• Title/Summary/Keyword: Fire Detection

Search Result 640, Processing Time 0.034 seconds

Algorithm for Detection of Fire Smoke in a Video Based on Wavelet Energy Slope Fitting

  • Zhang, Yi;Wang, Haifeng;Fan, Xin
    • Journal of Information Processing Systems
    • /
    • v.16 no.3
    • /
    • pp.557-571
    • /
    • 2020
  • The existing methods for detection of fire smoke in a video easily lead to misjudgment of cloud, fog and moving distractors, such as a moving person, a moving vehicle and other non-smoke moving objects. Therefore, an algorithm for detection of fire smoke in a video based on wavelet energy slope fitting is proposed in this paper. The change in wavelet energy of the moving target foreground is used as the basis, and a time window of 40 continuous frames is set to fit the wavelet energy slope of the suspected area in every 20 frames, thus establishing a wavelet-energy-based smoke judgment criterion. The experimental data show that the algorithm described in this paper not only can detect smoke more quickly and more accurately, but also can effectively avoid the distraction of cloud, fog and moving object and prevent false alarm.

Design and Implementation of a Multi-purpose Test Equipment with a Large Utilization Range for use in Electric Fire (전기화재 분야에서 다목적으로 시험장치의 활용범위를 증가시키기 위한 시험장치의 설계 및 구현)

  • Dongcheol Shin;Hyoungho Ko
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.3
    • /
    • pp.180-186
    • /
    • 2023
  • Test devices can perform various functions, such as research on detection targets, sensors that detect detection targets, combined products containing sensors, and certification for the launch of combined products. However, the scope of use of test devices is limited because they perform only a single role or could only serve a particular purpose in the past. Therefore, studies on test devices that can perform various functions, such as research on detection targets, sensors that detect detection targets, combined products containing sensors, and certification for the release of combined products are necessary. Accordingly, this study proposes a test device that can increase the scope of use in the technical field of electric fires. In addition, we examine various outcomes of the proposed test device.

Analysis of Optical Properties of Fire Smoke and Non-fire Smoke for Reduction of Nuisance Alarm (장애경보 방지를 위한 연소 연기입자와 비연소 연기입자의 광 특성 분석)

  • Jee, Seung-Wook
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.10
    • /
    • pp.49-55
    • /
    • 2014
  • This paper is basic study for development of an advanced photoelectric type smoke detector that has high reliability by reducing the occurrence of nuisance alarms. This paper was attempted to distinguish optical characteristics of the typical fire smoke particle and non-fire smoke particle. According to UL 268 standards, three types of test fires (the paper, the wood and the flammable liquid) were used in this paper for measurement of the fire smoke particles, and the water vapor and the cigarette smoke that were known as the main cause of the nuisance alarms were also used for the non-fire smoke particles. A smoke detection chamber was created, which was equipped with one light source and several light sensors for enabling simultaneous detection of light extinction and scattering, respectively. This paper analyzes the optical characteristics of each smoke particle using this chamber.

Application Studies for Active Fire Monitoring over Korea Using MODIS Direct Broadcast Data

  • Song J.H.;Kim Y.S.
    • Proceedings of the KSRS Conference
    • /
    • 2004.10a
    • /
    • pp.410-414
    • /
    • 2004
  • The MODIS Land Rapid Response System (RRS) has been developed to provide rapid access to MODIS data globally, with initial emphasis on 250 m color composite imagery and active fire data. Fire detection is based on a contextual algorithm that exploits the strong emission of mid-infrared radiation from fires. This algorithm examines each pixel of the MODIS swath, and ultimately assigns to each one of the following classes: missing data, cloud, water, non-fire, fire, or unknown. In this paper, we introduce the MODIS Rapid Response System established at the Korea Aerospace Research Institute (KARI) and present some application results for Korea using the direct broadcast data acquired at KARI ground station.

  • PDF

Forest fire experiment toward the detection of forest fires using RS - Thermal and reflectance environment change observation at ground level -

  • Tanpipat, Veerachai;Honda, Kiyoshi
    • Proceedings of the KSRS Conference
    • /
    • 2002.10a
    • /
    • pp.690-695
    • /
    • 2002
  • In this forest fire experiment the ThermoViewer was set up on the platform built on a tree and observed the temperature change, before, during and after the fire. The fire experiment had been carried out not only the day of the forest fire experiment but also continued for four months after the forest fire had been gone. The results from the experiment showed that the temperature difference is significant in the afternoon; therefore, afternoon satellite passing is better and suitable time for active forest fires and burnt scars detection; moreover, after 83 days, the burnt and un-burnt vegetation become almost the same condition, fully regenerated and the temperature difference become nearly 0$^{\circ}$ Celsius, so there is not enough temperature different between burnt and un-burnt vegetation for current sensors to distinguish the difference anymore.

  • PDF

Fire detection in video surveillance and monitoring system using Hidden Markov Models (영상감시시스템에서 은닉마코프모델을 이용한 불검출 방법)

  • Zhu, Teng;Kim, Jeong-Hyun;Kang, Dong-Joong;Kim, Min-Sung;Lee, Ju-Seoup
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2009.04a
    • /
    • pp.35-38
    • /
    • 2009
  • The paper presents an effective method to detect fire in video surveillance and monitoring system. The main contribution of this work is that we successfully use the Hidden Markov Models in the process of detecting the fire with a few preprocessing steps. First, the moving pixels detected from image difference, the color values obtained from the fire flames, and their pixels clustering are applied to obtain the image regions labeled as fire candidates; secondly, utilizing massive training data, including fire videos and non-fire videos, creates the Hidden Markov Models of fire and non-fire, which are used to make the final decision that whether the frame of the real-time video has fire or not in both temporal and spatial analysis. Experimental results demonstrate that it is not only robust but also has a very low false alarm rate, furthermore, on the ground that the HMM training which takes up the most time of our whole procedure is off-line calculated, the real-time detection and alarm can be well implemented when compared with the other existing methods.

Prediction Principle and System Structure for the Detection of Incipient Electrical Fire (전기화재 예지원리 및 징후검출 시스템 구조)

  • 김창종
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.9 no.4
    • /
    • pp.71-77
    • /
    • 1995
  • Electrical fire in residential, commercial, and industrial areas occupies 40 percent of overall fire accidents as of the year of 1994. The causes of most electrical fires were studied and, based on this investigation, the principle of the early detection or prediction of the electrical fires is developed. The basic principle is to early detect electrical arcs or sparks caused by faulty connections and insulation failures. the structure of the prediction system based on microcontroller technique is presented.

  • PDF

Study on the Development of Optical Sensor Linear Fire Detection System Using Raman Scattering (라만산란을 이용한 광센서 선형 화재감지시스템 개발에 관한 연구)

  • Lee, Gun-Ho;Lim, Woo-Sub;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.30 no.4
    • /
    • pp.27-38
    • /
    • 2016
  • The paper reports the development of a distributed temperature sensing (DTS) system, which is a fire detection system using optical sensor linear detectors that depends on foreign and domestic technologies. This study accordingly analyzed the electrical signal patterns of Raman scattering light mainly used for temperature sensing among back-scattered light generated in optical fiber by using an oscilloscope. Through the measurement results, it could be verified that the Stokes signal patterns had little change by the temperature increase, but the temperature-sensitive anti-Stokes patterns had relative increase of the changes. This study developed a K-DTS system, which is an optical sensor linear fire detection system composed of an optical repeater and a receiver that can detect fires using Raman scattering light. It could be verified that the developed K-DTS system satisfied the type approval standards through the sensitivity tests using the rate of rise type and fixed temperature type sensitivity testers. In addition, performance experiments have been performed for performance evaluation of the K-DTS system developed in comparison with S-DTS system which has been imported from abroad and widely used in Korea. It can be confirmed from the results of the performance experiments using model tunnels that comparable performances can be obtained in fire detection locations and the measurements of fire temperatures.

연기와 연기감지기술에 대한 고찰

  • Lee, Bok-Yeong
    • Fire Protection Technology
    • /
    • s.15
    • /
    • pp.28-38
    • /
    • 1993
  • This report is explain the nature of smoke and the principle of smoke detection. The object of this research is to understand the hazard of smoke and select the optimum smoke detectors, according to the types of smoke and the particle size of smoke produced by fire

  • PDF