• 제목/요약/키워드: Fire Power

검색결과 869건 처리시간 0.025초

모발건조기의 전기화재 위험요소에 따른 화재 감정기법 연구 (Study of Fire Appraisal Method According to Electrical Fire Hazards of Hair Dryer)

  • 문현욱;이기연;김동우;길형준;김향곤
    • 조명전기설비학회논문지
    • /
    • 제25권12호
    • /
    • pp.113-118
    • /
    • 2011
  • In this study, investigation and appraisal method for the scene of a fire according to electrical fire hazards of hair dryer which is usually used at living space are presented. Hair dryer is briefly composed of heating part, wind part and control part. Electrical fire hazards of hair dryer are insulation destruction of power cord, ignition by overheat of heating coil, scattering spark on inside dust, overheat of motor by fan shackle, ignition by carelessness of user, and so on. Fire cause by hair dryer can be perceived through investigation about half-disconnection of power cord, contact badness of power plug, verification of heating coil, fan and switch. These results are expected to be utilized effectively in a countermeasure to prevent an electrical fire by hair dryer.

FDS 이용한 주제어실 화재시 케이블 기능상실시간 평가 (Cable Functional Failure Time Evaluation for a Main Control Room Fire using Fire Dynamic Simulator)

  • 임혁순;김인환;김명수
    • 한국화재소방학회논문지
    • /
    • 제30권3호
    • /
    • pp.79-85
    • /
    • 2016
  • 원자력발전소의 방화지역에서 전기적인 단락, 지락, 전기회로 개방 등의 전기 문제로 화재가 발생할 수 있다. 전기 화재가 발생할 경우 안전계통 및 관련기기의 안전정지 기능이 상실된다. 이러한 사고를 예방하기 위하여 안전계통은 다중성, 독립성으로 설계되어 있다. 그러나 케이블 화재시 운전원은 오동작, 잘못된 지시 및 계측으로 발전소 상황을 잘 못 판단하여 적절한 조치를 하지 못할 수 있다. 따라서 주제어실 화재시 케이블 기능상실온도에서 최소 운전원 조치 요구시간인 5분은 매우 중요하다. 본 논문에서 주제어실 화재시 케이블의 기능상실온도 시간을 분석하여 운전원 조치시간이 충분한지 평가하여 주제어실 화재에 대한 안전성을 확인하였다.

소방전원계통의 전원용량과 간선의 전압강하에 대한 문제점 분석 (Problem Analysis of Power Capacity and Main Line Voltage Drop of Electric Power System for Fire Protection)

  • 최승규;손봉세
    • 한국화재소방학회논문지
    • /
    • 제29권3호
    • /
    • pp.53-58
    • /
    • 2015
  • 최근 소방대상물의 대형화는 소방전기계통의 용량과 간선길이를 급격하게 증가시키고 있어, 과거의 소규모 소방대상물에서는 문제가 되지 않았던, 소방전원의 용량부족과 간선의 전압강하 증가로 규정전압을 벗어나는 문제점를 발생시키고 있다. 이러한 문제점은 소방용 전원전압이 규정전압에 미달되어 각종 전기설비가 동작하지 못하는 심각한 결과를 초례할 수 있다. 이에 본 논문에서는 실제 준공된 소방대상물을 대상으로 전원공급장치의 용량 및 소방전기간선의 전압강하를 이론적으로 계산하여 문제점을 도출하고 분석하여, 소방전원계통에서 소방용 전원의 안정적이고 합리적인 설계와 운용에 대한 대책이 요구됨을 확인하였다.

UAE원전 화재방호계통 설계특성과 화재방호규제 개선 필요성 연구 (A Study on the Needs to Improve the Regulations and the Design Features of Fire Protection for UAE Nuclear Power Plants)

  • 마진수;이의평
    • 한국화재소방학회논문지
    • /
    • 제25권5호
    • /
    • pp.54-61
    • /
    • 2011
  • UAE(United Arab Emirates) 원전(원자력발전소)의 수출을 목적으로 UAE, 미국, 일본, 한국의 원전 화재방호규정을 상호 비교 검토하였다. UAE를 포함하여 미국, 일본의 원전 화재방호규정은 화재하중에 따른 화재위험도 분석결과에 따라 소화설비를 설치하도록 규정하고 있다. 반면, 우리나라는 소방관계법에서 원전을 발전시설로 구분하고 있으나, 원자력법에서는 원자로 및 관계시설로 분류하고 있고, 각 법률간 화재방호 설계기준도 상이하다. 앞으로 우리나라가 원전 수출국의 지위를 계속적인 유지하기 위해서는 화재 위험도분석의 결과가 설계에 반영될 수 있어야 한다. 결론으로, 국내 소방관계법이 원전의 특수성을 반영하기 위해서는 소방시설공사업법 시행령 제2조 2항의 성능위주설계를 해야 할 특정소방대상물에 원전이 추가되어야 함을 제안하였다.

교육용 가상원전을 이용한 화재안전정지분석에 관한 연구 (Study on Post-Fire Safe Shutdown Analysis using an Imaginary Plant for Training)

  • 이재호;김진홍
    • 한국화재소방학회논문지
    • /
    • 제32권1호
    • /
    • pp.57-65
    • /
    • 2018
  • 본 연구에서는 다중오동작을 포함하고 있는 화재안전정지분석 교육자료를 개발하기 위하여 가상원전에서의 화재안전정지분석을 결정론적 화재분석코드를 사용하여 수행하였다. 교육용 가상원전은 원자로건물과 보조건물로 이루어졌고, 총 22개의 방화지역으로 구성되었다. 교육용 가상원전의 각 방화지역에는 밸브, 펌프, 비상디젤발전기, 스위치기어, 모터제어반, 로직컨트롤러 등의 기기가 배치되었다. 교육용 가상원전 기기들은 두 개의 케이블로 연결되었으며, 각 케이블은 케이블 트레이를 따라서 방화지역을 지나간다고 가정했다. 방화지역분석을 위해 교육용 가상원전에 대한 기기 및 케이블 정보를 데이터베이스화하였고, 다중오동작 시나리오, 기기로직 및 케이블로직을 가정하여 방화지역분석을 수행하였다. 방화지역 분석결과 문제가 되는 케이블과 케이블 트레이에 대해서 3시간 내화성능으로 케이블을 래핑하는 완화조치를 적용하였다.

Experimental testing and evaluation of coating on cables in container fire test facility

  • Aurtherson, P. Babu;Hemanandh, J.;Devarajan, Yuvarajan;Mishra, Ruby;Abraham, Biju Cherian
    • Nuclear Engineering and Technology
    • /
    • 제54권5호
    • /
    • pp.1652-1656
    • /
    • 2022
  • Fire tests were conducted on cables using fire-retardant paint employed in nuclear power plants that transmit electrical power, control and instrument signals. The failure criteria of various power and control cables coated with fire retardant coating at three different coating thicknesses (~0.5 mm, 1.0 mm & 1.5 mm) were studied under direct flame test using Container Fire Test Facility (CFTF) based on standard tests for bare cables. A direct flame fire test was conducted for 10 min with an LPG ribbon burner rated at ten by fixing the cable samples in a vertical cable track. Inner sheath temperature was measured until ambient conditions were achieved by natural convection. The cables are visually evaluated for damage and the mass loss percentage. Cable functionality is ascertained by checking for electrical continuity for each sample. The thickness of cable coating on fire exposure is also studied by comparing the transient variation of inner sheath temperature along the Cable length. This study also evaluated the adequacy of fire-retardant coating on cables used for safety-critical equipment in nuclear power plants.

발전설비용 소화시스템의 성능 예측을 위한 CFD기법 적용 연구 (Application of CFD Method to Performance Prediction of Fire-Suppression System for Electric Power Utilities)

  • 정희택;배강열;김찬희;정인수;배진수;한용식;김종진
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.296-299
    • /
    • 2008
  • In the present research, the exclusive analysis system based on the CFD method were suggested to predict the fire-suppression performance of water mist fire-suppression equipments for design applications. The computing scope is ranged from starting pump to fire-suppression equipments, composed of three parts that calculation of flow rate and pressure distribution at each nozzle, examining of spray performance and predicting of fire-suppression performance in the fire space. Application were done to the fire-suppression system for electric power generation plants. The results were analyzed by comparison between numerical results and initial design conditions in terms of thermal and fluid mechanics.

  • PDF

원자력발전소 화재방호와 소방시설 기술기준 적용에 대한 고찰 (A Study on Fire Protection in Nuclear Power Plants and Application of the Code and Standards for Fire Protection Systems)

  • 김위경;정기신
    • 한국화재소방학회논문지
    • /
    • 제26권6호
    • /
    • pp.38-44
    • /
    • 2012
  • 원자력발전소 화재방호의 목표는 화재 시 원자로의 안전정지 상태를 유지하여 환경으로의 방사성물질 누출을 최소화하며, 종사자 인명안전 및 재산을 보호하는데 있다. 소방시설은 발생된 화재를 조기 감지 및 진압하여 화재로 인한 피해를 완화시킬 수 있는 심층방어개념에 입각한 중요한 방어수단의 하나이다. 그러나 소방방재청에서 제시하고 있는 소방시설 설치기준이 원자력발전소에 특화되어 있지 않아 인허가 시 별도의 심의 절차가 요구되고 있다. 또한, 성능위주설계와 같은 규정은 작업자의 인구밀도가 비교적 낮은 원자력발전소에 적용하는데 어려움이 있다. 이 논문에서는 원전 화재방호와 관련된 법령의 상세 검토를 통하여 도출된 근본적인 문제점과 KEPIC FPN의 국내 원전 적용성에 대한 평가를 통하여 소방시설에 대한 기술기준에 대한 개선방향을 제시하였다.

화력분야 녹색기술의 연구개발 동향 (The Research and Development Trend of Green Technology in the Field of Fire Power)

  • 안상태;강국정;홍석균
    • 한국군사과학기술학회지
    • /
    • 제13권3호
    • /
    • pp.358-364
    • /
    • 2010
  • The necessity for harmonically growing of economy and environment has been on the rise late in the twentieth century. Green transformation is defined as efficiency enhancement of conventional guns and ammunitions. We also define green innovation as evolution of fire power systems breaking with conventional methodology. This kind of green innovation could even change a paradigm of warfare in the future. In this paper, we classify the green technology in the field of fire power into five technological groups, and the research and development trend of green technology in the field of fire power is analyzed.

대기전력차단으로 인한 에너지절약과 전기화재예방에 관한 연구 (A Study on the Energy Saving and Electric Fire Prevention was Caused by with Interception of Standby Electric Power)

  • 김만건;임성진;이창우
    • 한국화재조사학회논문지
    • /
    • 제11권1호
    • /
    • pp.66-73
    • /
    • 2008
  • 본 연구에서는 한국전기안전공사 서울지역본부 내 전기 전자 제품을 선정하여 각 기기의 전력사용량을 측정하고, 각 기기에 대해 대기전력 차단장치인 세이버 설치 전 후의 대기전력을 측정함으로서 평상시와 전원의 "OFF"시 대기전력을 비교함으로서 절전효과를 조사하였다. 연구결과 대기전력 차단장치인 세이버를 설치하였을 경우 전기 에너지 낭비요인을 원천적으로 제거함으로서 약 18%의 절전효과가 있었으며, 대기전력을 차단함으로서 전기화재를 근원적으로 예방하고 서지 등 이상전압에 의한 충격을 방지함으로서 전기 전자제품의 수명을 연장할 수 있었다.

  • PDF