• Title/Summary/Keyword: Fire Management

Search Result 1,689, Processing Time 0.024 seconds

A Study on the Improvement Method of the Fire Department Connection for Fire Fighting at the Shopping Center Building (상가건물 소방용 연결송수관설비 송수구의 개선방안에 관한 연구)

  • Lee, Young-Sam
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.4
    • /
    • pp.11-17
    • /
    • 2016
  • Currently, the number of a shopping center building is increasing because most people want to go a shopping center building easily for buying many things and eating some foods. That are a normal trend these days. However, the increasing number of shopping center buildings has been increasing the number of shopping center building fires which also have been making social problems. Therefore, this study was conducted for the fire department connection among other fire facilities because it is important for fire suppression. The research subject is on the fire department connections that are on 70 shopping center buildings of more than 5 years old constructed. Survey and analysis were conducted for 70 fire department connections. The result of this study is that all installed fire department connections have a type that includes one or two holes each at 65mm wide, and the average distance between fire department connections and access roads is 4.85m. The total average percentage of insufficiency conditions such as drive ways for fire trucks, visibility, accessibility, pressure range sign, installed height, cover of the hole, etc. is 45.3%. So improvement of law and systems, that are fire facility construction and maintenance implementations, will be needed in my opinion.

A investigation study on the Maintenance Management for Fire Safety According to Analysis of Fire Accident in Korea(I) (국내 지하공동구의 화재사례 분석을 통한 화재안전관리방안에 관한 조사 연구(I))

  • Kim, Dong-Eun;Shin, Yi-Chul;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.328-333
    • /
    • 2008
  • Underground utility tunnels are important facilities not only as an essential social infrastructure for modern information society but as the economic and efficient carrier of various urban infrastructure including electric power lines, communication cables, gas pipes, water supply and drainage pipes and energy supplies to metropolitan and residential areas. It is the aim of this study to investigation study on the Maintenance Management for Fire Safety According to Analysis of Fire Accident in Korea.

  • PDF

The Way of operations and tactics for Disaster plan of High-rise Buildings (초고층 건물의 재난 발생 시 작전전술 방안)

  • Lee, Jung-Il
    • Journal of the Korea Safety Management & Science
    • /
    • v.14 no.3
    • /
    • pp.77-83
    • /
    • 2012
  • Recently, For the most efficient use of spaceis, high-rise buildings tend to increase. So it is with Korea, too. Besides, today high-rise buildings grows due to fire damage to life and property at large. In this study, Through analysis of domestic and foreign fire case and listen to the high-rise building fire managers, tenants, professionals advice, when the fire from the high-rise building, effective fire suppression tactics should we wish to research ways. In addition, we have used the car gondola was installed outside the fire suppression methods in studying. So that fire-fighting is a fire place can be reached quickly, many casualties and property damage, will be reduced.

A Study on the Role of Fire Fighting and Rescue Squad in terms of Fire Investigation (화재조사 측면에서의 화재진압 및 구조대원의 역할에 대한 연구)

  • Lee, Seung-Hun;Lee, Chang-U
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2012.04a
    • /
    • pp.461-470
    • /
    • 2012
  • Fire scene is mostly destroyed by the flames but fire fighter's fire suppression and rescue activities also destroys a substantail portion. Structures and furnitures which has already become weaken can be easily damaged. Or when structures built up by moving to another location, it's very hard to restore the original state. Also if it is restored, the object has no evidence that it has existed. In all scenes, the scene can't be preserved when quick extinguishment, rescue activities and preventation of fire spread is needed. On this paper, it reviewed the notes about the possibility of field damage by fire suppression and rescue squad's activities. Also it has reviewed the notes how to minimize the field damage by putting out fires and rescue activities by observing the precautions. The reviewed information will help to make guidelines for preserving the scene. By this, it is expected to make a field study exactly by collecting more valid evidence.

  • PDF

Utilization of the robot's field of fire prevention research (로봇의 소방방재분야 활용방안 연구)

  • Lee, Jeong-Il
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2013.04a
    • /
    • pp.471-484
    • /
    • 2013
  • Large and complicated firefighting environment is accelerating in the early activities in the field of fire officials at the time limit situation leads to people's lives and property damage, as well as the loss of the Fire Service. Therefore, the state-of-the-art technology that can respond to rapidly changing fire environment urgently in the field of fire fighting have been introduced should be utilized. These intelligent firefighting robots build daegukmin firefighting safety net that can be used when. Other advanced technology industries, the most effective ways that can be introduced into the firefighting shall be provided in the current situation of the industry's initial firefighting robots.

  • PDF

Fire Risk Analysis through Airfryer's Fire Cases and Reproduction Experiments (에어프라이어의 화재사례와 재현실험을 통한 화재위험성 분석)

  • Lee, Jung-Il;Jo, Myeng-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.22 no.2
    • /
    • pp.39-46
    • /
    • 2020
  • This paper recognizes the risk of ignition of air fryer (machine that can cook fried dishes with hot air without oil) that is far exceeding the sales rate of microwave ovens, which is necessary to modern household kitchen, and identifies fire risk through the operation principle of the process of heat transfer, and the main structure of the machine. The fire test that we conducted is to observe the risk of ignition of the machine due to the damage to the safety system and the possibility of igniting oil paper along with food, to experiment with the possibility of ignition due to blockage of the exhaust due to obstacles, and accumulation of oil stains on the hot wire, and to present the method of fire control and devise countermeasures.

An Analysis of the importance in fire-stations' works and redesign by disaster management steps (재난관리 단계별 소방업무 중요도분석 및 업무재설계)

  • Park, Chanseok
    • Journal of the Society of Disaster Information
    • /
    • v.10 no.4
    • /
    • pp.572-582
    • /
    • 2014
  • Fire-stations' works limited to the existing fire protection rescue and emergency services in rapidly changing disaster environment are not difficult to deal with the fire service demand of the people any longer. In this study, after calculating the importance of the disaster management about fire-stations' works by disaster management steps thorough a survey of experts about Fire and Disaster, firefighting tasks are to be redesigned. Experts have the higher rating in preparation step of firefighting tasks. Because securing resources and building systems in preparation step and safety training in prevention step have a high importance, it is required to improve efficiency of firefighting tasks through redesign. The most important point in redesign is to realize fire-stations' works are to expand and to develop such a policy if fire-offices excavate the civil and government cooperation works and provide such legal and institutional basis of establishment and operation. And it should be sought to maintain international cooperation for international disaster response. Ultimately, fire-offices will have further expansion in quality and simultaneously quantitatively by excavating 'collaboration (business cooperation)' or enhancing existing works in addition to existing 'fire and rescue, first aid' business.

Scientific fire investigation by NFPA 921 CODE based on frozen warehouse fire case (냉동창고 화재 사례를 기반으로 하는 NFPA 921 CODE에 의한 과학적 화재조사 연구)

  • Park, Kyong-Jin;Lee, Yong-KI;Cha, Sung-Sig;Jung, Dong-Young;Kim, Jang-Oh
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.8
    • /
    • pp.78-85
    • /
    • 2018
  • In this study, we investigated the cases where there were many opinions in the judgment of the cause of ignition in the case of 20 cases of frozen warehouse fire that occurred in 2017.The research methodology is the scientific fire survey method prescribed by the NFPA 921 CODE. Scientific fire investigation method is fire investigation method by logical reasoning through hypothesis setting, minimizing errors in judgment of ignition source. On the other hand, unscientific fire investigation methods cause many errors by the intervention of irrational factors such as subjective estimation, reasoning judgment, etc. This eventually leads to the problem of human and material responsibility and academic deterioration. In particular, fire not seen as compared to sighted fire makes more errors in ignition sources in the cause investigation. In this study, we set the hypothesis A and hypothesis B based on the review of the fire investigation report and the field survey on the fire case of the cold storage warehouse front line that occurred at ** city ** Mart in 2017.The set hypothesis was tested by the NFPA 921 code. This analytical method will be constructed by NEW Paradigm as a source of fire that is not seen in the future and a source of ignorant fire.In addition, the experimental data of this study will be used to inform the manufacturer and operator of the refrigeration warehouse and serve as basic data for fire prevention.

A study on Fire Case and Countermeasure of Tourist Hotel (관광호텔의 화재손해 위험관리방안 - 화재발생현황과 대형화재사례 분석 중심)

  • Han, Sukman;Son, Jung Hyoun;Kim, Jong Won
    • Journal of the Society of Disaster Information
    • /
    • v.8 no.4
    • /
    • pp.362-375
    • /
    • 2012
  • Tourist hotels are equipped with facilities such as accommodation and restaurants, exercise, recreation. Unspecified guests, visitors and management of tourist hotels are very vulnerable on the casualties and property losses due to fire peril exist. In this study, we analysis that the fire statistics status of tourist hotels from 2001 to 2010. And the 15 cases of a large hotel fire are reviewed. The total number of fires on hotel are consist of a hotel rooms fire(33.2%), a restaurant kitchen fire(11.8%). And the major causes of the fire are an electrical fire (40.8%), a cigarette fire (14.5%) and a hot-work fire (9.2%). In case study, the fire wall defect and combustible materials are major fire loss causes for 10year. Each tourist hotels are needed a development of suitable fire risk management and a field operations. A hotel is required an active fire risk management on a preventive inspection, an education and training, and a preventive maintenance. It is necessary that a fire wall maintenance to prevent of the spread of a fire and a sprinkler installation of whole area to protect fire. And it is very important an emergency response for evacuation of guest, and operate emergency procedures on a fire or emergency situation.

A Study on the Consciousness Survey of Geriatric Hospital Workers for Fire Safety (요양병원 종사자의 소방안전 의식조사에 관한 연구)

  • Lee, Young-Sam
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.3
    • /
    • pp.91-97
    • /
    • 2016
  • Currently many geriatric hospitals have been built in Korea because younger people don't want to care their parents and have been decreasing for labor. However, the increasing geriatric hospitals make the increasing fire safety accidents. Therefore, this study is conducted by survey and face-to-face talk for analyzing fire safety problem of twelve among 15 geriatric hospitals in the north of Chung-Buk area. The result of this study is that infection and fall accident are higher than others and fire safety implement rate of safety rule followed by CEO is 71%. Monthly safety training rate is 49% and initial fire safety training not conducted is 33%. Yearly outside fire safety training rate is 97% but workers who know how to use fire evacuation facility are 61%. Furthermore, safety instruction rate of fire safety manager is much higher than supervisor's safety instruction. The cause of accident is facility (33%). In conclusion, the institution and rule improvement need for decreasing infection and falling, increasing implement level of fire safety rule and fire safety training, participation rate of supervisor for fire safety, quality of fire safety training, and investment of fire safety facility.