• 제목/요약/키워드: Fire Alarm System

검색결과 163건 처리시간 0.032초

클린룸 자동화재탐지설비의 성능위주 방재설계 적용에 관한 고찰 (A Study on the appliance of performance based design to the automatic fire alarm system in clean room facility)

  • 김동성;황철승;이상곤;조원철;이태식
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2007년도 정기총회 및 학술발표대회
    • /
    • pp.513-517
    • /
    • 2007
  • This study is to establish the appliance model for the automatic fire alarm system in clean room within the framework of the performance based design. Because of the environmental and dimensional characters of clean room, this space is exposed to fire and toxic damage, so it is very important to notify the occupants of these dangerous situations.

  • PDF

피난조명 및 음성경보 기능을 내장한 화재경보시스템 개발에 관한 연구 (A Study on the Development of Fire Alarm System with Evacuation Lighting and Voice Alarm Functions)

  • 이건호;최수길;김시국
    • 한국화재소방학회논문지
    • /
    • 제32권4호
    • /
    • pp.25-34
    • /
    • 2018
  • 본 논문은 피난조명 및 음성경보 기능을 내장한 화재경보시스템 개발에 관한 연구이다. 기존 화재감지기에 화재시 피난성능향상을 위해 가장 중요한 화재조기인지 및 피난시야확보가 가능하도록 피난조명 및 음성경보 기능을 자체적으로 내장한 화재감지기 및 시스템을 개발하여 성능을 확인하였다. 개발된 시스템의 경우 평균조도가 1.62 lx, 평균음향 89.7 dB, 평균음성 86.1 dB로 형식승인 및 제품검사 기술기준을 만족하는 것으로 나타났다. 추가적으로 개발된 시스템을 이용한 피난성능실험결과 본 실험조건에서 기존시스템보다 63.08%에서 67.82%까지 피난시간이 단축되는 것으로 나타났다. 개발된 시스템의 경우 자체 음성경보를 통해 화재인지 실패를 방지하고, 비상조명 점등을 통해 최소한의 피난을 위한 가시거리를 제공함으로써 화재피해를 최소화할 수 있고, 화재취약계층인 청각장애인 및 시각장애인까지 고려함으로써 당위성 및 효용성을 갖춘 화재경보시스템으로 활용될 것으로 생각된다.

화재예방을 위한 실시간 모니터링 시스템의 알고리즘 개발 (Development of a Novel Real-Time Monitoring System Algorithm for Fire Prevention)

  • 김병조;김재호
    • 한국안전학회지
    • /
    • 제29권5호
    • /
    • pp.47-53
    • /
    • 2014
  • Despite the automatic fire alarm system, according to the national fire data system of national emergency management agency, the fires account for 40,932 incidents, 2,184 injuries and about 430 billion won in property losses in 2013. Since the conventional automatic fire alarm system has several weaknesses related to electrical signal such as noise, surge, lighting, etc. Most fires are mainly caused by electrical faults, mechanical problem, chemical, carelessness and natural. The electrical faults such as line to ground fault, line to line fault, electrical leakage and arc are one of the major problems in fire. This paper describes the development of a novel real-time fire monitoring system algorithm including fault detection function which puts the existing optic smoke and heat detectors for fire detection with current and voltage sensors in order to utility fault monitoring using high accuracy DAQ measurement system with LabVIEW program. The fire detection and electrical fault monitoring with a proposed a new detection algorithm are implemented under several test. The fire detection and monitoring system operates according to the proposed algorithm well.

자동화재 탐지설비의 비화재보 감소방안 (A Study about False Alarm of Automatic Fire Detection System)

  • 이종화;이춘하;김시국;공하성
    • 대한안전경영과학회지
    • /
    • 제13권1호
    • /
    • pp.41-49
    • /
    • 2011
  • The automatic fire detection system is an important facility installed with focusing on minimizing the damage from a fire. This paper presents in the followings as the methods to reduce the false alarm of the automatic fire detection system; first, to prepare for legal standard so that revised legal standard can be applied to the fire fighting property prior to revision; second, to introduce the performance based fire detection protection design in the law based fire protection design; third, to maintain the wiring of worn-out detector; forth, to introduce an evaluation system to the education for the fire warden; fifth, to extend the standard of MTBF(meantime between failure) of the detector; sixth, to extend of installing the analog type detector; seventh, to improve the structure of reset switch.

동굴 공간의 안전과 방재차단벽 (Embodiment of Firewall Block for Safety in the Cave)

  • 김보수;김강원;김태환;박정호;이영재;소대화
    • 동굴
    • /
    • 제87호
    • /
    • pp.8-13
    • /
    • 2008
  • The automatic firewall block and fire alarm system was embodied by using gas circuit and wireless communication equipment, using a smoke sensor (ST-QA1A) and RF Module. OR-CAD was also used for testing circuit system and experiment circuit after assembling circuit. As a result in experiment, the gas sensor detected well an imaginary smoke and worked reliably for driving action of firewall block motor and wireless warning alarm. Through the smoke sensitive perception from the fire, the warning alarm and the preventing fire propagation from the specific closed region were verified reliably. The gas sensor and RF module for firewall and fire alarm system were actually available.

지능형제어기를 이용한 분산 방계시스템에 관한 연구 (A Novel Design of the Distributed Fire Alarm Control System by Developing Intelligent Control Modules with LonTalk Protocol)

  • 홍원표;이승학
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2001년도 학술대회논문집
    • /
    • pp.157-162
    • /
    • 2001
  • There are many economic and operational reasons to integrate fire alarm signaling system with other building automation system. Integration of this requires communication standard and careful design practices. The important point for this is also the development of intelligent control modules for replacing the conventional zone adapter in fire system. Therefore, this paper proposes an new conceptual design of the distributed fire alarm signaling system and a new intelligent control modules with LonTalk protocol. Newly proposed additions to LonWorks network make it very well suited for integrating fire systems with other building automation systems. Additionally, it is very important that best design practices, test procedures and building codes need to be modernized to accommodate Integrated building systems.

  • PDF

A Novel Design of the Distributed Fire Alarm Control System by Developing Intelligent Control Modules with LonTalk Protocol

  • Hong, Won-Pyo;Goo, Sung-Hoan;Park, Won-Guk
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.70.6-70
    • /
    • 2001
  • There are many economic and operational reasons to integrate fire alarm signaling system with other building automation system. Integration of this requires communication standard and careful design practices. The important point for this is also the development of intelligent control modules for replacing the conventional zone adapter in fire system. Therefore, this paper proposes an new conceptual design of the distributed fire alarm signaling system and a new intelligent control modules with LonTalk Protocol. Newly proposed additions to Lonworks network make it very well suited for integration fire systems with other building automation systems. Additionally, it is very important that best design practices ...

  • PDF

FDS을 이용한 수직 연소확대 구조의 화재경보방식에 관한 연구 (A Study on the Fire Alarm System of Vertical Fire Spread Structure by Using FDS)

  • 구선환;송영주
    • 한국화재소방학회논문지
    • /
    • 제30권5호
    • /
    • pp.100-107
    • /
    • 2016
  • 오늘날 인간의 삶의 질 향상과 다양한 욕구를 충족시키기 위한 건축물은 대형화, 고층화, 다양화되는 추세이며, 이에 따른 화재의 발생빈도 및 잠재적인 위험요소가 증가되고 있다. 특히, 화재발생 시 수직으로의 연소확대 위험성이 증가되어 재실자의 피난시간이 지연되는 문제점이 있다. 이러한 문제점을 극복하기 위해서는 화재를 조기에 감지하고 건축물의 구조 등을 감안하여 위험순위에 따른 화재 경보방식을 적용할 필요가 있다. 따라서, 본 논문에서는 수직 연소확대의 위험성을 많이 내포하고 있는 2가지 구조인 전면형 이중외피 구조와 계단 구조에 대해 수직 연소확대 특성을 설명하고, 국내 외 화재경보방식을 비교 검토한 후 FDS 이용하여 연기밀도, 가시거리, CO 농도를 비교 분석하여 각 구조에 적합한 화재경보방식을 제안하였다.

CCD 카메라를 이용한 열화상 실시간 추정과 화재경보 (Thermal Image Real-time estimation and Fire Alarm by using a CCD Camera)

  • 백동현
    • 한국화재소방학회논문지
    • /
    • 제30권6호
    • /
    • pp.92-98
    • /
    • 2016
  • 본 논문은 Charge-Coupled Device (CCD) 카메라를 이용한 열화상의 실시간 추정과 화재경보에 대하여 논한 것으로 각도 및 위치에 따른 특징점 분석과 동일 형상의 벡터 성분 좌표점 설정에 따른 이미지 융합이 잘 되었다. 영상을 Display하는 픽셀의 데이터 값은 0~255, 센서 출력값은 0~5,000로 하여 정확성이 높았다. 시험결과 시험체로부터 500 m, 1000 m, 1500 m 거리에서 화염에 의한 시험체의 작동시간은 각각 7초, 26초, 62초 소요 되었고 화면이미지 생성이 효과적으로 이루어졌다. 화재 발생 진단은 주의/경보/화재의 3단계로 프로그램하여 Alarm의 순차적 동작과 SNS 전송이 이루어졌다. 비화재보시험을 위해 백열등, 형광등에 대해 시험하였으나 모두 비화재보를 발생하지 않았다. 시간대별 화염의 변화영상과 진행방향 및 확산속도의 분석은 화재진행상황 예측이나 열화상 실시간 추정과 경보로 비화재보 감소가 가능함을 확인하였다.

유비쿼터스 환경을 위한 통합형 화재수신기 개발에 관한 연구 (A Study on the Development of Integrated Type Fire Alarm Control Panel for Ubiquitous Environment)

  • 박세화
    • 한국화재소방학회논문지
    • /
    • 제24권1호
    • /
    • pp.24-30
    • /
    • 2010
  • 유비쿼터스 환경에 적용을 위한 목적으로 구현된 통합형 화재수신기의 개발 경험을 보고한다. 유비쿼터스 환경을 위해 수신기가 본래 가지고 있는 능력에 부가적으로 크게 세가지의 추가적인 기능이 구현된다. 즉, 지그비가 적용된 무선감지기와의 접속기능과 이더넷을 통해 전송되는 카메라 영상신호의 화면출력 기능이다. 또한 분산형 화재수신기 간의 시간동기화 기능을 위해 GPS 모듈이 적용되고 구현된다.