• Title/Summary/Keyword: Fire Module

Search Result 149, Processing Time 0.023 seconds

CFD-based Fire Accident Impact Analysis in Clean Room for semiconductor PR Process (반도체 PR 공정의 클린룸내 CFD 기반 화재 사고 영향 분석)

  • Chun, Kwang-Su;Yi, Jinseok;Park, Myeongnam
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.6
    • /
    • pp.35-44
    • /
    • 2021
  • The PR (Photo Resist) process in the semiconductor process is a process that uses a mixture of flammable substances. Due to the process equipment is installed in a clean room and when flammable substances leak, there is a high risk of suffocation, fire, and explosion. It is necessary to analyze the impact of accidents that may occur during operation and to evaluate whether the safety of workers can be guaranteed. In this study, the value of radiant heat and temperature change at the monitor point set up virtual inside the clean room was confirmed through CFD simulation of 10 leak and fire scenarios using the FLACS CFD - Fire Module. A fire that occurs inside a clean room transfers high radiant heat to the inter-story structure, but its scope is quite limited, and it is unlikely that it will collapse in a single fire accident. There was no scenario in which two stairs leading to the exit were exposed to high radiant heat at the same time due to a fire accident, therefore workers were able to escape in case of a fire. In addition, it was confirmed that the level of radiant heat and temperature rise rapidly decreased as they moved downstairs. According to the API 520 standard, workers exposed to 6.31 kW/m2 of radiant heat that workers can withstand for 30 seconds were confirmed that it was possible to sufficiently escape from the inside.

Development of Monitoring RF System on Leakage of Gas Cylinder in Gaseous Fire Extinguishing System (가스계 소화시스템용 소화약제 저장용기 누설 검출 무선 시스템 개발)

  • So, Soo-Hyun;Oh, Ju-Hwan;Cha, Cheol-Woong;Lee, Dae-Kuen
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.7-10
    • /
    • 2008
  • In our study, Monitoring RF System in real-time on leakage of gas cylinder is developed. The system is consisted of Pressure Transmitting part, Main Controller and Operating program. The pressure data of gas cylinder are transmitted to the modem of main controller part by RF module of Pressure Transmitting part and the data received through the modem are recorded in real-time and showed the situation of gas cylinder on the PC monitor. Through the test on the case of the artificial pressure-reduction, the detecting performance. of the developed system is conformed.

  • PDF

Compact near-eye display for firefighter's self-contained breathing apparatus

  • Ungyeon Yang
    • ETRI Journal
    • /
    • v.45 no.6
    • /
    • pp.1046-1055
    • /
    • 2023
  • We introduce a display for virtual-reality (VR) fire training. Firefighters prefer to wear and operate a real breathing apparatus while experiencing full visual immersion in a VR fire space. Thus, we used a thin head-mounted display (HMD) with a light field and folded optical system, aiming to both minimize the volume for integration in front of the face into a breathing apparatus and maintain adequate visibility, including a wide viewing angle and resolution similar to that of commercial displays. We developed the optical system testing modules and prototypes of the integrated breathing apparatus. Through iterative testing, the thickness of the output optical module in front of the eyes was reduced from 50 mm to 60 mm to less than 20 mm while maintaining a viewing angle of 103°. In addition, the resolution and image quality degradation of the light field in the display was mitigated. Hence, we obtained a display with a structure consistent with the needs of firefighters in the field. In future work, we will conduct user evaluation regarding fire scene reproducibility by combining immersive VR fire training and real firefighting equipment.

The Evaluation of UWB Wireless Communication Position Determination Function in an Enclosed Space for Fire Fighting (소방활동을 위한 밀폐공간 무선통신 측위성능 평가)

  • Kim, Dong-Hyun;Kim, Chung-Il
    • Fire Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.117-122
    • /
    • 2017
  • The absence of fire fighters' connection to communication can bring about increased loss of life due to errors and delays in rescue and actions and danger to their own safety. Therefore, when communication infrastructure has been destroyed in an enclosed space, it is necessary to set up an emergency wire or wireless telecommunication environment to fire fighting and to secure safer environment to deal with the disaster by checking the location of fire fighters. In this research, for the establishment communication environment in an enclosed inside using Ultra-Wide Band (UWB) wireless communication network, the performance of communication position determination of a single UWB communication module was evaluated regarding 6 kinds of indoor surroundings. When the communication distance in an indoor environment of each 6 channels bandwidth of UWB communication frequency was measured, the results were as follows: the open space (Ave. 15.5 m, Max. 20 m), the corridor (Ave. 17.33 m, Max 20 m), inside retaining home furnishings (Ave. 15.3 m, Max. 20 m), vertical stairs (Ave. 4.33 m, Max. 6 m), horizontal space with a closed fire door (Ave. 6.5 m, Max. 17 m). It was also found out that the communication function and the distance function were best in the frequency range from 6489.6 to 1081.6 MHz by 7 Ch. Accordingly, the establishment of communication environment in an enclosed space is judged to be possible when UWB communication module is set up at 20 m apart and multiple channels are used.

Design of the Integrated Fire Automation System(IFAS) on based P-Type Fire Control Panel (P형 수신기 기반 통합화재 자동 시스템의 설계)

  • Kim, Hyun-Ju;Park, Jae-Heung;Seo, Yeong-Geon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.15 no.12
    • /
    • pp.133-142
    • /
    • 2010
  • P-type fire control panel, currently in use, has a big hazard that can cause the large scaled human death tolls and property damage in the massive fire because it is difficult to identify in real time the location of fire outbreak and whether search-device are broken down or not. In this paper, I suggest that the integrated fire automation system on based p-type fire control panel should be used, which can detect in real time the signal that occur when whether search-device are broken down or not, and can detect the arisen circumstances information of p-type fire control panel on the fire signal in the far away. The devised systems have designed and embodied the analysis of circumstances information and module that can analyze the circumstances information from the p-type fire control panel and the part of internet access installment which can gather and deliver the circumstances information from the fire prevention facility receiver.

A Study on the Fabrication of the Sensor Module for the Detection of Resistive Leakage Current (Igr) in Real Time and Its Reliability Evaluation (실시간 Igr 검출을 위한 센서 모듈의 제작 및 신뢰성 평가에 관한 연구)

  • Lee, Byung-Seol;Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.1
    • /
    • pp.28-34
    • /
    • 2018
  • The purpose of this study is to fabricate a sensor module to detect the resistive leakage current (Igr) in real time that occurs to low voltage electric lines and to verify its reliability. In the case of the developed sensor module, wires are inserted into the zero current transformer (ZCT) and current transformer (CT) in advance and then the branch line is connected to the circuit breaker. The measurement result of the resistance of the distribution panel equipped with the developed sensor module shows that the resistance is $0.151m{\Omega}$ between the R and R phases, $0.169m{\Omega}$ between the S and S phases, and $0.178m{\Omega}$ between the T and T phases, respectively. The insulation resistance measured at AC 500 V and 1,000 V is $0.08m{\Omega}$ between the R, S, T and N phases, respectively. Then, the insulation resistance measured at DC 500 V is $83.3G{\Omega}$ between the R, S, T and G terminal, respectively. In addition, the applied withstanding voltage is AC 220 V/380 V/440 V and it was found that characteristics between all phases are good. This study measured the standby power by installing the developed sensor module at the rear of the MCCB and switching the circuit breaker on sequentially. The standby power is 1.350 W when one circuit breaker is turned on, 1.690 W when 2 circuit breakers are turned on, and 4.371 W when 10 circuit breakers are turned on. This study also verified the reliability of the standby power of the distribution panel equipped with the developed sensor module using the Minitab Program (Minitab PGM). Since the analysis shows the statistical average of 1.34627 in the reliable range of normal distribution, standard deviation of 0.001874, AD of 0.554, and P value of 0.140, it is found that the distribution panel equipped with the developed sensor module has high reliability.

Analysis on the Fire Accident of Vehicle Due to Damage of the Vehicle's Electrical Components (차량 전장부품 손상으로 인한 차량화재 사고사례 분석)

  • Park, Nam-Kyu;Kim, Jin-Pyo;Nam, Jung-Woo;Sa, Seung-Hun;Song, Jae-Yong
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.4
    • /
    • pp.32-38
    • /
    • 2015
  • In this paper, we analyzed the vehicle fire accidents due to damage of vehicle's electrical components, which is applied to a vehicle. In recent development of electrical components technology, approximately 40% of vehicle manufacturing parts have applied electronic circuit technology. Phenomenon such deterioration of insulating performance or electric breakdown on the vehicle's electrical components and printed circuit boards(PCBs) resulted from moisture, contamination and aging due to repetitive operations, lead to the vehicle fire. Therefore, the application of electrical components with adequate electric capacity for vehicle and usage of molding techniques using a non-combustible materials to shut off the oxygen should be applied in order to prevent vehicle fire due to damage of the electrical components and PCBs.

Mobile Guidance System for Evacuation based on Wi-Fi System and Node Architecture

  • Raju, Timalsina;Kim, Woo Sung
    • Journal of Information Technology Applications and Management
    • /
    • v.26 no.5
    • /
    • pp.41-56
    • /
    • 2019
  • Recently great loss of life and property is occurring because of fire, natural disaster, earth quake, tsunami and so on. People spend 80~90% of their time indoor environment like office, supermarket, campus. Therefore Indoor navigation and guidelines system became so essential for most of all. Incase of emergency we must be careful earlier, in such a cases 5G kind of new technology may also cannot work. So immediate action and quick routing notification for guidelines and protection is the most. Considering this issue We proposed indoor evacuating guidance system based on microcontroller Wi-Fi board for Indoor APP using mobile. Focusing various kind of technology like, ok google, voice search APP we purposed node architecture based system. When we listen fire alarm while living inside the room. Then to be safe we connect with server and start Arduino UNO+IoT ESP8266 Wi-Fi shield version1-IoT module to store data in MySQL DB server. We make application to escape out from the building up-to the three exits giving information from source point to destination. Our program can send information to the users emergency location and situations. For this when the user get sound or vibration in their mobile device it indicate fire out near by. At that time we update message from Arduino to DB server for the fixed current position inside the building which give routing signal for that fire out location by changing values from 0 to 1. We have user in point 10 where user is near by. Later we detect Wi-Fi signal form Nodemcu as room of each floor and try to connect with user. Main purpose of this paper is to save life of people in short time and find out the shortest path up to nearest exits in the time of emergencies and rescue them.

Development of Emergency Exit Guidance Lamps using the Characteristics of Each Sensor in Case of Fire (화재 발생 시 센서별 특성을 이용한 비상구 유도등 개발)

  • Kim, Jong-Kwan;Jeong, Do-Hyeon;Yu, Yong-Woo;Yang, Min-Hyeok;Lee, Boong-Joo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.6
    • /
    • pp.1019-1028
    • /
    • 2021
  • Emergency exit guidance lights were designed and manufactured to quickly determine the location of the emergency exit in the event of a fire using a gas sensor, an illumination sensor, a temperature sensor, an Arduino Uno, and a Bluetooth module. This research was designed such that, when a fire breaks out, a red arrow appears as the illuminance value is low and a green arrow as the illuminance value is high to improve visibility when detecting high temperature and smoke. In addition, it is designed to prevent more serious conflagration by applying an alarm sound and text transmission algorithm using a communication module to transmit text messages indicating a 174Hz alarm sound and a fire location to prevent more serious conflagration.

A Numerical Modeling of Smoke Behavior and Detection for Fire Developed in International Space Station (국제우주정거장 내부 화재시 연기거동 및 감지특성에 관한 수치 모델링)

  • Park, Seul-Hyun;Lee, Joo-Hee;Kim, Youn-Kyu;Hwang, Cheol-Hong
    • Fire Science and Engineering
    • /
    • v.26 no.6
    • /
    • pp.51-56
    • /
    • 2012
  • The onset of fire on the International Space Station (ISS) is a critical problem that can threaten the life of crew members onboard and thus instantaneous fire detection and extinguishment technology has been considered as one of the most important aspects in the ISS operation. In the present study, a numerical analysis was performed to better understanding of the characteristics of smoke behaviors and detection in a pressurized module of the ISS using the NIST Fire Dynamic Simulator (FDS). Numerical results indicate that the smoke flow patterns under zero-gravity condition are clearly different from those under normal gravity condition. In addition, the results obtained from numerical simulations coupled with the PM internal flows are expected to provide basic and useful information in designing the microgravity fire detection devices and establishing in fire response protocol for astronauts or the crew members.