• Title/Summary/Keyword: Fire Load

Search Result 513, Processing Time 0.028 seconds

Characterization of Live Fire Load in Buildings - Heat Release Characteristics of Typical Live Fire Load in Post Office Building - (건축물의 적재가연물 특성에 관한 연구 -우체국 적재가연물의 연소성상 -)

  • Nam, Dong-Gun;Yuji, Hasemi;SaKong, Seong-Ho;Jung, Jong-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.7-10
    • /
    • 2008
  • Heat release characteristics of live fire load are an important parameter for performance oriented fire safety design of a building. While investigations have been carried out on the fire load and its burning behavior in office, residential and commercial buildings and so on, little effort has been paid for the rational treatment of fire load in post office buildings in Japan. In this report, burning behavior of typical combustible objects in post office buildings are studied by measuring heat release rates of plastic palettes with and without postal envelopes or packages and special containers loading numbers of palettes. The test results suggest that dynamic heat release rate is highly dependent on the condition of palettes especially if they load appropriate amount of postal envelopes or not.

  • PDF

Prediction of the Fire Behavior According to the Fire Load in an Underground Life Space (화재하중에 따른 지하생활공간의 화재성상 예측)

  • Chae, Han-Sik;Suk, Chang-Mok;Kim, Ie-Sung;Lee, Ji-Hee;Kim, Wha-Jung
    • Fire Science and Engineering
    • /
    • v.21 no.1 s.65
    • /
    • pp.51-59
    • /
    • 2007
  • The purpose of this study is analyzing the fire behavior according to the fire load for G underground shopping mall located in Daegu city. when predict fire behavior, fire load and ventilation coefficient are important factor who dominate fire temperature or fire continuance time. Therefore, size of unit room, opening size and inflammable investigated on the field. Fire load calculated using unit calorific value by each material of inflammable that investigate. And reduction model experimented fire load about 6 models with variable. Fire behavior analyzed by heat flows of inside space that temperature rise and temperature change by time of fire source.

Characterization of Live Fire Load in Buildings - Heat Release Characteristics of Typical Live Fire Load in Bookstore - (건축물의 적재가연물 특성에 관한 연구 -대형서점의 적재가연물 연소발열성상-)

  • Nam, Dong-Gun;Yuji, Hasemi;Jung, Jong-Jin;Lim, Woo-Sub;SaKong, Seong-Ho
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.3-6
    • /
    • 2008
  • Heat release characteristics of live fire load are an important parameter for performance oriented fire safety design of a building. While investigations have been carried out on the fire load and its burning behavior in office, residential and commercial buildings and so on, little effort has been paid for the rational treatment of fire load in bookstore. In this report, burning behavior of typical combustible objects in bookstore are studied by measuring heat release rates of bookshelf with book.

  • PDF

Heat Release Characteristics of Typical Live Fire Load in Large Bookstore (대형서점 적재가연물의 초기 연소발열성상)

  • Nam, Dong-Gun
    • Fire Science and Engineering
    • /
    • v.25 no.2
    • /
    • pp.88-94
    • /
    • 2011
  • Heat release characteristics of live fire load are an important parameter for performance oriented fire safety design of a building. While investigations have been carried out on the fire load and its burning behavior in office, residential and commercial buildings and so on, little effort has been paid for the rational treatment of fire load in bookstore. In this report, burning behavior of typical combustible objects in bookstore are studied by measuring heat release rates of bookshelf with book. Based on the results, it has reviewed fire safety when a fire accident occurs on the large bookstore and suggested peak heat release rate per burning surface, fire growth rate, etc of the live fire load required for fire safety design in bookstore.

Comparative Study on the Estimation Method of Fire Load for Residential Combustibles (주거공간 가연물의 화재하중 산정방법의 비교연구)

  • Choi, Su-Young;Kim, Jung-Yong;Nam, Dong-Gun;Kim, Sung-Chan
    • Fire Science and Engineering
    • /
    • v.27 no.6
    • /
    • pp.38-43
    • /
    • 2013
  • As a preliminary study to evaluate the reliability of the calculation method of fire load for residential furniture combustibles, the present study estimates the fire load considering the volume data obtained by the 3D geometrical information of combustibles and material properties based on the literature survey and sample burning test. A kitchen sink cabinet, couch and workstation were investigated for estimating its fire load and real fire test have been performed to measure total energy released from the combustibles. Based on total energy measured from real fire test, the relative error of the estimated fire load due to literature survey and measured material properties showed 6~120% and less than 20%, respectively. It shows that the estimation error of fire load are greatly affected by its material properties as well as geometrical information of combustibles and the present study will be able to contribute to accurate estimation of fire load.

Study on Fire Resistance of H-Section Beams Filled with Concrete at Web (웨브 보강 형태에 따른 H형강 보부재의 내화성능에 관한 연구)

  • Kwon, In-Kyu
    • Fire Science and Engineering
    • /
    • v.25 no.5
    • /
    • pp.76-84
    • /
    • 2011
  • Steel beams are one of primary member and those carries the horizontal load and floor load to axial member. To avoid structural failure when the steel beams are exposed to fire, fire resistance performance requires. Till now, the evaluation for fire resistance of the beam was conducted using the maximum load and standard fire curve defined in the KS F 2257. But recently the constructional patterns are changing toward multi-function performance to get a better structural performance and fire resistance as well. In this paper to get the databases for fire resistance, limiting temperatures of the beam, load-bearing fire tests according to load ratios, two grades of compressive concrete strengths were applied.

An Experimental Study on the Fire Resistance effect on load ratio and compressive strength of the CFT Column under loading in fire (CFT 기둥의 축력비 및 압축강도 변화에 따른 화재거동 영향인자에 관한 실험적 연구)

  • Cho, Kyung-Suk;Kim, Heung-Youl;Kim, Hyung-Jun;Kwon, In-Kyu;Park, Kyung-Hun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.04a
    • /
    • pp.371-376
    • /
    • 2010
  • The strength of steel material in a concrete filled steel tube (CFT) is reduced in fire, but the filled interior concrete structurally ensures the fire resistance due to its high thermal capacity. More, the contractibility of CFT is excellent since it can be constructed without form work. This research analyzed the interior concrete strength and deformation characteristics, which are the influence factors of the fire resistance of CFT, in proportion to the axial load ratio. The fire resistance performance according to changes of the axial load ratio showed great fluctuation. As $280{\times}280{\times}6$ CFT columns with the concrete strengths of 24 MPa and 40 MPa and the axial load ratios of 0.9, 0.6, and 0.2 in accordance with KS F 2257-1 and 7 were heated with loading to examine the fire resistance performance, the 24 MPa concrete exhibited the fire resistance time as 27, 113, and 180 minutes for the axial load ratios, 0.9, 0.6, and 0.2 respectively. In case of 40 MPa concrete, the fire resistance time were turned out to be 19 and 28 minutes for the axial load ratios, 0.9 and 0.6 respectively. The results of 40 MPa concrete showed the much lower fire resistance performance when comparing with those of 24 MPa concrete. The fire resistance performance was not increased significantly when the axial load ratio was reduced. Therefore, the deceased fire resistance performance of high strength concrete is assumed to be caused by the internal pressure increase upon the heat application.

  • PDF

A Study on the Prediction of Fire Load in case of a Train Fire (철도 차량 화재시 화재강도 예측을 위한 연구)

  • Yang, Sung-Jin;Chang, Jung-Hoon;Gang, Chan-Yong
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.2101-2108
    • /
    • 2008
  • Most of train fires which occur in usual cases do not grow up significantly on a large scale enough to bring about casualties and harmful damages. However, the consequence of some train fire accidents can be devastating disaster so that it would be even recorded in history in unusual cases. Accordingly, such a probability of fire disaster cannot be ignored in aspect of the railway safety assesment. A scale of injury and damage is very difficult to predict and analyze. Because it is depend on various factors, i.e. fire load, burning period, facilities, environment condition, and so on. Thus, a prediction of fire load could be understood as a one methodology to estimate railway safety assesment. The summation method which is one of them is used to evaluate the overall fire load by assuming that sum of heat release rate per unit area or mass of each composite material equals the total. However, since the train fire is classified into a compartment fire in under-ventilation condition. The summation method do not estimate a fire load completely. In this journal, Various methods to predict fire load are introduced and evaluated. Especially the fire simulation tool FDS(Fire Dynamics Simulator)which is based on the CFD(Computational Fluid Dynamics) is introduced, too. Through the FDS simulation, numerical analyses for the fire load and flame spread are performed. Then, these results of the simulation are validated through the comparison study with the experimental data. Then, limitations and approximations including in simulation process are discussed. The future direction of research is proposed.

  • PDF

Experimental Study on Combustion Characteristics of Live Fire Load in a Bookstore (서점의 적재가연물의 연소특성에 관한 실험적 연구)

  • Nam, Dong-Gun
    • Fire Science and Engineering
    • /
    • v.25 no.5
    • /
    • pp.47-53
    • /
    • 2011
  • Fire load in buildings greatly contribute to the time and scale of fire according to the type and quantity of the fire load. Because bookstores have a large quantity of fire load compared with other buildings which may lead to large scale fires, however, their heat release characteristics have been hardly investigated. In this study, to obtain the data applicable for the performance-based fire safety design of bookstores, the specimens representing stacked fire loads were heated in a furnace in compliance with the standard heating curve of ISO834-1:1999 to investigate their heat release characteristics. From the experiment result, the combustion velocity and heat release rate required for performancebased fire safety designs are obtained.

STRUCTURAL TEST AND ANALYSIS OF RC SLAB AFTER FIRE LOADING

  • Chung, Chul-Hun;Im, Cho Rong;Park, Jaegyun
    • Nuclear Engineering and Technology
    • /
    • v.45 no.2
    • /
    • pp.223-236
    • /
    • 2013
  • In the present study the behavior of fire and the residual strength of fire-ignited RC slabs are investigated by experimental tests and numerical simulations. The fire tests of RC slabs were carried out in a furnace using the ISO 834 standard fire. The load capacity of the cooled RC slabs that were not loaded during the fire tests was evaluated by additional 3 point bending tests. The influence of the proportion of PP (polypropylene) fibers in the RC slabs on the structural behavior of the RC slabs after the fire loading was investigated. The results of the fire tests showed that the maximum temperature of concrete with PP fiber was lower than that of concrete without PP fiber. As the concrete was heated, the ultimate compressive strength decreased and the ultimate strain increased. The load-deflection relations of RC slabs after fire loading were compared by using existing stress-strain-temperature models. The comparison between the numerical analysis and the experimental tests showed that some numerical analyses were reliable and therefore, can be applied to evaluate the ultimate load of RC slabs after fire loading. The ultimate load capacity after cooling down the RC slabs without PP fiber showed a considerable reduction from that of the RC slabs with PP fiber.