FDS 열분해 모델을 이용한 콘칼로리미터(ISO 5660) 화재 시뮬레이션 (Fire Simulation by Pyrolysis Method of FDS for the Small Cone Calorimeter (ISO 5660))

  • 양성진;장정훈;강찬용
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.206-212
    • /
    • 2009
  • Chemical behaviors of each surface material for interior facilities affect to fire initiation and growth in general fire situation. These chemical behaviors were characterized by thermal properties (Heat release rate, Pyrolysis rate, specific heat, etc) which could be derived from experimental test. Especially, Heat release rate which indicates aspect of fire size is one of the most important property to asses fire hazard and protection needs. The cone calorimeter test (ISO 5660) has recently assumed to a dominant role in bench scale fire testing to obtain the Heat release rate of materials. This value could be calculated by the 'Oxygen Consumption Method' under various producing irradiances to each surface of materials. In this study, Process of the cone calorimeter test was simulated by Pyrolysis model of FDS (Fire Dynamics Simulator by NIST) base on the ISO 5660 international standard. Then, we could estimate the simulation method of FDS in case of single materials through the comparative study with test results.

  • PDF

철도차량 안전기준을 만족하는 철도차량 내장재의 화재성능 시험 (Fire test for interior material satisfied with the guide for the safety of rail vehicle)

  • 박원희;이덕희;정우성
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2149-2153
    • /
    • 2008
  • A large-scale fire test was done for interior materials from a vehicle installed within a fire test room. The interior materials are satisfied with the Korean guide for the safety of rail vehicle. The guide has taken effect since December 2004 in Korea. Ignition source (gas burner) was increased in several controlled steps. The objectives of this test are to assess the fire performance in terms of ignition and flame spread on interior lining materials and to provide data on an enclosure fires involving train interior materials that grow to flashover. This data will be used to develop and calibrate an Fire Dynamics Simulator (FDS) model for fire growth on the interior vehicle.

  • PDF

화재모델링을 위한 정온식 열감지기의 장치물성 측정 (Measurement of the Device Properties of Fixed Temperature Heat Detectors for the Fire Modeling)

  • 박희원;조재호;문선여;박충화;황철홍;김성찬;남동군
    • 한국화재소방학회논문지
    • /
    • 제28권1호
    • /
    • pp.37-43
    • /
    • 2014
  • 성능위주 소방설계(PBD)의 과정에서 화재 및 피난모델링의 신뢰성을 확보하기 위해서는 화재감지기 모델의 높은 예측성능이 필수적으로 요구된다. 본 연구의 목적은 대표적인 화재모델인 FDS에 적용되고 있는 정온식 열감지기의 정확한 작동 개시시간을 예측하기 위한 입력정보를 측정하는 것이다. 이를 위해 화재감지기의 장치특성을 측정할 수 있는 Fire Detector Evaluator (FED)가 사용되었으며, 국내에서 적용되는 2개의 써미스터 방식(Thermistor types)과 1개의 바이메탈 방식(Bimetal type)의 스포트형 정온식 열감지기가 연구대상으로 고려되었다. 화재모델링을 위해 요구되는 감지기의 작동 개시온도 및 반응시간지수(Response Time Index)가 측정되었으며, 이때 RTI는 감지기의 설치위치를 고려하여 천장제트기류(Ceiling jet flow)와 수직제트기류(Vertical jet flow)에 대하여 측정되었다. 측정된 장치물성을 이용한 화재모델링 결과는 실규모 구획화재실험 결과와 비교 검증되었다. 그 결과 수치적으로 예측된 감지기의 작동 개시시간은 실험결과를 적절히 잘 예측함을 확인하였다.

공연장 화재 축소모형의 전산시뮬레이션을 통한 방화막 영향 예측 (Prediction of the Fire Curtain Effect through a Numerical Simulation of a Reduced Scale Model for Fires in Theaters)

  • 김동환;이치영;김동균
    • 한국화재소방학회논문지
    • /
    • 제32권3호
    • /
    • pp.51-59
    • /
    • 2018
  • 공연장 화재 시 방화막이 객석공간으로의 연기 확산을 억제하는데 중요한 역할을 할 수 있음에도 불구하고 이에 대한 연구가 미흡한 실정이다. 본 연구에서는 전산시뮬레이션의 신뢰성을 확인하기 위하여 기존 축소모형실험에 대해 전산시뮬레이션을 수행하고 결과를 비교하였으며, 해당 전산시뮬레이션을 이용하여 방화막의 영향을 예측하였다. Fire Dynamics Simulator (FDS)를 이용하였고, 자연배출구 크기는 무대공간 바닥면적의 ~10%, ~5%, ~1%로 설정하였다. 연기 거동을 가시화하고 질량 유량 및 온도 등을 측정하고 분석하였다. 실규모 공연장 화재에서의 방화막 영향을 예측하기 위하여 상사법칙을 활용하였다. 방화막이 없을 때 본 전산시뮬레이션 결과는 기존 축소모형실험 결과와 비교적 잘 일치하였다. 한편, 실규모 공연장 화재 시, 방화막은 자연배출구 및 프로시니엄 개구부를 통한 질량 유량 및 객석공간으로 soot 유출이 일어나는 시점에 지대한 영향을 미치는 것으로 나타났다. 본 연구 결과는 방화막 개발을 위한 기초 자료로 활용될 수 있을 것으로 판단된다.

주거형 빌딩의 층간 화염전이 화재해석 모델링 (A STUDY FOR FIRE EXTENSION MECHANISM BETWEEN FLOORS IN A RESIDENTIAL BUILDING WITH NUMERICAL MODELING)

  • 안찬솔
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2011년 춘계학술대회논문집
    • /
    • pp.512-517
    • /
    • 2011
  • This study is intended for validation of numerical modeling of a residential building which is made to simulate a phenomenon of fire extension from floor to floor. A common residential building which has the area of 80m2 each floor and some combustibles were chosen for numerical modeling. The combustible models were verified through comparing results of numerical simulations and real fire tests. For computational analysis, the Fire Dynamics Simulator was used with Large Eddy Simulation model for turbulence. Consequently, fire-intensity was well predicted and flash-over of rooms were successfully estimated.

  • PDF

룸코너 설비를 이용한 내장재 교체 전 철도차량의 화재성능 시험 (Fire Test for the railway vehicle before interior replacement in Room Corner)

  • 이덕희;박원희;정우성;이동찬
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.590-595
    • /
    • 2008
  • A large-scale fire test was done for interior materials from a vehicle installed within a fire test room. The interior materials are the old style before interior replacement by the Korean guideline for the safety of rail vehicle. Ignition source (gas burner) was increased in several controlled steps. The objectives of this test are to assess the fire performance in terms of ignition and flame spread on interior lining materials and to provide data on an enclosure fires involving train interior materials that grow to flashover. This data will be used to develop and calibrate an Fire Dynamics Simulator (FDS) model for fire growth on the interior vehicle.

  • PDF

노후 아파트 화재 시 직통계단의 방화문 설치 여부에 따른 위험성 분석 (Risk Analysis According to the Installation of Fire Doors on Direct Stairs in the Event of a Fire in an Old Apartment)

  • 이상임;공하성
    • 문화기술의 융합
    • /
    • 제7권4호
    • /
    • pp.869-878
    • /
    • 2021
  • 이 연구는 2003년 12월 30일 사업승인을 받은 11층 이하의 건축관계법령이 소급 적용되지 않는 노후된 아파트가 연구 대상이며, 화재 시 인명피해가 증가되고 있는 11층 이하의 아파트에 대해 Fire Dynamics Simulator(FDS) 프로그램을 통해 위험성을 분석한 연구이다. 직통계단 입구에 방화문이 미설치된 기존 상황을 기본시나리오1로 방화문이 설치된 것으로 가정한 개선시나리오2~4의 방화문 설치 여부에 따른 위험성 분석 결과, 기본시나리오1은 연기확산으로 인한 직통계단 입구까지의 가시거리는 260초로 나타났다. 방화문이 설치된 개선시나리오3~4는 화재를 인지한 뒤 300초 후에 개방되고 직통계단 입구에 30분 방화문이 설치된 경우 직통계단 입구까지의 가시거리는 600초 한계미도달로 나타났다. 이 경우 가시거리는 방화문 설치 시 600초로 시나리오1에 비해 시나리오 3~4는 56.6% 증가되어 피난 위험성이 50%이상 낮아지는 것으로 나타났다. 연기확산의 위험성을 증가시키는 직통계단 미설치의 위험성을 제거하기 위해 법 개정을 통해 소방법령과 같이 건축관련법령이 소급 적용되어 직통계단 입구에 방화문을 설치하거나 발코니의 접이식 피난시스템 등 동등이상의 성능을 가진 시설물을 설치해야 한다. 방화문 설치에 따른 개선으로 피난시 방화문의 필요성을 수치적으로 증명하였고 방화문은 폐쇄 상태로의 유지에 대한 중요성을 파악할 수 있다.

화재시뮬레이션(FDS)을 이용한 Double Skin 연소확대 위험에 관한 고찰 (Analysis for Fire Spread through Double Skin Facade System with FDS)

  • 허윤택;박창복;성준식;윤명오
    • 한국화재소방학회논문지
    • /
    • 제23권5호
    • /
    • pp.110-116
    • /
    • 2009
  • 본 연구는 Double Skin System의 화재 전파 위험성을 전산유체역학모델인 FDS를 이용하여 평가하였다. 화재모델링을 구현하기 위해 오피스 용도의 단위 구획공간을 화재지역으로 선정하였으며, 화재시나리오는 외창으로의 연소확대 위험 분석을 위하여 일반적으로 많이 설치되는 시스템조건들을 Case로 선정하여 분석하였다. 본 연구의 목적은 일반적으로 많이 사용되는 Double Skin System의 설치 간격에 따른 건물상층부로의 화재확대 위험성을 평가하고, 이에 따른 방화대책 등을 수립하는데 있다. 해석 결과, 더블스킨 중간층 간격이 넓을수록 상부층으로 연소확대 영향이 작은 것을 확인할 수 있었으며, 중간층 간격이 1m 미만인 경우는 발화층 상부 2개층으로 연소확대가 예상되므로 층간연소 확대 방지 시스템이 요구됨을 알 수 있다.

공연장 화재 축소모형을 이용한 전산시뮬레이션 검토: 방화막 및 무대부 자연배출구 영향 (Examination on Numerical Simulation Using Reduced-scale Model of Theater Fire: Influences of Fire Curtain and Stage Natural Vent)

  • 양지현;백선아;이치영;김동균
    • 한국화재소방학회논문지
    • /
    • 제33권5호
    • /
    • pp.37-47
    • /
    • 2019
  • 본 연구에서는 Fire Dynamics Simulator (FDS)를 이용한 공연장 화재 축소모형 전산시뮬레이션(Numerical simulation)을 통해 공연장 화재 시 방화막 설치 여부 및 무대부 자연배출구 개폐 영향을 검토하였다. 기존의 축소모형 실험 연구를 바탕으로, 실존하는 공연장에 대해 상사법칙을 적용하여 1/14 비율로 축소하여 설정한 축소모형 및 조건을 대상으로 하였다. 축소모형 전산시뮬레이션을 통해 연기 유동을 가시화하고, 무대부 및 객석부 온도, 자연배출구를 통한 유출 질량 유량, 객석부로의 연기 유출 시작 시점을 측정하고 분석하였다. 전반적으로, 본 전산시뮬레이션에서 예측된 방화막 설치 여부 및 무대부 자연배출구 개폐 영향에 대한 일반적인 경향은 기존 축소모형 실험에서와 유사한 것으로 나타났다. 본 전산시뮬레이션 결과와 기존 축소모형 실험 결과 간 정량적인 비교를 위해 무대부 및 객석부 온도, 자연배출구를 통한 유출 질량 유량에 대해 평균 백분율 오차를 계산하였고, 본 전산시뮬레이션 결과와 기존 축소모형 실험 결과가 비교적 일치함을 확인하였다.

백드래프트 현상의 LES를 위한 EDC 모델의 연소 화학반응기구 적합성 연구 (A Study of the Suitability of Combustion Chemistry in the EDC Model for the LES of Backdraft)

  • 디네쉬 마일사미;오창보;한용식;도규형
    • 한국화재소방학회논문지
    • /
    • 제31권4호
    • /
    • pp.35-42
    • /
    • 2017
  • 구획실 내부의 고온 메탄연료에서 발생하는 백드래프트 현상에 대해 FDS v6를 이용한 LES를 수행하였다. EDC 연소모델을 적용하였고 여기 필요한 화학반응기구에 대해서는 5가지를 검토하여 백드래프트에 대한 예측성능을 검토하였다. 구획실 내, 외부의 온도, 연료, 속도 및 압력분포에 대한 수치계산 결과고찰과 실험에서 얻어진 압력변화와의 비교를 수행하였다. FDS v6에서 기본적으로 제공하는 EDC 연소모델을 적용하면 LES 기법을 이용하여 백드래프트에 대한 수치계산이 가능함을 확인하였다. 그러나, 결합되는 화학반응기구에 따라서 백드래프트에 대한 예측성능이 큰 차이를 보였다. FDS에서 EDC 연소모델을 적용하여 백드래프트에 대한 LES를 수행할 경우에는 연료특성에 맞는 화학반응기구의 적합성을 우선 검토하는 것이 필요함을 확인하였다.