A Study on the Flame Extinguishing Characteristics of Inerting Gaseous Agents (불활성가스계 소화약제의 불꽃소화 특성에 관한 연구)

  • Kim, Sung-Min;Shin, Chang-Sub;Park, Jae-Man
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.148-150
    • /
    • 2008
  • Halon gas agent has been widely used as the extinguishing agent for B class and C class fires because of its excellent extinguishing power. But Halon was found to contribute to the ozone layer destruction, eventually Halon designated as one of ozone-layer-destroying materials in the Montreal Protocol in 1987, In this study, in the context of such researches, we measured the characteristics of flame concentrations of inert gaseous agents by Cup-burner method.

  • PDF

A Study on Percent Agent in Pipe as a Criterion to Evaluate Limitations and Performance of Gaseous Fire Extinguishing Systems (가스계 소화설비의 제한사항 및 성능평가를 위한 배관 내 약제비율에 관한 연구)

  • Son, Bong-Sei;Kim, Hee-Woo
    • Fire Science and Engineering
    • /
    • v.21 no.4
    • /
    • pp.1-11
    • /
    • 2007
  • This study aims to investigate, review, and summarize the definition, development, and applications of "percent agent in pipe", "percent of agent in pipe" which is used as a key factor in testing and evaluating the performance of gaseous fire extinguishing agents, including Halon 1301 and $CO_2$. This study also analyzes and compares the local and international standards on testing and evaluating the performance of gaseous fire extinguishing systems, as well as the results of system performance tests conducted as a part of performance evaluation and approval programs for gaseous fire extinguishing systems, especially, Korean Gaseous Fire Extinguishing System Performance Approval Program called KFI Approval. Percent agent in pipe was defined first in NFPA 12A, Standard on Halon 1301 Fire Extinguishing Systems, dating back to the 1970's. After the phaseout of Halon 1301 systems in 1994 in the developed countries, the percent agent in pipe has been widely used in Halon 1301 alternative clean agent fire extinguishing systems, both halocarbon clean agent systems and inert gas clean agent systems, as an essential criterion to assure the system design accuracy, determine the limitations and performance of a system, and to predict the system performance results accurately, especially, in association with their system flow calculations. Underwriters Laboratories has their own standards such as UL 2127 and 2166 applying percent agent in pipe in testing and evaluating the performance of clean agent fire extinguishing systems. As a part of a system performance test and approval program called KFI Approval System, Korea also has started to apply the percent agent in pipe as a key factor to test, evaluate, and approve the performance of gaseous fire extinguishing systems, including both high and low pressure $CO_2$ systems, from the early 2000's. This study outlines and summarizes the relevant UL and KFI standards and also describes the actual test resultant data, including the maximum percents of agent in pipe for gaseous fire extinguishing systems. As evidenced in lots of tests conducted as a part of the system performance test and approval programs like KFI Approval System, it has been proven that the percent agent in pipe may work as a key factor in testing, evaluating, and determining the limitations and performance of gaseous fire extinguishing systems, especially compared with the hydraulic flow calculations of computer design programs of gaseous fire extinguishing systems, and will remain as such in the future. As one thing to note, however, there are some difficulties in using the unified percent agent in pipe to determine the maximum lengths of pipe networks for gaseous fire extinguishing systems, because the varying definitions used by some of the flow calculations (not in accordance with NFPA 12A definition) make it impossible to do any direct comparison of pipe lengths based on percent agent in pipe.

A Study On The Development Of An Automatic Fire Extinguishing System For The Engine Compartment Use Of Automobiles (자동차 엔진 화재용 자동 소화 시스템 개발에 관한 연구)

  • Lim, Sung-Muk;Jung, Ki-Chang;Kim, Hong;Kang, Young-Goo;Lee, Chang-Sub
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.57-61
    • /
    • 1996
  • Our goal was to make a cost-effective automatic fire extinguishing system for the engine compartment use of automobiles. We designed this system for the engine compartment. This system consists of 1)foam extinguisher, 2)four nozzles, 3)a pipe arrangement, and 4)an extinguishing device which is equipped with a glass bulb as detector. First and foremost, the extinguishing device was carefully designed to keep the system cost to a minimum. Second, a AFFF foam extinguisher was used because no other fire-fighting agents proved effective against fire in the engine compartment. The AFFF(Aqueous Film Forming Foam) agent which was used in the extinguisher is the 3M company's Light Water. We sought, however, to make other foams by using Halon 1301 and Halon alternatives such as HCFC Blend A, HFC-227ea. We selected these alternatives instead of air in order to raise the expansion ratio of the AFFF agent. By these means we discovered that it is possible to increase the expansion ration of the AFFF agent up to 44:1. We then demonstrated that our automatic fire extinguishing system is the most effective and lowest cost-system yet devised for passenger cars.

  • PDF

A Study on Clean Agents for Halon Replacement in the Portable Extinguisher with CO2 as an Expellant Gas (이산화탄소를 가압원으로 하는 할론대체 소화기용 청정소화약제에 대한 연구)

  • Jeong, Keesin
    • Fire Science and Engineering
    • /
    • v.33 no.3
    • /
    • pp.51-55
    • /
    • 2019
  • To prevent ozone depletion caused by CFCs, the replacement of Halon with clean agents has been developed in the fire protection field along with refrigerants, detergents, and foaming agents. The alternatives for Halon 1211 have been developed in the portable fire extinguisher area and HCFC-123 is used widely as a clean fire extinguishing agent. The type of expellant gas is important because their own vapor pressure is low. In this study, HCFC-123, HCFC-124, HFC-125, and Novec-1230 were selected as fire extinguishing agents and CO2, which is expected to improve the fire extinguishing ability, was chosen as the expellant gas. For each agent, experiments changing the agent and CO2 amount were carried out and HCFC-123 showed a good result, as expected. The extinguisher, HCFC-123 of 1.5 kg, showed the same ability to suppress a class A and B fire as the extinguisher, HCFC-123 of 2.5 kg, which is currently sold on the market. According to this result, the expellant gas has a subsidiary fire extinguish effect. This can reduce the amount of HCFC fire extinguishing agent, which is categorized in the phase-out alternatives, and is a more eco-friendly and economical fire extinguisher than the previous one. This study can also help solve the problems of CO2 fire extinguishers for class B and C fires, and can be used to extinguish electric and electron facilities fire, which contains large amounts of class A fire combustibles.

Wetting Agent Performance Evaluation Using Scale Model (축소모형 실험을 통한 침윤소화약제 소화성능 평가)

  • Kim, Nam-Kyun;Lim, Kyung-Bum;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.28 no.2
    • /
    • pp.20-25
    • /
    • 2014
  • In this study, the extinguishing performance evaluation of wetting agent for wood crib was conducted by using a scale model equipment that we designed. To confirm the optimal conditions of the experiment, a test was changed amount of fire extinguishing water and the number of timber. As a result, the discrimination of the fire extinguishing performance was seen only when 20 pieces of wood and the extinguishing water of 100 mL were used. After evaluating the extinguishing performance of domestic and foreign wetting extinguishing agents under these conditions, a reignition was occurred in only when we used water. In addition, the discrimination of extinguishing performance was seen through the temperature distribution according to the time of watering. Based on the results of this experiment, this study is expected to be able to use as a basis on presenting a method of optimized performance evaluation of wetting extinguishing agent.

Example of Air Exposure Assessment for Fire Extinguishing Agent Residues (소화약제 잔류물질에 대한 공기 중 노출평가 사례)

  • Daesung Lim
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.34 no.1
    • /
    • pp.14-17
    • /
    • 2024
  • Objectives: This is a case of air exposure assessment conducted after researchers complained of headaches and odor due to residual substances from fire extinguishing agents spread throughout the laboratory due to a malfunction of the fire extinguishing facility. Methods: A component analysis was conducted on the residual substances of a fire extinguishing agent spread in a laboratory using Py-GC-MS (pyrolysis gas chromatography mass spectrometry) at the research institute's own central equipment research center. As a result of the component analysis, several types of substances were detected. Among these, five types of substances subject to work environment measurement in the aromatic hydrocarbon series, which can affect headaches and odor, were selected as substances subject to exposure assessment in the air, and the measurement and analysis methods of the target substances were conducted in accordance with the KOSHA Guide for each substance. Conclusions: The measurement results showed that all 5 types of substances were not detected at locations A, B, and C. This is believed to be the result of the residual substances in the fire extinguishing agent being measured when approximately two months had elapsed after being exposed to the test bench, and the substances already exposed had volatilized and disappeared. In this survey, it is believed that the measurement process is more important than the measurement results.

Risk Assessment of exposure to the extinguishing agents using CHARM (CHARM을 통한 소화약제 위험성 평가에 관한 연구)

  • Cho, Jung Rae;Jung, Tae Hwan
    • Journal of Korean Society of Disaster and Security
    • /
    • v.10 no.2
    • /
    • pp.35-41
    • /
    • 2017
  • Recently chemical intoxication related with the use of chemical extinguishing agents occurs frequently. With the industrialization, high-rising of building and increase of fire risk, we use the various extinguishing agents and the safe use become important. In this study I carried out the risk assessment of representative chemical extinguishing agents (HCFC-123, HFC-125) using the CHARM and got the meaningful qualitative outcome. This study is significant in that the risk assessment of chemicals was conducted using CHARM, chemical risk assessment tool. It is expected that the results will be utilized as the basic data for the national chemical safety management.

Halon 규제에 대한 대응 방안

  • Kim, Yeong-Bae
    • Fire Protection Technology
    • /
    • s.10
    • /
    • pp.13-18
    • /
    • 1991
  • It seems that the use of one of the major fire-fighting agents-halon-is going to be denied to the fire protection community at the end of the century. It is now being widely accepted that the CFC and halons released into the atomosphere are contributing to both the depletion of the ozone layer green house effect. Therefore, we should research to determine suitable alternative(gaseous) fire extinguishings agents to the halons and improve or develop other extinguishing systems.

  • PDF

The Development of an Environmental-Friendly Foam Extinguisher Using a Natural Surfactant (천연계면활성제를 이용한 친환경적 포소화약제 개발)

  • Kim, Jeong-Hun;Lee, Jung-Yun;Kim, Hong;Kim, Eung-Sik;Lee, Myoung-Bo;Kim, Dong-Hyun;Jung, Ki-Chang
    • Fire Science and Engineering
    • /
    • v.21 no.1 s.65
    • /
    • pp.69-73
    • /
    • 2007
  • In this research, an environmental-friendly foam extinguisher was newly developed using a natural surfactant as its composition. Two criteria were applied to verify its extinguishing performance and environmental attraction. One is unit 2 model by "Standards of Model Approval and Inspection Technology for Portable Fire Extinguishers" presented in Korea Fire Equipment Inspection Corporation. The other is Terrestrial Plants, Growth Test and Fish, Acute Toxicity Test presented in Korea Institute of Toxicology(Korea Research Institute of Chemical Technology). Test results showed that the extinguishing performance was 5 unit of general fire Class A, the $LC_{50}$ by germination was 75(g/kg) and the $EC_{50}$ by growth was 62(g/kg) through Terrestrial Plants, Growth Test, and also the toxicity was 6658 ppm in Fish, Acute Toxicity Test. The numerical values were highly evaluated than other fire extinguishing agents being commercialized in domestic. The results also showed suitably in basic physical properties and anti-corrosion properties for making use of fire extinguishing agent.

SOLUBILITY OF NITROGEN IN CLEAN EIRE EXTINGUISHING AGENTS AT HIGH PRESSURE

  • Kim, Jae-Duck;Lim, Jong-Sung;Lee, Youn-Woo;Lee, Youn-Yong
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.534-541
    • /
    • 1997
  • Isothermal solubilities of nitrogen in clean fire extinguishing agents, such as bromotrifluoromethane (Halon-1301), bromochlorodifluoromethane (Halon-121 t), 1,1,1,2,3,3,3- heptafluoropropane (HFC-227ea), and trifluoroiodomethane (FIC-13I1) were measured in a circulation-type equilibrium apparatus. The temperature range was (293.2 to 313.2) K and the pressure range was (30 to 100) bar. The experimental data were well correlated with the Peng- Robinson equation of state using the Wong and Sandier mixing rules, and the relevant parameters are presented.

  • PDF