• Title/Summary/Keyword: Fire Fighting Law

Search Result 44, Processing Time 0.024 seconds

Improvement Plan of Fire-Related Laws of Disaster Prevention Facilities of Road Tunnels (도로터널 방재시설의 소방관계법령 개선방안)

  • Seo, Hyo-Seon;Whang, Young-Kwon;Lee, Seung-Chul
    • Fire Science and Engineering
    • /
    • v.33 no.2
    • /
    • pp.124-131
    • /
    • 2019
  • When a fire occurs in a road tunnel, it is likely to develop into a major disaster because of its sealed structural characteristics. Because of this, a range of disaster prevention facilities should be installed, and they should show their appropriate functions in fire prevention and response. In addition, the installation of essential disaster prevention facilities is missing due to the lack of considering an extension of continuous tunnels and soundproof tunnels. For these reasons, it was judged that an amendment to the law would be necessary. Therefore, this paper reviewed the changes in domestic laws related to the disaster prevention facilities of road tunnels, and the results of the study on the parts that need to be revised in the fire-related laws through a comparative analysis between laws are as follows. First, consecutive tunnels should consider the sum of the extensions of the individual tunnels and ensure that the soundproof tunnels are included in the category of tunnels in the law. In this way, the necessary disaster prevention facilities should be installed. Second, it is necessary to secure a legal justification for installing disaster prevention facilities in tunnels. Therefore, it is essential that water mist fire extinguishing system facilities, emergency broadcasting facilities, and leading lights, which are excluded from installation in tunnels, are specified in the Fire-related laws. Third, to specify in the law that air respirators must be provided in the tunnel is necessary from the viewpoint of the field response. Accordingly, it will make a great contribution to the fire-fighting activities and the life-saving efforts by fire-fighters.

Evaluation of Escape Safety Depending on the Number of Users of Residential Convenience Facilities in the Apartment Complex and the Kind of Elevators

  • Cho, Seong-Suk;Kong, Ha-Sung
    • International Journal of Advanced Culture Technology
    • /
    • v.9 no.4
    • /
    • pp.376-384
    • /
    • 2021
  • This study wants to provide basic data on effective escape safety plans when residents of apartment complex use residential convenience facilities. The findings of the analysis are as follows. First, when this study applied the actual number of users (No=54) of those facilities, the existence of elevator for escape reduced the escape time by 189.0 seconds. Second, when the number of users was calculated on the standard of the number of people who can be accommodated for performance based design (No=316), the existence of the elevator for escape reduced the escape time by 173.5 seconds. Finally, when the number of users was calculated on the standard of installing fire-fighting facilities (No=122), the existence of the elevator for escape reduced the escape time by 159.2 seconds. As a result, it was found that elevator for escape reduces the escape time from fire. Accordingly, it is necessary to revise the construction law to make it obligatory for residential convenience facilities to be equipped with elevator for escape. Currently, apartment buildings lower than 30 stories have either elevator for passengers or elevator for escape. Thus, in future studies, it is necessary to compare escape times in fire depending on the kinds of elevator, and identify the usefulness of elevator for escape.

A Study on the Urban Disaster Management System - Focusing on Fire Service - (도시재난관리체제 운영실태 분석 연구 - 소방을 중심으로 -)

  • Baek, Dong-Seung
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.4 no.4 s.15
    • /
    • pp.7-12
    • /
    • 2004
  • This study analyzed the current Urban Disaster Management System(UDMS) and proposed improvements, focusing on fire-fighting. We learned the problems with the UDMS empirically, conducting a survey intended for officials in fire station in various prefectures include big city, 6 metropolitan city and Gyeonggi-do. The problems with the UDMS were classified mainly into problems with law operating system, administration system and systematic countermeasures. As a result, it was found that regions that include Seoul and other big cities manage urban disasters better than the prefectures of which Gyeonggi-do and others are parts Consequently, it is desirable to cater appropriate Urban Disaster Management Systems into each of the two parts, one for big cities and the other for prefecture.

Prevention of Human injury and Countermeasure of evacuation about Fire of Nursing Homes by Conversion of existing buildings - Focused on rural areas in Gwangju and Jeonnam - (기존 건축물을 용도변경한 노인의료복지시설의 화재 인명피해 예방과 피난 대책 -광주·전남 농촌지역을 중심으로-)

  • Kim, Hyun-Tae;Kim, Won-Jin
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.20 no.1
    • /
    • pp.27-36
    • /
    • 2018
  • At present, the elderly population in Korea is 14% of the total population and then We has entered an the society of advanced age. Along with this, elderly people with dementia and palsy are also increasing. The demand for elderly nursing homes for elderly people with severe diseases such as dementia and stroke is also increasing, and the existing buildings are being secured by Conversion of existing buildings. However, it is difficult to evacuate and fire due to the out of date of buildings by Conversion of existing buildings. For example, there is a fire in the Indukukwon, Pohang City and Hyosung Geriatric Hospital, Jangseong in Korea, which have changed the use of existing buildings. Many elderly people died in a night fire. It was because of the sandwich panel walls and PVC flooring material produced toxic gas instantly. In this study, we investigated the nursing home that changing the use and established fire prevention of human injury and countermeasure of evacuation. First, the sandwich panels which leading to deaths due to the toxic gas were installed in most nursing home. We recommend the RC, the masonry wall, and the glass fiber panel instead of the sandwich panels, In addition, the PVC flooring is most used in nursing home, the flooring material is considered such as the building stones, the tile, and the yellow soil closing instead of the PVC flooring. Second, we investigated the installation status of fire fighting equipment. As a result, the automatic-emergency open&shut equipment, the smoke ventilator and the evacuation slide were rarely installed. In order to secure the golden time in case of fire and to prevent the asphyxia caused by the toxic gas, the law should be amended to install the equipment.

A Basic Study on the Improvement of Construction Management Engineer Placement According to Workload (업무량에 따른 건설사업관리기술자 배치개선에 관한 기초연구)

  • Lee, Taick-Oun;Lee, Kook-Hyun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.114-115
    • /
    • 2018
  • Since the introduction of the C.M(Construction Management)system in the Basic Law of the Construction Industry in 1997, the recent arrangement of construction management engineers in public sector buildings has generally been based on architecture·civilengineering·machinery·landscaping, electricity, telecommunication, fire fighting by the number of M/M(Man and Month). In the field of engineers arrangement in each field, the arrangement of M/M according to the workload of architecture.civilengineering.machinery.landscaping and electricity is inadequate causing conflicts and C.M among construction management engineers. Therefore, this study aims at basic research that is used to identify the problems through the questionnaire and to prepare future improvement plans.

  • PDF

A Study of improvement for Incident Command Systems in Korea (우리나라 재난현장지휘체계 개선방향)

  • We, Kum-Sook;Jeong, An-Young;Eum, Se-Joon
    • Journal of Korean Society of societal Security
    • /
    • v.4 no.1
    • /
    • pp.39-47
    • /
    • 2011
  • According to the current basic law of disaster and safety management, Standard Incident Command System is limited to Emergency Rescue Function, and Incident Commanders are only Fire Fighting Agencies. The main purpose of this study is to provide some suggestions to improve general-purpose of Standard ICS for various incidents. Also, there are some suggestions for Emergency Operation Centers as a coordinator and supporter of mobilizing response resources in all large scale disaster.

  • PDF

Domestic current situation and Improvement plan Consideration of Electricity Design&Supervision System (전기설계.감리제도의 국내.외 현황 및 개선방안 고찰)

  • Nam, Gi-Beom;Lee, Jong-Hyeok;Jeon, Yeong-SU;Yang, Sun-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2005.11c
    • /
    • pp.14-18
    • /
    • 2005
  • The Reason of collapse accidents, Seongsu bridge Accident in 1994 and Sampung department store Accident in 1995 and so on, that is found out to the shortage construction. Consequently, depending on orderer's self-regulating judgement the meanwhile, Electricity Technique Administration Law in 1995 owes at the public opinion to need the plan of a law system device about the electricity design and supervision and is born. This various issue problem, the combined ordering with Constructing, Electricity, fire-fighting, Information & Communication and so on, field problem, low cost services, the problem about the selection procedure of the design and supervision businessman, the business range between general and specialized, which the system appears as are carried out have been risen. Therefore basic solution plan about this have been desired. We consider a domestic current situation about an electricity design supervision system in this paper, and try to present the plan for healthy upbringing development of the electricity industry through this.

  • PDF

The Study on the Construction of Safety Management Systems on Underground Multiplex Facilites (지하 다중이용시설 안전관리 체계 구축 방안 연구)

  • Seo, Tae-Woong;Lee, Jeong-Eun;Jung, Myung-Kyun;Kim, Chang-Soo
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.165-168
    • /
    • 2008
  • Recently, the damage which is caused by human misfortune in the underground space have increased. However the regulation and law for the underground space safety is still poor. Therefore in this paper, we propose the scheme for the construction of safety management systems on underground multiplex facilities. We analyze the problem of the current law, and present the scheme for the underground shop fire fighting facility. It contains the tree structure to management the underground space according to the construction phase, the facility and immediacy equipment. This safety management system will rearrange the scattered underground space management system.

  • PDF

The Proposition of Domestic Sprinklers Installation Standard and the Fire Services Act (국내 스프링클러 설치기준과 소방관련 법에 관한 고찰)

  • Kim, Yong-Moon;Lee, Young-Jai
    • Journal of Korean Society of Disaster and Security
    • /
    • v.7 no.2
    • /
    • pp.17-24
    • /
    • 2014
  • Recently, many accidents occur frequently because sprinklers aren't installed or don't work right when there are outbreak of fire in houses and aggregate buildings. Therefore, they can result in damage for humans and loss of property. Sprinklers are the most appropriate which can extinguish buildings' fire in the initial stages. Through lack of legal system, in domestic cases, sprinklers cannot operate their inherent performance. Domestic standard simply classifies installation objects according to types of business and forms of buildings, also divides into uses and floors of buildings. Especially it only regulates that sprinklers must be installed every floors in particular fire buildings that have more than eleven floors. While it doesn't need to install sprinklers below ten floors, so we are threatened the safety. In this study, we derived causes and implications by analyzing concepts of sprinklers facilities, installation standards in domestic and foreign legal system, and recent cases that expanded damages in fire accidents because of weak point of installation and control standards. In domestic cases, as a result, government has to provide an institutional strategy and law that regulate duty to install sprinklers to all aggregate buildings regardless of floors in terms of new buildings. Also, if someone who has existing buildings wanted to install them, government would guarantee subsidy to encourage installation. In addition, government supervises fire-fighting activities when there are fire by compensating standards about regular inspection by a qualified technician, operation and maintenance of sprinklers as well as reinforcement of administrative criteria.

Design of All-in-One Descending Lifeline with Reduced Usage Time (사용시간이 단축된 일체형 완강기 설계)

  • Yun, Seul-Gi;Park, Jung-Woo;Jung, Geun-Hak;Jung, Min-Hee;Kang, Sangwook;Kim, Sang-Hyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.5
    • /
    • pp.21-26
    • /
    • 2020
  • A descending lifeline is the only self-escape fire apparatus for fire in high-rise buildings and is installed in most buildings according to fire-fighting law. However, it is difficult to properly use and quickly evacuate during an emergency due to its complex installation methods and procedures, even if users are pre-educated. In this paper, a new one-touch descending lifeline, which simplifies usage procedures and can be used regardless of whether users are educated, is proposed to solve the drawbacks of the conventional descending lifeline. All separate parts that require additional installation are initially assembled in a box, and the concept of a double square linkage is proposed to enable escape in a single motion of pushing the handle attached to the box. Three steps of kinematic design are explored to determine an appropriate configuration of double square linkage, and its dimensions are determined using Matlab and NX CAD software. The proposed all-in-one descending lifeline also follows the enforcement decree of the Fire Control Act, and its feasibility is verified through fabrication.