• Title/Summary/Keyword: Fire Alarm System

Search Result 163, Processing Time 0.021 seconds

A Study on the Development of a Duct-dedicated Intelligent Fire Detection System (덕트전용 지능형 화재감지시스템 개발에 관한 연구)

  • Kim, Si-Kuk;Lee, Gun-Ho;Lee, Chun-Ha;Lim, Woo-Sub
    • Fire Science and Engineering
    • /
    • v.29 no.4
    • /
    • pp.39-48
    • /
    • 2015
  • This research was done to develop a duct-dedicated intelligent fire detection system to prevent fires and minimize fire damage of the industrial duct having a high fire risk. To understand the fire hazards of the ducts, the analysis was centered on the Daegu Textile Industrial Complex, where industrial ducts are used frequently. With this in the background, dedicated fire detectors and fire alarm control panel, which can prevent fires and to minimize fire damages to the ducts, were designed and produced, after which the performance was confirmed. As a result of performance experiments, it was shown that a duct-dedicated intelligent fire detection system had excellent adaptability and temperature accuracy. Through real-time temperature monitoring of the inside of the ducts, it was confirmed that duct fires could be efficiently extinguished by stepwise control of linkage facilities according to the setting temperature.

The Research & Development of Infra-Red Flame Detector (적외선 불꽃감지기 개발연구)

  • 이복영;권오승;정창기;박상태;조성수
    • Fire Science and Engineering
    • /
    • v.14 no.2
    • /
    • pp.1-6
    • /
    • 2000
  • The radiant energy from a flaming fire of fuels containing carbonaceous material can be applied to fast growing fire. Raiant energy sensinsing technique applied detectors are ultimately effective when early detecting fire alarm system is required or the smoke and heat detectors can not be applied. This study investigated the characteristics of sun light, artificial light and flame radiation light and the foundation technique of flame detecting is established. Pyroelectric element proper for the characteristics of flame radiant energy developed and circuit stabilizing technique, electro-magnetic immunity technique, durable and reliable operating technique to circuits developed.

  • PDF

Evaluation Methods of Flame Retardants for Wooden Cultural Properties

  • Son, Dong Won;Han, Gyu-Seong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.42 no.5
    • /
    • pp.590-596
    • /
    • 2014
  • Wooden cultural heritages of Korea have been destroyed by fire in many cases. As a result, a number of methods to protect wooden cultural properties against fire were introduced. A way of protecting wooden cultural properties installations of fire equipments such as sprinkler, fire alarm system, or fire extinguisher. Another way of protecting wooden cultural properties is to treat them with flame retardants for their safety. Development of a very effective flame retardant with a good performance without affecting danchung and wood quality is required. At the same time, methods of evaluating flame retardant treated woods should be devised to assess their efficacy. In this study, combustion characteristics using cone-calorimeter, limit oxygen index, moisture absorption, iron corrosive and weathering were analyzed to evaluate the flame resistance efficacy and performance of flame retardants treated woods. The evaluation methods of flame retardants for wooden cultural heritage were suggested.

A Study to Prevent the Fire in Residential Buildings (주거용 건축물의 화재 예방에 관한 고찰)

  • Park, Kyong-Jin;Kim, Hye-ree;Lee, Bong-Woo;Park, Shin-young
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.2_2
    • /
    • pp.307-312
    • /
    • 2020
  • This study presents problems and improvement measures for the supply rate of single-alarm detector and fire extinguisher installed in households. Statistics from the NFDS show that 18 percent of all fires and 45 percent of deaths occurred in residential buildings over the past eight years. It was less than 60% that households be equipped rate of basic fire-fighting systems by 2019. In this study, I analyzed the law and statistics of fire to devise a method for fire safety. I proposed that the basic fire-fighting systems is be equipped in households. Like this : First, a free distribution policy for the over 60 years of age and Areas where is fire engine difficult to enter. Second, the policy of adopting safety pay in disaster. Third, the policy of expanding supply through the revision of the Licensed Real Estate Agents Act. Fourth, the policy of self-regulating installation by safety education and set up a data base system. Fifth make a law of household's National Fire Safety Standards.

Research for the Configuration of the Outside Sprinkler System (외벽방호 스프링클러시스템 구성에 관한 연구)

  • Min, Se-Hong;Yun, Jung-Eun;Sun, Ju-Seok;Jeong, Sang-Ho;Chea, Chang-Hun;Kim, Suck-Jun
    • Fire Science and Engineering
    • /
    • v.26 no.1
    • /
    • pp.102-112
    • /
    • 2012
  • In this research, configulation of outside sprinkler system the prevention and postponement of vertical diffusion of blaze was studied prior to this study, vertical diffusion protecting sprinkler head has been developed and the sprinkler system was applied with discharge pressure of 0.05 MPa and flow of 60 l/min witch is stated in NFPA13's Exposure Protection Sprinkler Systems. Through the system design, we applied the system to the sample building and we made pertinent system to work manually and automatically linked to a fire alarm system. Also, we conducted a real-size mock up test verify the cooling effect of the outer wall and the postponement effect of the flame.

Analysis of the Working Conditions of Fire Protection Systems in the Goyang Bus Terminal Building Fire (고양종합터미널화재 시 소방시설의 작동실태 분석)

  • Lee, Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.32 no.3
    • /
    • pp.95-107
    • /
    • 2018
  • This study analyzed the working conditions of the fire protection system in the Goyang Bus Terminal fire based on the fire investigation results. The results were as follows. First, extinguishing using an indoor fire hydrant was not attempted immediately after the fire burned the ceiling urethane foam. Second, a sprinkler alarm valve was turn off and did not work in the repair work space of the 1st basement. On the other hand, the sprinklers in the $2^{nd}$ basement, $1^{st}$ floor, $2^{nd}$ floor, and $3^{rd}$ floor worked and prevented the fire from moving to stories other than the $1^{st}$ basement. Third, although an exit light worked normally, it was not installed in the exit from the waiting room in the $2^{nd}$ floor to the bus stop. This resulted in many casualties. Fourth, although a fire receiver sent an electrical signal to the fan controller of the smoke control system, it was treated manually in the fan controller and the fan in the $2^{nd}$ floor did not work.

A Study on the Improvement of Electric Supervisory in Apartment Complex (아파트 단지의 전력감시반 개선 연구)

  • 홍규장;김채규
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1993.10a
    • /
    • pp.51-54
    • /
    • 1993
  • In this paper, it is proposed the the SCADA(Supervisory control and Data Acquisition) system in Apartment complex. The proposed SCADA system make use of the computer CRT(Cathod RAy Tube), which automatically observe the Electrical Facility, Elvator Facility, Fire Alarm Facility and process in the real-time data. In order to improve the hardware performance and the information process, the SCADA system composed of master-slave topology and decentralized the supervisory Facility. This system is expected the retrenchment of construction expenditure and the level-up of supervisory execution.

  • PDF

Development of Addressable P-Type Automatic Fire Alarm System Using Embedded System (임베디드시스템을 이용한 주소형 P형자동화재탐지설비개발)

  • Kim, Si-Kuk;Jee, Seung-Wook;Yang, Seung-Hyun;Lee, Jae-Jin;Kim, Pil-Young;Lee, Gun-Ho;Lee, Chun-Ha
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.518-521
    • /
    • 2011
  • 본 논문에서는 화재 및 비화재보시 동작감지기의 정확한 위치전송이 가능하고, 화재 시 동일 회로상(Loop)의 모든 감지기가 본연의 기능을 수행할 수 있는 주소형 감지기 및 화재 시 정확한 위치확인 및 연동된 설비들의 출력상황이 확인 가능한 임베디드 내장형 주소형 수신기를 개발하였다.

  • PDF

Basic Study for performance Improvement of Fire Detectors System at Domestic Apartment Buildings (국내 공동주택 화재감지시스템의 성능개선을 위한 기초연구)

  • Son, Bong-Sae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.1
    • /
    • pp.533-538
    • /
    • 2014
  • This study examines the performance of and searches for improvements to the existing automatic fire detection systems installed at domestic apartment buildings as a basic study for development of intelligent fire detection systems specifically for apartments. Thus, this study aims to find out the problems in performance and maintenance of the existing fire detectors installed at apartment buildings which is the prerequisite process for development of intelligent fire detection system for that specific application. It is also found impossible to check whether or not the detectors installed at each apartment are in an operational state at normal times. This study finds that it is desirable to replace the slow-sensing heat detectors by a smoke and single smoke detectors which can detect a fire at its early stage in an effort to improve the problems of fire detectors installed at apartment buildings presently. Because we need to the independence fire detection system of apartment building.

Development of Parallel Arc Fault Detector Using Ripple Voltage (리플전압을 이용한 병렬아크 사고 감지기 개발)

  • Choi, Jung-Kyu;Kwak, Dong-Kurl
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.5
    • /
    • pp.453-456
    • /
    • 2016
  • The major causes of electrical fire in low-voltage distribution lines are classified into short-circuit fault, overload fault, electric leakage, and electric contact failure. The special principal factor of the fire is electric arc or spark accompanied with such electric faults. This paper studies the development of an electric fire prevention system with detection and alarm of that in case of parallel arc fault occurrence in low-voltage distribution lines. The proposed system is designed on algorithm sensing the instantaneous voltage drop of line voltage at arc fault occurrence. The proposed detector has characteristics of high-speed operation responsibility and superior system reliability from composition using a large number of semiconductor devices. A new sensing control method that shows the detection of parallel arc fault is sensed to ripple voltage drop through a diode bridge full-wave rectifier at electrical accident occurrence. Some experimental tests of the proposed system also confirm the practicality and validity of the analytical results.