• Title/Summary/Keyword: Fire Control Model

Search Result 160, Processing Time 0.036 seconds

A Numerical Study on Smoke Control for Smoke Control Systems and Air Flowrate (제연방식과 풍량에 따른 제연성능의 수치적 연구)

  • 박외철
    • Fire Science and Engineering
    • /
    • v.17 no.2
    • /
    • pp.56-61
    • /
    • 2003
  • The smoke removal rate from a room with an opening was investigated for different smoke control systems by using the large eddy simulation turbulence model of the Fire Dynamics Simulator. The decreasing rate of the particles randomly distributed in the 2m X 2m X 2.4m room was com-pared for the ventilation system, pressurization system and extraction system, and for the air flowrate of the ventilation system. Difference in the smoke removal rate among the three smoke control systems was small when the opening was closed. The pressurization system showed less smoke removal rate than the other two systems when the opening existed, and hence is not recommended for subway stations with large openings. It was also shown that a less flowrate in the ventilation system leads to a much longer smoke removal time.

A Study on the smoke control in underground space of the buildings (건축물 지하생활공간의 연기제어 기술개발 및 실물모의실험)

  • Bae, Sang-Hwan;Baik, Ki-Seung
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.107-110
    • /
    • 2008
  • This study is aimed to develop fundamental technology on the smoke control method by simulation model and scale model simulation technique in underground space. Thereby, this research aimed to establish design elements and technologies required for smoke control system that is suitable to underground spaces of the high-rise residential-commercial and office buildings in order to minimize the loss of lives and property damage in case of fire.

  • PDF

The Ventilation Plane Due to Smoke Driving Combined Forces in Super High-Rise Buildings (초고층 건물에서 연기이동 복합력에 의한 환기계획)

  • Lee, Dong-Myung
    • Fire Science and Engineering
    • /
    • v.30 no.4
    • /
    • pp.82-87
    • /
    • 2016
  • The ventilation system for the efficient operation of the building services systems in the ventilation plan of super high-rise buildings is used to combine smoke control systems. This study evaluated models of super high-rise buildings with four basement levels and 59 stories and investigated the pressure distribution of each floor by the smoke driving forces by numerical analysis. The smoke driving forces on the building of analytical model was analyzed to determine the effects of the ventilation plan and smoke control plane. In addition, when a combination with ventilation and smoke control of the kitchen ventilation damper in the ventilation plan of analysis model building was designed based on the these results, the relationship between the opening and closing force of the damper and smoke driving combined forces to act on the design pressure of the damper by a motion analysis simulation. The driving units of the damper were selected from the analytical results.

Numerical Analysis on Pressurization System of Smoke Control in Consideration of Stack Effect (연돌효과를 고려한 급기가압 제연시스템의 수치해석 연구)

  • Kim, Jung-Yup
    • Fire Science and Engineering
    • /
    • v.27 no.4
    • /
    • pp.1-6
    • /
    • 2013
  • When the pressurization system that uses difference of pressure for smoke control is designed, the factors influencing on the pressure field in building should be applied to design process and the stack effect is one of the main factors. Numerical analysis based on network model in 20-story building is carried out to analyze the pressurization system of smoke control in consideration of stack effect. Calculations are conducted for three conditions, that is, stack effect only, pressurization only and stack effect plus pressurization. Results including the detailed pressure field and flow rate at each floor are represented and the stack effect are effectively visualized. Meanwhile, the pressure of stairwell is increased as much as the summation of the stack effect and pressurization, and the problem induced by rise of pressure is pointed out.

Characteristics of Smoke Propagation in Railway Tunnels with Rescue Station (구난역을 갖는 철도 터널 내부의 연기거동 특성)

  • Jang, Won-Cheol;Kim, Dong-Woon;Lee, Seong-Hyuk;Ryou, Hong-Sun
    • Fire Science and Engineering
    • /
    • v.23 no.4
    • /
    • pp.13-18
    • /
    • 2009
  • The main objective of the present study is to investigate smoke propagation in railway tunnels with rescue stations. In particular, based on measurement of HRR (heat release rate) for pool fires formed at different locations, the influence of fire source location on smoke behavior is examined. The fuel is n-heptane and pool fires are generated with a square length 4cm. With the use of MVHS (Modified Volumetric Heat Source) model for fire source, extensive numerical simulations are performed by using the commercial code FLUENT (Ver.6.3) Predicted smoke temperatures and smoke propagation are discussed. From numerical predictions, it is found that ventilation systems may be necessary in the railway tunnels because the smoke moves along the tunnel, and consequently it enters the non-accident tunnel. It is also confirmed that the cross-passage and fire protection wall systems contribute to control the smoke.

A study on quantitative risk assessment for railway Tunnel fire (철도터널에서 차량화재시 정량적 위험도 평가에 관한 연구)

  • Yoo, Ji-Oh;Nam, Chang-Ho;Jo, Hyeong-Je;Kim, Jong-Won
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.12 no.4
    • /
    • pp.307-319
    • /
    • 2010
  • As we learned in Daegu subway fire accident, fire in the railway tunnel is prone to develop to large disaster due to the limitation of smoke control and smoke exhaust. In railway tunnel, in order to ensure fire safety, fire prevention and fighting systems are installed by quantitative risk assessment results. Therefore, in this research, developed the program to establish quantitative risk assessment and suggested quantitative safety assessment method including fire scenarios in railway tunnel, fire and evacuation analysis model, fatality estimate model and societal risk criteria. Moreover, this method applys to plan preventing disaster for Honam high speed railway tunnel. As results, we presented the proper distance of escape route and societal risk criteria.

Performance Computer Controller for fire Control Hovercraft (소방용 호버크래프트 성능 향상을 위한 컴퓨터 제어기)

  • Cho, Moon-Taek;Song, Ho-Bin;Kim, Young-Chun;Back, Dong-Hyun;Hong, Bong-Hwa;Joo, Hae-Jong
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2142-2143
    • /
    • 2011
  • Amphibious possible, and good fuel economy, so as leisure and transport has increased the use of hovercraft. Fire started in Korea, the prevalence is increasing in demand as the trend has been increasing steadily. In this paper, the hovercraft's forward and backward direction can be controlled in order to free the reverse bucket control system was developed. Control due to development by promoting the flow of air and turn right, turn left and easy to reverse the life-saving and stable at high speed, etc. has made possible the operation of hovercraft. To prove the validity of the proposed controller in Matlab simulation and the actual delivery at the firehouse, built into a model for the demonstration test was performed.

  • PDF

Reduced-Scale Tests of A Intelligent Tunnel Smoke-Control System (지능형 터널 배연시스템 축소모형 실험)

  • Son, Yun-Suk;Park, Won-Hee;Kim, Chi-Hun;Jung, Woo-Sung
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.378-383
    • /
    • 2011
  • 지능형 터널 배연시스템은 터널상부의 온도를 감지하는 온도감지부에서 들어오는 신호를 해독하여 화재위치 및 화재크기를 선정하고 제연설비의 운전방향 및 배연량을 조절함으로써 연기를 효율적으로 제어할 수 있는 시스템이다. 지능형 터널 배연시스템의 성능을 검증하기 위하여 실물터널의 크기를 1/60로 축소한 모델에서 두가지의 화원위치에 따라 실험을 수행하였다. 화재 발생 후 초기에는 온도가 상승하다가 제연팬이 작동하면 온도가 급격히 낮아진 후 일정하게 유지되면서 서서히 증가한다. 터널화재시 승객의 피난 장애를 주는 연기의 제어를 통해 터널의 안전성을 향상시킬 수 있는 것을 확인하였다.

  • PDF

Computer Controller Design and Movement of Hovercraft Driving Apparatus (호버크래프트 추진장치의 컴퓨터 제어기 설계와 동작)

  • Baek, Dong-Hyun;Song, Ho-Bin;Cho, Moon-Tack
    • Fire Science and Engineering
    • /
    • v.25 no.5
    • /
    • pp.32-38
    • /
    • 2011
  • Amphibious possible, and good fuel economy, so as leisure and transport has increased the use of hovercraft. Fire started in Korea, the prevalence is increasing in demand as the trend has been increasing steadily. In this paper, the hovercraft's forward and backward direction can be controlled in order to free the reverse bucket control system was developed. Control due to development by promoting the flow of air and turn right, turn left and easy to reverse the life-saving and stable at high speed, etc. has made possible the operation of hovercraft. The controller for the stability and fast response Fuzzy-PID method was used. To prove the validity of the proposed controller in Matlab simulation and the actual delivery at the firehouse, built into a model for the demonstration test was performed.

Study of the Smoke Extraction Efficiency Improvement by the Partial Smoke Extraction System in Tunnel Fire (터널화재시 부분배연설비에 의한 배연효율 향상에 관한 연구)

  • Yoo, Yong-ho;Lee, Eui-ju;Shin, Hyun-jun;Shin, Han-cho|;Yoon, Young-hoon;Kim, Chang-whan
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.8 no.1
    • /
    • pp.53-63
    • /
    • 2006
  • The objective of this study is to analyze the smoke movement and the smoke extraction efficiency using by the partial extraction system for case of tunnel fire. Based on Froude modeling and isothermal model, the 1/20 scaled model tunnel (12m long) was constructed. In the case of the upper critical velocity in the main tunnel, the smoke extraction efficiency shows almost same between group damper and distributed damper. Finally, if the fire occurs on a traffic Jam in a tunnel, it is proposed that the open dampers in partial gallery extract smoke from the main tunnel without jet fan operation. Then, after the passengers have escaped the tunnel, the jet fans work on. On the other hand, If the traffic is uncongested in the tunnel, the jet fans (smoke control system) and partial extraction system (smoke exhaust system) are operated at once in tunnel fire.

  • PDF