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.3
    • /
    • pp.44-52
    • /
    • 2014
  • Small petrol stations have great potential for a wide distribution in metropolitan area in which the land value possesses primary installation cost of the facility. The objective of the present study is to propose appropriate facility regulations of small petrol stations in Korea that can be popularly installed in the future in terms of securing safety in addition to serviceability. The hazard analysis and damage prediction from the possible fire and explosion accidents were performed using a software, PHAST v.6.5. As essential components of the facility regulations proposed in this study, the regulations about the refueling lot, maximum capacity of underground tank, location of fixed refueling facilities, height of firewall for small petrol stations were subsequently compared with those for regular-sized petrol stations.

Prediction of Heat of Combustion of Polymer Materials Using Combustion Characteristics (연소 특성치를 이용한 고분자재료의 연소열 예측)

  • Ha Dong-Myeong;Lee Su-Kyung
    • Fire Science and Engineering
    • /
    • v.19 no.3 s.59
    • /
    • pp.70-75
    • /
    • 2005
  • The heat of combustion of polymer materials is an important fire characteristics, which can be used with other fire parameter to predict the potential fire hazard in the polymer handling process. The aim of this study is to predict the heat of combustion for polymers which used in the building interior materials. By using the literature data and multiple regression, the new equation for predicting the heat of combustion of polymers is proposed. The A.A.p.E.(average absolute percent error) and the A.A.D.(average absolute deviation) of the reported and the calculated heat of combustion by means of the oxygen consumption calorimeter and the stoichiometric coefficient were 4.46 and 1.09, and the correlation coefficient was 0.972. The values calculated by the proposed equations were in good agreement with the literature data. Therefore, it is expected that this proposed equations will support the use of the research for other polymer materials.

Evaluation of Fire-induced Damage for Shield Tunnel Linings Subjected to High Temperatures (고온에 노출된 쉴드터널 라이닝의 손상평가)

  • Lee, Chang Soo;Kim, Yong Hyok;Kim, Young Ook
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.4
    • /
    • pp.1-8
    • /
    • 2012
  • The aim of this study is to evaluate fire-induced damage for shield tunnel linings. Full-scale fire test was conducted to evaluate fire-induced damage. Residual compressive strength was measured on the core samples of shield tunnel lining subjected to high temperatures. Heating temperature was predicted by XRD and TG analysis. As a result, Strength degradation of concrete with temperatures can be evaluated by residual compressive strength of core samples. In addition, residual compressive strength can be estimated by previous studies if heating temperature is exactly predicted. It is possible that heating temperature is predicted by XRD and TG analysis at $450^{\circ}C$. For more accurate prediction of heating temperature it should be performed both instrumental analysis and analytical methods with temperatures ranging from $400{\sim}600^{\circ}C$.

A novel prediction model for post-fire elastic modulus of circular recycled aggregate concrete-filled steel tubular stub columns

  • Memarzadeh, Armin;Shahmansouri, Amir Ali;Poologanathan, Keerthan
    • Steel and Composite Structures
    • /
    • v.44 no.3
    • /
    • pp.309-324
    • /
    • 2022
  • The post-fire elastic stiffness and performance of concrete-filled steel tube (CFST) columns containing recycled aggregate concrete (RAC) has rarely been addressed, particularly in terms of material properties. This study was conducted with the aim of assessing the modulus of elasticity of recycled aggregate concrete-filled steel tube (RACFST) stub columns following thermal loading. The test data were employed to model and assess the elastic modulus of circular RACFST stub columns subjected to axial loading after exposure to elevated temperatures. The length/diameter ratio of the specimens was less than three to prevent the sensitivity of overall buckling for the stub columns. The gene expression programming (GEP) method was employed for the model development. The GEP model was derived based on a comprehensive experimental database of heated and non-heated RACFST stub columns that have been properly gathered from the open literature. In this study, by using specifications of 149 specimens, the variables were the steel section ratio, applied temperature, yielding strength of steel, compressive strength of plain concrete, and elastic modulus of steel tube and concrete core (RAC). Moreover, parametric and sensitivity analyses were also performed to determine the contribution of different effective parameters to the post-fire elastic modulus. Additionally, comparisons and verification of the effectiveness of the proposed model were made between the values obtained from the GEP model and the formulas proposed by different researchers. Through the analyses and comparisons of the developed model against formulas available in the literature, the acceptable accuracy of the model for predicting the post-fire modulus of elasticity of circular RACFST stub columns was seen.

The Prediction of Lower Explosion Limit of n-Hexadecane (n-Hexadecane의 폭발하한계 예측)

  • Ha, Dong-Myeong;Park, Sang-Hun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.163-163
    • /
    • 2013
  • 최근의 수많은 산업 현장에서 취급하고 있는 각종 화학물질은 잠재적 위험성이 크므로 보관, 수송 및 취급할 때 특별한 주의가 필요하다. 공정 설계 시 정확하지 않은 폭발한계를 사용함으로서 사고가 유발되는 경우가 많다. 따라서 사업장에서 사용되고 있는 화학물질의 화재 및 폭발 특성치인 인화점, 폭발한계 등을 정확히 파악하는 것은 중요하다. 인화점은 하부인화점과 상부인화점으로 나누고 있고 있으며, 인화점은 가연성 액체의 화재 위험성을 나타내는 지표로써, 가연성액체의 액면 가까이서 인화할 때 필요한 증기를 발산하는 액체의 최저온도 또는 점화원 존재시 인화가 일어날 수 있는 최저온도, 그리고 가연성증기의 포화증기압이 공기와 혼합기체의 폭발한계 하한농도와 같게 되는 온도로 정의한다. 폭발한계는 발화원이 존재할 때 가연성가스와 공기가 혼합하여 일정 농도범위 내에서만 연소가 이루어지는 혼합범위를 말한다. 본 연구에서는 실제 공정에서 사용되고 있는 n-Hexadecane의 인화점을 측정하여 이를 기존 문헌값과 비교 하였고, 측정된 인화점을 이용하여 폭발한계를 예측하였다. 예측된 폭발한계를 여러 문헌에 제시된 자료과 비교하여 공정안전에 타당한 자료를 제시하였다. 본 연구는 n-Hexadecane을 취급하는 공정에서 안전 확보의 중요한 지침 마련과 MSDS D/B의 최신화에 유용한 정보를 제공하는데 목적이 있다.

  • PDF

Study on Prediction System Construction of Fire.Explosion Accident by NG & LPG among Domestic Gas Accidents (국내 가스 사고사례 중 NG 및 LPG의 가스 화재.폭발사고 예측시스템 구축에 관한 연구)

  • Ko Jae-Sun;Kim Hyo
    • Journal of the Korean Institute of Gas
    • /
    • v.10 no.1 s.30
    • /
    • pp.48-55
    • /
    • 2006
  • In order to establish the comprehensively, quantitatively predictable program to the fire and explosion accidents in the urban gas system, and to set up domestic criteria of societal risk, the collected urban gas accident data have been deeply analyzed. The Poisson probability distribution functions with t=5 for the database of the gas accidents in recent 11 year shows that 'careless work-explosion-pipeline' item has the lowest frequency, whereas 'joint loosening & erosion-release-pipeline' item has the highest frequency. And thus the proper counteractions must be carried out. The further works requires setting up successive database on the fire and explosion accidents systematically to obtain reliable analyses.

  • PDF

The Measurement and Prediction of Maximum Flash Point Behavior for Binary Solution (이성분계 용액의 최대인화점 현상의 측정과 예측)

  • Ha, Dong-Myeong;Lee, Sungjin
    • Fire Science and Engineering
    • /
    • v.27 no.5
    • /
    • pp.70-74
    • /
    • 2013
  • The flash point is one of the most important physical properties to charaterize fire and explosion hazard of liquid solutions. The maximum flash point of liquid mixture is larger than those of the individual components. In this study, the flash points of 2-pentanol+acetic acid system were measured by Seta flash closed cup tester. This system exhibited the maximum flash point behavior. The flash points were estimated by the Raoult's law and the optimization methods using the van Laar and Wilson equations. The calculated values by optimization methods were found to be better than those based on the Raoult's law.

Prediction of Explosion Limits of Organic Acids Using Combustion Chemical Stoichiometric Coefficients and Heats of Combustion (연소열 및 화학양론계수를 이용한 유기산류의 폭발한계의 예측)

  • Ha, Dong-Myeong
    • Fire Science and Engineering
    • /
    • v.27 no.3
    • /
    • pp.47-51
    • /
    • 2013
  • The explosion limit is one of the major combustion properties used to determine the fire and explosion hazards of the flammable substances. The explosion limit of organic acids have been shown to be correlated the heat of combustion and the chemical stoichiometric coefficients. In this study, the lower explosion and upper explosion limits of organic acids were predicted by using the heat of combustion and chemical stoichiometric coefficients. The values calculated by the proposed equations agreed with literature data within a few percent. From the given results, using the proposed methodology, it is possible to predict the explosion limits of the other organic acids.