• Title/Summary/Keyword: Finned-tube

Search Result 159, Processing Time 0.024 seconds

Analysis and design of LNG open rack vaporizer (LNG 개방래크 기화기의 해석 및 설계)

  • Park, J.S.;Chang, H.M.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.2
    • /
    • pp.189-197
    • /
    • 1997
  • The vaporizing characteristics of LNG(liquefied natural gas) via heat exchanger with sea water are analytically studied for an open rack vaporizer(ORV). This study is intended to supply the design data for the domestic fabrication of the corrosion-resistant vaporizer tube. A computational program is developed to predict the exit temperature of LNG for various conditions. In the program, thesimple and justifiable heat transfer models are selected for fully-developed internal flow of LNG, the star-shaped finned-tube, and the external falling films of sea water, as well as the possible ice formation and the fouling on the tube walls. It is found that the enongh corrugation inside of the tube wall is the most significant in the vaporizer performance for the current operating conditions. the effects of other design parameters on the heat exchanger between LNG and sea water are quantitatively presented.

  • PDF

Experimental Study on the Heat Transfer Characteristics of Spiral Fin-Tube Heat Exchangers (나선형 핀튜브 열교환기의 열전달 특성에 관한 실험적 연구)

  • Yun Rin;Kim Yongchan;Kim Sru;Choi Jong Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.6
    • /
    • pp.529-535
    • /
    • 2005
  • This study experimentally examines the air-side performance of spiral finned tube heat exchangers. The effects of fin spacing, fin height, and tube alignment were investigated. Reduction of fin spacing decreased the Colburn j factor. However, the effect of fin height on the Colburn j factor was negligible. An increase of tube row decreased the Nusselt number for both staggered and in-line tube alignments. However, the decrease of the Nusselt number for the in-line tube alignment was much more significant than that of the staggered tube alignment. The average Nusselt number of the staggered tube alignment was larger than that of the in-line tube alignment by $10\%$ when the Reynolds number ranged from 300 to 1700. An empirical correlation of the Nusselt number was developed by using geometric parameters of heat exchanger and correction factors. The correction factor considered the effects of tube alignment and number of tube rows on the heat transfer. The proposed correlation yielded a mean deviation of $4\%$ from the present data.

Heat Transfer Enhancement by Fins in a Latent Heat Storage System Using Phase Change Material (상변화물질을 이용한 축열시스템에서 핀에 의한 열전달 촉진 연구)

  • 한승구;한귀영
    • Journal of Energy Engineering
    • /
    • v.5 no.2
    • /
    • pp.115-122
    • /
    • 1996
  • Heat transfer characteristics of low temperature latent heat storage systems have been examined for the circular finned and unfinned tubes using Na$_2$B$_4$O$\_$7/10H$_2$O as a phase change material. In order to reduce the supercooling of PCM, 3 wt% of Na$_2$B$_4$O$\_$7/10H$_2$O was added as the nucleating agent and 2.2 wt% of acrylic acid sodium sulfate was used as the thickener. The heat storage vessel has dimension of 530 mm height, 74 mm 1.D. and inner heat transfer tube is 480 mm height and 13.5 mm O.D. Water was employed as the heat transfer fluid. During the heat recovery experiment, the heat recovery rate was affected by the flow rates and inlet temperature of heat transfer fluid. The enhancement of heat transfer by fins over the unfinned tube system was found to be negligible in the thin finned tube systems, whereas the heat transfer coefficient in the thick finned tube system is approximately 60% higher than that in the unfinned lobe system. The experimentally determined heat transfer coefficient for the unfinned tube and thick finned tube systems are 150-260 W/㎡$^{\circ}C$ and 230-530 W/㎡$^{\circ}C$, respectively. The fin efficiency based on the heat transfer coefficient and area increased by fins was found to be 0.05 and 0.26 for the thin and the thick finned tube systems.

  • PDF

Effects of Absorber Tube Shape and Operating Conditions on Thermal Performance of All-Glass Evacuated Tube Solar Collectors (이중 진공관형 태양열 집열기의 집열관 내부 형상과 운전 조건이 성능 변화에 미치는 영향)

  • Choi, Eun-Young;Kim, Yong;Seo, Tae-Beom
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.1
    • /
    • pp.19-25
    • /
    • 2005
  • All-glass evacuated tube solar collectors consist of glass evacuated tubes and absorber tubes. Solar thermal energy from the sun is transferred to the working fluid through the glass evacuated tube and the absorber tube. Several collectors which have different absorber tubes are tested to find the effects of the absorber tube shapes and the operating conditions such as the incident heat flux and the flow rate. As the results, the efficiency of the collector which has a finned tube U tube is about $2{\sim}5%$ higher than that of the others in all cases on an average. And the collector has a finned U tube has the highest efficiency at the high flow rate and the low incident heat flux. In this condition, the outlet mean temperature is low and the heat loss becomes small. Also, it is known that the fin effect is greater than the shade effect.

A Study on Heat Transfer Enhancement of Oil Cooler (유냉각기의 열전달 촉진에 관한 연구)

  • Cho, D.H.;Lim, T.W.
    • Journal of Power System Engineering
    • /
    • v.15 no.3
    • /
    • pp.25-30
    • /
    • 2011
  • A shell-and-tube oil cooler with plate fins was suggested to improve the defect of the conventional shell-and-tube oil cooler. Experiments were conducted to evaluate the heat transfer performance on the shell side of shell-and-plate finned tube oil cooler with three different tube numbers(9, 13 and 19). Oil flowing on the shell side was cooled by cold water flowing inside the tubes. A shell-and-tube heat exchanger of an oil cooler consisted of one shell pass and two tube passes with the inner tube diameter of 8.82 mm and the tube length of 575 mm. From the experiment of shell-and-tube oil cooler, it was found that the heat transfer coefficient of oil cooler with 9 tubes, as oil flow rate was increased, was approximately 140% and 250% higher than that of 13 and 19 tubes, respectively. The heat transfer coefficient at the water flow rate of $3m^3/h$, also was 120% and 140% higher than that of 2.4 and $1.8m^3/h$, respectively.

An experimental study on heat transfer augmentation in fluidized bed heat exchanger (유동층형(流動層形) 열교환기(熱交換器)에서 전열증진(傳熱增進)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Yoo, Ji-Oh;Seo, Jeong-Yun
    • Solar Energy
    • /
    • v.13 no.2_3
    • /
    • pp.91-106
    • /
    • 1993
  • The purpose of this study was to investigate the enhancement of heat transfer coefficient in double pipe fluidized bed heat exchangers. The inner tube used a smooth tube and a finned tube equipped with longitudinal fins. The heat transfer coefficients between the heated tube and fluidized bed of alumina beads were calculated as a function of fluidized velocity in various particle sizes($d_p$=0.41, 0.54, 0.65, 0.77mm) and static bed heights($H_o$=50, 100, 150, 200, 250mm). The coefficient for finned tube is higher than for smooth tube. And the maximum increasing rate is 7.8 times in smooth tube and 12.9 times in finned tube.

  • PDF

Numerical Simulation of Plate Finned-Tubes Condenser (평판휜-관 응축기의 수치 시뮬레이션)

  • Min, M.S.;Choi, S.G.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.3
    • /
    • pp.193-205
    • /
    • 1994
  • A simulation program of the plate finned-tubes condenser widely used in the air conditioning system was developed. The program took into account the variations of the flow properties and fluid friction factor of refrigerant, and the heat transfer coefficients of refrigerant and air sides. The program was applied to a copper tube condenser which has outside diameter of 10.05mm, inside diameter of 9.35mm, length of 5.20m and three rows arraied staggered. Simulation results were such that refrigerant was super-heated state from the entrance to the 0.14m point, two-phase flow from the 0.14m point to the 4.10m point, sub-cooled state from the 4.10m point to the outlet. The degree of sub-cooled was $6.1^{\circ}C$. The variations of refrigerant quality, temperature, pressure, velocity, specific enthalpy, specific volume and air temperature, tube temperature were showed.

  • PDF

Experimental Study on Thermal Characteristics of Heat Exchanger Modules for Multi Burner Boiler - Part Load Test Results - (멀티버너 보일러용 열교환기 모듈 특성 시험 - 부하별 특성 결과 -)

  • Kim, Jong-Jin;Sung, Choi-Kyu;Ki, Ho-Choong;Kang, Sae-Byul
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1025-1030
    • /
    • 2008
  • We develop heat exchanger modules for a multi-burner boiler. The heat exchanger module is kind of a heat recovery steam generator (HRSG). This heat recovery system has 4 heat exchanger modules. The 1st module consists of 27 bare tubes due to high temperature exhaust gas and the others consist of 27 finned tubes. The maximum steam pressure of each module is 10 bar and tested steam pressure is 4 bar. In order to test these heat exchanger modules, we make a 0.5t/h flue tube boiler (LNG, $40\;Nm^3/h$). The test results of 100% boiler load show that heat transfer rate of 1st module is 49.7 Mcal/h which is 34% of total heat transfer rate and that of 2nd module is 82.6 Mcal/h which is 57% of total heat transfer rate. The reason of higher the heat transfer rate of 2nd module than that of 1st module is that the 2nd heat exchanger module has finned tubes instead of bare tube. The boiler load 50% results show that only 2 heat exchanger modules are needed to extract the heat from the flue gas to water. From this result, it is very important of optimum design of the first finned tube among all water tubes.

  • PDF

Experiments on the Condensation Heat Transfer Enhancement of Horizontal Circular Tube with Threaded Outside Surface (외표면 형상이 원관의 응축열전달에 미치는 영향)

  • Lee, Jin Ho;Nam, Leem Woo
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.17 no.3
    • /
    • pp.230-237
    • /
    • 1988
  • An experiment was carried out to study the condensation heat transfer enhancement of horizontal circular cylinders with varying outside surface configurations. The refrigerant used is Freon-22 and the test condensing temperature is 34.1C. Pin-finned tube shows about 2.5-3.5 times higher overall heat transfer coefficient compared to that of smooth surface tube, thus has larger encomic benifit for condenser design. The condensation heat transfer coefficient was shown to increase as the fin-pitch of the pin-finned tube decreases for film Reynolds number larger than 100.

  • PDF

Simulation of Coextrusion Process of Cladded Finned Tube by Plasticine (동시 압출법에 의한 핀형 튜브 Cladding 공정의 Plasticine 압출 모사)

  • Lee, Hyun-Woo;Park, Jin-Sung;Kim, Woo-Sik;Shin, Dong-Hyuk;Kim, Yong-Seog
    • Transactions of Materials Processing
    • /
    • v.7 no.1
    • /
    • pp.59-65
    • /
    • 1998
  • In this study an attempt was made to simulate the coextrusion process of the cladded finned tube manufacturing by extrusion of plasticine. The effects of the billet and the plate inserted between the ingot and extrusion die on the variation of clad thickness of the extruded tube were studied. The results showed that cladded tube with uniform thickness can be obtained by a proper combination of clad thickness of billet and the plate. The relative strength of the billet and clad materials did not affect significantly on the variation of the clad thickness of the extruded tubes.

  • PDF