• Title/Summary/Keyword: Finite Element Method Magnetics

Search Result 151, Processing Time 0.029 seconds

On the Development of 3D Finite Element Method Package for CEMTool

  • Park, Jung-Hun;Ahn, Choon-Ki;Kwon, Wook-Hyun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2410-2413
    • /
    • 2005
  • Finite element method (FEM) has been widely used as a useful numerical method that can analyze complex engineering problems in electro-magnetics, mechanics, and others. CEMTool, which is similar to MATLAB, is a command style design and analyzing package for scientific and technological algorithm and a matrix based computation language. In this paper, we present new 3D FEM package in CEMTool environment. In contrast to the existing CEMTool 2D FEM package and MATLAB PDE (Partial Differential Equation) Toolbox, our proposed 3D FEM package can deal with complex 3D models, not a cross-section of 3D models. In the pre-processor of 3D FEM package, a new 3D mesh generating algorithm can make information on 3D Delaunay tetrahedral mesh elements for analyses of 3D FEM problems. The solver of the 3D FEM package offers three methods for solving the linear algebraic matrix equation, i.e., Gauss-Jordan elimination solver, Band solver, and Skyline solver. The post-processor visualizes the results for 3D FEM problems such as the deformed position and the stress. Consequently, with our new 3D FEM toolbox, we can analyze more diverse engineering problems which the existing CEMTool 2D FEM package or MATLAB PDE Toolbox can not solve.

  • PDF

Half-Bridge Series Resonant Converter Using A LLCT for High Density Switching Power Supply (LLCT적용 고집적 스위칭 전원을 위한 Half-Bridge 직렬 공진컨버터)

  • Park, J.Y.;Kong, Y.S.;Hwang, I.G.;Kim, E.S.
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.1
    • /
    • pp.56-64
    • /
    • 2006
  • Recently, high density power supply has been researched over the last few years. To achieve high density power supply, the series resonant converter has been steadily used. In this paper, the half-bridge series resonant converter using the integrated Inductor-Inductor-Capacitor-Transformer(LLCT) is described. The structure of LLCT is analysed by the use of Finite Element Method Magnetics(FEMM) Software. Also the experimental results are verified by the simulation based on the theoretical analysis and the 300W experimental prototype.

Design and Analysis for Loss Reduction of High-Speed Permanent Magnet Motor using a Soft Magnetic Composite

  • Lee, Sung-Ho;Kim, Yong-Jae;Lee, Kyu-Seok;Kim, Sung-Jin
    • Journal of Magnetics
    • /
    • v.20 no.4
    • /
    • pp.444-449
    • /
    • 2015
  • Soft magnetic composites (SMCs) are especially suitable for the construction of low-cost, high-performance motors with 3-D magnetic fields. The main advantages of SMCs is that the iron particles are insulated by the surface coating and adhesive used for composite bonding, the eddy-current loss is much lower than that in laminated steels, especially at higher frequencies, and the hysteresis loss becomes the dominant component of core losses. These properties enable machines to operate at higher frequencies, resulting in reduced machine size and weight. In this paper, 3-D topologies are proposed that enable the application of SMCs to effectively reduce losses in high-speed permanent magnet (PM) motors. In addition, the electromagnetic field characteristics of the motor topologies are evaluated and compared using a non-linear finite element method (FEM) based on 3-D numerical analysis, and the feasibility of the motor designs is validated.

Optimum Design Criteria of 250 kW Premium Efficiency Traction Induction Motor Using RSM & FEM (유한요소법과 반응표면법을 이용한 250 kW급 견인 유도전동기 최적설계)

  • Lee, Jung-Ho;Yun, Tae-Won
    • Journal of the Korean Magnetics Society
    • /
    • v.20 no.6
    • /
    • pp.239-243
    • /
    • 2010
  • This paper deals with the optimum design criteria for the premium efficiency of 250 kW traction induction motor, using response surface methodology (RSM) and finite element method (FEM). The focus of this paper is found firstly a design solution through the comparison of torque according to rotor bar shape, rotor dimensions variations. And secondly a mixed resolution with central composite design (CCD) is introduced and analysis of variance (ANOVA) is conducted to determine the significance of the fitted regression model. The proposed procedure allows to be optimized the rotor copper bar shape, rotor slot, rotor dimensions starting from an existing motor or a preliminary design.

Analysis of an Interior Permanent-Magnet Machines with an Axial Overhang Structure based on Lumped Magnetic Circuit Model

  • Seo, Jangho;Seo, Jung-Moo
    • Journal of Magnetics
    • /
    • v.21 no.1
    • /
    • pp.94-101
    • /
    • 2016
  • This paper shows a new magnetic field analysis of an interior permanent magnet (IPM) machines with an axial overhang structure wherein the rotor axial length exceeds that of the stator. The rotor overhang used to increase torque density of the radial flux machine is difficult to analyze because of extra consideration of axial direction, and thus it is general for machine designer to take 3-D finite element analysis (FEA) capable of considering both radial and axial complicated geometry in the machine. However, it requires too much computing time for preliminary design especially for optimization process. Therefore, in this paper a 2-D analytic method using a lumped magnetic circuit model (LMCM) is proposed to overcome the problem. For the analysis of overhang effect, the magnetic circuit is separated and solved from overhang and non-overhang regions respectively. For the validation of proposed concept, 3-D finite element analysis (FEA) is performed. From the analysis results, it is shown that our new proposed method presents good performance in terms of calculating electromotive force (EMF) and torque within a short time. Therefore, the proposed model can be useful in design of IPM with an overhang structure.

Novel Design and Research for a High-retaining-force, Bi-directional, Electromagnetic Valve Actuator with Double-layer Permanent Magnets

  • You, Jiaxin;Zhang, Kun;Zhu, Zhengwei;Liang, Huimin
    • Journal of Magnetics
    • /
    • v.21 no.1
    • /
    • pp.65-71
    • /
    • 2016
  • To increase the retaining force, a novel design for a concentric, bi-directional, electromagnetic valve actuator that contains double-layer permanent magnets is presented in this paper. To analyze the retaining-force change caused by the magnets, an equivalent magnetic circuit (EMC) model is established, while the EMC circuit of a double-layer permanent-magnet valve actuator (DLMVA) is also designed. Based on a 3D finite element method (FEM), the calculation model is built for the optimization of the key DLMVA parameters, and the valve-actuator optimization results are adopted for the improvement of the DLMVA design. A prototype actuator is manufactured, and the corresponding test results show that the actuator satisfies the requirements of a high retaining force under a volume limitation; furthermore, the design of the permanent magnets in the DLMVA allow for the attainment of both a high initial output force and a retaining force of more than 100 N.

Analysis of Magnetic Field Variation for Pulse Wave by Using Finite Element Method (유한 요소법을 이용한 맥진 파형의 자기장 변화 분석)

  • Park, Tae-Young;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.24 no.3
    • /
    • pp.90-96
    • /
    • 2014
  • The magnetic field variation by the permanent magnet fluctuation positioned on a "Chwan" of wrist according to the movement of radial artery was generated. The clip-type pulsimeter equipped with a Hall device sensing magnetic field pulse movement analyzed the characteristics of pulse wave as output signals. The magnetic field curve and pulse waveform simulated by the finite element method were compared and analyzed with each other. Also, the variation of magnetic field distribution one permanent magnet investigated by the fabrication of clip-type pulsimeter simulator. This result suggests that the clip-type pulsimeter can be used the reproducible and efficacious oriental diagnostic medical instrument.

Validity of the Analytic Expression for the Temperature of Joule Heated Nano-wire

  • Ha, Seung-Seok;You, Chun-Yeol
    • Journal of Magnetics
    • /
    • v.12 no.1
    • /
    • pp.7-11
    • /
    • 2007
  • We confirm the validity of the analytic expression for the temperature of the Joule heated nano-wire [C.-Y. You et al. Appl. Phys. Lett. 89, 222513 (2006)] with finite element method. The temperature of the Joule heated nano-wire is essential information for the research of the current induced domain wall movement. The analytic expression includes an adjustable parameter which must be determined. Since the physical origin of the adjustable parameter is simplification of the heat source profile, the validity of the analytic expression must be examined for wide range of the nano-wire structure. By comparison with this analytic expression with the results of full numerical finite element method, the adjustable parameter has been determined. The numerically confirmed adjustable parameter values are in the range of 0.60$\sim$0.69, which is well matched with the theoretically expected one. Furthermore, it is found that the adjustable parameter is a slow varying function of the nano-wire geometry. Based on this numerical confirmation, we can apply the analytic expression for the wide range of the nano-wire geometry with proper adjustable parameters.