• Title/Summary/Keyword: Fire Extinguishers

Search Result 46, Processing Time 0.029 seconds

Simulation of Wood Crib Burning Behaviors by Using FDS (FDS를 이용한 소화모형 화재거동의 시뮬레이션)

  • Kwon, Seong-Pil;Yoon, Hun-Ju;Kim, Hyeong-Gweon;Ra, Yong-Woon;SaKong, Seong-Ho;Shin, Dong-Il
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.76-79
    • /
    • 2008
  • In this work wood crib burning behaviors have been simulated by using the FDS(Fire Dynamic Simulator) program. Wood cribs are regularly stacked arrays of wood sticks, and available for the performance rating of fire-extinguishers. On the basis of an angle iron supporter 26 layers of wood sticks have been stacked up. Each layer consists of 5 or 6 wood sticks which are placed in parallel, with a constant distance, and in alternating rows. They are laid between the horizontally adjacent sticks at the before last layer. The wood crib is ignited instantaneously by an amount of burning gasoline below. A comprehensive simulation of such a practical sophisticated combustion is still too difficult to realize with any currently available computer, although the performance of modern processors is getting better everyday. We could carry it out here through parallel computing on the HPC(High Performance Computing) cluster as the feasible alternative. At last the validation has been executed by means of temperature distribution data measured by the thermal video camera.

  • PDF

A Study on the Development of a Fire Extinguishing Agent Leakage Monitoring Module and its Performance Assessment (소화약제 누기 감시장치의 모듈개발 및 성능검증에 관한 연구)

  • Son, Bong-Sei;Hong, Sung-Ho;Go, A-Ra
    • Fire Science and Engineering
    • /
    • v.30 no.2
    • /
    • pp.43-48
    • /
    • 2016
  • One of the main problems with gaseous fire extinguishers is the decrease in fire suppression capability due to the leakage of the fire extinguishing agents, either naturally or caused by obsolete equipment. Therefore, in this study, a real-time detector module for monitoring pressure leakages was developed and an assessment on its performance was carried out. Currently, there are no domestic or global standards for testing pressure leakage detection systems. Therefore, similar global standards, such as ISO 7240 and FM 1421, and the domestic law on "Receiver type-approval and technical standards for product inspection" were used as a reference for assessing the performance of the newly developed module. Its basic performance was assessed by applying compressed air to the module, and, as a result, the minimum working pressure was identified as 0.3 bar. Its environmental qualification was carried out to confirm the proper functioning of the module in different climates and the module was confirmed to function properly at both high ($50^{\circ}C$) and low ($-10^{\circ}C$) temperatures.

The Development of an Environmental-Friendly Foam Extinguisher Using a Natural Surfactant (천연계면활성제를 이용한 친환경적 포소화약제 개발)

  • Kim, Jeong-Hun;Lee, Jung-Yun;Kim, Hong;Kim, Eung-Sik;Lee, Myoung-Bo;Kim, Dong-Hyun;Jung, Ki-Chang
    • Fire Science and Engineering
    • /
    • v.21 no.1 s.65
    • /
    • pp.69-73
    • /
    • 2007
  • In this research, an environmental-friendly foam extinguisher was newly developed using a natural surfactant as its composition. Two criteria were applied to verify its extinguishing performance and environmental attraction. One is unit 2 model by "Standards of Model Approval and Inspection Technology for Portable Fire Extinguishers" presented in Korea Fire Equipment Inspection Corporation. The other is Terrestrial Plants, Growth Test and Fish, Acute Toxicity Test presented in Korea Institute of Toxicology(Korea Research Institute of Chemical Technology). Test results showed that the extinguishing performance was 5 unit of general fire Class A, the $LC_{50}$ by germination was 75(g/kg) and the $EC_{50}$ by growth was 62(g/kg) through Terrestrial Plants, Growth Test, and also the toxicity was 6658 ppm in Fish, Acute Toxicity Test. The numerical values were highly evaluated than other fire extinguishing agents being commercialized in domestic. The results also showed suitably in basic physical properties and anti-corrosion properties for making use of fire extinguishing agent.

Development of Fire Extinguisher Valves for Tracked Vehicle Using Novec1230 (친환경 소화약제 Novec1230을 적용하는 궤도차량용 소화기밸브 개발)

  • Kim, Jong-Ryeol;Ku, Hak-Keun;Oh, Sang-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.4
    • /
    • pp.1539-1546
    • /
    • 2011
  • Halon which is one of the typical fire extinguishing agents for special purposes was banned not only to use but to manufacture because it destroys the earth's ozone layer. There have been many efforts to find or create Halon alternatives and Novec1230 which is one of the eco-friendly fire extinguishing agents is nominated. In this paper 6 kinds of valve structures were suggested to apply Novec1230 to fire extinguishing agents for railroad vehicles as Novec1230 needs different valve specifications from Halon and spray shapes and action time were compared and measured. As the results, the extinguishing times of A type and F type valves are 20% faster than the other 4 types, and 178% faster than MIL-DTL-62547(USA). Therefore, they can be suggested to the eco-friendly extinguishing agents and Novec1230.

A Study on Clean Agents for Halon Replacement in the Portable Extinguisher with CO2 as an Expellant Gas (이산화탄소를 가압원으로 하는 할론대체 소화기용 청정소화약제에 대한 연구)

  • Jeong, Keesin
    • Fire Science and Engineering
    • /
    • v.33 no.3
    • /
    • pp.51-55
    • /
    • 2019
  • To prevent ozone depletion caused by CFCs, the replacement of Halon with clean agents has been developed in the fire protection field along with refrigerants, detergents, and foaming agents. The alternatives for Halon 1211 have been developed in the portable fire extinguisher area and HCFC-123 is used widely as a clean fire extinguishing agent. The type of expellant gas is important because their own vapor pressure is low. In this study, HCFC-123, HCFC-124, HFC-125, and Novec-1230 were selected as fire extinguishing agents and CO2, which is expected to improve the fire extinguishing ability, was chosen as the expellant gas. For each agent, experiments changing the agent and CO2 amount were carried out and HCFC-123 showed a good result, as expected. The extinguisher, HCFC-123 of 1.5 kg, showed the same ability to suppress a class A and B fire as the extinguisher, HCFC-123 of 2.5 kg, which is currently sold on the market. According to this result, the expellant gas has a subsidiary fire extinguish effect. This can reduce the amount of HCFC fire extinguishing agent, which is categorized in the phase-out alternatives, and is a more eco-friendly and economical fire extinguisher than the previous one. This study can also help solve the problems of CO2 fire extinguishers for class B and C fires, and can be used to extinguish electric and electron facilities fire, which contains large amounts of class A fire combustibles.

Legal Aspects on ICAO SARPs Regarding Alternative Fire Extinguishing Agent to Halon Fire Extinguishers

  • Lee, Gun-young;Kang, Woo-Jung
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.33 no.1
    • /
    • pp.205-226
    • /
    • 2018
  • For sustainable development of air transport, the establishment and application of international standards of environmental protection area is significant. The development and use of alternative fire extinguishing agent to Halon, which is used for the fire extinguishing systems of engine nacelles/APU and cargo compartments, has been requested in order to protect the ozone layer. The ICAO has been active in preparing international standards and recommended practices (SARPs); however, certification of alternative fire extinguishing agents has been postponed due to technical readiness problem.. Consequently, the implementation of SARPs has also been postponed by two years from the end of 2016. to the end of 2018. As such consequences have caused confusion among Member States regarding its implementation, it is necessary to discuss and pay more attention to this issue. ICAO Council and Air Navigation Commission should consider between setting the implementation time frame earlier or giving enough time for mature readiness and preparedness. Also in order to minimize the unnecessary discharge of Halon owned by Member States, it is necessary to consider efficient management methodologies; for example, requesting fire extinguisher manufacturers to recharge in professional ways. For the successful implementation of the SARPs, ICAO developed an implementation task list as including notification of differences, establishment of a national implementation plan, drafting of the modification to the national regulations and means of compliance, adoption of the national regulations and means of compliance. Member States can develop their own rule making process in reference with the ICAO implementation task list. This issue was presented and discussed during the 54th Conference of Directors General of civil aviation, Asia and Pacific Regions which was held in Ulaanbaatar, Mongolia in 2017 with significant attention among participated Contacting States. In this regards, ICAO Council and Air Navigation Commission should consult with Legal Bureau lawyers regarding SARPs preparing process to eliminate difficulties and confusions for proper implementation within effective date.

A Numerical Study to Analyze Safety of Pressure Leakage Monitoring System of Gas Extinguishing Agent (가스소화약제 압력누기감시장치의 안전성 분석을 위한 수치적 연구)

  • Go, A-Ra;Lim, Dong-Oh;Son, Bong-Sei
    • Fire Science and Engineering
    • /
    • v.30 no.4
    • /
    • pp.103-110
    • /
    • 2016
  • While the demand for the gas system fire extinguishers increases every year, there are insufficient safety measures for assessing the extinguishing performance, such as system safety and reliability in the preparation of increasing demand, which has emerged as a social problem. One of the most critical causes of accidents occurring with the gas extinguishing system is pressure leakage from the extinguishing agent storage container. This is considered to be one of the critical factors on which the success of fire suppression depends. In this study, its safety measure was studied, Because it was deemed urgently necessary. The newly developed pressure leakage monitoring system is a system monitoring storage condition, pressure, leakage and discharge of the storage container related to agent concentration, which is one of the critical factors for fire suppression. This was developed to be applicable to the $CO_2$ and HFC-23 systems. Therefore, for structural safety analysis, the safety performance was verified by the fluid structure coupling analysis of the safety problems that may occur when the pressure leakage monitoring system is applied to the gas fire extinguisher. For analysis programs, the FloEFD program from Mentor Graphics was used for computational fluid dynamics analysis and ABAQUS from Dassault Systems was used for structural analysis. From the result of numerical analysis, the structure of $CO_2$ did not develop plastic deformation and its safety was verified. However, plastic deformation and deviation issue occurred with the HFC-23 monitoring system and therefore verified the structural safety of pressure leakage monitoring system by data obtained from redesigning and adjusting the condition of numerical interpretation three times.

Analysis of Ambivalence Differences among Groups for Temporary Firefighting Facilities of Workers at Construction Sites (공사현장 근로자의 임시소방시설에 대한 집단 간 Ambivalence 차이분석)

  • Moon, Pil-Jae;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.4
    • /
    • pp.765-778
    • /
    • 2021
  • The purpose of this study is to prevent fire accidents in advance by deriving prior knowledge among groups about temporary fire-fighting facilities of workers at construction sites and devising appropriate improvement measures. The findings are as follows.First, in the case of fire extinguishers, statistical attention was paid to the contractor, supervisor, partner worker and fire extinguisher manager between designations. 87% of fire managers and 70% of facility supervisors said fire extinguisher management managers needed to be designated for each type of construction, which requires designation of fire extinguisher management managers, frequently checking and relocating. Second, in the case of simple fire extinguishing facilities, statistical attention was paid to the application of penalties for unauthorized use of fire extinguishing facilities with construction companies, supervisors, and business partners.Third, in the case of emergency alarm measures, statistical attention was paid to the application of emergency alarm sound to temporary broadcasting facilities with construction works, supervisors, and business partners.Fourth, in the case of induction, statistical attention was paid to the application of connection between construction works, supervisors, and partner workers, such as passage guidance, emergency lighting, etc.It was found that 65% of construction workers and 55% of electrical workers had different applications such as aisle guidance and emergency lighting for each type of business partner. In order to resolve blind spots such as evacuation zone guidance due to the structure of the building, it is necessary to easily distinguish the direction of the entrance door from a long distance by applying it in conjunction with passage guidance lights and emergency lighting.

Design of Simulation Environment for Intelligent Disaster Prevention System and Implementation of Management Application (지능형 방재 시스템 시뮬레이션 환경 및 관리 어플리케이션 구현)

  • Cho, Young-Ho;Kang, Heau-Jo;Sung, Kyung
    • Journal of Advanced Navigation Technology
    • /
    • v.15 no.4
    • /
    • pp.602-608
    • /
    • 2011
  • In this paper, we implemented an android mobile management application of intelligent prevention of disaster system which can manage the current status monitoring and whether operating or not by using Ubiquitous Sensor Network based self wireless communication system of scattered emergency light, fire extinguishers and sprinkler inside the high complex building. This system is composed with fire facilities attached sensor nodes, management server for collection of information and control, and smart phone application that transmits and receives information with management server. As a result of the test, the embodied android-based smart phone application to be performed anywhere could confirm status and monitoring information of fire facilities which are communicated with the management server.

A Study On The Application Of Foam Extinfuishing Agent By Using Halon 1301 And Halon Alternatives (Halon 1301과 Halon 대체 소화약제를 기포제로 이용한 포 소화약제에 대한 연구)

  • Jung, Ki-Chnag;Lim, Sung-Muk;Lee, Chang-Sub;Kang, Young-Goo;Kim, Hong
    • Fire Science and Engineering
    • /
    • v.10 no.3
    • /
    • pp.29-40
    • /
    • 1996
  • The AFFF(Aqueous Film Forming Foam : 3M Company's Light Water) agent are synthetic compounds that foams which are similar to those produced by protein based materials. The foam extinguishing agent was used In the extinguisher was the AFFF agent. We sought, however, to make other foams by using halon 1301 (CF$_3$Br) and halon alternatives, such as HCFC Blend A($CHCIF_2$ 82%, $CF_3$CHCIF 9.5%m $C_{10}$$H_{16}$ 3.75%), HFC-227ea ($CF_3$ $CHFCF_3$) We selected these alternatives instead of air in order to raise the expansion ratio of the AFFF agent. By these means we discovered that it is possible to increase the expansion ratio of the AFFF agent up to 44:1 and up to 24:1 when HFC-227ea was used as a halon alternatives. Therefore our new foam extinguishing agents can be used in a portable extinguish agents can be used in a portable extinguishers.

  • PDF