• Title/Summary/Keyword: Finger extensor muscle

Search Result 8, Processing Time 0.016 seconds

Comparison of the Effect of Superficial Acupuncture and Deep Acupuncture on Finger Extensor Muscle Function of Normal Person : Randomized controlled trial (정상인의 지신근 근육기능에 대한 천자와 심자의 효과 비교 : 무작위 배정 임상연구)

  • Jo, Yoong-Ki;Kim, Sung-Soo;Lee, Jong-Soo;Chung, Seok-Hee
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.6 no.1
    • /
    • pp.97-104
    • /
    • 2011
  • Objectives : The purpose of this study is to compare the effect of superficial acupuncture to deep acupuncture on normal muscle function. Methods : In Group A, 12 healthy subjects had been treated by deep acupuncture(10mm). In Group B, 12-healthful subjects had been treated by superficial acupuncture(5mm). Each session took 10 minutes. Before and after the treatment, outcomes were assessed by Algometer for muscle tenderness, dynamometer for grasping power and Meridian-Electromyograph(MEMG) for extensor muscles. Results : The Contraction power of finger extensor muscles assessed by MEMG had decreased significantly in both groups. The muscle fatigue of finger extensor muscles assessed by MEMG had increased significantly in Deep acupuncture group. Grasping power assessed by dynamometer had no significant change in both groups. Conclusions : According to above results, superficial acupuncture is more effective on reducing muscle fatigue.

  • PDF

Aerobic Exercise Ameliorates Muscle Atrophy Induced by Methylglyoxal via Increasing Gastrocnemius and Extensor Digitorum Longus Muscle Sensitivity

  • Seong-Min Hong;Eun Yoo Lee;Jinho Park;Jiyoun Kim;Sun Yeou Kim
    • Biomolecules & Therapeutics
    • /
    • v.31 no.5
    • /
    • pp.573-582
    • /
    • 2023
  • Muscle atrophy is characterized by the loss of muscle function. Many efforts are being made to prevent muscle atrophy, and exercise is an important alternative. Methylglyoxal is a well-known causative agent of metabolic diseases and diabetic complications. This study aimed to evaluate whether methylglyoxal induces muscle atrophy and to evaluate the ameliorative effect of moderate-intensity aerobic exercise in a methylglyoxal-induced muscle atrophy animal model. Each mouse was randomly divided into three groups: control, methylglyoxal-treated, and methylglyoxal-treated within aerobic exercise. In the exercise group, each mouse was trained on a treadmill for 2 weeks. On the last day, all groups were evaluated for several atrophic behaviors and skeletal muscles, including the soleus, plantaris, gastrocnemius, and extensor digitorum longus were analyzed. In the exercise group, muscle mass was restored, causing in attenuation of muscle atrophy. The gastrocnemius and extensor digitorum longus muscles showed improved fiber cross-sectional area and reduced myofibrils. Further, they produced regulated atrophy-related proteins (i.e., muscle atrophy F-box, muscle RING-finger protein-1, and myosin heavy chain), indicating that aerobic exercise stimulated their muscle sensitivity to reverse skeletal muscle atrophy. In conclusion, shortness of the gastrocnemius caused by methylglyoxal may induce the dynamic imbalance of skeletal muscle atrophy, thus methylglyoxal may be a key target for treating skeletal muscle atrophy. To this end, aerobic exercise may be a powerful tool for regulating methylglyoxal-induced skeletal muscle atrophy.

Study on the Skin of Hand Lesser Yang from the Viewpoint of Human Anatomy

  • Park, Kyoung-Sik
    • The Journal of Korean Medicine
    • /
    • v.36 no.4
    • /
    • pp.69-73
    • /
    • 2015
  • Objectives: This study was carried out to analyse the skin of the Hand lesser yang in human. Methods: The Hand lesser yang meridian was labeled with latex in the body surface of the cadaver, subsequently dissecting a body among superficial fascia and muscular layer in order to observe internal structures. Results: This study has come to the conclusion that a depth of the skin has encompassed a common integument and a immediately below superficial fascia, and this study established the skin boundary with adjacent structures such as relative muscle, tendon as compass. The skin area of the Hand lesser yang in human is as follows: The skin close to the ulnar root angle of 4th finger nail, above between 4th and 5th metacarpal bone, between extensor digit. minimi tendon(t.) and extensor digit. t., extensor digit. m(muscle). at 2, 4, 7 cun above dorsal carpal striation, triceps brachii m. t., deltoid m., trapezius m., just around the ear, upper orbicularis oculi m. Conclusions: The skin area of the Hand lesser yang from anatomical viewpoint seems to be the skin area outside the superficial fascia or the muscle involved in the pathway of the Hand lesser yang meridian, the collateral meridian, the meridian muscle, with the condition that we consider adjacent skins.

The study of muscular system about Large Intestine Channel of Hand Yangmyung Muscle. (수양명대장경근(手陽明大腸經筋)에 대(對)한 근육학적(筋肉學的) 고찰(考察))

  • Kim, Tae-Young;Oh, Min-Seok
    • Journal of Haehwa Medicine
    • /
    • v.17 no.1
    • /
    • pp.137-143
    • /
    • 2008
  • We have conclusions after the study of muscular system about large intestine channel of hand yangmyung muscle. 1. Judging from many studies of interrelation between Meridian muscle and muscle. it is considered that Meridian muscle theory has some similarities with modern anatomical muscular system. 2. There is a wide defference betwean myofacial pain syndrome and meridian muscle theory in that the former explains each muscle individually, while the latter classifies muscles systematically in the view of organism. 3. It is considered that large intestine channel of hand yangmyung muscle contains extensor digitorum muscle, extensor muscle of index finger, brachioradialis muscle, triceps brachii muscle, Rhomboid major muscle, trapezius muscle, sternocleidomastoid muscle and muscle levator labii. 4. The symptoms of large intestine channel of hand yangmyung muscle is similar to referred pain of modern Myofacial pain syndrome, and the medical treatment of "I-Tong-Wi-Su" is similar to that of Myofacial pain syndrome.

  • PDF

Pollicization of the Middle Finger

  • Bahk, Sujin;Eo, Su Rak;Cho, Sang Hun;Jones, Neil Ford
    • Archives of Reconstructive Microsurgery
    • /
    • v.24 no.2
    • /
    • pp.62-67
    • /
    • 2015
  • Purpose: Pollicization typically involves surgical migration of the index finger to the position of the thumb. This procedure facilitates the conversion of a useless hand into a well-functioning one in patients who are not amenable to the toe-to-hand transfer. However, middle finger pollicization has been rarely reported. Materials and Methods: We reconstructed a thumb by immediate pollicization of the remnants of the middle finger in two patients who sustained a tumor and a trauma, respectively. The former, after cancer ablation was performed, has not been reported literally, and the latter involved free devitalized pollicization of the middle finger using a microsurgical anastomosis. The distal third extensor communis tendon was sutured to the proximal extensor pollicis longus tendon and the distal flexor digitorum superficialis and profundus were sutured to the proximal flexor pollicis longus. The abductor pollicis brevis tendon was sutured to the distal end of the first palmar interosseous muscle. Coaptation of the third digital nerve and the superficial radial nerve branch was performed. Results: Patients showed uneventful postoperative courses without complication such as infection or finger necrosis. Based on the principles of pollicization, a wide range of pinch and grasp movements was successfully restored. They were pleased with the functional and cosmetic results. Conclusion: Although the index finger has been the digit of choice for pollicization, we could also use the middle finger on specific occasions. This procedure provides an excellent option for the reconstruction of a mutilated thumb and could be performed advantageously in a single step.

The effect of muscle activity wristbands with mouse using (컴퓨터 마우스 보조기구 사용이 근활성도에 미치는 영향)

  • Lee, Tae-Sik;Song, Min-Young;Chea, Il-Jun
    • Journal of Korean Physical Therapy Science
    • /
    • v.19 no.1
    • /
    • pp.47-54
    • /
    • 2012
  • Purpose : This study is to know the effect on muscle activity when people use mouse aid or not in computer working environment. Method : 11 people of both sex in their twentieth were tested. As a independent variable, the condition without mouse aid and the condition with movable mouse aid were selected, and as a dependent variable, MVC(%) on four muscles and inconvenience degree(RPE scale) on three body part(wrist, forearm, shoulder) were measured. Result : Analyzing the research, MVC(%) of extensor muscle of finger had notably higher muscle activity than other muscles, and there wasn't notable difference in muscle activity before and after using mouse aid. In case of using mouse aid, we tested by giving RPE questionnaire which segmentalized mental fatigue degree into hand, forearm, and shoulder, and resultingly, there wasn't notable differences perspectively. However, people felt less tiredness subjectively after they use the mouse aid. Conclusion : The usage of mouse aid seems to give comfort to computer users.

  • PDF

Effects of Wrist Position on Electromyographic Activities of Flexor Digitorum Superficials and Extensor Digitorum during Drilling and Pinch Grip (드릴작업과 집기작업 시 손목 자세가 손가락굽힘근과 손가락폄근의 근 활성도에 미치는 영향)

  • Choi, Ji-Woo;Jeon, Hye-Seon;Oh, Yun-Kwon;Yi, Chung-Hwi
    • Journal of the Ergonomics Society of Korea
    • /
    • v.26 no.3
    • /
    • pp.27-33
    • /
    • 2007
  • The purpose of this study was to investigate influence of wrist position on the electromyographic(EMG) activities of the flexor digitorum superficialis (FDS) and extensor digitorum (ED) during drilling and pinch grip. Eighteen healthy subjects had been recruited and each subject performed two tasks (drilling and pinch grip) at three different wrist positions ($30^{\circ}$ flexion, neutral, $30^{\circ}$ extension). The EMG amplitude of each muscle was normalized to the amplitude in the maximal voluntary contraction (MVC). Repeated one-way ANOVA was used to compare the differences of EMG across wrist positions. The FDS EMG activity in both drilling and pinch grip was lowest at $30^{\circ}$ wrist extension and the highest at $30^{\circ}$ wrist flexion. The ED EMG activity was lowest when the wrist was neutral in both tasks. From the results of this study, we can conclude that the desirable wrist positions for drilling and pinch grip tasks are slightly extended or neutral position. Therefore, flexed wrist position should be avoided to reduce the excessive work load on the finger muscles during the tasks.

Design of a New-Concept VDT Workstation Chair for Improving Work Safety (작업안전성 향상을 위한 신개념 VDT 작업용 의자의 인간공학적 설계)

  • Shin, Jong-Hyun;Park, Min-Yong;Kim, Jung-Yong
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.25 no.4
    • /
    • pp.459-465
    • /
    • 1999
  • A new-concept VDT workstation chair with adjustable keyboard/mouse support was proposed to minimize physical discomfort and the risk of cumulative trauma disorders (CTDs) at work sites in this study. First, a three-dimensional human modeling tool $(SAFEWORK^{(R)})$ was used to design the new chair satisfying the anthropometric specifications of Korean population. Second, based upon the result of 3-D graphical simulation, a mock-up chair was constructed with an adjustable keyboard/mouse support directly attached to the chair body. Third, muscle fatigue and subjective discomfort were measured to evaluate the newly developed chair. An experiment was conducted to compare the new workstation chair to the traditional computer chair without keyboard/mouse support. Six volunteer subjects participated in six one-hour word-processing sessions with two different chairs and three different postures. Statistical results indicate that the new-concept VDT chair generally improved subjective comfort level and reduced fatigue in finger flexor/extensor and low back muscle. In conclusion, this new VDT workstation chair is expected to reduce physical discomfort and prevent occupational CTD problems in the long run. Implications of the new design and suggestions for the further development are also addressed.

  • PDF